Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Transfusion ; 63(6): 1204-1214, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37119513

RESUMO

BACKGROUND: In Japan, plasma with a high concentration of Hepatitis B Virus (HBV) antibodies for hepatitis B immunoglobulin (HBIG) is almost entirely imported. We aimed to produce recombinant HBIG by isolating immunoglobulin cDNAs against the HBV surface antigen (HBsAg). STUDY DESIGN AND METHODS: B cells expressing HBsAg antibodies were obtained from blood center personnel who had been administered HB vaccine booster and then isolated by either an Epstein-Barr virus hybridoma or an antigen-specific memory B cell sorting method. Each cDNA of the heavy and light chains of the target antibody was cloned into an IgG1 expression vector and transfected into Expi293F cells to produce a recombinant monoclonal antibody (mAb), which was screened by ELISA and in vitro HBV neutralizing assays. The cross-reactivity of the mAbs to normal human molecules was evaluated by ELISA and immunohistochemistry. RESULTS: Antibody cDNAs were cloned from 11 hybridoma cell lines and 204 HBsAg-bound memory B cells. Three of the resulting recombinant mAbs showed stronger neutralizing activity in vitro than the currently used HBIG. All three bind to the conformational epitope(s) of HBsAg but not to human DNA or cells. DISCUSSION: We successfully isolated HBV-neutralizing monoclonal antibodies from B cells collected from healthy plasma donors boosted against the HBV. To obtain an alternative source for HBIG, HBV-neutralizing monoclonal antibodies from B cells collected from healthy plasma donors boosted against the HBV may be useful.


Assuntos
Infecções por Vírus Epstein-Barr , Hepatite B , Humanos , Antígenos de Superfície da Hepatite B , Vírus da Hepatite B/genética , Estudos de Viabilidade , Herpesvirus Humano 4 , Vacinas contra Hepatite B , Anticorpos Anti-Hepatite B , Anticorpos Monoclonais , Proteínas Recombinantes , Hepatite B/prevenção & controle
2.
Vox Sang ; 117(1): 49-57, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34082471

RESUMO

BACKGROUND AND OBJECTIVES: Platelet concentrates suspended in a platelet additive solution (PAS-PC) are associated with a reduction in allergic response and are suitable for preparing pathogen-inactivated PC. We aimed to develop an efficient platform for the dual preparation of PAS-PC and platelet-poor plasma. MATERIALS AND METHODS: PAS-PC was prepared in six steps by using a hollow-fibre system based on cross-flow filtration: priming, loading PC, loading PAS, collection of filtered liquid (flow-through) and collection of platelets by washing with PAS followed by washing with air. In this study, the efficacy of platelet and plasma protein recovery and characteristics of recovered PAS-PC and flow-through plasma were analysed in detail. RESULTS: Recoveries of platelet in PAS-PC and plasma protein in the flow-through were 95.4% ± 3.7% and 61.6% ± 5.0%, respectively. The residual plasma protein in PAS-PC was 34.1% ± 2.8%. Although the expression level of CD62P, a platelet activation marker, in recovered platelets was approximately 1.2-fold of that in original platelets, swirling patterns were well retained, and aggregation in PAS-PC was not visible. Agonist-induced aggregabilities, platelet morphology and hypotonic shock recovery were conserved. The patterns of plasma protein and lipoprotein in the flow-through were comparable with those in the original PCs. The multimeric pattern analysis of VWF remained unaltered. CONCLUSION: We propose a highly efficient preparation system that enables the simultaneous production of PAS-PC and platelet-poor plasma. It also achieves a high recovery of functionally well-retained platelets with very low activation.


Assuntos
Preservação de Sangue , Ativação Plaquetária , Plaquetas , Humanos , Pressão Osmótica , Plasma
3.
PLoS One ; 16(5): e0251650, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34014978

RESUMO

The risk of sepsis through bacterial transmission is one of the most serious problems in platelet transfusion. In processing platelet concentrates (PCs), several methods have been put into practice to minimize the risk of bacterial transmission, such as stringent monitoring by cultivation assays and inactivation treatment by photoirradiation with or without chemical agents. As another potential option, we applied a light-emitting diode (LED) with a peak emission wavelength of 265 nm, which has been shown to be effective for water, to disinfect PCs. In a bench-scale UV-LED exposure setup, a 10-min irradiation, corresponding to an average fluence of 9.2 mJ/cm2, resulted in >2.0 log, 1.0 log, and 0.6 log inactivation (mean, n = 6) of Escherichia coli, Staphylococcus aureus, and Bacillus cereus, respectively, in non-diluted plasma PCs. After a 30-min exposure, platelet counts decreased slightly (18 ± 7%: mean ± SD, n = 7); however, platelet surface expressions of CD42b, CD61, CD62P, and PAC-1 binding did not change significantly (P>0.005), and agonist-induced aggregation and adhesion/aggregation under flow conditions were well maintained. Our findings indicated that the 265 nm UV-LED has high potential as a novel disinfection method to ensure the microbial safety of platelet transfusion.


Assuntos
Bactérias/crescimento & desenvolvimento , Plaquetas , Desinfecção , Viabilidade Microbiana/efeitos da radiação , Raios Ultravioleta , Plaquetas/metabolismo , Plaquetas/microbiologia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA