Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Biosens Bioelectron ; 77: 149-56, 2016 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26402593

RESUMO

Continuous glucose monitoring (CGM) sensors are often advocated as a clinical solution to improve long-term glycemic control in the context of diabetes. Subcutaneous sensor inflammatory response, fouling and fibrous encapsulation resulting from the host foreign body response (FBR) reduce sensor sensitivity to glucose, eventually resulting in sensor performance compromise and device failure. Several combination device strategies load CGM sensors with drug payloads that release locally to tissue sites to mitigate FBR-mediated sensor failure. In this study, the mast cell-targeting tyrosine kinase inhibitor, masitinib, was released from degradable polymer microspheres delivered from the surfaces of FDA-approved human commercial CGM needle-type implanted sensors in a rodent subcutaneous test bed. By targeting the mast cell c-Kit receptor and inhibiting mast cell activation and degranulation, local masitinib penetration around the CGM to several hundred microns sought to reduce sensor fibrosis to extend CGM functional lifetimes in subcutaneous sites. Drug-releasing and control CGM implants were compared in murine percutaneous implant sites for 21 days using direct-wire continuous glucose reporting. Drug-releasing implants exhibited no significant difference in CGM fibrosis at implant sites but showed relatively stable continuous sensor responses over the study period compared to blank microsphere control CGM implants.


Assuntos
Automonitorização da Glicemia/instrumentação , Glicemia/análise , Glicemia/efeitos dos fármacos , Implantes de Medicamento/administração & dosagem , Próteses e Implantes , Tiazóis/administração & dosagem , Animais , Benzamidas , Técnicas Biossensoriais/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Piperidinas , Piridinas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Plast Reconstr Surg ; 134(5): 700e-704e, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25285677

RESUMO

This study was designed to evaluate the SERI Surgical Scaffold, a silk-derived bioresorbable scaffold, in an ovine model of two-stage breast reconstruction. Sheep were implanted bilaterally with either SERI or sham sutures during the stage 1 procedure. The SERI group underwent an exchange procedure for a breast implant at 3 months; animals in the sham group were killed at 3 months. The sham samples were significantly weaker than the SERI plus tissue samples by 3 months. At all endpoints, SERI plus tissue samples were greater than or equal to 150 percent of native ovine fascial strength. Histologic evaluation of SERI samples showed evidence of bioresorption through 12 months. SERI provided adequate soft-tissue support with progressive bioresorption. By 12 months, newly formed tissue had assumed the majority of load-bearing responsibility.


Assuntos
Implantes Absorvíveis , Implantes de Mama , Mamoplastia/métodos , Alicerces Teciduais , Animais , Fenômenos Biomecânicos , Feminino , Mamoplastia/efeitos adversos , Modelos Animais , Distribuição Aleatória , Sensibilidade e Especificidade , Ovinos , Carneiro Doméstico , Resistência à Tração , Dispositivos para Expansão de Tecidos , Cicatrização/fisiologia
3.
Acta Biomater ; 10(5): 1856-63, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24406200

RESUMO

Mast cells (MCs)_are recognized for their functional role in wound-healing and allergic and inflammatory responses - host responses that are frequently detrimental to implanted biomaterials if extended beyond acute reactivity. These tissue reactions impact especially on the performance of sensing implants such as continuous glucose monitoring (CGM) devices. Our hypothesis that effective blockade of MC activity around implants could alter the host foreign body response (FBR) and enhance the in vivo lifetime of these implantable devices motivated this study. Stem cell factor and its ligand c-KIT receptor are critically important for MC survival, differentiation and degranulation. Therefore, an MC-deficient sash mouse model was used to assess MC relationships to the in vivo performance of CGM implants. Additionally, local delivery of a tyrosine kinase inhibitor (TKI) that inhibits c-KIT activity was also used to evaluate the role of MCs in modulating the FBR. Model sensor implants comprising polyester fibers coated with a rapidly dissolving polymer coating containing drug-releasing degradable microspheres were implanted subcutaneously in sash mice for various time points, and the FBR was evaluated for chronic inflammation and fibrous capsule formation around the implants. No significant differences were observed in the foreign body capsule formation between control and drug-releasing implant groups in MC-deficient mice. However, fibrous encapsulation was significantly greater around the drug-releasing implants in sash mice compared to drug-releasing implants in wild-type (e.g. MC-competent) mice. These results provide insights into the role of MCs in the FBR, suggesting that MC deficiency provides alternative pathways for host inflammatory responses to implanted biomaterials.


Assuntos
Materiais Biocompatíveis/efeitos adversos , Reação a Corpo Estranho/imunologia , Implantes Experimentais/efeitos adversos , Mastócitos/patologia , Tela Subcutânea/imunologia , Animais , Contagem de Células , Modelos Animais de Doenças , Fibrose , Corpos Estranhos/imunologia , Corpos Estranhos/patologia , Reação a Corpo Estranho/patologia , Inflamação/patologia , Ácido Láctico/química , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Polietilenoglicóis/química , Ácido Poliglicólico/química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Proteínas Proto-Oncogênicas c-kit/metabolismo , Tela Subcutânea/patologia
4.
Int J Pharm ; 456(1): 175-85, 2013 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-23933439

RESUMO

Oral delivery of camptothecin has a treatment advantage but is limited by low bioavailability and gastrointestinal toxicity. Poly(amido amine) or PAMAM dendrimers have shown promise as intestinal penetration enhancers, drug solubilizers and drug carriers for oral delivery in vitro and in situ. There have been very limited studies in vivo to evaluate PAMAM dendrimers for oral drug delivery. In this study, camptothecin (5 mg/kg) was formulated and co-delivered with cationic, amine-terminated PAMAM dendrimer generation 4.0 (G4.0) (100 and 300 mg/kg) and anionic, carboxylate-terminated PAMAM generation 3.5 (G3.5) (300 and 1000 mg/kg) in CD-1 mice. Camptothecin associated to a higher extent with G4.0 than G3.5 in the formulation, attributed to an electrostatic interaction on the surface of G4.0. Both PAMAM G4.0 and G3.5 increased camptothecin solubilization in simulated gastric fluid and caused a 2-3 fold increase in oral absorption of camptothecin when delivered at 2 h. PAMAM G4.0 and G3.5 did not increase mannitol transport suggesting that the oral absorption of camptothecin was not due to tight junction modulation. Histologic observations of the epithelial layer of small intestinal segments of the gastrointestinal tract (GIT) at 4 h post dosing supported no evidence of toxicity at the evaluated doses of PAMAM dendrimers. This study demonstrates that both cationic (G.4) and anionic (G3.5) PAMAM dendrimers were effective in enhancing the oral absorption of camptothecin. Results suggest that drug inclusion in PAMAM interior controlled solubilization in simulated gastric and intestinal fluids, and increased oral bioavailability.


Assuntos
Antineoplásicos Fitogênicos/farmacocinética , Camptotecina/farmacocinética , Dendrímeros/farmacocinética , Portadores de Fármacos/farmacocinética , Administração Oral , Animais , Antineoplásicos Fitogênicos/administração & dosagem , Antineoplásicos Fitogênicos/química , Disponibilidade Biológica , Camptotecina/administração & dosagem , Camptotecina/química , Dendrímeros/administração & dosagem , Dendrímeros/química , Portadores de Fármacos/administração & dosagem , Portadores de Fármacos/química , Feminino , Absorção Intestinal , Intestino Delgado/efeitos dos fármacos , Intestino Delgado/ultraestrutura , Camundongos , Microscopia Eletrônica de Transmissão
6.
Vet Pathol ; 48(1): 19-31, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21123864

RESUMO

Neoplastic diseases are typically diagnosed by biopsy and histopathological evaluation. The pathology report is key in determining prognosis, therapeutic decisions, and overall case management and therefore requires diagnostic accuracy, completeness, and clarity. Successful management relies on collaboration between clinical veterinarians, oncologists, and pathologists. To date there has been no standardized approach or guideline for the submission, trimming, margin evaluation, or reporting of neoplastic biopsy specimens in veterinary medicine. To address this issue, a committee consisting of veterinary pathologists and oncologists was established under the auspices of the American College of Veterinary Pathologists Oncology Committee. These consensus guidelines were subsequently reviewed and endorsed by a large international group of veterinary pathologists. These recommended guidelines are not mandated but rather exist to help clinicians and veterinary pathologists optimally handle neoplastic biopsy samples. Many of these guidelines represent the collective experience of the committee members and consensus group when assessing neoplastic lesions from veterinary patients but have not met the rigors of definitive scientific study and investigation. These questions of technique, analysis, and evaluation should be put through formal scrutiny in rigorous clinical studies in the near future so that more definitive guidelines can be derived.


Assuntos
Biópsia , Neoplasias/veterinária , Patologia Cirúrgica/normas , Guias de Prática Clínica como Assunto , Manejo de Espécimes , Medicina Veterinária/normas , Animais , Biópsia/métodos , Biópsia/normas , Biópsia/veterinária , Neoplasias/diagnóstico
7.
Vet Pathol ; 48(1): 7-18, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20664014

RESUMO

There is an increasing need for more accurate prognostic and predictive markers in veterinary oncology because of an increasing number of treatment options, the increased financial costs associated with treatment, and the emotional stress experienced by owners in association with the disease and its treatment. Numerous studies have evaluated potential prognostic and predictive markers for veterinary neoplastic diseases, but there are no established guidelines or standards for the conduct and reporting of prognostic studies in veterinary medicine. This lack of standardization has made the evaluation and comparison of studies difficult. Most important, translating these results to clinical applications is problematic. To address this issue, the American College of Veterinary Pathologists' Oncology Committee organized an initiative to establish guidelines for the conduct and reporting of prognostic studies in veterinary oncology. The goal of this initiative is to increase the quality and standardization of veterinary prognostic studies to facilitate independent evaluation, validation, comparison, and implementation of study results. This article represents a consensus statement on the conduct and reporting of prognostic studies in veterinary oncology from veterinary pathologists and oncologists from around the world. These guidelines should be considered a recommendation based on the current state of knowledge in the field, and they will need to be continually reevaluated and revised as the field of veterinary oncology continues to progress. As mentioned, these guidelines were developed through an initiative of the American College of Veterinary Pathologists' Oncology Committee, and they have been reviewed and endorsed by the World Small Animal Veterinary Association.


Assuntos
Oncologia/normas , Neoplasias/veterinária , Guias de Prática Clínica como Assunto , Medicina Veterinária/normas , Animais , Progressão da Doença , Neoplasias/patologia , Prognóstico
11.
Vet Surg ; 21(5): 348-50, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1413467

RESUMO

Freshly harvested equine skin incised with an electrosurgical unit, a radiosurgical device, or a carbon dioxide (CO2) laser was examined by light microscopy to determine the extent of thermal injury caused by each instrument. There was no significant difference between the thermal injury caused by the electrosurgical unit in the pure-cut mode and the CO2 laser in the superpulse mode, or between the electrosurgical unit and the radiosurgical device in the fully filtered cut mode. However, thermal injury caused by the CO2 laser was significantly less than that caused by the radiosurgical device. The amount of thermal injury in this in vitro study was similar to that found in vivo with other species.


Assuntos
Queimaduras/veterinária , Eletrocirurgia/veterinária , Terapia a Laser/veterinária , Radiocirurgia/veterinária , Pele/lesões , Análise de Variância , Animais , Queimaduras/etiologia , Técnicas de Cultura , Eletrocirurgia/efeitos adversos , Cavalos , Terapia a Laser/efeitos adversos , Radiocirurgia/efeitos adversos
12.
Toxicol Appl Pharmacol ; 103(1): 40-51, 1990 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-2315931

RESUMO

A high dose (550 mg/kg) of 3-methylindole (3MI) specifically damaged pulmonary tissue in Swiss-Webster mice without causing any hepatic or renal necrosis. When a glutathione depleter, L-buthionine-(S,R)-sulfoximine (BSO, 1.0 mmol/kg), was administered to mice 3 hr before a low dose of 3-methylindole (75 mg/kg), significant renal damage was observed by histopathological examination after 4 hr. The nephrotoxicity occurred without any observable pathological damage to lung tissues. Increased doses of BSO caused dose-dependent increases in renal toxicity. A low dose of BSO (1.0 mmol/kg) caused no depletion of renal glutathione levels, a large depletion of hepatic glutathione levels (60% of control values), and much larger increases in covalent binding of [methyl-14C]3-methylindole to renal tissues (3.4-fold) than to hepatic tissues (1.5-fold) or pulmonary tissues (2.1-fold). No evidence of hepatic or pulmonary histopathological damage was observed at any dose of BSO with 75 mg/kg 3MI. These results indicate that a shift in organ selectivity of 3MI-induced toxicity from pulmonary to renal sites occurs as a result of glutathione depletion in hepatic tissues. The production of a toxic metabolite in the livers of glutathione-depleted mice that is circulated to susceptible renal cells may be the mechanism of this interesting organ-selective shift in toxicity of 3MI.


Assuntos
Glutationa/fisiologia , Indóis/toxicidade , Escatol/toxicidade , Animais , Butionina Sulfoximina , Relação Dose-Resposta a Droga , Glutationa/análise , Rim/efeitos dos fármacos , Rim/patologia , Fígado/efeitos dos fármacos , Fígado/patologia , Pulmão/efeitos dos fármacos , Pulmão/patologia , Masculino , Metionina Sulfoximina/análogos & derivados , Metionina Sulfoximina/farmacologia , Camundongos , Especificidade de Órgãos , Ligação Proteica , Escatol/metabolismo
13.
Artigo em Inglês | MEDLINE | ID: mdl-7331167

RESUMO

In a group of 76 calves maintained with Jarvik-5 and Jarvik-7 artificial hearts, pannus formation in the atrial location was evaluated retrospectively using a grading system based on measurement of the pannus tissue. Pannus was present in 87% of the calves surviving one to 7 mos with an old-style inflow quick-connect design utilizing polyester felt surfaces. This design had a suboptimal hemodynamic flow path. Using a new design of quick-connect with an improved hemodynamic flow path and a Biomer blood-contacting surface, pannus occurred only in 17% of calves surviving one to 9 mos. Furthermore, the pannus formation with the new design was mild in the 2 cases where it occurred, whereas the pannus formation in animals with the old cuffs was frequently severe. One calf survived 9 mos with no pannus formation utilizing our new quick-connect system, and we conclude that pannus is no longer a problem in our experiments. We also reviewed the relation of pannus to anticoagulant regimens and found that Persantine, Coumadin, and aspirin were not effective in preventing pannus when the inflow cuff design was conducive to its development.


Assuntos
Coração Artificial/efeitos adversos , Miocárdio/patologia , Animais , Bovinos , Coração Artificial/mortalidade
15.
Can J Comp Med ; 43(1): 84-9, 1979 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-218708

RESUMO

Seventy-nine diarrheic calf fecal samples were examined by electron microscopy, immunodiffusion and the fluorescent antibody technique for the presence of rotavirus (reovirus-like agent). Thirty-eight (48%) of the samples were positive by electron microscopy, 59% by immunodiffusion and 20% positive by fluorescent antibody technique analyses. Another 9% were suspect-positive by fluorescent antibody technique. Chymotrypsin treatment of the fecal samples increased the ease of observing the viral particles by electron microscopy and also intensified the immunodiffusion arcs obtained. Immunodiffusion analyses using specific antisera to the virus would appear to be a practical method of detecting rotavirus in diarrheic fecal samples.


Assuntos
Doenças dos Bovinos/microbiologia , Diarreia/veterinária , Fezes/microbiologia , Vírus de RNA/isolamento & purificação , Rotavirus/isolamento & purificação , Animais , Bovinos , Quimotripsina/farmacologia , Diarreia/microbiologia , Fezes/efeitos dos fármacos , Imunofluorescência , Imunodifusão , Microscopia Eletrônica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA