Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
1.
Int J Cardiol ; : 132231, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38838745

RESUMO

BACKGROUND: Extensive ablation in addition to pulmonary vein isolation (PVI) in patients with persistent atrial fibrillation (AF) has not yielded consistent results, indicating diversity in their efficacy. Mitral regurgitation (MR) associated with AF may indicate a higher prevalence of arrhythmogenic substrate, suggesting potential benefits of extensive ablation for these patients. METHODS: This post-hoc analysis of the EARNEST-PVI trial compared PVI alone versus an extensive ablation strategy (PVI-plus) in persistent AF patients, stratified by MR presence. The primary endpoint of the study was the recurrence of AF. The secondary endpoints included death, cerebral infarction, and procedure-related complications. RESULTS: The trial included 495 eligible patients divided into MR and non-MR groups. The MR group consisted of 192 patients (89 in the PVI-alone arm and 103 in the PVI-plus arm), while the non-MR group had 303 patients (158 in the PVI-alone arm and 145 in the PVI-plus arm). In the non-MR group, recurrence rates were similar between PVI-alone and PVI-plus arms (Log-rank P = 0.47, Hazard ratio = 0.85 [95%CI: 0.54-1.33], P = 0.472). However, in the MR group, PVI-plus was significantly more effective in preventing AF recurrence (Log-rank P = 0.0014, Hazard ratio = 0.40 [95%CI: 0.22-0.72], P = 0.0021). No significant differences were observed in secondary endpoints between the two arms. CONCLUSIONS: For persistent AF patients with mild or greater MR, receiving PVI-plus was superior to PVI-alone in preventing AF recurrence. Conversely, for patients without MR, the effectiveness of extensive ablation was not demonstrated. These findings suggest tailoring ablation strategies based on MR presence can lead to better outcomes in AF management.

2.
Circ J ; 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38811199

RESUMO

BACKGROUND: It has not been fully elucidated which patients with persistent atrial fibrillation (PerAF) should undergo substrate ablation plus pulmonary vein isolation (PVI). This study aimed to identify PerAF patients who required substrate ablation using intraprocedural assessment of the baseline rhythm and the origin of atrial fibrillation (AF) triggers.Methods and Results: This was a post hoc subanalysis using extended data of the EARNEST-PVI trial, a prospective multicenter randomized trial comparing PVI-alone and PVI-plus (i.e., PVI with added catheter ablation) arms. We divided 492 patients into 4 groups according to baseline rhythm and the location of AF triggers before PVI: Group A (n=22), sinus rhythm with pulmonary vein (PV)-specific AF triggers (defined as reproducible AF initiation from PVs only); Group B (n=211), AF with PV-specific AF triggers; Group C (n=94), sinus rhythm with no PV-specific AF trigger; Group D (n=165), AF with no PV-specific AF trigger. Among the 4 groups, only in Group D (AF at baseline and no PV-specific AF triggers) was arrhythmia-free survival significantly lower in the PVI-alone than PVI-plus arm (P=0.032; hazard ratio 1.68; 95% confidence interval 1.04-2.70). CONCLUSIONS: Patients with sinus rhythm or PV-specific AF triggers did not receive any benefit from substrate ablation, whereas patients with AF and no PV-specific AF trigger benefited from substrate ablation.

3.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38767127

RESUMO

AIMS: Understanding of the tissue cooling properties of cryoballoon ablation during pulmonary vein (PV) isolation is lacking. The purpose of this study was to delineate the depth of the tissue cooling effect during cryoballoon freezing at the pulmonary venous ostium. METHODS AND RESULTS: A left atrial-PV model was constructed using a three-dimensional printer with data from a patient to which porcine thigh muscle of various thicknesses could be affixed. The model was placed in a 37°C water tank with a PV water flow at a rate that mimicked biological blood flow. Cryofreezing at the PV ostium was performed five times each for sliced porcine thigh muscle of 2, 4, and 6 mm thickness, and sliced muscle cooling on the side opposite the balloon was monitored. The cooling effect was assessed using the average temperature of 12 evenly distributed thermocouples covering the roof region of the left superior PV. Tissue cooling effects were in the order of the 2, 4, and 6 mm thicknesses, with an average temperature of -41.4 ± 4.2°C for 2 mm, -33.0 ± 4.0°C for 4 mm, and 8.0 ± 8.7°C for 6 mm at 180 s (P for trend <0.0001). In addition, tissue temperature drops were steeper in thin muscle (maximum temperature drop per 5 s: 5.2 ± 0.9°C, 3.9 ± 0.7°C, and 1.3 ± 0.7°C, P for trend <0.0001). CONCLUSION: The cooling effect of cryoballoon freezing is weaker in the deeper layers. Cryoballoon ablation should be performed with consideration to myocardial thickness.


Assuntos
Criocirurgia , Veias Pulmonares , Criocirurgia/métodos , Criocirurgia/instrumentação , Criocirurgia/efeitos adversos , Animais , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Suínos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Humanos , Modelos Cardiovasculares , Músculo Esquelético/cirurgia , Modelos Anatômicos
4.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38691672

RESUMO

AIMS: Blood stasis is crucial in developing left atrial (LA) thrombi. LA appendage peak flow velocity (LAAFV) is a quantitative parameter for estimating thromboembolic risk. However, its impact on LA thrombus resolution and clinical outcomes remains unclear. METHODS AND RESULTS: The LAT study was a multicentre observational study investigating patients with atrial fibrillation (AF) and silent LA thrombi detected by transoesophageal echocardiography (TEE). Among 17 436 TEE procedures for patients with AF, 297 patients (1.7%) had silent LA thrombi. Excluding patients without follow-up examinations, we enrolled 169 whose baseline LAAFV was available. Oral anticoagulation use increased from 85.7% at baseline to 97.0% at the final follow-up (P < 0.001). During 1 year, LA thrombus resolution was confirmed in 130 (76.9%) patients within 76 (34-138) days. Conversely, 26 had residual LA thrombi, 8 had thromboembolisms, and 5 required surgical removal. These patients with failed thrombus resolution had lower baseline LAAFV than those with successful resolution (18.0 [15.8-22.0] vs. 22.2 [17.0-35.0], P = 0.003). Despite limited predictive power (area under the curve, 0.659; P = 0.001), LAAFV ≤ 20.0 cm/s (best cut-off) significantly predicted failed LA thrombus resolution, even after adjusting for potential confounders (odds ratio, 2.72; 95% confidence interval, 1.22-6.09; P = 0.015). The incidence of adverse outcomes including ischaemic stroke/systemic embolism, major bleeding, or all-cause death was significantly higher in patients with reduced LAAFV than in those with preserved LAAFV (28.4% vs. 11.6%, log-rank P = 0.005). CONCLUSION: Failed LA thrombus resolution was not rare in patients with AF and silent LA thrombi. Reduced LAAFV was associated with failed LA thrombus resolution and adverse clinical outcomes.


Assuntos
Anticoagulantes , Apêndice Atrial , Fibrilação Atrial , Ecocardiografia Transesofagiana , Trombose , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/complicações , Masculino , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Idoso , Trombose/fisiopatologia , Trombose/diagnóstico por imagem , Trombose/complicações , Pessoa de Meia-Idade , Velocidade do Fluxo Sanguíneo , Anticoagulantes/uso terapêutico , Fatores de Risco , Resultado do Tratamento , Doenças Assintomáticas , Fatores de Tempo , Cardiopatias/fisiopatologia , Cardiopatias/complicações , Cardiopatias/diagnóstico por imagem , Tromboembolia/etiologia , Tromboembolia/fisiopatologia , Idoso de 80 Anos ou mais , Função do Átrio Esquerdo
5.
Am J Cardiol ; 218: 43-50, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38479607

RESUMO

Low-voltage areas have been used as atrial structural substrates in estimating fibrotic degeneration in patients with atrial fibrillation (AF). The high-resolution maps obtained by recently developed mapping catheters allow the visualization of several functional abnormalities. We investigated the association between left atrial (LA) functional abnormal findings on a high-resolution substrate map and AF recurrence in patients who underwent pulmonary vein isolation without any additional LA substrate ablation. This observational study included 100 consecutive patients who underwent second ablation for AF (paroxysmal, 48%; persistent, 52%). Patients with extra-pulmonary-vein LA substrate ablation during the initial and second ablation were excluded. LA mapping was performed using a 64-pole mini-basket catheter on the RHYTHMIA mapping system (Boston Scientific, Marlborough [Cambridge] Massachusetts). Patients were followed for 2 years. AF recurrence developed in 39 (39%) patients. On the high-resolution substrate map, AF recurrence was associated with the presence of the following findings: low-voltage areas (<1.0 mV, >5 cm2; hazard ratio [HR] = 2.53; 95% confidence interval [CI] = 1.30 to 4.93; p <0.006), fractionated-electrogram areas (≥5 peaks, >5 cm2; HR = 2.15, 95% CI = 1.10 to 4.19; p = 0.025), LA conduction time of >130 ms (HR = 3.11, 95% CI = 1.65 to 5.88, p <0.0001), deceleration zone (≥5 isochrones/cm2; HR = 1.97, 95% CI = 1.04 to 3.37, p = 0.039), and multiple septal break-out points (HR = 3.27, 95% CI = 1.50 to 7.16, p = 0.003). Accumulation of these risk factors increased AF recurrence in a stepwise manner, with an HR = 1.90, 95% CI = 1.44 to 2.52, p <0.00001 for each additional risk factor. In conclusion, a high-resolution map revealed new LA functional substrates associated with AF recurrence. Implementation of functional substrates may improve the prediction of AF recurrence after ablation, and possibly aid the development of tailored AF ablation strategies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Átrios do Coração , Frequência Cardíaca , Fatores de Risco , Ablação por Cateter/efeitos adversos , Recidiva , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 35(4): 775-784, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38375957

RESUMO

INTRODUCTION: Left atrial low-voltage areas (LVAs) are known to be correlated with atrial scarring and atrial fibrillation (AF) recurrence after ablation. However, the association between LVAs and glycemic status before ablation has not been fully clarified. The purpose of this study was to investigate associations among the prevalence of diabetes mellitus (DM), glycemic control, and the prevalence of LVAs in patients with AF ablation. METHODS: In total, 912 (age, 68 ± 10 years; female, 299 [33%]; persistent AF, 513 [56%]) consecutive patients who underwent initial AF ablation were included. A preprocedure glycated hemoglobin A1c (HbA1c) ≥7% was set as the cutoff for poor glycemic control in patients with DM. LVAs were defined as areas with a bipolar voltage of <0.5 mV covering ≥5 cm2 of left atrium. RESULTS: LVAs existed in 208 (23%) patients, and 168 (18%) patients had DM. LVAs were found more frequently in patients with DM and poor glycemic control. On multivariate analysis, DM with HbA1c ≥7% was an independent predictor of LVAs (odds ratio, 3.3; 95% confidence interval: 1.6-6.7; p = .001). In patients with LVAs, freedom from AF recurrence during the 24-month study period was significantly lower in patients who had DM with HbA1c ≥7% than in those without DM (37.9% vs. 54.7%, p = .02). CONCLUSION: In patients with AF ablation, LVAs were found more frequently in patients with DM and poor glycemic control. DM with HbA1c ≥7% was an independent predictor of LVAs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Diabetes Mellitus , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Prevalência , Hemoglobinas Glicadas , Controle Glicêmico , Átrios do Coração/cirurgia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva , Resultado do Tratamento
7.
Heart Rhythm ; 21(6): 733-740, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38307310

RESUMO

BACKGROUND: The optimal duration of atrial fibrillation (AF) persistence for predicting poor outcomes after catheter ablation of long-standing AF (LsAF) and the best ablation strategy for these patients remain unclear. OBJECTIVE: We aimed to assess the impact of the duration of AF persistence on outcomes after catheter ablation of AF. METHODS: We analyzed the Efficacy of Pulmonary Vein Isolation Alone in Patients with Persistent Atrial Fibrillation (EARNEST-PVI) trial data comparing pulmonary vein isolation (PVI) alone (PVI-alone) with additional linear ablation or defragmentation (PVI-plus) in persistent AF (PerAF). Patients who received catheter ablation by contact force-sensing catheter were enrolled in the study. In patients with LsAF, the optimal cutoff duration of AF persistence was evaluated. With use of the threshold, patients with LsAF were divided into 2 groups and compared with PerAF <1 year for arrhythmia-free survival after a 3-month blanking period. RESULTS: The optimal cutoff duration was 2.4 years. Of 458 patients, arrhythmia-free survival rates for LsAF 1-2.4 years were comparable to those of PerAF (hazard ratio [HR], 1.01; 95% CI, 0.67-1.52). However, LsAF >2.4 years had a higher recurrence risk than PerAF (HR, 2.22; 95% CI, 1.42-3.47). In LsAF >2.4 years, the PVI-plus strategy showed advantages over the PVI-alone strategy (HR, 0.36; 95% CI, 0.14-0.89). However, the interaction effect between LsAF 1-2.4 years and LsAF >2.4 years did not reach statistical significance (P = .116). CONCLUSION: Whereas LsAF 1-2.4 years has similar outcomes to those of PerAF, LsAF >2.4 years was linked to higher arrhythmia recurrence risks. For LsAF >2.4 years, the PVI-plus strategy showed a potential to be superior to the PVI-alone strategy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Fatores de Tempo , Resultado do Tratamento , Idoso , Fatores de Risco , Seguimentos
8.
Sci Rep ; 14(1): 2634, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38302547

RESUMO

Identifying patients who would benefit from extensive catheter ablation along with pulmonary vein isolation (PVI) among those with persistent atrial fibrillation (AF) has been a subject of controversy. The objective of this study was to apply uplift modeling, a machine learning method for analyzing individual causal effect, to identify such patients in the EARNEST-PVI trial, a randomized trial in patients with persistent AF. We developed 16 uplift models using different machine learning algorithms, and determined that the best performing model was adaptive boosting using Qini coefficients. The optimal uplift score threshold was 0.0124. Among patients with an uplift score ≥ 0.0124, those who underwent extensive catheter ablation (PVI-plus) showed a significantly lower recurrence rate of AF compared to those who received only PVI (PVI-alone) (HR 0.40; 95% CI 0.19-0.84; P-value = 0.015). In contrast, among patients with an uplift score < 0.0124, recurrence of AF did not significantly differ between PVI-plus and PVI-alone (HR 1.17; 95% CI 0.57-2.39; P-value = 0.661). By employing uplift modeling, we could effectively identify a subset of patients with persistent AF who would benefit from PVI-plus. This model could be valuable in stratifying patients with persistent AF who need extensive catheter ablation before the procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Resultado do Tratamento , Recidiva , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos
9.
J Cardiol ; 83(5): 298-305, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37802202

RESUMO

BACKGROUND: Percutaneous left atrial appendage closure (LAAC) has increased for those who need alternative to long-term anticoagulation with non-valvular atrial fibrillation (NVAF). METHODS AND RESULTS: From September 2019, after initiating WATCHMAN (Boston Scientific, Maple Grove, MN, USA) device implantation, we established Transcatheter Modification of Left Atrial Appendage by Obliteration with Device in Patients from the NVAF (TERMINATOR) registry. Utilizing 729 patients' data until January 2022, we analyzed percutaneous LAAC data regarding this real-world multicenter prospective registry. A total of 729 patients were enrolled. Average age was 74.9 years and 28.5 % were female. Paroxysmal AF was 37.9 % with average CHADS2 3.2, CHA2DS2-VASc 4.7, and HAS-BLED score of 3.4. WATCHMAN implantation was successful in 99.0 %. All-cause deaths were 3.2 %, and 1.2 % cardiovascular or unexplained deaths occurred during follow-up [median 222, interquartile range (IQR: 93-464) days]. Stroke occurred in 2.2 %, and the composite endpoint which included cardiovascular or unexplained death, stroke, and systemic embolism were counted as 3.4 % [median 221, (IQR: 93-464) days]. Major bleeding defined as BARC type 3 or 5 was seen in 3.7 %, and there was 8.6 % of all bleeding events in total [median 219, (IQR: 93-464) days]. CONCLUSIONS: These preliminary data demonstrated percutaneous LAAC with WATCHMAN device might have a potential to reduce stroke and bleeding events for patients with NVAF. Further investigation is mandatory to confirm the long-term results of this strategy using this transcatheter local therapy instead of life-long systemic anticoagulation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Feminino , Idoso , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Apêndice Atrial/cirurgia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Anticoagulantes , Sistema de Registros , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 35(1): 171-181, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38018401

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is accompanied by various types of remodeling, including volumetric enlargement and histological degeneration. Electrical remodeling reportedly reflects histological degeneration. PURPOSE: To clarify the differences in determinants and clinical impacts among types of remodeling. METHODS: This observational study included 1118 consecutive patients undergoing initial ablation for AF. Patients were divided into four groups: minimal remodeling (left atrial volume index [LAVI] < mean value and no low-voltage area [LVA], n = 477); volumetric remodeling (LAVI ≥ mean value and no LVA, n = 361); electrical remodeling (LAVI < mean value and LVA presence, n = 96); and combined remodeling (LAVI ≥ mean value and LVA presence, n = 184). AF recurrence and other clinical outcomes were followed up for 2 and 5 years, respectively. RESULTS: Major determinants of each remodeling pattern were high age for electrical (odds ratio = 2.32, 95% confidence interval = 1.68-3.25) and combined remodeling (2.57, 1.88-3.49); female for electrical (3.85, 2.21-6.71) and combined remodeling (4.92, 2.90-8.25); persistent AF for combined remodeling (7.09, 3.75-13.4); and heart failure for volumetric (1.71, 1.51-2.53) and combined remodeling (2.21, 1.30-3.75). Recurrence rate after initial ablation increased in the order of minimal remodeling (20.1%), volumetric (27.4%) or electrical remodeling (36.5%), and combined remodeling (50.0%, p < .0001). A composite endpoint of heart failure, stroke, and death occurred in the order of minimal (3.4%), volumetric (7.5%) or electrical (8.3%), and combined remodeling (15.2%, p < .0001). CONCLUSION: Volumetric, electrical, and combined remodeling were each associated with a unique patient background, and defined rhythm and other clinical outcomes.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Remodelamento Atrial , Insuficiência Cardíaca , Feminino , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Recidiva , Resultado do Tratamento , Masculino
11.
Pacing Clin Electrophysiol ; 47(1): 28-35, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38029377

RESUMO

BACKGROUND: Recently, a new OCTARAY® mapping catheter was commercially launched. The catheter is designed to enable high-density mapping and precise signal recording via 48 small electrodes arranged on eight radiating splines. The purpose of this study was to compare bipolar voltage and low-voltage-area size, and mapping efficacy between the OCTARAY catheter and the PENTARAY® catheter METHODS: Twelve consecutive patients who underwent initial and second ablations for persistent atrial fibrillation within 2 years were considered for enrollment. Voltage mapping was performed twice, first during the initial ablation using the PENTARY catheter and second during the second ablation using the OCTARAY Long 3-3-3-3-3 (L3) catheter. RESULTS: Mean voltage with the OCTARAY-L3 catheter (1.64 ± 0.57 mV) was 32.3% greater than that with the PENTARAY catheter (1.24 ± 0.46 mV, p < .0001) in total left atrium. Low-voltage-area (<0.50 mV) size with the OCTARAY-L3 catheter was smaller than that with the PENTARAY catheter (6.9 ± 9.7 vs. 11.4 ± 13.0 cm2 , p < .0001). The OCTARAY-L3 catheter demonstrated greater efficacy than the PENTARAY catheter in terms of shorter mapping time (606 ± 99 vs. 782 ± 211 s, p = .008) and more mapping points (3,026 ± 838 vs. 781 ± 342 points, p < .0001). CONCLUSION: The OCTARAY catheter demonstrated higher voltage recordings, narrower low-voltage areas, and a more efficacious mapping procedure than the PENTARAY catheter.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Técnicas Eletrofisiológicas Cardíacas , Ablação por Cateter/métodos , Fibrilação Atrial/cirurgia , Átrios do Coração , Catéteres
12.
Heart Rhythm ; 21(4): 378-386, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38157922

RESUMO

BACKGROUND: Atrial cardiomyopathy is known as an underlying pathophysiological factor in the majority of patients with atrial fibrillation (AF). Left atrial low-voltage areas (LVAs) are reported to coincide with fibrosis and likely represent atrial cardiomyopathy. OBJECTIVE: The purpose of this study was to delineate differences in the long-term prognosis of patients stratified by the size of LVAs. METHODS: This observational study included 1488 consecutive patients undergoing initial ablation for AF. LVAs were defined as regions with a bipolar peak-to-peak voltage <0.50 mV. The total study population was divided into 3 groups stratified by LVA size: patients with no LVAs (n = 1136); those with small (<20 cm2) LVAs (n = 250) LVAs; and those with extensive (≥20 cm2) LVAs (n = 102). Composite endpoints of death, heart failure, and stroke were followed for up to 5 years. RESULTS: Composite endpoints developed in 105 of 1488 patients (7.1%), and AF recurrence occurred in 410 (27.6%). Composite endpoints developed more frequently in the order of patients with extensive LVAs (19.1%), small LVAs (10.8%), and no LVAs (5.1%) (P for trend <.0001). Multivariable analysis revealed that LVA presence was independently associated with higher incidence of composite endpoints, irrespective of AF recurrence (modified hazard ratio 1.73; 95% confidence interval 1.13-2.64; P = .011) CONCLUSION: LVA presence and its extent both were associated with poor long-term composite endpoints of death, heart failure, and stroke, irrespective of AF recurrence or other confounders. Underlying atrial cardiomyopathy seems to define a poor prognosis after AF ablation.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Insuficiência Cardíaca , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Prognóstico , Seguimentos , Átrios do Coração , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Ablação por Cateter/efeitos adversos , Recidiva
13.
J Am Heart Assoc ; 12(17): e029651, 2023 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-37642022

RESUMO

Background An optimal strategy for left atrial ablation in addition to pulmonary vein isolation (PVI) in patients with persistent atrial fibrillation (AF) has not been determined. Methods and Results We conducted an extended follow-up of the multicenter randomized controlled EARNEST-PVI (Efficacy of Pulmonary Vein Isolation Alone in Patients With Persistent Atrial Fibrillation) trial, which compared 12-month rhythm outcomes in patients with persistent AF between patients randomized to a PVI-alone strategy (n=248) or PVI-plus strategy (n=248; PVI followed by left atrial additional ablation, including linear ablation or ablation targeting areas with complex fractionated electrograms). The present study extended the follow-up period to 3 years after enrollment. Outcomes were compared not only between randomly allocated groups but also between on-treatment groups categorized by actually created ablation lesions. Recurrence rate of AF or atrial tachycardia (AT) was lower in the randomly allocated to PVI-plus group than the PVI-alone group (29.0% versus 37.5%, P=0.036). On-treatment analysis revealed that patients with PVI+linear ablation (n=205) demonstrated a lower AF/AT recurrence rate than those with PVI only (26.3% versus 37.8%, P=0.007). In contrast, patients with PVI+complex fractionated electrograms ablation (n=37) had an AF/AT recurrence rate comparable to that of patients with PVI only (40.5% versus 37.8%, P=0.76). At second ablation in 126 patients with AF/AT recurrence, ATs excluding common atrial flutter were more frequent in patients with PVI+linear ablation than in those with PVI only (32.6% versus 5.7%, P<0.0001). Conclusions Left atrial ablation in addition to PVI was efficacious during 3-year follow-up. Linear ablation was superior to other ablation strategies but may increase iatrogenic ATs. Registration URL: http://www.umin.ac.jp/ctr/index-j.htm; Unique identifier: UMIN000019449.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Flutter Atrial , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Átrios do Coração , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia
14.
Am J Cardiol ; 203: 37-44, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37481810

RESUMO

Atrial myocardial degeneration predisposes to atrial fibrillation (AF), ischemic stroke, and heart failure. Studies suggest the presence of gender differences in atrial myocardial degeneration. This study aimed to delineate gender differences in the prevalence, predictors, and prognostic impact of left atrial low-voltage areas (LVAs). This observational study included 1,488 consecutive patients who underwent initial ablation for AF. Voltage mapping was performed after pulmonary vein isolation during sinus rhythm. LVAs were defined as regions where bipolar peak-to-peak voltage was <0.50 mV. LVA prevalence was higher in women (38.7%) than in men (16.0%). High age, persistent form of AF, diabetes mellitus, and a large left atrium were shown to be common predictors in both gender categories. Heart failure and history of stroke/thromboembolic events were men-specific predictors of LVA existence. Women experienced more AF recurrence than men (31.1% vs 25.7%, p = 0.027). LVA existence was significantly associated with increased AF recurrence in each gender category, with a respective hazard ratio, 95% confidence interval, and p value of 2.45, 1.87 to 3.22, and <0.0001 in men and 1.82, 1.33 to 2.49, and <0.0001 in women. In conclusion, LVA was more frequent in women than men, and predicted frequent AF recurrence irrespective of gender category.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Insuficiência Cardíaca , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Fatores Sexuais , Átrios do Coração , Fibrose , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
15.
J Cardiovasc Med (Hagerstown) ; 24(8): 544-551, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37161971

RESUMO

AIMS: Atrial natriuretic peptide (ANP) deficiency is thought to be one of the causes of heart failure induced by atrial fibrillation (AF). Although ANP deficiency is thought to occur as a result of atrial remodeling, data to explain this mechanism are limited. The purpose of this study was to investigate the association between ANP and left atrial remodeling or prognosis of heart failure in patients with AF ablation. METHODS: In total, 373 consecutive patients who underwent initial ablation for persistent AF [age, 67 ±â€Š10 years; female, 97 (26%)] were retrospectively enrolled. ANP and brain natriuretic peptide (BNP) were measured before the procedure and the ANP/BNP ratio was calculated. Left atrial volume index, left atrial appendage emptying velocity, and left atrial low-voltage areas (LVAs) were used as left atrial-remodeling parameters. The primary outcome of heart failure was defined as the composite of all-cause death or hospitalization due to worsening heart failure. RESULTS: The median ANP level was 116 (71-178) pg/ml and the median ANP/BNP ratio was 0.65 (0.46-1.00). The ANP/BNP ratio decreased with increasing left atrial volume index or LVAs and with decreasing left atrial appendage emptying velocity. During the 5-year follow-up, freedom from the primary outcome was significantly lower in patients with ANP/BNP ratio ≤0.65 than in those with ANP/BNP ratio >0.65 (84.6% versus 95.6%, P  < 0.01). CONCLUSION: Secretion of ANP relative to BNP decreased with progression of left atrial remodeling in patients with AF ablation. Furthermore, prognosis of heart failure was poor in patients with a low ANP/BNP ratio.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Insuficiência Cardíaca , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Fator Natriurético Atrial , Insuficiência Cardíaca/etiologia , Peptídeo Natriurético Encefálico , Estudos Retrospectivos , Masculino
16.
J Cardiol Cases ; 27(5): 241-244, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37180222

RESUMO

Deep brain stimulation (DBS) is a well-established therapy for drug-refractory Parkinson's disease. As 100-200 Hz signals from DBS are transmitted from the generator implanted subcutaneously in the anterior chest wall, there is a risk of central nervous system damage by radiofrequency energy or cardioversion. A 76-year-old female with a DBS was admitted for catheter ablation because of palpitation and syncope by paroxysmal atrial fibrillation. There may have been a risk of central nervous system damage and DBS electrode malfunction by radiofrequency energy and defibrillation shocks. In addition, cardioversion by an external defibrillator had the possibility to cause brain injury in patients with DBS. Therefore, pulmonary vein isolation by cryoballoon and cardioversion using an intracardiac defibrillation catheter were performed. Despite continued application of DBS during the procedure, no complications occurred. This is the first case report of cryoballoon ablation accompanied with intracardiac defibrillation under continued DBS. Cryoballoon ablation may be an alternative atrial fibrillation ablation method to radiofrequency catheter ablation for patients with DBS. Additionally, intracardiac defibrillation may reduce the risk of central nervous system damage and DBS malfunction. Learning objective: Deep brain stimulation (DBS) is a well-established therapy for Parkinson's disease. In patients with DBS, there is a risk of central nervous system damage by radiofrequency energy or cardioversion by an external defibrillator. Cryoballoon ablation may be an alternative atrial fibrillation ablation method to radiofrequency catheter ablation for patients with continued DBS. In addition, intracardiac defibrillation may reduce the risk of central nervous system damage and DBS malfunction.

17.
J Interv Card Electrophysiol ; 66(7): 1713-1721, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36765021

RESUMO

BACKGROUND: Isolation of the pulmonary veins (PVs) is the golden standard for atrial fibrillation (AF) ablation. To achieve a permanent PV isolation, the endoscopic guided HeartLight laser balloon system was invented. We analyzed the safety and efficacy of this laser balloon system. METHODS AND RESULTS: Three hundred four patients from 21 investigational sites inside Japan were enrolled in this study. One thousand sixty-two out of 1175 PVs (90.4%) were isolated using the HeartLight laser balloon. The isolation rate of the left superior, left inferior, right superior, and right inferior PVs was 87.8%, 91.3%, 91.6%, and 92.1%, respectively. The procedure time, defined as the time from the venous access to taking out the balloon, was 155 ± 39 min. The fluoroscopic time was 44 ± 25 min. The mean follow-up period was 309 ± 125 days. The freedom from AF recurrence at 3 months was 89.0% and at 12 months 82.1%. Adverse events occurred in 22 patients (7.2%) including phrenic nerve injury lasting more than 3 months in 1.6% and strokes in 1.0% of the patients. CONCLUSIONS: This initial experience demonstrated that the laser balloon ablation was feasible for PV isolation in Japanese AF patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Resultado do Tratamento , Japão , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Lasers , Endoscopia , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos
19.
Circ J ; 87(3): 432-429, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36624062

RESUMO

BACKGROUND: Although favorable clinical outcomes have been demonstrated for fluoropolymer-based paclitaxel-eluting stents (FP-DES) in the treatment of femoropopliteal lesions, the vascular response after implantation has not been systematically studied through intravascular imaging.Methods and Results: We angioscopically compared FP-DES: 24 in the early phase (mean [±SD] 3±1 months), 26 in the middle phase (12±3 months), and 20 in the late phase (≥18 months) after implantation. The dominant neointimal coverage grade, heterogeneity of neointimal coverage grade, and thrombus adhesion in the stent segment were evaluated. Neointimal coverage was graded as follows: Grade 0, stent struts exposed; Grade 1, struts bulging into the lumen, although covered; Grade 2, struts embedded in the neointima, but visible; Grade 3, struts fully embedded and invisible. Dominant neointimal coverage and heterogeneity grades were significantly higher in the middle and late phases than in the early phase (all P<0.05), but did not differ significantly between the middle and late phases. The incidence of thrombus adhesion was recorded for all stents in each of the 3 different phases. CONCLUSIONS: The middle and late phases after FP-DES implantation were associated with significantly higher dominant neointimal coverage and heterogeneity grades than the early phase. However, thrombus adhesion was observed in all phases after FP-DES implantation. Arterial healing may not be completed even in the late phase after FP-DES implantation.


Assuntos
Stents Farmacológicos , Trombose , Humanos , Polímeros de Fluorcarboneto , Angioscopia/métodos , Artéria Femoral , Neointima/patologia , Trombose/patologia , Vasos Coronários/patologia , Resultado do Tratamento
20.
J Endovasc Ther ; 30(2): 269-280, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35249409

RESUMO

PURPOSE: Although the size of drug-coated balloons (DCBs) is determined according to the vessel diameter during femoropopliteal (FP)-endovascular therapy (EVT), the measurements of the vessel diameter vary among modalities and its definitions. The aim of this study was to reveal whether the DCB size fitting (1) angiographically-measured lumen diameter (Angio-lumen size), (2) intravascular ultrasound (IVUS)-measured lumen diameter (IVUS-lumen size), or (3) IVUS-measured external elastic membrane (EEM) diameter (IVUS-EEM size) would be beneficial in restenosis occurrence. MATERIALS AND METHODS: This retrospective, single-center study included 231 de novo FP lesions in 165 patients with peripheral artery disease treated with IN.PACT Admiral DCB under IVUS evaluation. The reference vessel diameter was evaluated as the lumen or EEM diameter at the healthy site distal to the lesion. We retrospectively determined whether the DCB size was close to (ie, equal to or different by <0.5 mm from) Angio-lumen size, IVUS-lumen size, and IVUS-EEM size. The association of the size of DCB with restenosis risk was investigated. RESULTS: The mean lesion length was 13 ± 9 cm and the prevalence of chronic total occlusion was 18%. During a mean follow-up period of 17 ± 9 months, restenosis occurred in 26% of lesions. Lesions treated with a DCB of IVUS-EEM size had a lower 2 year restenosis rate than those treated with a DCB over/under IVUS-EEM size (19.7 ± 5.7% vs 34.5 ± 4.7%, p=0.02 by the log-rank test), while the restenosis rate was not significantly different between DCBs of Angio-lumen size or IVUS-lumen size and those over/under the size (both p>0.05). The multivariate Cox regression analysis revealed that DCBs of IVUS-EEM size were independently associated with a reduced risk of restenosis (adjusted hazard ratio 0.50; 95% confidence interval 0.27-0.95; p=0.03). CONCLUSION: The DCBs of IVUS-EEM size, but not of Angio-lumen size or IVUS-lumen size, were associated with a reduced risk of restenosis after FP-EVT. Determining the DCB size according to IVUS-evaluated EEM diameter would be potentially beneficial in restenosis occurrence.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Humanos , Artéria Poplítea/diagnóstico por imagem , Estudos Retrospectivos , Angioplastia com Balão/efeitos adversos , Resultado do Tratamento , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Materiais Revestidos Biocompatíveis , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA