J Radiol Prot ; 44(3)2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39168137

RESUMO

Radiopharmacy staff members are subject to extremity radiation doses, particularly to the fingertips. Dosemeters, such as, thermoluminescent detectors (TLDs) are currently used for monitoring fingertip doses. This study aimed to use real-time dosemeters to monitor radiopharmacy extremity doses to identify specific procedural steps associated with higher fingertip doses and, subsequently, reduce dose through promotion of optimised radiation protection practises. Five radiopharmacy operators were monitored using an ED3 active extremity dosemeter with a detector attached to each tip of the index fingers. Dose rate and accumulated dose data were matched to the handled radioactivity data, of99mTc-labelled radiopharmaceuticals only, with the dose per activity (µSv MBq-1) calculated for each step. Once baseline dose data was established, an educational session identified technique adjustments toward improved radiation protection. A subsequent monitored session was undertaken with the dose data compared to quantify changes in operator doses. Radiopharmacy steps which significantly contributed to extremity doses were identified. The average accumulated dose per activity across all procedural steps for the99mTc-labelled radiopharmaceuticals for all operators before the educational session was 0.042 ± 0.045µSv MBq-1and 0.042 ± 0.041µSv MBq-1(n= 89) for non-dominant and dominant index fingertips, respectively, and 0.030 ± 0.044µSv MBq-1and 0.031 ± 0.032µSv MBq-1(n= 97), respectively, afterwards. Overall, there was an average 40.7% reduction in the total extremity dose received after the educational session. Real-time electronic extremity dosemeters for monitoring radiopharmacy extremity dose presented as a useful tool for incorporation into radiation protection education and training, towards optimised radiopharmacy technique.


Assuntos
Exposição Ocupacional , Doses de Radiação , Dosímetros de Radiação , Monitoramento de Radiação , Proteção Radiológica , Compostos Radiofarmacêuticos , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Humanos , Monitoramento de Radiação/métodos , Monitoramento de Radiação/instrumentação , Compostos Radiofarmacêuticos/análise , Dedos/efeitos da radiação , Dosimetria Termoluminescente
3.
Skin Health Dis ; 2(3): e97, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35941939

RESUMO

Targeted ultraviolet (UV) phototherapy has been used in the management of a wide variety of dermatological clinical conditions including moderate to severe psoriasis unresponsive to topical therapies, vitiligo, severe atopic dermatitis and lymphoproliferative disorders. To date there are no uniform, standardised guidelines for the selection and decontamination process for UV personal protective equipment (PPE) and facial shields used in phototherapy. In the current climate, Coronavirus 2019 (COVID-19) pandemic, standards regarding all decontamination and disinfection processes are under significant scrutiny. In terms of the UV-PPE and facial shields used in phototherapy, careful disinfection procedures need to be implemented to ensure that the decontamination practice is effective enough to neutralise the virulent virus whilst maintaining maximal protection to the user from UV-rays and safeguard the equipment from damage during the cleaning process. The aim of this report is to provide an evidence based review of the current and international practice standards guiding the selection, use and decontamination processes of UV facial shields in phototherapy. The complications and concerns that the COVID-19 pandemic has had on this practice is highlighted. As such, we performed a comprehensive evaluation of the literature to provide recommendations as to the most effective, time efficient and safest practices for disinfection and decontamination of UV facial shields used in phototherapy during these unprecedented times.

4.
J Opt Soc Am A Opt Image Sci Vis ; 39(1): 127-135, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35200982

RESUMO

Daylight photodynamic therapy (D-PDT) is an effective and almost painless treatment for many skin conditions, where successful treatment relies on daylight activation of a topical photosensitizer. Optimization of D-PDT requires accurate assessment of light dose received. There is a requirement for a small-area sensor that can be placed adjacent to the treatment site to facilitate accurate dose quantification. Here, a novel, to the best of our knowledge, configuration for a D-PDT dose sensor, consisting of a holographic absorption grating fabricated in a photosensitive film, is presented. Theoretical modeling of the sensor's response (i.e., change in grating diffraction efficiency due to change in grating absorption modulation, α1, on exposure to daylight) was conducted using Kogelnik's coupled-wave theory. The influence of the different grating parameters (initial film absorption, thickness, spatial frequency, and reconstruction wavelength) on the sensor response was examined and revealed that the initial absorption and grating thickness values have a large impact on both the magnitude and rate of the D-PDT sensor response. The optimum design for an absorption grating-based D-PDT sensor is described.


Assuntos
Fotoquimioterapia , Fármacos Fotossensibilizantes/uso terapêutico
5.
Phys Med Biol ; 63(3): 035013, 2018 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-29192611

RESUMO

Daylight photodynamic therapy (dl-PDT) is as effective as conventional PDT (c-PDT) for treating actinic keratoses but has the advantage of reducing patient discomfort significantly. Topical dl-PDT and white light-PDT (wl-PDT) differ from c-PDT by way of light sources and methodology. We measured the variables associated with light dose delivery to skin surface and influence of geometry using a radiometer, a spectral radiometer and an illuminance meter. The associated errors of the measurement methods were assessed. The spectral and spatial distribution of the radiant energy from the LED white light source was evaluated in order to define the maximum treatment area, setup and treatment protocol for wl-PDT. We compared the data with two red LED light sources we use for c-PDT. The calculated effective light dose is the product of the normalised absorption spectrum of the photosensitizer, protoporphyrin IX (PpIX), the irradiance spectrum and the treatment time. The effective light dose from daylight ranged from 3 ± 0.4 to 44 ± 6 J cm-2due to varying weather conditions. The effective light dose for wl-PDT was reproducible for treatments but it varied across the treatment area between 4 ± 0.1 J cm-2 at the edge and 9 ± 0.1 J cm-2 centrally. The effective light dose for the red waveband (615-645 nm) was 0.42 ± 0.05 J cm-2 on a clear day, 0.05 ± 0.01 J cm-2 on an overcast day and 0.9 ± 0.01 J cm-2 using the white light. This compares with 0.95 ± 0.01 and 0.84 ± 0.01 J cm-2 for c-PDT devices. Estimated errors associated with indirect determination of daylight effective light dose were very significant, particularly for effective light doses less than 5 J cm-2 (up to 83% for irradiance calculations). The primary source of error is in establishment of the relationship between irradiance or illuminance and effective dose. Use of the O'Mahoney model is recommended using a calibrated logging illuminance meter with the detector in the plane of the treatment area.


Assuntos
Ácido Aminolevulínico/administração & dosagem , Ceratose Actínica/tratamento farmacológico , Luz , Iluminação/métodos , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/administração & dosagem , Administração Tópica , Humanos , Ceratose Actínica/metabolismo , Iluminação/instrumentação , Masculino , Protoporfirinas/metabolismo , Doses de Radiação , Radiometria