Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Open Vet J ; 13(5): 645-653, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37304606

RESUMO

Background: Rupture of the common calcaneal tendon is the second most frequent tendon rupture in dogs and may lead to severe lameness and pain. Surgical repair consists of re-apposition of the damaged tendon ends using sutures, but this type of repair is not always possible especially if the tendon has retracted. Tendon augmentation with an ultra-high molecular weight polyethylene (UHMWPE) implant is a recent solution to support the sutures and allow the repair of the canine calcaneal tendon. However, its biomechanical fixation strength remains untested for this pathology. Aim: To evaluate the biomechanical fixation strength of a UHMWPE implant for the repair of the canine calcaneal tendon. Methods: Ex-vivo biomechanical study was carried out on eight cadaveric hindlimbs from four adult dogs. Hindlimbs were tested under two independent modalities: proximal tendinous fixation (PTF) and distal calcaneus fixation (DCF), using a testing machine. PTF was achieved by eight simple interrupted polypropylene sutures performed through the UHMWPE implant. The latter was sandwiched inside the gastrocnemius tendon, which had previously been incised over about 5 cm longitudinally, and through the tendon of the superficial digital flexor. DCF was performed using an interference screw, which locked the UHMWPE implant into a calcaneus tunnel drilled perpendicularly. Results: Yield, failure load, and linear stiffness (mean ± SD) for the DCF modality were 920 ± 139 N, 1,007 ± 146 N, and 92 ± 15.21, respectively, which were greater than for the PTF modality (663 ± 92 N, 685 ± 84 N and 25.71 ± 5.74, respectively, p < 0.05). Failure modes were different between fixation modalities: for PTF it was suture breakage (n = 7/8), while for DCF it was implant damage and slippage (n = 8/8). Conclusion: The biomechanical fixation strength of the UHMWPE implant was greater for DCF than that of PTF, and should be suitable for calcaneal tendon repair in dogs. The clinical prediction of rupture of this calcaneal tendon repair will occur at the level of the PTF.


Assuntos
Tendão do Calcâneo , Canidae , Doenças do Cão , Traumatismos dos Tendões , Cães , Animais , Tendão do Calcâneo/cirurgia , Traumatismos dos Tendões/cirurgia , Traumatismos dos Tendões/veterinária , Suturas/veterinária , Parafusos Ósseos/veterinária
2.
Am J Vet Res ; 83(11): 1-8, 2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36136932

RESUMO

OBJECTIVE: To compare ex vivo postimplantation biomechanical characteristics of 3 implants for canine total hip replacement: a cementless press-fit femoral stem with a pin in the femoral neck (p-pfFS), a press-fit cementless femoral stem without this pin (pfFS), and a cemented femoral stem (cFS). SAMPLE: 18 cadaveric femurs from 9 dogs. PROCEDURES: Femurs were assigned randomly to 3 groups, and biomechanical testing was performed by measuring vertical displacement during cyclic loading and resistance to failure with compression parallel to the longitudinal axis of the femur. Force-displacement curves were assessed for failure tests, and work necessary for failure was calculated. RESULTS: No significant differences were observed in vertical displacement during cyclic loading (P = .263) or work necessary for failure (P = .079). Loads to failure for cFS and p-pfFS implants were significantly greater than that for the pfFS, but no significant difference in load to failure was observed between cFS and p-pfFS implants (P = .48). CLINICAL RELEVANCE: Cementless femoral stems with a transfixation pin offer significantly greater immediate resistance to failure to compressive loads parallel to the longitudinal axis of the femur than standard cementless stems, and a level of stability comparable to that of cemented stems. p-pfFS implants may be valuable in total hip replacement, potentially reducing the risk of fracture during the early postoperative period prior to osteointegration.


Assuntos
Artroplastia de Quadril , Doenças do Cão , Prótese de Quadril , Cães , Animais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/veterinária , Prótese de Quadril/veterinária , Desenho de Prótese/veterinária , Fêmur/cirurgia , Doenças do Cão/cirurgia
3.
Open Vet J ; 12(3): 341-350, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35821774

RESUMO

Background: Cranial cruciate ligament rupture (CCLr) is the most common cause of hind limb lameness in dogs. Currently, surgical management of CCLr is mostly performed using tibial osteotomy techniques to modify the biomechanical conformation of the affected stifle. These surgical techniques have a significant complication rate, associated with persistent instability of the stifle which may lead to chronic postoperative pain. Over the last decade, studies have been published on various techniques of anatomical caudal cruciate ligament reconstruction in veterinary practice, using physiological autografts or woven synthetic implants. Aim: The aim of this ex vivo biomechanical study is to investigate the ex vivo dynamic biomechanical behavior of a synthetic implant [ultrahigh molecular weight polyethylene (UHMWPE) implant] fixed with interference screws for the treatment of CCLr in dogs, according to a fatigue protocol (48 hours per test). Methods: Seven stifles from four skeletally mature canine cadavers were implanted with the synthetic implant. It was fixed with four interference screws inserted in transversal and oblique tunnels in both the distal femur and the proximal tibia. For each case, 100,000 cycles were performed at 0.58 Hz, with traction loads ranging from 100 to 210 N. Results: Neither screw-bone assembly rupture nor a pull-out issue was observed during the dynamic tests. Linear stiffness of the implants associated with a fixation system with four interference screws increased over time. The final displacement did not exceed 3 mm for five of the seven specimens. Five of the seven synthetic implants yielded to a lengthening in functional range (0-3 mm). Linear stiffness was homogeneous among samples, showing a strong dynamic strength of the interference screw-based fixations of the UHMWPE implant in the femoral and tibial bones. Conclusion: This study completes the existing literature on the biomechanical evaluation of passive stifle stabilization techniques with a testing protocol focused on cyclic loading at a given force level instead of driven by displacement. These biomechanical results should revive interest in intra-articular reconstruction after rupture of the CCLr in dogs.


Assuntos
Lesões do Ligamento Cruzado Anterior , Doenças do Cão , Animais , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/veterinária , Fenômenos Biomecânicos , Parafusos Ósseos/veterinária , Cães , Joelho de Quadrúpedes/cirurgia
4.
Vet Surg ; 51(8): 1247-1256, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35675144

RESUMO

OBJECTIVE: To describe the mechanical characteristics of a novel angle-stable interlocking nail (NAS-ILN) and compare them to those of a locking compression plate (LCP) by using a gap-fracture model. STUDY DESIGN: Experimental study. SAMPLE POPULATION: Synthetic bone models. METHODS: Synthetic bone models simulating a 50 mm diaphyseal comminuted canine tibial fracture were treated with either a novel angle-stable interlocking nail (NAS-ILN) or a locking compression plate (LCP). Maximal axial deformation and load to failure in compression and 4-point bending, as well as maximal angular deformation, slack, and torque to failure in torsion, were statistically compared (P < .05). RESULTS: In compression, the maximal axial deformation was lower for NAS-ILN (0.11 mm ± 0.03) than for LCP (1.10 mm ± 0.22) (P < .0001). The ultimate load to failure was higher for NAS-ILN (803.58 N ± 29.52) than for LCP (328.40 N ± 11.01) (P < .0001). In torsion, the maximal angular deformation did not differ between NAS-ILN (22.79° ± 1.48) and LCP (24.36° ± 1.45) (P = .09). The ultimate torque to failure was higher for NAS-ILN (22.45 Nm ± 0.24) than for LCP (19.10 Nm ± 1.36) (P = .001). No slack was observed with NAS-ILN. In 4-point bending, the maximal axial deformation was lower for NAS-ILN (3.19 mm ± 0.49) than for LCP (4.17 mm ± 0.34) (P = .003). The ultimate bending moment was higher for NAS-ILN (25.73 Nm, IQR [23.54-26.86] Nm) than for LCP (16.29 Nm, IQR [15.66-16.47] Nm) (P = .002). CONCLUSION: The NAS-ILN showed greater stiffness in compression and 4-point bending, and a greater resistance to failure in compression, torsion, and 4-point bending, than LCP. CLINICAL IMPACT: Based on these results, NAS-ILNs could be considered as alternative implants for the stabilization of comminuted fractures.


Assuntos
Doenças do Cão , Fraturas Ósseas , Fraturas Cominutivas , Cães , Animais , Fixação Interna de Fraturas/veterinária , Fixação Interna de Fraturas/métodos , Fenômenos Biomecânicos , Placas Ósseas/veterinária , Fraturas Ósseas/veterinária , Pinos Ortopédicos/veterinária , Fraturas Cominutivas/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA