Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Bioanalysis ; 14(12): 853-863, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35703321

RESUMO

Gene therapy, cell therapy and vaccine research have led to an increased use of qPCR/ddPCR in bioanalytical laboratories. CROs are progressively undertaking the development and validation of qPCR and ddPCR assays. Currently, however, there is limited regulatory guidance for the use of qPCR and a complete lack of any regulatory guidelines for the use of the newer ddPCR to support regulated bioanalysis. Hence, the Global CRO Council in Bioanalysis (GCC) has issued this White Paper to provide; 1) a consensus on the different validation parameters required to support qPCR/ddPCR assays; 2) a harmonized approach to their validation and 3) a consistent development of standard operating procedures (SOPs) for all the bioanalytical laboratories using these techniques.


Assuntos
Bioensaio , Reação em Cadeia da Polimerase em Tempo Real/métodos
4.
Bioanalysis ; 13(21): 1645-1651, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34657485

RESUMO

Multiparametric flow cytometry is a powerful cellular analysis tool used in various stages of drug development. In adoptive cell therapies, the flow cytometry methods are used for the evaluation of advanced cellular products during manufacturing and to monitor cellular kinetics after infusion. In this report, we discussed the bioanalytical method development challenges to monitor cellular kinetics in CAR-T cell therapies. These method development challenges include procuring positive control samples for the development of the method, flow cytometry panel design, LLOQ, prestain sample stability, staining reagents and data analysis.


Assuntos
Citometria de Fluxo , Imunoterapia Adotiva , Linfócitos T/citologia , Humanos , Cinética , Receptores de Antígenos Quiméricos/imunologia , Linfócitos T/imunologia
5.
Bioanalysis ; 13(10): 841-846, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33890498

RESUMO

Flow cytometer is a powerful cellular analysis tool consists of three main components; fluidics, optics and electronics. Flow cytometry methods have been used in all stages of drug development as like ligand binding assays (LBA). Both LBA and flow cytometry methods require specific interaction between the critical reagents and the analytes. Antibodies and their conjugates, viable dyes and permeabilizing buffer are the main critical reagents in flow cytometry methods. Similarly, antibodies, engineered proteins and their conjugates are the main critical reagents in LBA. The main difference between the two methods is the lack of true reference standards for flow cytometry cellular analysis.


Assuntos
Desenvolvimento de Medicamentos/métodos , Descoberta de Drogas/métodos , Citometria de Fluxo/métodos , Humanos
6.
Bioanalysis ; 12(4): 221-229, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32083489

RESUMO

Aim: Globally, neurodegeneration accounts for significant morbidity and mortality among the elderly. Millions of people are afflicted with neurodegenerative diseases, with the most notable cases attributed to Alzheimer's, Huntington's, amyotrophic lateral sclerosis and Parkinson's diseases. Sensitive assays that can detect proteopathic anomalies indicative of early neurodegeneration have remained elusive. Therefore, there is an urgent need for sensitive diagnostic and prognostic biomarker assays that can guide the therapeutic regimen in the clinic. Materials & methods: Single molecule array digital immunoassay platform has sensitivity about 1000-fold higher than traditional ligand binding assays. Consequently, we are now beginning to implement ultrasensitive techniques in bioanalysis. Conclusion: In the current study, we evaluated single molecule array technology and report specifications to quantitate neurofilament light chain, a bona-fide biomarker for neurodegeneration. Preliminary neurofilament light screening results from 100 human geriatric cerebrospinal fluid samples displayed huge biological variation and warrants further investigation.


Assuntos
Imunoensaio/métodos , Testes Imunológicos/métodos , Proteínas de Neurofilamentos/metabolismo , Humanos
7.
Hum Vaccin Immunother ; 10(10): 2965-74, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25483632

RESUMO

The glutathione S-transferase (GST)-L1 multiplex serology assay has favorable properties for use in clinical trials and epidemiologic studies, including low cost, high throughput capacity, and low serum volume requirement. Therefore, we evaluated the GST-L1 assay as a measure of HPV16/18 vaccine immunogenicity. Our study population included 65 women selected from the Costa Rica Vaccine Trial who received the bivalent HPV16/18 virus-like particle (VLP) vaccine at the recommended 0/1/6-month schedule. We tested replicate serum samples from months 0/1/12 (i.e., after 0/1/3 doses) by GST-L1 and 3 other commonly used serology assays, VLP-ELISA, SEAP-NA, and cLIA. We calculated the percentage of women seropositive by GST-L1 by time point and HPV type (14 HPV types), and compared GST-L1 to other assays using Spearman rank correlation coefficients. After 1 vaccine dose, seropositivity by GST-L1 was 40% each for HPV16 and HPV18, increasing to 100% and 98%, respectively, after 3 doses. Seropositivity after 3 doses ranged from 32% to 69% for HPV types 31/33/45, for which partial vaccine efficacy is reported, though increases also occurred for types with no evidence for cross-protection (e.g., HPV77). GST-L1 correlated best after 3 doses with VLP-ELISA (HPV16 and HPV18 each ρ = 0.72) and SEAP-NA (HPV16 ρ = 0.65, HPV18 ρ = 0.71) (all P < 0.001); correlation was lower with cLIA. The GST-L1 is suitable for evaluating HPV16/18 vaccine immunogenicity after 3 vaccine doses, although in contrast to other assays it may classify some samples as HPV16/18 seronegative. The assay's utility is limited for lower antibody levels such as after receipt of 1 dose.


Assuntos
Bioensaio/métodos , Papillomavirus Humano 16/imunologia , Papillomavirus Humano 18/imunologia , Infecções por Papillomavirus/imunologia , Vacinas contra Papillomavirus/imunologia , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Formação de Anticorpos/imunologia , Costa Rica , Proteção Cruzada , Feminino , Glutationa Transferase/metabolismo , Humanos , Imunização Secundária , Infecções por Papillomavirus/prevenção & controle , Reprodutibilidade dos Testes , Vacinação
8.
Hum Vaccin Immunother ; 10(8): 2168-74, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25424920

RESUMO

In the clinical trials of the quadrivalent human papillomavirus (qHPV) vaccine, antibodies were measured by a competitive Luminex immunoassay (HPV-4 cLIA). A nine-valent HPV (9vHPV) vaccine targeting the types in the qHPV vaccine (HPV6/11/16/18), as well as 5 of the next most frequent HPV types found in cervical cancers worldwide (HPV31/33/45/52/58) is under development. To support the 9vHPV vaccine program, a nine-multiplexed cLIA (HPV-9 cLIA) was developed. Antibody titers were determined in a competitive format, where type-specific phycoerythrin (PE)-labeled, neutralizing mAbs (mAbs-PE) compete with an individual's serum antibodies for binding to conformationally sensitive, neutralizing epitopes on the VLPs. Neutralizing antibody levels were quantitated against a reference standard - a pool of sera from 6 Rhesus macaques that were immunized with the 9vHPV vaccine. Specificity of the mAbs was assessed by measuring their individual binding capacities to the type-specific and non-type-specific VLPs at alternative concentrations of the mAbs. Antibody assignments to the HPV-9 cLIA reference standard for HPV6/11/16/18 were determined to provide for a measure of consistency in serostatus assignment between the HPV-4 and HPV-9 cLIAs. Antibody assignments to the HPV-9 reference standard for HPV31/33/45/52/58 were obtained by calibration to HPV11 using a direct binding IgG assay. For each HPV VLP type, the cross-reactivity of the mAb-PEs in the HPV-9 cLIA was <1% (i.e., the mAb-PEs result in <1% non-specific binding). The antibody concentrations assigned to the HPV-9 cLIA reference standard for types 6/11/16/18/31/33/45/52/58 were 3,817, 2,889, 23,061, 5,271, 3,942, 2,672, 1,489, 1274, and 2263 mMU/mL, respectively.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Técnicas de Laboratório Clínico/métodos , Papillomaviridae/imunologia , Infecções por Papillomavirus/imunologia , Infecções por Papillomavirus/virologia , Animais , Anticorpos Monoclonais , Antígenos Virais , Reações Cruzadas , Humanos , Imunoensaio/métodos , Imunoglobulina G/sangue , Macaca mulatta , Sensibilidade e Especificidade , Virossomos
9.
BMC Infect Dis ; 14: 120, 2014 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-24588945

RESUMO

BACKGROUND: Several assays are used to measure type-specific serological responses to human papillomavirus (HPV), including the bead-based glutathione S-transferase (GST)-L1 multiplex serology assay and virus-like particle (VLP)-based ELISA. We evaluated the high-throughput GST-L1, which is increasingly used in epidemiologic research, as a measure of cumulative HPV infection and future immune protection among HPV-unvaccinated women. METHODS: We tested enrollment sera from participants in the control arm of the Costa Rica Vaccine Trial (n = 488) for HPV16 and HPV18 using GST-L1, VLP-ELISA, and two assays that measure neutralizing antibodies (cLIA and SEAP-NA). With statistical adjustment for sampling, we compared GST-L1 serostatus to established HPV seropositivity correlates and incident cervical HPV infection using odds ratios. We further compared GST-L1 to VLP-ELISA using pair-wise agreement statistics and by defining alternate assay cutoffs. RESULTS: Odds of HPV16 GST-L1 seropositivity increased with enrollment age (OR = 1.20 per year, 95%CI 1.03-1.40) and lifetime number of sexual partners (OR = 2.06 per partner, 95%CI 1.49-2.83), with similar results for HPV18. GST-L1 seropositivity did not indicate protection from incident infection over 4 years of follow-up (HPV16 adjusted OR = 1.72, 95%CI 0.95-3.13; HPV18 adjusted OR = 0.38, 95%CI 0.12-1.23). Seroprevalence by GST-L1 (HPV16 and HPV18, respectively) was 5.0% and 5.2%, compared to 19.4% and 23.8% by VLP-ELISA, giving positive agreement of 39.2% and 20.8%. Lowering GST-L1 seropositivity cutoffs improved GST-L1/VLP-ELISA positive agreement to 68.6% (HPV16) and 61.5% (HPV18). CONCLUSIONS: Our data support GST-L1 as a marker of cumulative HPV infection, but not immune protection. At lower seropositivity cutoffs, GST-L1 better approximates VLP-ELISA.


Assuntos
Anticorpos Antivirais/sangue , Glutationa Transferase/sangue , Infecções por Papillomavirus/diagnóstico , Adolescente , Adulto , Anticorpos Neutralizantes/sangue , Costa Rica , DNA Viral/análise , Ensaio de Imunoadsorção Enzimática , Estudos Epidemiológicos , Feminino , Papillomavirus Humano 16 , Papillomavirus Humano 18 , Humanos , Razão de Chances , Infecções por Papillomavirus/sangue , Vacinas contra Papillomavirus/uso terapêutico , Estudos Soroepidemiológicos , Adulto Jovem
10.
Front Oncol ; 3: 328, 2014 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-24455487

RESUMO

BACKGROUND: Different assays, including the competitive Luminex immunoassay (cLIA), secreted alkaline phosphatase neutralization assay (SEAP-NA), and virus-like particle-based ELISA, are commonly used to measure antibody responses after human papillomavirus (HPV) vaccination. Direct assay comparisons aid interpretation of immunogenicity data evaluated by different assays. METHODS: We compared cLIA to SEAP-NA and ELISA among 51 HPV16/18-vaccinated women enrolled in the Costa Rica Vaccine Trial. We tested replicate serum samples collected at months 0, 1, and 12 by HPV16/18 cLIA, SEAP-NA, and ELISA. For a subset (N = 10), we further tested month 6, 24 and 36 samples. We calculated seroprevalence estimates and Spearman rank correlation coefficients comparing cLIA to SEAP-NA and ELISA. RESULTS: After one vaccine dose, seroprevalence by SEAP-NA and ELISA was 100% (both HPV16 and HPV18), and by cLIA was 96% (95% CI 87-100%) for HPV16 and 71% (95% CI 56-83%) for HPV18. Seroprevalence was 100% by all assays after three doses. Correlation between assays was high after one vaccine dose [cLIA/SEAP-NA ρ = 0.91 (HPV16) and ρ = 0.86 (HPV18); cLIA/ELISA ρ = 0.84 (HPV16) and ρ = 0.74 (HPV18); all p < 0.001] and remained high through month 36. Ratios of mean antibody levels to seropositivity cutoffs at month 36 were lower for cLIA than for SEAP-NA or ELISA, particularly for HPV18 (HPV18 ratio for cLIA 1.9, SEAP-NA 3.5, ELISA 3.4). CONCLUSION: Though correlation between cLIA and SEAP-NA/ELISA is high and stable after vaccination, the assays differ in scale and sensitivity, with notable differences after one vaccine dose and for HPV18. Our results demonstrate that comparisons of antibody responses to HPV vaccination measured by different assays are approximate, and must consider biological and technical differences between assays.

11.
PLoS One ; 8(1): e53067, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23301022

RESUMO

BACKGROUND: Several serological assays have been developed to detect antibodies elicited against infections with oncogenic human papillomavirus (HPV) type 16. The association between antibody levels measured by various assays and subsequent HPV infection risk may differ. We compared HPV16-specific antibody levels previously measured by a virus-like particle (VLP)-based direct enzyme-linked immunoassay (ELISA) with levels measured by additional assays and evaluated the protection against HPV16 infection conferred at different levels of the assays. METHODOLOGY/PRINCIPAL FINDINGS: Replicate enrollment serum aliquots from 388 unvaccinated women in the control arm of the Costa Rica HPV vaccine trial were measured for HPV16 seropositivity using three serological assays: a VLP-based direct ELISA; a VLP-based competitive Luminex immunoassay (cLIA); and a secreted alkaline phosphatase protein neutralization assay (SEAP-NA). We assessed the association of assay seropositivity and risk of subsequent HPV16 infection over four years of follow-up by calculating sampling-adjusted odds ratios (OR) and HPV16 seropositivity based on standard cutoff from the cLIA was significantly associated with protection from subsequent HPV16 infection (OR = 0.48, CI = 0.27-0.86, compared with seronegatives). Compared with seronegatives, the highest seropositive tertile antibody levels from the direct ELISA (OR = 0.53, CI = 0.28-0.90) as well as the SEAP-NA (OR = 0.20, CI = 0.06, 0.64) were also significantly associated with protection from HPV16 infection. CONCLUSIONS/SIGNIFICANCE: Enrollment HPV16 seropositivity by any of the three serological assays evaluated was associated with protection from subsequent infection, although cutoffs for immune protection were different. We defined the assays and seropositivity levels after natural infection that better measure and translate to protective immunity.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Infecções por Papillomavirus/sangue , Testes Sorológicos/métodos , Anticorpos Antivirais/sangue , DNA Viral/sangue , Feminino , Papillomavirus Humano 16 , Humanos , Imunoensaio/métodos , Razão de Chances , Infecções por Papillomavirus/imunologia , Kit de Reagentes para Diagnóstico , Risco
12.
Cancer Epidemiol Biomarkers Prev ; 21(9): 1547-54, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22752082

RESUMO

BACKGROUND: Two HPV serological assays, the competitive Luminex immunoassay (cLIA), and an enzyme-linked immunoassay (ELISA) against HPV16 have been used to define HPV-naïve subcohorts within large HPV vaccination trials. Some of the variation in estimated vaccine efficacies may be due to the differences in these assays used to define the HPV-naïve subgroups. To guide the interpretation of published results, we compared these assays. METHODS: Replicate enrollment sera from a stratified sample of 388 unvaccinated women from the control arm of the Costa Rica HPV 16/18 Vaccine Trial were measured for antibodies against HPV16 using cLIA and ELISA. Agreement between the assays was estimated using standard and alternative assay cutoffs. RESULTS: Using laboratory-determined seropositivity cutoffs, sampling-adjusted HPV16 seropositivity was 24.8% by ELISA and 7.2% by cLIA. Comparing cLIA and ELISA antibody levels based on the standard cutoffs, overall agreement was 53% (positive-agreement = 49%). The poor agreement was mainly driven by the higher sensitivity of the ELISA than cLIA, resulting in 30% of the ELISA-positive sample that were cLIA-negative (none of the ELISA-negatives were cLIA-positive). Increasing ELISA cutoff to 54 ELISA units (EU)/mL (the level which maximized agreement with cLIA; ELISA standard cutoff is 8 EU/mL) resulted in higher agreement (overall agreement = 91%; positive agreement = 78%). CONCLUSIONS: ELISA and cLIA are different from each other based on the laboratory-determined cutoff. Increasing ELISA cutoff increased agreement with cLIA, which could facilitate comparisons among studies that use different assays. IMPACT: Keeping cLIA at the laboratory-determined cutoff but altering ELISA cutoff for seropositivity might facilitate vaccine efficacy comparisons in the naïve cohorts defined by cLIA.


Assuntos
Anticorpos Antivirais/sangue , Papillomavirus Humano 16/imunologia , Vacinas contra Papillomavirus/imunologia , Vacinação , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Imunoensaio
13.
Clin Vaccine Immunol ; 19(6): 881-5, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22518014

RESUMO

The exploratory immunogenicity objective of this analysis was to characterize the titer of vaccine human papillomavirus (HPV)-type immunoglobulins in both peripartum maternal blood and the cord blood of infants born to women who received blinded therapy. Data were derived from a randomized, placebo-controlled, double-blind safety, immunogenicity, and efficacy study (protocol 019; NCT00090220). This study enrolled 3,819 women between the ages of 24 and 45 years from 38 international study sites between 18 June 2004 and 30 April 2005. Data in the current analysis are from subjects enrolled in Philippines and Thailand. For each of HPV types 6, 11, 16, and 18, maternal anti-HPV was found in cord blood samples. Furthermore, HPV titers in cord blood samples were highly positively correlated with maternal HPV titers. Additionally, there were instances when anti-HPV antibodies were no longer detectable in maternal serum samples and yet were detected in matched cord blood samples. These results demonstrate that quadrivalent HPV (qHPV) vaccine-induced antibodies cross the placenta and could potentially provide some benefit against vaccine-type HPV infection and related diseases such as recurrent respiratory papillomatosis.


Assuntos
Anticorpos Antivirais/sangue , Imunidade Materno-Adquirida , Vacinas contra Papillomavirus/administração & dosagem , Vacinas contra Papillomavirus/imunologia , Adulto , Feminino , Sangue Fetal/imunologia , Vacina Quadrivalente Recombinante contra HPV tipos 6, 11, 16, 18 , Humanos , Imunoglobulina G/sangue , Lactente , Recém-Nascido , Pessoa de Meia-Idade , Filipinas , Gravidez , Tailândia , Vacinas Virossomais/administração & dosagem , Vacinas Virossomais/imunologia
14.
Clin Vaccine Immunol ; 17(5): 818-27, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20237197

RESUMO

A multiplexed human papillomavirus (HPV) immunoassay has been developed for the detection of human IgG antibodies to HPV type 6, 11, 16, 18, 31, 33, 45, 52, and 58 virus-like particle (VLP) types in serum following natural infection or immunization with VLP-based vaccines. The VLP antigens were covalently conjugated to carboxyl Luminex microspheres (MS) using a carbodiimide chemistry. Antibody (Ab) titers were determined in a direct binding format, in which an IgG1- to -4-specific, phycoerythrin (PE)-labeled monoclonal antibody (MAb) (HP6043) binds to human serum IgG antibodies. Pooled serum samples from rhesus macaques immunized with a 9-valent VLP-based vaccine served as the reference standard. The overall specificity of the assay was >99%, and the linearity (parallelism) of the assay was <7% per 10-fold dilution. Total assay precision was <19% across 3 different VLP-microsphere lots, 2 secondary antibody lots, and 2 different operators over a period of 3 weeks. Three different methods were used to evaluate serostatus cutoffs (SCO): (i) a clinical sensitivity/specificity analysis based on "likely negative" and "likely positive" samples from nonvaccinees, (ii) stringent upper tolerance limits on samples from "likely negatives," and (iii) stringent upper tolerance limits from the same "likely negative" sample set after VLP adsorption. Depending on the method to set the serostatus cutoff, the percentage of seropositive samples at the month 48 time point following vaccination with the HPV 6/11/16/18 quadrivalent vaccine ranged from 70% to 100%. This assay has proven useful for measuring the levels of serum antibody to the nine HPV VLPs following natural infection or administration of VLP-based vaccines.


Assuntos
Anticorpos Antivirais/sangue , Papillomaviridae/imunologia , Infecções por Papillomavirus/diagnóstico , Infecções por Papillomavirus/imunologia , Vacinas contra Papillomavirus/imunologia , Virologia/métodos , Animais , Antígenos Virais , Feminino , Humanos , Imunoensaio/métodos , Imunoglobulina G/sangue , Macaca mulatta , Masculino , Papillomaviridae/classificação , Sensibilidade e Especificidade , Virossomos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA