Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
PLoS One ; 18(2): e0282462, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36848353

RESUMO

A number of restricted diffusion (RD) imaging techniques, such as diffusion kurtosis (DK) imaging and Q space imaging, have been developed and proven to be useful for the diagnosis of diseases, including cerebral gliomas and cerebrovascular infarction. In particular, apparent diffusion coefficient (ADC) subtraction method (ASM) imaging has become available recently as a novel RD imaging technique. ASM is based on the difference between the ADC values in an image pair of two ADC maps, ADC basic (ADCb) and ADC modify (ADCm), which are created from diffusion-weighted images taken using short and long effective diffusion times, respectively. The present study aimed to assess the potential of different types of ASM imaging by comparing them with DK imaging which is the gold-standard RD imaging technique. In the present basic study using both polyethylene glycol phantom and cell-containing bio-phantom, three different types of ASM images were created using different calculation processes. ASM/A is an image calculated by dividing the absolute difference between ADCb and ADCm by ADCb several times. By contrast, ASM/S is an image created by dividing the absolute difference between ADCb and ADCm by the standard deviation of ADCb several times. As for positive ASM/A image (PASM/A), the positive image, which was resultant after subtracting ADCb from ADCm, was divided by ADCb several times. A comparison was made between the types of ASM and DK images. The results showed the same tendency between ASM/A in addition to both ASM/S and PASM/A. By increasing the number of divisions by ADCb from three to five times, ASM/A images transformed from DK-mimicking to more RD-sensitive images compared with DK images. These observations suggest that ASM/A images may prove useful for future clinical applications in RD imaging protocols for the diagnosis of diseases.


Assuntos
Imagem de Tensor de Difusão , Técnica de Subtração , Difusão , Imagens de Fantasmas
2.
Acta Med Okayama ; 76(6): 731-736, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36549776

RESUMO

We report a rare case of idiopathic spinal cord herniation (ISCH) with a history of cerebrospinal fluid (CSF) leakage. ISCH is a protrusion of the spinal cord through a dural defect. Thin constructive interference in steady-state (CISS) images clearly demonstrated the herniated cord in the present case. The myelopathy worsened and the patient underwent surgery for reduction of herniated spinal cord; the dural defect was filled by placing collagen matrix graft (DuraGen®) between the inner and outer dural layers. The patient's symptoms have improved without relapse for 8 months since surgery. This method may be a good surgical option for cases of spinal cord herniation.


Assuntos
Doenças da Medula Espinal , Vértebras Torácicas , Humanos , Vértebras Torácicas/cirurgia , Hérnia , Doenças da Medula Espinal/cirurgia , Doenças da Medula Espinal/diagnóstico , Herniorrafia/métodos , Imageamento por Ressonância Magnética
3.
Acta Med Okayama ; 76(3): 297-305, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35790360

RESUMO

Clinical research using restricted diffusion-weighted imaging, especially diffusion kurtosis (DK) imaging, has been progressing, with reports on its effectiveness in the diagnostic imaging of cerebral infarctions, neurodegenerative diseases, and tumors, among others. However, the application of DK imaging in daily clinical practice has not spread because of the long imaging time required and the use of specific software for image creation. Herein, with the aim of promoting clinical research using DK imaging at any medical facility, we evaluated fast DK imaging using a new software program. We developed a new macro program that produces DK images using general-purpose, inexpensive software (Microsoft Excel and ImageJ), and we evaluated fast DK imaging using bio-phantoms and a healthy volunteer in clinical trials. The DK images created by the new software with diffusion-weighted images captured with short-time imaging sequences were similar to the original DK images captured with long-time imaging sequences. The DK images using three b-values, which can reduce the imaging time by 43%, were equivalent to the DK images using five b-values. The DK imaging technique developed herein might allow any medical facility to increase its daily clinical use of DK imaging and easily conduct clinical research.


Assuntos
Imagem de Difusão por Ressonância Magnética , Software , Difusão , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Imagens de Fantasmas
4.
Acta Med Okayama ; 75(2): 139-145, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33953420

RESUMO

Diffusion-weighted imaging may be used to obtain the apparent diffusion coefficient (ADC), which aids the diagnosis of cerebral infarction and tumors. An ADC reflects elements of free diffusion. Diffusion kurtosis imaging (DKI) has attracted attention as a restricted diffusion imaging technique. The ADC subtraction method (ASM) was developed to visualize restricted diffusion with high resolution by using two ADC maps taken with different diffusion times. We conducted the present study to provide a bridge between the reported basic ASM research and clinical research. We developed new imaging software for clinical use and evaluated its performance herein. This software performs the imaging process automatically and continuously at the pixel level, using ImageJ software. The new software uses a macro or a plugin which is compatible with various operating systems via a Java Virtual Machine. We tested the new imaging software's performance by using a Jurkat cell bio-phantom, and the statistical evaluation of the performance clarified that the ASM values of 99.98% of the pixels in the bio-phantom and physiological saline were calculated accurately (p<0.001). The new software may serve as a useful tool for future clinical applications and restricted diffusion imaging research.


Assuntos
Imagem de Tensor de Difusão/instrumentação , Animais , Células Cultivadas , Imagens de Fantasmas , Software
5.
Biomed Rep ; 13(6): 52, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33082949

RESUMO

The present study aimed to investigate whether polyethylene glycol (PEG) phantoms have the potential to be used as standard phantoms for magnetic resonance imaging (MRI) in order to visualize restricted diffusion in diffusion kurtosis imaging (DKI), the ADC subtraction method (ASM) and the apparent diffusion coefficient (ADC). Diffusion-weighted images of 0-120 mM PEG phantoms were captured to create ADC, DKI and ASM images with post-processing. ASM is a recently developed method for restricted diffusion imaging using the readout segmentation of long variable echo-train sequences. As the PEG concentration increases, the ADC value decreases. Conversely, an increase in DKI and ASM values is associated with increasing PEG concentration. Formulae were constructed to represent the association between PEG concentrations and ADC, DKI and ASM values. These formulae can be used to determine the required PEG concentrations to mimic arbitrary ADC, DKI and ASM values of certain diseases, including tumors and infarctions. Validation experiments were conducted using bio-phantoms and clarified that the PEG phantoms cover the range of ADC and DKI values reported in previous clinical research using 3T MRI. PEG phantoms may be useful for future MRI research involving restricted diffusion.

7.
Artigo em Japonês | MEDLINE | ID: mdl-32684562

RESUMO

In pediatric cardiac cine magnetic resonance imaging (MRI), it must overcome several challenges including the patient's size and higher heart rate. The aim of this study was to retrospectively evaluate imaging optimization. Cardiac cine MRI data from 24 patients was analyzed (age range: 3 months-10 years, average age: 5 years, male/female: 11/13, R-R interval: 450±4 to 819±7 ms). About 11 cases out of 24 have good image quality. For small variations in the R-R interval and higher temporal resolution improved image quality with significant difference (P<0.05, Mann-Whitney U-test). In this study, values of temporal resolution <30 ms yielded good image quality for heart rates over 100 bpm. On the other hands, the factors dependent on the patient like heart rate and ejection fraction have no significant difference. The segmentation of data acquisition is more significant than recording small fields of view or thin slices for infantile and pediatric cardiac cine MRI. Similar to adult cases, variations in heart rate affect the image quality; however, we demonstrated that using segmentation of data acquisition results in improved image quality.


Assuntos
Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Adulto , Algoritmos , Criança , Pré-Escolar , Feminino , Frequência Cardíaca , Humanos , Aumento da Imagem , Lactente , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
J Interv Cardiol ; 2020: 9509105, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32410917

RESUMO

OBJECTIVE: The aim of this study was to examine the relationship between right ventricular (RV) volume and exercise capacity in adult patients with atrial septal defect (ASD) and to determine the degree of RV dilatation for transcatheter ASD closure. BACKGROUND: RV dilatation is an indication of transcatheter ASD closure; however, few studies have reported the clinical significance of RV dilatation. METHODS: We enrolled 82 consecutive patients (mean age, 49 ± 18 years; female, 68%) who underwent cardiac magnetic resonance imaging and symptom-limited cardiopulmonary exercise test before ASD closure. The relationship between RV volume and peak oxygen uptake (VO2) was evaluated. RESULTS: The mean RV end-diastolic volume index was 108 ± 27 ml/m2 (range, 46 to 180 ml/m2). The mean peak VO2 was 24 ± 7 ml/min/kg (range, 14 to 48 ml/min/kg), and the mean predicted peak VO2 was 90 ± 23%. There were significant negative relationships of RV end-diastolic volume index with peak VO2 (r = -0.28, p < 0.01) and predicted peak VO2 (r = -0.29, p < 0.01). The cutoff value of RV end-diastolic volume index <80% of predicted peak VO2 was 120 ml/m2, with the sensitivity of 49% and the specificity of 89%. CONCLUSIONS: There was a relationship between RV dilatation and exercise capacity in adult patients with ASD. RV end-diastolic volume index ≥120 ml/m2 was related to the reduction in peak VO2. This criterion of RV dilatation may be valuable for the indication of transcatheter ASD closure.


Assuntos
Tolerância ao Exercício , Comunicação Interatrial , Ventrículos do Coração , Adulto , Correlação de Dados , Teste de Esforço/métodos , Feminino , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Seleção de Pacientes
9.
Eur Radiol Exp ; 4(1): 4, 2020 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-31993864

RESUMO

BACKGROUND: To reveal trends in bone microarchitectural parameters with increasing spatial resolution on ultra-high-resolution computed tomography (UHRCT) in vivo and to compare its performance with that of conventional-resolution CT (CRCT) and micro-CT ex vivo. METHODS: We retrospectively assessed 5 tiger vertebrae ex vivo and 16 human tibiae in vivo. Seven-pattern and four-pattern resolution imaging were performed on tiger vertebra using CRCT, UHRCT, and micro-CT, and on human tibiae using UHRCT. We measured six microarchitectural parameters: volumetric bone mineral density (vBMD), trabecular bone volume fraction (bone volume/total volume, BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N), trabecular separation (Tb.Sp), and connectivity density (ConnD). Comparisons between different imaging resolutions were performed using Tukey or Dunnett T3 test. RESULTS: The vBMD, BV/TV, Tb.N, and ConnD parameters showed an increasing trend, while Tb.Sp showed a decreasing trend both ex vivo and in vivo. Ex vivo, UHRCT at the two highest resolutions (1024- and 2048-matrix imaging with 0.25-mm slice thickness) and CRCT showed significant differences (p ≤ 0.047) in vBMD (51.4 mg/cm3 and 63.5 mg/cm3 versus 20.8 mg/cm3), BV/TV (26.5% and 29.5% versus 13.8 %), Tb.N (1.3 l/mm and 1.48 l/mm versus 0.47 l/mm), and ConnD (0.52 l/mm3 and 0.74 l/mm3 versus 0.02 l/mm3, respectively). In vivo, the 512- and 1024-matrix imaging with 0.25-mm slice thickness showed significant differences in Tb.N (0.38 l/mm versus 0.67 l/mm, respectively) and ConnD (0.06 l/mm3 versus 0.22 l/mm3, respectively). CONCLUSIONS: We observed characteristic trends in microarchitectural parameters and demonstrated the potential utility of applying UHRCT for microarchitectural analysis.


Assuntos
Coluna Vertebral/ultraestrutura , Tíbia/ultraestrutura , Tomografia Computadorizada por Raios X , Microtomografia por Raio-X , Animais , Densidade Óssea , Humanos , Técnicas In Vitro , Tigres
10.
Mol Med Rep ; 20(3): 2963-2969, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31524240

RESUMO

In order to visualize restricted diffusion, the present study developed a novel method called 'apparent diffusion coefficient (ADC) subtraction method (ASM)' and compared it with diffusion kurtosis imaging (DKI). The diffusion-weighted images of physiological saline, in addtion to bio-phatoms of low cell density and the highest cell density were obtained using two sequences with different effective diffusion times. Then, the calculated ADC values were subtracted. The mean values and standard deviations (SD) of the ADC values of physiological saline, low cell density and the highest cell density phantoms were 2.95±0.08x10­3, 1.90±0.35x10­3 and 0.79±0.05x10­3 mm2/sec, respectively. The mean kurtosis values and SD of DKI were 0.04±0.01, 0.44±0.13 and 1.27±0.03, respectively. The ASM and SD values were 0.25±0.20x104, 0.51±0.41x104 and 4.80±4.51x104 (sec/mm2)2, respectively. Using bio­phantoms, the present study demonstrated that DKI exhibits restricted diffusion in the extracellular space. Similarly, ASM may reflect the extent of restricted diffusion in the extracellular space.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/normas , Humanos , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Reprodutibilidade dos Testes
11.
J Radiat Res ; 60(4): 483-489, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31083713

RESUMO

This study aimed to compare the interobserver variabilities in magnetic resonance imaging (MRI)/computed tomography (CT) fusion image-based post-implant dosimetry of permanent prostate brachytherapy (PPB) between 1.5-T and 3.0-T MRI. The study included 60 patients. Of these patients, 30 underwent 1.5-T MRI and CT 30 days after seed implantation (1.5-T group), and 30 underwent 3.0-T MRI and CT 30 days after seed implantation (3.0-T group). All patients received PPB alone. Two radiation oncologists performed MRI/CT fusion image-based post-implant dosimetry, and the interobserver variabilities of dose-volume histogram (DVH) parameters [dose (Gy) received by 90% of the prostate volume (prostate D90)], percentage of the prostate volume receiving at least the full prescribed dose (prostate V100), percentage of the prostate volume receiving at least 150% of the prescribed dose (prostate V150), dose (Gy) received by 5% of the urethral volume (urethral D5) and the urethral volume receiving at least 150% of the prescribed dose (urethral V150)] were retrospectively estimated using the paired Student's t test and Pearson's correlation coefficient. The Pearson's correlation coefficients of all DVH parameters were higher in the 3.0-T group than in the 1.5-T group (1.5-T vs 3.0-T: prostate D90, 0.65 vs 0.93; prostate V100, 0.62 vs 0.82; prostate V150, 0.97 vs 0.98; urethral D5, 0.92 vs 0.93; and urethral V150, 0.88 vs 0.93). In the paired Student's t test, no significant differences were observed in any of the DVH parameters between the two radiation oncologists in the 3.0-T group (0.068 ≤ P ≤ 0.842); however, significant differences were observed in prostate D90 (P = 0.004), prostate V100 (P = 0.011) and prostate V150 (P = 0.002) between the oncologists in the 1.5-T group. The interobserver variability of DVH parameters in the MRI/CT fusion image-based post-implant dosimetry analysis of brachytherapy was lower with 3.0-T MRI than with 1.5-T MRI.


Assuntos
Braquiterapia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiometria , Relação Dose-Resposta à Radiação , Humanos , Imageamento por Ressonância Magnética , Masculino , Variações Dependentes do Observador , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X , Uretra/efeitos da radiação
12.
Artigo em Japonês | MEDLINE | ID: mdl-30662032

RESUMO

Brain T1-weighted images using spin echo (SE) sequence has poor contrast at 3.0 Tesla magnetic resonance imaging (3.0 T MRI) systems from the influence of crosstalk and magnetized transfer (MT) effect, and prolongation of the T1 value. Therefore, improving of scan parameters has been reported such as excitation flip angle (FA) and interleave data acquisition. The purpose of this study was to show the effects of alterations of presaturation pulse amplitude and chemical shift selective (CHESS) pulse amplitude. Gray-to-white matter contrast increased with decreasing amplitude of presaturation pulse in whole brain imaging. Presaturation and CHESS pulse consist of radio frequency pulse. Therefore, both pulses have a similar effect on MT pulse. Manual alteration of presaturation pulse amplitude for each scan lacks versatility on clinical use. However, decreasing amplitude of presaturation pulse is equal to decreasing thickness of presaturation pulse. About CHESS pulse, it requires no manual alteration for each scan. For example, switching fat suppression mode from strong to weak increase T1 contrast. Our study demonstrated that using not only low excitation FA and interleave date acquisition but also low amplitude of presaturation and CHESS pulse increase the contrast in T1 SE brain scans at 3.0 T MRI.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Humanos , Aumento da Imagem
13.
Acta Med Okayama ; 72(1): 53-59, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29463939

RESUMO

Readout-segmented echo-planar imaging (RESOLVE) is a multi-shot echo-planar imaging (EPI) modality with k-space segmented in the readout direction. We investigated whether RESOLVE decreases the distortion and artifact in the phase direction and increases the signal-to-noise ratio (SNR) in phantoms image taken with 3-tesla (3T) MRI versus conventional EPI. We used a physiological saline phantom and subtraction mapping and observed that RESOLVE's SNR was higher than EPI's. Using RESOLVE, the combination of a special-purpose coil and a large-loop coil had a higher SNR compared to using only a head/neck coil. RESOLVE's image distortioas less than EPI's. We used a 120 mM polyethylene glycol phantom to examine the phase direction artifact.vThe range where the artifact appeared in the apparent diffusion coefficient (ADC) image was shorter with RESOLVE compared to EPI. We used RESOLVE to take images of a Jurkat cell bio-phantom: the cell-region ADC was 856×10-6mm2/sec and the surrounding physiological saline-region ADC was 2,951×10-6mm2/sec. The combination of RESOLVE and the 3T clinical MRI device reduced image distortion and improved SNR and the identification of accurate ADC values due to the phase direction artifact reduction. This combination is useful for obtaining accurate ADC values of bio-phantoms.


Assuntos
Artefatos , Imagem Ecoplanar , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Humanos , Células Jurkat
14.
Acta Med Okayama ; 71(2): 105-112, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28420891

RESUMO

We retrospectively assessed the dual-time-point (DTP) F-18 FDG PET/CT findings of thymic epithelial neoplasms (TENs) and investigated the diagnostic capacity of PET/CT compared to that of CT for predicting carcinoma. We calculated the ratio of the standardized uptake value of the tumor and that of the aortic arch (T/M ratio) for both the 90-min early scan and the 2-h delayed scan in 56 TEN patients. We used a multivariate logistic regression (MLR) analysis to estimate the CT features of carcinoma. We compared the diagnostic capacities of PET/CT and chest CT using receiver operating characteristic (ROC) analyses. The ROC curve revealed that the appropriate cut-off T/M ratio value for the highest accuracy was 2.39 with 75.0% accuracy. The area under the curve (AUC) was 0.855. The statistical analyses for DTP scans of 35 TEN patients demonstrated 74.3% accuracy and 0.838 AUC for the early scan versus 82.9% and 0.825 for the delayed scan. The MLR analysis indicated that mediastinal fat infiltration was a predictor of carcinoma. The ROC curve obtained for the model yielded an AUC of 0.853. Delayed scanning could improve the diagnostic capacity for carcinoma. The T/M ratio and mediastinal fat infiltration are predictive of carcinoma with moderate diagnostic accuracy.


Assuntos
Neoplasias Epiteliais e Glandulares/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias do Timo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Epiteliais e Glandulares/classificação , Neoplasias Epiteliais e Glandulares/patologia , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Método Simples-Cego , Neoplasias do Timo/classificação , Neoplasias do Timo/patologia , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
16.
J Radiat Res ; 52(5): 680-4, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21857148

RESUMO

Computed tomography (CT)/magnetic resonance imaging (MRI) fusion is considered to be the best method for postimplant dosimetry of permanent prostate brachytherapy; however, it is inconvenient and costly. In T2*-weighted image (T2*-WI), seeds can be easily detected without the use of an intravenous contrast material. We present a novel method for postimplant dosimetry using T2*-WI/T2-weighted image (T2-WI) fusion. We compared the outcomes of T2*-WI/T2-WI fusion-based and CT/T2-WI fusion-based postimplant dosimetry. Between April 2008 and July 2009, 50 consecutive prostate cancer patients underwent brachytherapy. All the patients were treated with 144 Gy of brachytherapy alone. Dose-volume histogram (DVH) parameters (prostate D90, prostate V100, prostate V150, urethral D10, and rectal D2cc) were prospectively compared between T2*-WI/T2-WI fusion-based and CT/T2-WI fusion-based dosimetry. All the DVH parameters estimated by T2*-WI/T2-WI fusion-based dosimetry strongly correlated to those estimated by CT/T2-WI fusion-based dosimetry (0.77 ≤ R ≤ 0.91). No significant difference was observed in these parameters between the two methods, except for prostate V150 (p = 0.04). These results show that T2*-WI/T2-WI fusion-based dosimetry is comparable or superior to MRI-based dosimetry as previously reported, because no intravenous contrast material is required. For some patients, rather large differences were observed in the value between the 2 methods. We thought these large differences were a result of seed miscounts in T2*-WI and shifts in fusion. Improving the image quality of T2*-WI and the image acquisition speed of T2*-WI and T2-WI may decrease seed miscounts and fusion shifts. Therefore, in the future, T2*-WI/T2-WI fusion may be more useful for postimplant dosimetry of prostate brachytherapy.


Assuntos
Braquiterapia , Neoplasias da Próstata/radioterapia , Humanos , Radioisótopos do Iodo/administração & dosagem , Radioisótopos do Iodo/uso terapêutico , Imageamento por Ressonância Magnética , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
17.
Acta Med Okayama ; 62(3): 159-68, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18596832

RESUMO

With the aim of sequence optimization in susceptibility-weighted imaging (SWI), 2 image acquisition parameters (slice thickness and matrix size) and 2 image processing conditions (number of slices per minimum intensity projection (MIP) and Sliding Window) were investigated using a 1.5-T magnetic resonance imaging (MRI) system. The subjects were 12 healthy volunteers and the target region for scanning was the whole brain. Informed consent was obtained from all subjects. First, susceptibility-weighted images were acquired with various slice thicknesses from 1mm to 5mm and various matrix sizes from 256 x 256 to 512 x 512, and the images were assessed in terms of the contrast-to-noise ratio (CNR) and were also visually evaluated by three radiologists. Then, the number of slices per MIP and the usefulness of the Sliding Window were investigated. In the study of the optimal slice thickness and matrix size, the results of visual evaluation suggested that a slice thickness of 3mm and a matrix size of 448 x 448 are optimal, while the results of evaluation based on CNR were not significant. As regards the image processing conditions, the results suggested that the number of slices per MIP should be set to a minimum value of 2 and that the use of Sliding Window is effective. The present study provides useful reference data for optimizing SWI sequences.


Assuntos
Encéfalo/patologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Modelos Biológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA