Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
2.
Lancet ; 403(10427): 657-664, 2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38335982

RESUMO

BACKGROUND: A rapid and affordable point-of-care test is a priority for Neisseria gonorrhoeae control. WHO and Foundation for Innovative New Diagnostics (FIND) have a target product profile for a non-molecular N gonorrhoeae rapid point-of-care test that requires a clinical sensitivity of greater than 80% and a specificity over 95% to be considered useful in syndromic management; test turnaround time should be 30 min or under, and the test should cost less than US$3. A novel lateral flow assay (LFA) was developed to achieve that profile. METHODS: In this cross-sectional study we evaluated the performance of the novel N gonorrhoeae lateral flow assay (NG-LFA) at the primary health-care level in South Africa. Male patients with urethral discharge syndrome and female patients with vaginal discharge syndrome were recruited from five primary health-care facilities in the Buffalo City Metropolitan Municipality health district of South Africa. First-void urine specimens and nurse-collected vaginal swabs were tested in-facility with the NG-LFA and Xpert CT/NG PCR assay. N gonorrhoeae multi-antigen sequence typing (NG-MAST) was performed on all LFA positive specimens. FINDINGS: Between March 7, and Sept 19, 2022, we enrolled 200 male patients with urethral discharge and 200 female patients with vaginal discharge. The median age of male patients was 24 years (IQR 21-31 years), and the median age of female patients was 25 years (IQR 21-32 years). In addition, 23 male patients and 12 female patients who presented at the facility with a partner notification slip were enrolled of whom one (4%) and five (42%) were symptomatic, respectively. NG-LFA and Xpert results were available for all participants. In urine specimens, NG-LFA sensitivity was 96·1% (Wilson 95% CI 91·2-98·3; 123 LFA-positive among 128 PCR-positive specimens) and 91·7% in vaginal swab specimens (78·2-97·1; 33 LFA-positive among 36 PCR-positive). The specificity was 97·2% in urine specimens (90·4-99·2; 70 LFA-negative among 72 PCR-negative) and 96·3% in vaginal specimens (92·2-98·3; 158 LFA-negative among 164 PCR-negative). In 156 LFA-positive specimens, NG-MAST showed 93 different sequence types. INTERPRETATION: The novel NG-LFA had excellent clinical sensitivity and specificity in symptomatic male and female patients. The test met the optimal requirement for sensitivity and the minimal requirement for specificity specified in the target product profile. NG-LFA could provide an important tool to optimise clinical management and reduce excess antibiotic use in settings without direct access to laboratory testing. FUNDING: Global Antimicrobial Resistance Innovation Fund (GAMRIF) via FIND and National Institutes of Health.


Assuntos
Infecções por Chlamydia , Gonorreia , Descarga Vaginal , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Gonorreia/diagnóstico , Estudos Transversais , Sistemas Automatizados de Assistência Junto ao Leito , Infecções por Chlamydia/diagnóstico , Chlamydia trachomatis , Neisseria gonorrhoeae , Sensibilidade e Especificidade
3.
BMC Health Serv Res ; 24(1): 43, 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38195446

RESUMO

BACKGROUND: South Africa maintains an integrated health system where syndromic management of sexually transmitted infections (STI) is the standard of care. An estimated 2 million cases of Neisseria gonorrhoeae (N. gonorrhoeae) occur in South Africa every year. Point-of-care diagnostic tests (POCT) may address existing STI control limitations such as overtreatment and missed cases. Subsequently, a rapid lateral flow assay with fluorescence-based detection (NG-LFA) with a prototype reader was developed for N. gonorrhoeae detection showing excellent performance and high usability; however, a better understanding is needed for device implementation and integration into clinics. METHODS: A qualitative, time-series assessment using 66 in-depth interviews was conducted among 25 trained healthcare workers involved in the implementation of the NG-LFA. Findings were informed by the Normalization Process Theory (NPT) as per relevant contextual (strategic intentions, adaptive execution, and negotiation capacity) and procedural constructs (coherence, cognitive participation, collective action, reflexive monitoring) to examine device implementation within primary healthcare levels. Interviews were audio-recorded, transcribed, and then analyzed using a thematic approach guided by NPT to interpret results. RESULTS: Overall, healthcare workers agreed that STI POCT could guide better STI clinical decision-making, with consideration for clinic integration such as space constraints, patient flow, and workload. Perceived NG-LFA benefits included enhanced patient receptivity and STI knowledge. Further, healthcare workers reflected on the suitability of the NG-LFA given current limitations with integrated primary care. Recommendations included sufficient STI education, and appropriate departments for first points of entry for STI screening. CONCLUSIONS: The collective action and participation by healthcare workers in the implementation of the NG-LFA revealed adaptive execution within the current facility environment including team compositions, facility-staff receptivity, and STI management experiences. User experiences support future clinic service integration, highlighting the importance of further assessing patient-provider communication for STI care, organizational readiness, and identification of relevant departments for STI screening.


Assuntos
Neisseria gonorrhoeae , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , África do Sul , Testes de Diagnóstico Rápido , Testes Imediatos , Atenção Primária à Saúde
4.
BMJ Open ; 13(12): e081562, 2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38154893

RESUMO

INTRODUCTION: Preterm birth complications are the most common cause of death in children under 5 years. The presence of multiple microorganisms and genital tract inflammation could be the common mechanism driving early onset of labour. South Africa has high levels of preterm birth, genital tract infections and HIV infection among pregnant women. We plan to investigate associations between the presence of multiple lower genital tract microorganisms in pregnancy and gestational age at birth. METHODS AND ANALYSIS: This cohort study enrols around 600 pregnant women at one public healthcare facility in East London, South Africa. Eligible women are ≥18 years and at <27 weeks of gestation, confirmed by ultrasound. At enrolment and 30-34 weeks of pregnancy, participants receive on-site tests for Chlamydia trachomatis and Neisseria gonorrhoeae, with treatment if test results are positive. At these visits, additional vaginal specimens are taken for: PCR detection and quantification of Trichomonas vaginalis, Candida spp., Mycoplasma genitalium, M. hominis, Ureaplasma urealyticum and U. parvum; microscopy and Nugent scoring; and for 16S ribosomal RNA gene sequencing and quantification. Pregnancy outcomes are collected from a postnatal visit and birth registers. The primary outcome is gestational age at birth. Statistical analyses will explore associations between specific microorganisms and gestational age at birth. To explore the association with the quantity of microorganisms, we will construct an index of microorganism load and use mixed-effects regression models and classification and regression tree analysis to examine which combinations of microorganisms contribute to earlier gestational age at birth. ETHICS AND DISSEMINATION: This protocol has approvals from the University of Cape Town Research Ethics Committee and the Canton of Bern Ethics Committee. Results from this study will be uploaded to preprint servers, submitted to open access peer-reviewed journals and presented at regional and international conferences. TRIAL REGISTRATION NUMBER: NCT06131749; Pre-results.


Assuntos
Infecções por HIV , Infecções por Mycoplasma , Complicações Infecciosas na Gravidez , Nascimento Prematuro , Infecções do Sistema Genital , Criança , Feminino , Gravidez , Recém-Nascido , Humanos , Pré-Escolar , Nascimento Prematuro/epidemiologia , Gestantes , Estudos de Coortes , Infecções por HIV/complicações , Idade Gestacional , Infecções do Sistema Genital/epidemiologia , África do Sul/epidemiologia , Resultado da Gravidez , Chlamydia trachomatis
5.
Sex Transm Dis ; 50(12): 821-826, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37820114

RESUMO

BACKGROUND: There is a paucity of Neisseria gonorrhoeae antimicrobial resistance data from resource-constrained settings because of the lack of diagnostic testing and limited scale of surveillance programs. This study aimed to determine the antimicrobial resistance profile of N. gonorrhoeae in the rural Eastern Cape province of South Africa. METHODS: Specimens for N. gonorrhoeae culture were obtained from men with urethral discharge and women with vaginal discharge attending primary health care facilities. Direct inoculation of the agar plates was performed followed by culture and drug susceptibility testing using the Etest at the laboratory. Whole-genome sequencing of the isolates was performed to identify resistance-determining variants. RESULTS: One hundred N. gonorrhoeae isolates were obtained. Most strains were nonsusceptible to ciprofloxacin (76%), tetracycline (75%), and penicillin G (72%). The gyrA S91F mutation was present in 68 of 72 ciprofloxacin-resistant isolates (94%), with concurrent parC mutations in 47 of 68 (69%); gyrA I250M was the only mutation in 4 other resistant strains. One azithromycin-resistant isolate was identified with a minimal inhibitory concentration (MIC) of 8.0 mg/L and the 23S rDNA gene mutation C2597T. The median MIC of cefixime was 0.016 mg/L (range, 0.016-0.064 mg/L), and that of ceftriaxone was 0.016 mg/L (range, 0.016 mg/L). Whole-genome sequencing showed 58 sequence types as revealed in N. gonorrhoeae sequence typing for antimicrobial resistance and 70 sequence types in N. gonorrhoeae multiantigen sequence typing. CONCLUSIONS: This study confirmed high rates of N. gonorrhoeae antimicrobial resistance to ciprofloxacin, penicillin G, and tetracycline in our setting. The MICs of cephalosporins are reassuring for ceftriaxone use in syndromic treatment regimens, but the identification of azithromycin resistance warrants further attention.


Assuntos
Gonorreia , Mycobacterium tuberculosis , Masculino , Feminino , Humanos , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Neisseria gonorrhoeae/genética , Azitromicina/farmacologia , Azitromicina/uso terapêutico , Ceftriaxona/farmacologia , Ceftriaxona/uso terapêutico , Testes de Sensibilidade Microbiana , África do Sul/epidemiologia , Farmacorresistência Bacteriana/genética , Mycobacterium tuberculosis/genética , Gonorreia/tratamento farmacológico , Gonorreia/epidemiologia , Ciprofloxacina/farmacologia , Ciprofloxacina/uso terapêutico , Tetraciclina/farmacologia , Tetraciclina/uso terapêutico , Penicilina G/uso terapêutico , Tipagem Molecular
7.
PLoS One ; 18(6): e0286666, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37267319

RESUMO

Accurate and user-friendly rapid point-of-care diagnostic tests (POCT) are needed to optimize treatment of Neisseria gonorrhoeae, especially in low-resource settings where syndromic management is the standard of care for sexually transmitted infections. This study aimed to assess the acceptability and usability of a novel lateral flow assay and portable reader for the point-of-care detection of N. gonorrhoeae infection (NG-LFA). This mixed-methods study was conducted as part of a diagnostic performance and usability evaluation of a prototype NG-LFA for detection of N. gonorrhoeae in symptomatic men and women at primary healthcare facilities in the Buffalo City Metro, South Africa. The Standardized System Usability Scale (SUS) was administered, and in-depth interviews were conducted among healthcare professionals (HCPs) and fieldworkers (FWs) at pre-implementation, initial use and 3- and 6-month study implementation to assess user expectations, practical experience, and future implementation considerations for the NG-LFA. Data collection and analysis was guided by the Health Technology Adoption Framework, including new health technology attributes, learnability, satisfaction, and suitability. The framework was adapted to include perceived durability. A total of 21 HCPs and FWs were trained on the NG-LFA use. SUS scores showed good to excellent acceptability ranging from 78.8-90.6 mean scores between HCPs and FWs across study time points. All transcripts were coded using Dedoose and qualitative findings were organized by learnability, satisfaction, suitability, and durability domains. Usability themes are described for each time point. Initial insecurity dissipated and specimen processing dexterity with novel POCT technology was perfected over time especially amongst FWs through practical learning and easy-to-use instructions (learnability). Participants experienced both positive and negative test results, yielding perceived accuracy and minimal testing challenges overall (satisfaction). By 3- and 6-month use, both HCPs and FWs found the NG-LFA convenient to use in primary health care facilities often faced with space constraints and outlined perceived benefits for patients (suitability and durability). Findings show that the NG-LFA device is acceptable and usable even amongst paraprofessionals. High SUS scores and qualitative findings demonstrate high learnability, ease-of-use and suitability that provide valuable information for first-step scale-up requirements at primary healthcare level. Minor prototype adjustments would enhance robustness and durability aspects.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Infecções Sexualmente Transmissíveis , Feminino , Humanos , Neisseria gonorrhoeae , África do Sul , Infecções Sexualmente Transmissíveis/diagnóstico , Pessoal de Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA