Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 85(11): 11E806, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430371

RESUMO

Arcs are the potentially most dangerous events related to Lower Hybrid (LH) antenna operation. If left uncontrolled they can produce damage and cause plasma disruption by impurity influx. To address this issue an arc real time control and protection imaging system for the Joint European Torus (JET) LH antenna has been implemented. The LH system is one of the additional heating systems at JET. It comprises 24 microwave generators (klystrons, operating at 3.7 GHz) providing up to 5 MW of heating and current drive to the JET plasma. This is done through an antenna composed of an array of waveguides facing the plasma. The protection system presented here is based primarily on an imaging arc detection and real time control system. It has adapted the ITER like wall hotspot protection system using an identical CCD camera and real time image processing unit. A filter has been installed to avoid saturation and spurious system triggers caused by ionization light. The antenna is divided in 24 Regions Of Interest (ROIs) each one corresponding to one klystron. If an arc precursor is detected in a ROI, power is reduced locally with subsequent potential damage and plasma disruption avoided. The power is subsequently reinstated if, during a defined interval of time, arcing is confirmed not to be present by image analysis. This system was successfully commissioned during the restart phase and beginning of the 2013 scientific campaign. Since its installation and commissioning, arcs and related phenomena have been prevented. In this contribution we briefly describe the camera, image processing, and real time control systems. Most importantly, we demonstrate that an LH antenna arc protection system based on CCD camera imaging systems works. Examples of both controlled and uncontrolled LH arc events and their consequences are shown.

2.
Rev Sci Instrum ; 83(10): 10D727, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23130796

RESUMO

The new JET ITER-like wall (made of beryllium and tungsten) is more fragile than the former carbon fiber composite wall and requires active protection to prevent excessive heat loads on the plasma facing components (PFC). Analog CCD cameras operating in the near infrared wavelength are used to measure surface temperature of the PFCs. Region of interest (ROI) analysis is performed in real time and the maximum temperature measured in each ROI is sent to the vessel thermal map. The protection of the ITER-like wall system started in October 2011 and has already successfully led to a safe landing of the plasma when hot spots were observed on the Be main chamber PFCs. Divertor protection is more of a challenge due to dust deposits that often generate false hot spots. In this contribution we describe the camera, data capture and real time processing systems. We discuss the calibration strategy for the temperature measurements with cross validation with thermal IR cameras and bi-color pyrometers. Most importantly, we demonstrate that a protection system based on CCD cameras can work and show examples of hot spot detections that stop the plasma pulse. The limits of such a design and the associated constraints on the operations are also presented.

3.
J Assoc Off Anal Chem ; 61(4): 968-70, 1978 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-681270

RESUMO

A semiautomated colorimetric method is described for determining ferrous sulfate in tablets, capsules, and elixirs. The method involves the formation of an orange-red complex between 1,10-phenanthroline and ferrous ion. Collaborators were supplied with 3 solid composites and one liquid sample. Two of the solid composites were prepared from commerical tablets of different dosage and one from commercial timed-release capsules; the fourth sample was an elixir. The results of the automated analyses for ferrous sulfate agreed well with those of the applicable USP method. No interference was found from ferric iron or from the red and green coloring used on coated tablets. The method has been adopted as official first action.


Assuntos
Compostos Ferrosos/análise , Ferro/análise , Autoanálise/métodos , Formas de Dosagem , Sulfatos/análise , Comprimidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA