Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 82: 291-298, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29649657

RESUMO

STUDY: Implantation of a Left Ventricular Assist Device (LVAD) may produce both excessive local tissue stress and resulting strain-induced tissue rupture that are potential iatrogenic factors influencing the success of the surgical attachment of the LVAD into the myocardium. By using a computational simulation compared to mechanical tests, we sought to investigate the characteristics of stress-induced suture material on porcine myocardium. METHODS: Tensile strength experiments (n = 8) were performed on bulk left myocardium to establish a hyperelastic reduced polynomial constitutive law. Simultaneously, suture strength tests on left myocardium (n = 6) were performed with a standard tensile test setup. Experiments were made on bulk ventricular wall with a single U-suture (polypropylene 3-0) and a PTFE pledget. Then, a Finite Element simulation of a LVAD suture case was performed. Strength versus displacement behavior was compared between mechanical and numerical experiments. Local stress fields in the model were thus analyzed. RESULTS: A strong correlation between the experimental and the numerical responses was observed, validating the relevance of the numerical model. A secure damage limit of 100 kPa on heart tissue was defined from mechanical suture testing and used to describe numerical results. The impact of suture on heart tissue could be accurately determined through new parameters of numerical data (stress diffusion, triaxiality stress). Finally, an ideal spacing between sutures of 2 mm was proposed. CONCLUSION: Our computational model showed a reliable ability to provide and predict various local tissue stresses created by suture penetration into the myocardium. In addition, this model contributed to providing valuable information useful to design less traumatic sutures for LVAD implantation. Therefore, our computational model is a promising tool to predict and optimize LVAD myocardial suture.


Assuntos
Simulação por Computador , Coração Auxiliar , Miocárdio/citologia , Estresse Mecânico , Suturas/efeitos adversos , Animais , Análise de Elementos Finitos , Suínos
2.
J Cardiovasc Surg (Torino) ; 56(6): 929-37, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24647320

RESUMO

AIM: Despite controversies, off-pump coronary artery bypass (OPCAB) surgery has become a routine procedure. Obvious advantages have been demonstrated in high-risk patients. However, OPCAB surgery has limitations in specific high-risk situations with hazards of operative deleterious events. We describe an innovative procedure of self-myocardial retroperfusion (SMR) with an aortic-coronary sinus shunt (ACSS). We prospectively evaluated the protective effects and benefits of SMR in high-risk coronary patients with impaired LVEF. METHODS: Eighteen consecutive high-risk (ES>10) coronary patients (mean age: 65.94 years; range: 34-85; mean ES: 26.97%) with LVEF≤35% who were not eligible for IABP were assigned for OPCAB surgery. Following sternotomy, the cardiac indexes (CI) were measured before, during SMR and after completion of coronary artery bypasses. Operative events with and without SMR were accurately collected, and postoperative cardiac Troponin T release was measured. RESULTS: OPCAB procedures were performed in all patients. Intraoperative use of SMR significantly increased CI (P=3.1041810.10-8) and reversed deleterious operative events (ECG changes/low cardiac output). Hospital mortality was 0%. Incidence of transient atrial fibrillation was 33.33%. Neither stroke nor renal insufficiency was observed. The mean graft number/patient was 2.05. Mean postoperative cardiac Troponin T value was 0.79 µg/L. Beating heart preservation optimized by SMR contributed to reduce ischemia-reperfusion injury, as validated by an immediate increase of CI after completion of coronary bypasses (P=3.35009.10-9). CONCLUSION: The concept of SMR with an ACSS during OPCAB procedures definitely improved CI and reversed ischemic features in high-risk patients and should be considered as an operative temporary myocardial assistance.


Assuntos
Débito Cardíaco , Ponte de Artéria Coronária sem Circulação Extracorpórea , Doença da Artéria Coronariana/cirurgia , Circulação Coronária , Seio Coronário/fisiopatologia , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Perfusão/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismo por Reperfusão Miocárdica/diagnóstico , Traumatismo por Reperfusão Miocárdica/etiologia , Traumatismo por Reperfusão Miocárdica/fisiopatologia , Perfusão/efeitos adversos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Troponina T/sangue , Função Ventricular Esquerda
3.
J Cardiovasc Surg (Torino) ; 55(2): 295-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24670834

RESUMO

Catheter ablation is a well-established therapeutic option for management of recurrent ventricular tachycardia in patients with ischemic/non-ischemic heart disease and procedural complications include a mortality rate of up to 3% and a risk of major complications up to 10%. Cardiac perforation following a catheter ablation is rare but serious complication and occurs in 1% of ventricular ablation procedures. The appropriate surgical repair may be challenging and need cardiopulmonary bypass support according to the location of the lesion and the hemodynamic status of the patient. We report the case of a free wall right ventricular perforation of the interventricular groove with cardiac tamponade following catheter ablation for recurrent ventricular tachycardia. Due to the proximity of the left anterior descending artery and the extreme fragility of tissues, the patient was treated successfully by a sutureless patch technique using a fibrin tissue-adhesive collagen fleece (TachoSil®). This technique is a safe and effective surgical option to repair a ventricular perforation especially when the ventricular tissues are fragile. It is simple and enable to realize surgical repair also if the localization of tear is difficult to access and without the need for cardiopulmonary bypass support if hemodynamic conditions are stable.


Assuntos
Ablação por Cateter/efeitos adversos , Endocárdio/cirurgia , Fibrinogênio/uso terapêutico , Traumatismos Cardíacos/cirurgia , Ventrículos do Coração/cirurgia , Técnicas Hemostáticas/instrumentação , Trombina/uso terapêutico , Idoso de 80 Anos ou mais , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/cirurgia , Combinação de Medicamentos , Traumatismos Cardíacos/diagnóstico , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/fisiopatologia , Ventrículos do Coração/lesões , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Humanos , Masculino , Derrame Pericárdico/etiologia , Derrame Pericárdico/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA