Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
J Thorac Imaging ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38635472

RESUMO

PURPOSE: Small left atrial (LA) volume was recently reported to be one of the best predictors of acute pulmonary embolism (PE)-related adverse events (AE). There is currently no data available regarding the impact that body surface area (BSA)-indexing of atrial measurements has on the association with PE-related adverse events. Our aim is to assess the impact of indexing atrial measurements to BSA on the association between computed tomography (CT) atrial measurements and AE. MATERIALS AND METHODS: Retrospective study (IRB: 2015P000425). A database of hospitalized patients with acute PE diagnosed on CT pulmonary angiography (CTPA) between May 2007 and December 2014 was reviewed. Right and left atrial volume, largest axial area, and axial diameters were measured. Patients undergo both echocardiographies (from which the BSA was extracted) and CTPAs within 48 hours of the procedure. The patient's body weight was measured during each admission. LA measurements were correlated to AE (defined as the need for advanced therapy or PE-related mortality at 30 days) before and after indexing for BSA. The area under the ROC curve was calculated to determine the predictive value of the atrial measurements in predicting AE. RESULTS: The study included 490 acute PE patients; 62 (12.7%) had AE. There was a significant association of reduced BSA-indexed and non-indexed LA volume (both <0.001), area (<0.001 and 0.001, respectively), and short-axis diameters (both <0.001), and their respective RA/LA ratios (all <0.001) with AE. The AUC values were similar for BSA-indexed and non-indexed LA volume, diameters, and area with LA volume measurements being the best predictor of adverse outcomes (BSA-indexed AUC=0.68 and non-indexed AUC=0.66), followed by non-indexed LA short-axis diameter (indexed AUC=0.65, non-indexed AUC=0.64), and LA area (indexed AUC=0.64, non-indexed AUC=0.63). CONCLUSION: Adjusting for BSA does not substantially affect the predictive ability of atrial measurements on 30-day PE-related adverse events, and therefore, this adjustment is not necessary in clinical practice. While LA volume is the better predictor of AE, LA short-axis diameter has a similar predictive value and is more practical to perform clinically.

2.
BMJ Open ; 14(1): e081123, 2024 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-38296278

RESUMO

INTRODUCTION: Diabetic retinopathy is a leading cause of vision impairment globally. Vision loss from diabetic retinopathy can generally be prevented by early detection and timely treatment. The WHO included a measure of service access for diabetic retinopathy as a core indicator in the Eye Care Indicator Menu launched in 2022: retina screening coverage for people with diabetes. The aim of this review is to provide a comprehensive global and regional summary of the available information on retina screening coverage for people with diabetes. METHODS AND ANALYSIS: A search will be conducted in five databases without language restrictions for studies from any country reporting retina screening coverage for adults with any type of diabetes at the national or subnational level using data collected since 1 January 2000 until the search date. We will also seek reports and coverage statistics from government websites of all WHO member states. Two investigators will independently screen studies, extract relevant data and assess risk of bias of included studies. The results of the review will be reported using the Preferred Reporting Items for Systematic Review and Meta-Analysis guideline. We will summarise the range of coverage definitions reported across included studies and present the median retina screening coverage in WHO regions and by World Bank country income level. Depending on the availability of data, we will conduct meta-analysis to assess disparities in retina screening coverage for people with diabetes by factors in the PROGRESS framework (Place of residence, Race/ethnicity/culture/language, Occupation, Gender/sex, Religion, Education, Socioeconomic status and Social capital). ETHICS AND DISSEMINATION: This review will only include published data thus no ethical approval will be sought. The findings of this review will be published in a peer-reviewed journal and presented at relevant conferences. PROTOCOL REGISTRATION NUMBER: OSF registration 17/10/2023: https://osf.io/k5p69.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Humanos , Retinopatia Diabética/diagnóstico , Revisões Sistemáticas como Assunto , Metanálise como Assunto , Retina , Transtornos da Visão , Projetos de Pesquisa , Literatura de Revisão como Assunto
3.
Eye (Lond) ; 2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37853109

RESUMO

BACKGROUND: Travel time can be used to assess health services accessibility by reflecting the proximity of services to the people they serve. We aimed to demonstrate an indicator of physical access to cataract surgery and identify subnational locations where people were more at risk of not accessing cataract surgery. METHODS: We used an open-access inventory of public health facilities plus key informants in Kenya, Malawi and Rwanda to compile a geocoded inventory of cataract facilities. For each country, gridded estimates of the population aged ≥ 50 years and a travel-time friction surface were combined and a least-cost-path algorithm applied to estimate the shortest travel time between each grid and the nearest cataract facility. We categorised continuous travel time by 1-, 2- and 3 h thresholds and calculated the proportion of the population in each category. RESULTS: At the national level, the proportion of the population aged ≥ 50 years within 2 h travel time to permanent cataract surgical services was 97.2% in Rwanda (n = 10 facilities), 93.5% in Kenya (n = 74 facilities) and 92.0% in Malawi (n = 6 facilities); this reduced to 77.5%, 84.1% and 52.4% within 1 h, respectively. The least densely populated subnational regions had the poorest access to cataract facilities in Malawi (0.0%) and Kenya (1.9%). CONCLUSION: We demonstrated an indicator of access that reflects the distribution of the population at risk of age-related cataract and identifies regions that could benefit from more accessible services. This indicator provides additional demand-side context for eye health planning and supports WHO's goal of advancing integrated people-centred eye care.

4.
BMJ Open ; 13(3): e069325, 2023 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-36882236

RESUMO

OBJECTIVE: Monitoring health outcomes disaggregated by socioeconomic position (SEP) is crucial to ensure no one is left behind in efforts to achieve universal health coverage. In eye health planning, rapid population surveys are most commonly implemented; these need an SEP measure that is feasible to collect within the constraints of a streamlined examination protocol. We aimed to assess whether each of four SEP measures identified inequality-an underserved group or socioeconomic gradient-in key eye health outcomes. DESIGN: Population-based cross-sectional survey. PARTICIPANTS: A subset of 4020 adults 50 years and older from a nationally representative sample of 9188 adults aged 35 years and older in The Gambia. OUTCOME MEASURES: Blindness (presenting visual acuity (PVA) <3/60), any vision impairment (VI) (PVA <6/12), cataract surgical coverage (CSC) and effective cataract surgical coverage (eCSC) at two operable cataract thresholds (<6/12 and <6/60) analysed by one objective asset-based measure (EquityTool) and three subjective measures of relative SEP (a self-reported economic ladder question and self-reported household food adequacy and income sufficiency). RESULTS: Subjective household food adequacy and income sufficiency demonstrated a socioeconomic gradient (queuing pattern) in point estimates of any VI and CSC and eCSC at both operable cataract thresholds. Any VI, CSC <6/60 and eCSC <6/60 were worse among people who reported inadequate household food compared with those with just adequate food. Any VI and CSC <6/60 were worse among people who reported not enough household income compared with those with just enough income. Neither the subjective economic ladder question nor the objective asset-wealth measure demonstrated any socioeconomic gradient or pattern of inequality in any of the eye health outcomes. CONCLUSION: We recommend pilot-testing self-reported food adequacy and income sufficiency as SEP variables in vision and eye health surveys in other locations, including assessing the acceptability, reliability and repeatability of each question.


Assuntos
Catarata , Adulto , Humanos , Estudos Transversais , Reprodutibilidade dos Testes , Coleta de Dados , Catarata/epidemiologia , Renda
5.
Ann Noninvasive Electrocardiol ; 28(3): e13041, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36691977

RESUMO

BACKGROUND: The spatial ventricular gradient (SVG) is a vectorcardiographic measurement that reflects cardiac loading conditions via electromechanical coupling. OBJECTIVES: We hypothesized that the SVG is correlated with right ventricular (RV) strain and is prognostic of adverse events in patients with acute pulmonary embolism (PE). METHODS: Retrospective, single-center study of patients with acute PE. Electrocardiogram (ECG), imaging, and outcome data were obtained. SVG components were regressed on tricuspid annular plane systolic excursion (TAPSE), qualitative RV dysfunction, and RV/left ventricular (LV) ratio. Odds of adverse outcomes (30-day mortality, vasopressor requirement, or advanced therapy) after PE were regressed on demographics, RV/LV ratios, traditional ECG signs of RV dysfunction, and SVG components using a logit model. RESULTS: ECGs from 317 patients (48% male, age 63.1 ± 16.6 years) with acute PE were analyzed; 36 patients (11.4%) experienced an adverse event. Worse RV hypokinesis, larger RV/LV ratio, and smaller TAPSE were associated with smaller SVG X and Y components, larger SVG Z components, and smaller SVG vector magnitude (p < .001 for all). In multivariable logistic regression, odds of adverse events after PE decreased with increasing SVG magnitude and TAPSE (OR 0.32 and 0.54 per standard deviation increase; p = .03 and p = .004, respectively). Receiver operating characteristic (ROC) analysis showed that, when combined with imaging, replacing traditional ECG criteria with the SVG significantly improved the area under the ROC from 0.70 to 0.77 (p = .01). CONCLUSION: The SVG is correlated with RV dysfunction and adverse outcomes in acute PE and has a better prognostic value than traditional ECG markers.


Assuntos
Eletrocardiografia , Embolia Pulmonar , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Retrospectivos , Embolia Pulmonar/diagnóstico por imagem , Doença Aguda , Prognóstico
6.
Br J Ophthalmol ; 107(6): 876-882, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-34949578

RESUMO

BACKGROUND/AIMS: The 1986 Gambia National Eye Health Survey provided baseline data for a National Eye Health Programme. A second survey in 1996 evaluated changes in population eye health a decade later. We completed a third survey in 2019, to determine the current state of population eye health, considering service developments and demographic change. METHODS: We estimated prevalence and causes of vision impairment (VI) in a nationally representative population-based sample of adults 35 years and older. We used multistage cluster random sampling to sample 10 800 adults 35 and above in 360 clusters of 30. We measured monocular distance visual acuity (uncorrected and with available correction) using Peek Acuity. Participants with either eye uncorrected or presenting (with available correction) acuity <6/12 were retested with pinhole and refraction, and dilated exams were completed on all eyes by ophthalmologists using a direct ophthalmoscope, slit lamp and 90 D lens. RESULTS: We examined 9188 participants (response rate 83%). The 2013 census age-sex adjusted prevalence of blindness (presenting acuity<3/60 in better seeing eye) was 1.2% (95% CI 0.9 to 1.4) and of moderate or severe VI (MSVI,<6/18 to ≥3/60) was 8.9% (95% CI 9.1 to 9.7). Prevalence of all distance VI (<6/12) was 13.4% (12.4-14.4). Compared with 1996, the relative risk of blindness decreased (risk ratio 0.7, 95% CI 0.5 to 1.0) and MSVI increased (risk ratio 1.5, 95% CI 1.2 to 0.17). CONCLUSION: Significant progress has been made to reduce blindness and increase access to eye health across the Gambia, with further work is needed to decrease the risk of MSVI.


Assuntos
Baixa Visão , Pessoas com Deficiência Visual , Adulto , Humanos , Gâmbia/epidemiologia , Baixa Visão/epidemiologia , Baixa Visão/etiologia , Prevalência , Cegueira/epidemiologia , Cegueira/etiologia , Transtornos da Visão
7.
Lancet Glob Health ; 10(12): e1754-e1763, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36240807

RESUMO

BACKGROUND: In 2021, WHO Member States endorsed a global target of a 40-percentage-point increase in effective refractive error coverage (eREC; with a 6/12 visual acuity threshold) by 2030. This study models global and regional estimates of eREC as a baseline for the WHO initiative. METHODS: The Vision Loss Expert Group analysed data from 565 448 participants of 169 population-based eye surveys conducted since 2000 to calculate eREC (met need/[met need + undermet need + unmet need]). A binary logistic regression model was used to estimate eREC by Global Burden of Disease (GBD) Study super region among adults aged 50 years and older. FINDINGS: In 2021, distance eREC was 79·1% (95% CI 72·4-85·0) in the high-income super region; 62·1% (54·7-68·8) in north Africa and Middle East; 49·5% (45·0-54·0) in central Europe, eastern Europe, and central Asia; 40·0% (31·7-48·2) in southeast Asia, east Asia, and Oceania; 34·5% (29·4-40·0) in Latin America and the Caribbean; 9·0% (6·5-12·0) in south Asia; and 5·7% (3·1-9·0) in sub-Saharan Africa. eREC was higher in men and reduced with increasing age. Global distance eREC increased from 2000 to 2021 by 19·0%. Global near vision eREC for 2021 was 20·5% (95% CI 17·8-24·4). INTERPRETATION: Over the past 20 years, distance eREC has increased in each super region yet the WHO target will require substantial improvements in quantity and quality of refractive services in particular for near vision impairment. FUNDING: WHO, Sightsavers, The Fred Hollows Foundation, Fondation Thea, Brien Holden Vision Institute, Lions Clubs International Foundation.


Assuntos
Saúde Global , Erros de Refração , Adulto , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Carga Global da Doença , África Subsaariana , Europa (Continente) , Erros de Refração/epidemiologia , Erros de Refração/terapia
8.
Lancet Glob Health ; 10(12): e1744-e1753, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36240806

RESUMO

BACKGROUND: Cataract is the leading cause of blindness globally. Effective cataract surgical coverage (eCSC) measures the number of people in a population who have been operated on for cataract, and had a good outcome, as a proportion of all people operated on or requiring surgery. Therefore, eCSC describes service access (ie, cataract surgical coverage, [CSC]) adjusted for quality. The 74th World Health Assembly endorsed a global target for eCSC of a 30-percentage point increase by 2030. To enable monitoring of progress towards this target, we analysed Rapid Assessment of Avoidable Blindness (RAAB) survey data to establish baseline estimates of eCSC and CSC. METHODS: In this secondary analysis, we used data from 148 RAAB surveys undertaken in 55 countries (2003-21) to calculate eCSC, CSC, and the relative quality gap (% difference between eCSC and CSC). Eligible studies were any version of the RAAB survey conducted since 2000 with individual participant survey data and census population data for people aged 50 years or older in the sampling area and permission from the study's principal investigator for use of data. We compared median eCSC between WHO regions and World Bank income strata and calculated the pooled risk difference and risk ratio comparing eCSC in men and women. FINDINGS: Country eCSC estimates ranged from 3·8% (95% CI 2·1-5·5) in Guinea Bissau, 2010, to 70·3% (95% CI 65·8-74·9) in Hungary, 2015, and the relative quality gap from 10·8% (CSC: 65·7%, eCSC: 58·6%) in Argentina, 2013, to 73·4% (CSC: 14·3%, eCSC: 3·8%) in Guinea Bissau, 2010. Median eCSC was highest among high-income countries (60·5% [IQR 55·6-65·4]; n=2 surveys; 2011-15) and lowest among low-income countries (14·8%; [IQR 8·3-20·7]; n=14 surveys; 2005-21). eCSC was higher in men than women (148 studies pooled risk difference 3·2% [95% CI 2·3-4·1] and pooled risk ratio of 1·20 [95% CI 1·15-1·25]). INTERPRETATION: eCSC varies widely between countries, increases with greater income level, and is higher in men. In pursuit of 2030 targets, many countries, particularly in lower-resource settings, should emphasise quality improvement before increasing access to surgery. Equity must be embedded in efforts to improve access to surgery, with a focus on underserved groups. FUNDING: Indigo Trust, Peek Vision, and Wellcome Trust.


Assuntos
Extração de Catarata , Catarata , Masculino , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Catarata/epidemiologia , Catarata/complicações , Cegueira/epidemiologia , Saúde Global , Inquéritos Epidemiológicos , Prevalência
9.
Clin Neurol Neurosurg ; 219: 107332, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35738118

RESUMO

INTRODUCTION: Accuracy is crucial in Deep Brain Stimulation (DBS). Electrophysiological and image-based techniques are used to avoid suboptimal positioning. Macrostimulation is the gold standard to delineate the therapeutic window intraoperatively. Despite this, electrode revision rates due to malpositioning are as high as 17%. The goal was to compare motor evoked potentials (MEPs) with the gold standard of Macrostimulation. We assessed accuracy and precision as well as the correlation in predicting motor side effects at the initial mapping 4 weeks postoperatively. METHODS: In this prospective study intraoperative MEPs from 94 contacts in 16 patients undergoing STN DBS under local anesthesia were correlated to the postoperative threshold for stimulation-induced motor side effects and compared to intraoperative Macrostimulation. Analysis of accuracy, precision and correlation (Pearson) was performed. RESULTS: MEPs of the upper extremity had a mean percentage error of 25% (SD 38.8%) and correlated significantly with the motor threshold at postoperative mapping (R=0.235). Macrostimulation was less accurate and precise with a mean percentage error of - 68% (SD 78.8%) but had a higher correlation (R=0.388). MEPs rarely (3%) overestimated the threshold by maximally 1 mA. In contrast, Macrostimulation overestimated the threshold by over 1 mA in 69% leading to a false sense of security. CONCLUSION: MEPs are feasible in an awake setting during Deep Brain Stimulation in the STN for PD patients. MEPs of the upper extremity are more accurate and precise predicting the motor threshold and avoid a false sense of security in comparison to the gold standard of Macrostimulation.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson , Núcleo Subtalâmico , Estimulação Encefálica Profunda/efeitos adversos , Estimulação Encefálica Profunda/métodos , Potencial Evocado Motor/fisiologia , Humanos , Doença de Parkinson/cirurgia , Estudos Prospectivos , Núcleo Subtalâmico/fisiologia , Núcleo Subtalâmico/cirurgia
10.
Artigo em Inglês | MEDLINE | ID: mdl-35409984

RESUMO

This study analyses the use of the self-reported Washington Group (WG) question sets as a first stage screening to identify people with clinical impairments, service and assistive product (AP) referral needs using different cut-off levels in four functional domains (vision, hearing, mobility and cognition). Secondary data analysis was undertaken using population-based survey data from five countries, including one national survey (The Gambia) and four regional/district surveys (Cameroon, Chile, India and Turkey). In total 19,951 participants were sampled (range 538-9188 in individual studies). The WG question sets on functioning were completed for all participants alongside clinical impairment assessments/questionnaires. Using the WG "some/worse difficulty" cut-off identified people with mild/worse impairments with variable sensitivity (44-79%) and specificity (73-92%) in three of the domains. At least 64% and 60% of people with mild/worse impairments who required referral for surgical/medical and rehabilitation/AP services, respectively, self-reported "some/worse difficulty", and much fewer reported "a lot/worse difficulty." For moderate/worse impairment, both screening cut-offs improved identification of service/AP need, but a smaller proportion of people with need were identified. In conclusion, WG questions could be used as a first-stage screening option to identify people with impairment and referral needs, but only with moderate sensitivity and specificity.


Assuntos
Audição , Humanos , Índia , Autorrelato , Inquéritos e Questionários , Washington
11.
J Thorac Imaging ; 37(3): 173-180, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34387226

RESUMO

PURPOSE: To assess the association between computed tomography pulmonary angiography (CTPA) atrial measurements and both 30-day pulmonary embolism (PE)-related adverse events and mortality, and non-PE-related mortality, and to identify the best predictors of these outcomes by comparing atrial measurements and widely used clinical and imaging variables. PATIENTS AND METHODS: Retrospective single-center pilot study. Acute PE patients diagnosed on CTPA who also had a transthoracic echocardiogram, electrocardiogram, and troponin T were included. CTPA left atrial (LA) and right atrial (RA) volume and short-axis diameter were measured and compared between outcome groups, along with right ventricular/left ventricular diameter ratio, interventricular septal bowing, tricuspid annular plane systolic excursion, electrocardiogram, and troponin T. RESULTS: A total of 350 patients. LA volume and diameter were associated with PE-related adverse events (P≤0.01). LA volume was the only atrial measurement associated with PE-related mortality (P=0.03), with no atrial measurements associated with non-PE-related mortality. Troponin was most associated with PE-related adverse events and mortality (both area under the curve [AUC]=0.77). On multivariate analysis, combination models did not greatly improve PE-related adverse events prediction compared with troponin alone. For PE-related mortality, the best models were the combination of troponin, age, and either LA volume (AUC=0.86) or diameter (AUC=0.87). CONCLUSION: Among patients with acute PE, CTPA LA volume is the only imaging parameter associated with PE-related mortality and is the best imaging predictor of this outcome. Reduced CTPA LA volume and diameter, along with increased RA/LA volume and diameter ratios, are significantly associated with 30-day PE-related adverse events, but not with non-PE-related mortality.


Assuntos
Embolia Pulmonar , Troponina T , Doença Aguda , Átrios do Coração/diagnóstico por imagem , Humanos , Projetos Piloto , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Estudos Retrospectivos
12.
Br J Ophthalmol ; 106(7): 893-901, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-33712481

RESUMO

INTRODUCTION: In its recent World Report on Vision, the WHO called for an updated approach to monitor eye health as part of universal health coverage (UHC). This project sought to develop a consensus among eye health experts from all world regions to produce a menu of indicators for countries to monitor eye health within UHC. METHODS: We reviewed the literature to create a long-list of indicators aligned to the conceptual framework for monitoring outlined in WHO's World Report on Vision. We recruited a panel of 72 global eye health experts (40% women) to participate in a two-round, online prioritisation exercise. Two-hundred indicators were presented in Round 1 and participants prioritised each on a 4-point Likert scale. The highest-ranked 95 were presented in Round 2 and were (1) scored against four criteria (feasible, actionable, reliable and internationally comparable) and (2) ranked according to their suitability as a 'core' indicator for collection by all countries. The top 30 indicators ranked by these two parameters were then used as the basis for the steering group to develop a final menu. RESULTS: The menu consists of 22 indicators, including 7 core indicators, that represent important concepts in eye health for 2020 and beyond, and are considered feasible, actionable, reliable and internationally comparable. CONCLUSION: We believe this list can inform the development of new national eye health monitoring frameworks, monitor progress on key challenges to eye health and be considered in broader UHC monitoring indices at national and international levels.


Assuntos
Saúde Global , Cobertura Universal do Seguro de Saúde , Feminino , Humanos , Masculino
13.
Ophthalmic Epidemiol ; 29(4): 353-362, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34622738

RESUMO

PURPOSE: We aimed to review available data on the incidence of herpes simplex virus (HSV) keratitis and other HSV ocular disease and to estimate the global burden of HSV ocular disease. METHODS: We searched Medline and Embase databases to October 2020 for studies reporting on the incidence of HSV ocular disease. Study quality was evaluated using a four-point checklist. Pooled estimates were applied to 2016 population data to estimate global HSV ocular disease burden. Numbers with uniocular vision impairment (any visual acuity <6/12) were estimated by applying published risks to case numbers. RESULTS: Fourteen studies had incidence data; seven met our quality criteria. In 2016, an estimated 1.7 (95% confidence interval, 95% CI 1.0-3.0) million people had HSV keratitis, based on a pooled incidence of 24.0 (95% CI 14.0-41.0; N = 2; I2 = 97.7%) per 100,000 person-years. The majority had epithelial keratitis (pooled incidence 16.1 per 100,000; 95% CI 11.6-22.3; N = 3; I2 = 92.6%). Available studies were few and limited to the USA and Europe. Data were even more limited for HSV uveitis and retinitis, although these conditions may collectively contribute a further >0.1 million cases. Based on global incidence, some 230,000 people may have newly acquired uniocular vision impairment associated with HSV keratitis in 2016. CONCLUSION: Over 1.8 million people may have herpetic eye disease annually. Preventing HSV infection could therefore have an important impact on eye health. Herpetic eye disease burden is likely to have been underestimated, as many settings outside of the USA and Europe have higher HSV-1 prevalence and poorer access to treatment.


Assuntos
Ceratite Herpética , Olho , Humanos , Incidência , Ceratite Herpética/epidemiologia , Prevalência , Simplexvirus
14.
15.
Wellcome Open Res ; 6: 10, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34796273

RESUMO

Two national surveys of vision impairment and blindness were undertaken in The Gambia in 1986 and 1996. These provided data for the inception of The Gambia's National Eye Health Programme (NEHP) within the Ministry of Health and Social Welfare. There have been important developments in the eye health services provided by the NEHP in the last 20 years. At the same time, the population has also undergone major demographic changes that may have led to substantial changes in the burden of eye disease. We conducted a National Eye Health Survey of vision impairment, blindness and its comorbidities in adults in The Gambia in 2019. We examined a nationally representative population-based sample of adults 35 years and above to permit direct comparison with the data available from the previous surveys. Alongside a comprehensive vision and eye examination, the survey provides nationally representative data on important comorbidities in this population: diabetes, hypertension, obesity, hearing impairment, disability and mental health. Secondly, it estimates access to assistive technologies and eye health services. Thirdly, it is powered to allow a five-year follow up cohort study to measure the incidence and progression of eye disease.

16.
Artigo em Inglês | MEDLINE | ID: mdl-34200769

RESUMO

Few estimates are available of the need for assistive devices (ADs) in African settings. This study aimed to estimate population-level need for glasses and hearing aids in The Gambia based on (1) clinical impairment assessment, and (2) self-reported AD awareness, and explore the relationship between the two methods. The Gambia 2019 National Eye Health Survey is a nationally representative population-based sample of 9188 adults aged 35+ years. Participants underwent standardised clinical vision assessments including the need for glasses (distance and near). Approximately 25% of the sample underwent clinical assessment of hearing and hearing aid need. Data were also collected on self-reported awareness, need and access barriers to vision and hearing ADs. Overall, 5.6% of the study population needed distance glasses (95% CI 5.0-6.3), 45.9% (95% CI 44.2-47.5) needed near glasses and 25.5% (95% CI 22.2-29.2) needed hearing aids. Coverage for each AD was very low (<4%). The agreement between self-report and clinical impairment assessment for AD need was poor. In conclusion, there is high prevalence and very low coverage for distance glasses, near glasses and hearing aids in The Gambia. Self-report measures alone will not provide an accurate estimate of AD need.


Assuntos
Auxiliares de Audição , Tecnologia Assistiva , Óculos , Gâmbia/epidemiologia , Humanos , Autorrelato
17.
Lancet Glob Health ; 9(4): e489-e551, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33607016
18.
Eur Radiol ; 31(5): 2809-2818, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33051734

RESUMO

OBJECTIVE: To evaluate the relation of coronary artery calcifications (CAC) on non-ECG-gated CT pulmonary angiography (CTPA) with short-term mortality in patients with acute pulmonary embolism (PE). METHODS: We retrospectively included all in-patients between May 2007 and December 2014 with an ICD-9 code for acute PE and CTPA and transthoracic echocardiography available. CAC was qualitatively graded as absent, mild, moderate, or severe. Relations of CAC with overall and PE-related 30-day mortality were assessed using logistic regression analyses. The independence of those relations was assessed using a nested approach, first adjusting for age and gender, then for RV strain, peak troponin T, and cardiovascular risk factors for an overall model. RESULTS: Four hundred seventy-nine patients were included (63 ± 16 years, 52.8% women, 47.2% men). In total, 253 (52.8%) had CAC-mild: 143 (29.9%); moderate: 89 (18.6%); severe: 21 (4.4%). Overall mortality was 8.8% (n = 42) with higher mortality with any CAC (12.6% vs. 4.4% without; odds ratio [OR] 3.1 [95%CI 2.1-14.5]; p = 0.002). Mortality with severe (19.0%; OR 5.1 [95%CI 1.4-17.9]; p = 0.011), moderate (11.2%; OR 2.7 [95%CI 1.1-6.8]; p = 0.031), and mild CAC (12.6%; OR 3.1 [95%CI 1.4-6.9]; p = 0.006) was higher than without. OR adjusted for age and gender was 2.7 (95%CI 1.0-7.1; p = 0.050) and 2.6 (95%CI 0.9-7.1; p = 0.069) for the overall model. PE-related mortality was 4.0% (n = 19) with higher mortality with any CAC (5.9% vs. 1.8% without; OR 3.5 [95%CI 1.1-10.7]; p = 0.028). PE-related mortality with severe CAC was 9.5% (OR 5.8 [95%CI 1.0-34.0]; p = 0.049), with moderate CAC 6.7% (OR 4.0 [95%CI 1.1-14.6]; p = 0.033), and with mild 4.9% (OR 2.9 [95%CI 0.8-9.9]; p = 0.099). OR adjusted for age and gender was 4.2 (95%CI 0.9-20.7; p = 0.074) and 3.4 (95%CI 0.7-17.4; p = 0.141) for the overall model. Patients with sub-massive PE showed similar results. CONCLUSION: CAC is frequent in acute PE patients and associated with short-term mortality. Visual assessment of CAC may serve as an easy, readily available tool for early risk stratification in those patients. KEY POINTS: • Coronary artery calcification assessed on computed tomography pulmonary angiography is frequent in patients with acute pulmonary embolism. • Coronary artery calcification assessed on computed tomography pulmonary angiography is associated with 30-day overall and PE-related mortality in patients with acute pulmonary embolism. • Coronary artery calcification assessed on computed tomography pulmonary angiography may serve as an additional, easy readily available tool for early risk stratification in those patients.


Assuntos
Vasos Coronários , Embolia Pulmonar , Angiografia , Angiografia por Tomografia Computadorizada , Ecocardiografia , Feminino , Humanos , Masculino , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Medição de Risco , Tomografia Computadorizada por Raios X
20.
BMJ Open ; 10(10): e036337, 2020 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-33046461

RESUMO

OBJECTIVES: To determine the prevalence and causes of blindness and vision impairment, and the coverage and quality of cataract surgical services, among population aged 50 years and older in Sohag governorate in Egypt. DESIGN: A population-based cross-sectional survey using two-stage cluster random sampling following the rapid assessment of avoidable blindness methodology. SETTING: A community-based survey conducted by six teams of ophthalmologists, assistants and local guides. Enrolment and examination were door-to-door in selected clusters. PARTICIPANTS: Using 2016 census data, 68 population units were randomly selected as clusters (of 60 people) with probability proportionate to population size. Anyone aged 50 years and older, residing in a non-institutional setting in a cluster for at least 6 months, was eligible to participate. PRIMARY AND SECONDARY OUTCOME MEASURES: The prevalence and causes of blindness and vision impairment. Secondary outcomes were CSC and effectiveness and participant-reported barriers to cataract surgery. RESULTS: Of 4078 participants enrolled, 4033 (98.9%) were examined. The age-adjusted and sex-adjusted prevalence of blindness, severe vision impairment and moderate vision impairment were 5.9% (95% CI 4.8% to 6.9%), 4.7% (95% CI 3.8% to 5.7%) and 18.9% (95% CI 16.8% to 21.0%), respectively. Cataract caused most of blindness (41.6%), followed by non-trachomatous corneal opacity (15.7%) and posterior segment diseases (14.5%). Cataract surgical coverage (CSC) for persons for visual acuity <3/60 was 86.8%, the proportion of cataract surgeries with poor visual outcome was 29.5% and effective CSC (eCSC) was 44.9%. eCSC was lower in women than men. The most frequently reported barrier to surgery was cost (51.5%). CONCLUSIONS: The prevalence of blindness in Sohag governorate is higher than districts in other middle-income countries in the region. CSC was high; however, women suffer worse quality-corrected CSC than men. The quality of cataract surgery needs to be addressed, while health system strengthening across government and private settings could alleviate financial barriers.


Assuntos
Extração de Catarata , Catarata , Idoso , Cegueira/epidemiologia , Cegueira/etiologia , Cegueira/prevenção & controle , Catarata/epidemiologia , Estudos Transversais , Egito/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA