Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Surg Endosc ; 26(5): 1390-6, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22083339

RESUMO

BACKGROUND: Biologic mesh is widely used for repair of large, complicated hiatal hernias. Recently, there have been reports of complications after its implantation. We studied the course of a large group of patients who had undergone hiatal hernia repair with use of biologic mesh to determine the rate of immediate and late complications related to its use. METHODS: All patients who had biologic mesh placed at the hiatus and who had been followed for at least 1 year were included. Perioperative data were reviewed, and a questionnaire was administered, designed to identify symptoms of gastroesophageal reflux, other symptoms such as dysphagia, and all other operative or endoscopic interventions that occurred after mesh implantation. In addition, postoperative radiologic and endoscopic studies were reviewed to assess signs of complications related to use of mesh. RESULTS: There were 126 patients eligible for the study. We were able to contact 73 of these patients, at median follow-up of 45 months. No mesh-related complications were found. The frequency and severity of heartburn, regurgitation, and dysphagia improved significantly compared with preoperative values, and 89% of the patients reported good to excellent results in terms of overall satisfaction. Six patients recorded worsening of dysphagia postoperatively, but after careful work-up and review of each individual case, no case seemed to be directly related to the mesh. No erosions, strictures, or other complications directly related to use of mesh were found. One patient required reoperation due to hiatal hernia recurrence with gastroesophageal reflux disease (GERD) symptoms. CONCLUSIONS: Use of biologic mesh for laparoscopic repair of large, complicated hiatal hernias appears safe. There were no major complications related to the mesh, and overall satisfaction with the operation was very good.


Assuntos
Hérnia Hiatal/cirurgia , Herniorrafia/métodos , Laparoscopia/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Idoso , Transtornos de Deglutição/etiologia , Feminino , Refluxo Gastroesofágico/etiologia , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Fatores de Risco
2.
Dis Esophagus ; 22(8): 656-63, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19515186

RESUMO

Laparoscopic Nissen fundoplication (LNF) is an effective treatment for gastroesophageal reflux disease; however, some patients develop dysphagia postoperatively. Manometry is used to evaluate disorders of peristalsis, but has not been proven useful to identify which patients may be at risk for postoperative dysphagia. Multichannel intraluminal impedance (MII) evaluates the effective clearance of a swallowed bolus through the esophagus. We hypothesized that MII combined with manometry may detect those patients most at risk of developing dysphagia after LNF. Between March 2003 and January 2007, 74 patients who agreed to participate in this study were prospectively enrolled. All patients completed a preoperative symptom questionnaire, MII/manometry, and 24-h pH monitoring. All patients underwent LNF. Symptom questionnaires were administered postoperatively at a median of 18 months (range: 6-46 months), and we defined dysphagia (both preoperatively and postoperatively) as occurring more than once a month with a severity >or=4 (0-10 Symptom Severity Index). Thirty-two patients (43%) reported preoperative dysphagia, but there was no significant difference in pH monitoring, lower esophageal sphincter pressure/relaxation, peristalsis, liquid or viscous bolus transit (MII), or bolus transit time (MII) between patients with and without preoperative dysphagia. In those patients reporting preoperative dysphagia, the severity of dysphagia improved significantly from 6.8 +/- 2 to 2.6 +/- 3.4 (P < 0.001) after LNF. Thirteen (17%) patients reported dysphagia postoperatively, 10 of whom (75%) reported some degree of preoperative dysphagia. The presence of postoperative dysphagia was significantly more common in patients with preoperative dysphagia (P= 0.01). Patients with postoperative dysphagia had similar lower esophageal sphincter pressure and relaxation, peristalsis, and esophageal clearance to those without dysphagia. Neither MII nor manometry predicts dysphagia in patients with gastroesophageal reflux disease or its occurrence after LNF. The presence of dysphagia preoperatively is the only predictor of dysphagia after LNF.


Assuntos
Transtornos de Deglutição/etiologia , Monitoramento do pH Esofágico , Fundoplicatura/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Transtornos de Deglutição/diagnóstico , Impedância Elétrica , Feminino , Fundoplicatura/métodos , Determinação da Acidez Gástrica , Humanos , Laparoscopia , Masculino , Manometria , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA