Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 63(5): 1376-82, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20432308

RESUMO

Nine asymptomatic subjects and six patients underwent T(1)rho MRI to determine whether Outerbridge grade 1 or 2 cartilage degeneration observed during arthroscopy could be detected noninvasively. MRI was performed 2-3 months postarthroscopy, using sagittal T(1)-weighted and axial and coronal T(1)rho MRI, from which spatial T(1)rho relaxation maps were calculated from segmented T(1)-weighted images. Median T(1)rho relaxation times of patients with arthroscopically documented cartilage degeneration and asymptomatic subjects were significantly different (P < 0.001), and median T(1)rho exceeded asymptomatic articular cartilage median T(1)rho by 2.5 to 9.2 ms. In eight observations of mild cartilage degeneration at arthroscopy (Outerbridge grades 1 and 2), mean compartment T(1)rho was elevated in five, but in all observations, large foci of increased T(1)rho were observed. It was determined that T(1)rho could detect some, but not all, Outerbridge grade 1 and 2 cartilage degeneration but that a larger patient population is needed to determine the sensitivity to these changes.


Assuntos
Algoritmos , Artroscopia , Doenças das Cartilagens/patologia , Cartilagem/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Magn Reson Med ; 62(4): 993-1001, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19672947

RESUMO

A spin-locked balanced steady-state free-precession (slSSFP) pulse sequence is described that combines a balanced gradient-echo acquisition with an off-resonance spin-lock pulse for fast MRI. The transient and steady-state magnetization trajectory was solved numerically using the Bloch equations and was shown to be similar to balanced steady-state free-precession (bSSFP) for a range of T(2)/T(1) and flip angles, although the slSSFP steady-state could be maintained with considerably lower radio frequency (RF) power. In both simulations and brain scans performed at 7T, slSSFP was shown to exhibit similar contrast and signal-to-noise ratio (SNR) efficiency to bSSFP, but with significantly lower power.


Assuntos
Algoritmos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Feminino , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Marcadores de Spin , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA