Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 11: 172, 2010 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-20684752

RESUMO

BACKGROUND: In the face of costly fixation hardware with varying performance for treatment of distal humeral fractures, a novel technique (U-Frame) is proposed using conventional implants in a 180 degrees plate arrangement. In this in-vitro study the biomechanical stability of this method was compared with the established technique which utilizes angular stable locking compression plates (LCP) in a 90 degrees configuration. METHODS: An unstable distal 3-part fracture (AO 13-C2.3) was created in eight pairs of human cadaveric humeri. All bone pairs were operated with either the "Frame" technique, where two parallel plates are distally interconnected, or with the LCP technique. The specimens were cyclically loaded in simulated flexion and extension of the arm until failure of the construct occurred. Motion of all fragments was tracked by means of optical motion capturing. Construct stiffness and cycles to failure were identified for all specimens. RESULTS: Compared to the LCP constructs, the "Frame" technique revealed significant higher construct stiffness in extension of the arm (P = 0.01). The stiffness in flexion was not significantly different (P = 0.16). Number of cycles to failure was found significantly larger for the "Frame" technique (P = 0.01). CONCLUSIONS: In an in-vitro context the proposed method offers enhanced biomechanical stability and at the same time significantly reduces implant costs.


Assuntos
Fixação de Fratura/instrumentação , Fraturas do Úmero/cirurgia , Úmero/cirurgia , Fixadores Internos/normas , Desenho de Prótese/métodos , Implantação de Prótese/métodos , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Placas Ósseas/normas , Placas Ósseas/tendências , Cadáver , Análise de Falha de Equipamento/métodos , Feminino , Fixação de Fratura/métodos , Humanos , Fraturas do Úmero/fisiopatologia , Úmero/fisiopatologia , Fixadores Internos/tendências , Instabilidade Articular/fisiopatologia , Instabilidade Articular/prevenção & controle , Instabilidade Articular/cirurgia , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/prevenção & controle , Amplitude de Movimento Articular/fisiologia , Estresse Mecânico , Suporte de Carga/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA