Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Biophotonics ; 16(12): e202100392, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37551154

RESUMO

Optical coherence tomography (OCT) is a promising tool for intraoperative tissue morphology determination. Several studies suggest that attenuation coefficient derived from the OCT images, can differentiate between tissues of different morphology, such as normal and pathological structures of the brain, skin, and other tissues. In the present study, the depth-resolved method for attenuation coefficient calculation was adopted for the real-world situation of the depth-dependent OCT sensitivity and additive imaging noise with nonzero mean. It was shown that in the case of sharp focusing (~10 µm spot full width at half maximum [FWHM] or smaller at 1.3 µm central wavelength) only the proposed method for depth-dependent sensitivity compensation does not introduce misleading artifacts into the calculated attenuation coefficient distribution. At the same time, the scanning beam focus spot with FWHM greater than 10 µm at 1.3 µm central wavelength allows one to use multiple approaches to the attenuation coefficient calculation without introducing noticeable bias. This feature may hinder the need for robust corrections for the depth-resolved attenuation coefficient estimations from the community.


Assuntos
Pele , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Encéfalo/diagnóstico por imagem , Algoritmos , Carmustina
2.
J Biophotonics ; 13(10): e202000112, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32639647

RESUMO

A method for numerical estimation and correction of aberrations of the eye in fundus imaging with optical coherence tomography (OCT) is presented. Aberrations are determined statistically by using the estimate based on likelihood function maximization. The method can be considered as an extension of the phase gradient autofocusing algorithm in synthetic aperture radar imaging to 2D optical aberration correction. The efficacy of the proposed method has been demonstrated in OCT fundus imaging with 6λ aberrations. After correction, single photoreceptors were resolved. It is also shown that wave front distortions with high spatial frequencies can be determined and corrected.


Assuntos
Algoritmos , Tomografia de Coerência Óptica , Fundo de Olho , Funções Verossimilhança
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA