Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
World Neurosurg ; 151: e607-e614, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33940268

RESUMO

BACKGROUND: Expandable cages for interbody fusion allow for in situ expansion optimizing fit while mitigating endplate damage. Studies comparing outcomes after using expandable or static cages have been conflicting. METHODS: This was a meta-analysis A systematic search was performed in accordance with the Preferred Reporting Items for Systemic Reviews and Meta-Analyses (PRISMA) guidelines identifying studies reporting outcomes among patients who underwent minimally invasive lumbar interbody fusion (MIS-LIF). RESULTS: Fourteen articles with 1129 patients met inclusion criteria. Compared with MIS-LIFs performed with static cages, those with expandable cages had a significantly lower incidence of graft subsidence (expandable: incidence 0.03, I2 22.50%; static: incidence 0.27, I2 51.03%, P interaction <0.001), length of hospital stay (expandable: mean difference [MD] 3.55 days, I2 97%; static: MD 7.1 days, I2 97%, P interaction <0.01), and a greater increase in disc height (expandable: MD -4.41 mm, I2 99.56%; static: MD -0.79 mm, I2 99.17%, P interaction = 0.02). There was no statistically significant difference among Oswestry Disability Index (expandable: MD -22.75, I2 98.17%; static: MD -17.11, I2 95.26%, P interaction = 0.15), fusion rate (expandable: incidence 0.94, I2 0%; static incidence 0.92, I2 0%, P interaction = 0.44), overall change in lumbar lordosis (expandable: MD 3.48 degrees, I2 59.29%; static: MD 3.67 degrees, I2 0.00%, P interaction 0.88), blood loss (expandable: MD 228.9 mL, I2 100%; static: MD 261.1 mL, I2 94%, P interaction = 0.69) and operative time (expandable: MD 184 minutes, I2 95.32%; static: MD 150.4 minutes, I2 91%, P interaction = 0.56). CONCLUSIONS: Expandable interbody cages in MIS-LIF were associated with a decrease in subsidence rate, operative time and greater in increase in disc height.


Assuntos
Fixadores Internos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Fusão Vertebral/instrumentação , Humanos , Vértebras Lombares
2.
Interv Neuroradiol ; 27(2): 200-206, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32931373

RESUMO

BACKGROUND: The Penumbra SMART coil is a novel device that becomes progressively softer from its distal to proximal end to maximize coil packing and prevent microcatheter prolapse or coil migration. Here, we report a large series of patients detailing the long-term experience of a single institution using the SMART coil among patients with intracranial aneurysms (IAs). METHODS: Prospective data of 105 consecutive patients with 106 IAs treated using SMART coils was collected between March 2015 and July 2018. Clinical and angiographic data were analyzed. RESULTS: Forty-nine patients (46.7%) presented with subarachnoid hemorrhage and 16 (14.2%) had recurrent aneurysms. Two patients had minor intraprocedural ruptures and remained neurologically stable. One patient had a thromboembolic complication with progressive neurologic decline. There was only one case microcatheter prolapse related to placement of a stent before coiling. An initial post-treatment modified Raymond-Roy Occlusion Classification (mRROC) I or II closure was achieved in 56 (52.8%) aneurysms. The average time to last follow-up was 8.4 months at which 70 (81.4%) aneurysms had mRROC I or II occlusion and a major recurrence was seen in 5 (5.8%) patients. Thirteen (12.3%) aneurysms required re-treatment of which one aneurysm was clipped. CONCLUSIONS: The Penumbra SMART coil is safe and effective for the endovascular treatment of appropriately selected IAs. Additional studies at multiple centers comparing safety and efficacy profile over long-term periods to other mainstream coils are necessary.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Hemorragia Subaracnóidea , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Stents , Resultado do Tratamento , Adulto Jovem
3.
Neurosurg Clin N Am ; 31(4): 627-639, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32921357

RESUMO

Brain metastases lead to substantial morbidity and mortality among patients with advanced malignancies. Although treatment options have traditionally included largely palliative measures, studies of brain metastasis response to immunotherapy are promising. Immune checkpoint inhibitors have shown efficacy in studies of patients with melanoma, renal cell carcinoma, and lung cancer brain metastases. Patients with brain metastases are more frequently included in clinical trials, ushering in a new era in immunotherapy and management for patients with brain metastases. Gaining an understanding of the molecular determination for response to immunotherapies remains a major challenge and is an active area of future research.


Assuntos
Neoplasias Encefálicas/terapia , Neoplasias do Sistema Nervoso Central/terapia , Imunoterapia , Animais , Neoplasias Encefálicas/imunologia , Neoplasias Encefálicas/fisiopatologia , Neoplasias do Sistema Nervoso Central/imunologia , Neoplasias do Sistema Nervoso Central/fisiopatologia , Terapia Combinada/métodos , Humanos , Resultado do Tratamento , Microambiente Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA