Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Br J Ophthalmol ; 100(8): 1098-101, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26719491

RESUMO

PURPOSE: NewColorIris cosmetic iris implants have a record of high ocular morbidity and are no longer in use. Newer generation of iris implants, BrightOcular, have patented posterior grooves in order to decrease iris touch and facilitate aqueous flow around the implant. However, little is known about their safety despite their implantations in 10 countries. METHODS: Collaborative case series of patients who had bilateral implantation of cosmetic iris implants solely for cosmetic reasons. RESULTS: 12 cases were collected being distributed as Caucasian (10) and Asian (2), women (11) and man (1) and with a mean age of 32 years. Ocular manifestations were present in 11 subjects and included anterior uveitis (10 of 12; 83.3%), glaucoma (7 of 12; 58.3%) and corneal decompensation (6 of 12; 50%). Visual acuity was normal in seven, decreased in five with two having visual recovery following explantation of the implant. Glaucoma could not be controlled medically in two patients. CONCLUSIONS: Cosmetic iris implants carry the risk of ocular damage when implanted in the anterior chamber of normal phakic eyes.


Assuntos
Perda de Células Endoteliais da Córnea/etiologia , Glaucoma/etiologia , Iris/cirurgia , Irite/etiologia , Complicações Pós-Operatórias , Próteses e Implantes/efeitos adversos , Acuidade Visual , Adulto , Perda de Células Endoteliais da Córnea/diagnóstico , Remoção de Dispositivo , Cor de Olho , Feminino , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Irite/diagnóstico , Masculino , Falha de Prótese , Adulto Jovem
2.
Cont Lens Anterior Eye ; 38(4): 245-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25754008

RESUMO

PURPOSE: To present the first reported series of patients undergoing myopic LASIK with the FEMTO LDV Crystal Line femtosecond laser and the WaveLight Allegretto Eye-Q excimer laser. We report the uncorrected and corrected distance visual acuity (UDVA and CDVA), refractive predictability, efficacy and safety of laser in situ keratomileusis (LASIK) performed with the above laser platforms. METHODS: This prospective interventional case series study evaluated consecutive eyes with low to moderate myopic astigmatism that underwent LASIK with the FEMTO LDV Crystal Line femtosecond laser and the WaveLight Allegretto Eye-Q 400 Hz excimer laser. Visual and refractive changes as well as complications were evaluated after wavefront-optimized laser treatment. RESULTS: Four hundred and forty four patients (887 eyes) reached the 6-month time gate. Mean age at time of procedure was 31 years (range: 20-59). Mean pre-op spherical-equivalent (SE) was -3.44 diopters (D)±1.34D (range: -0.50 to -7.00) whilst the postoperative spherical equivalent decreased to -0.08±0.31D (range -2.25 to 1.00). At 6-month follow up, 96.9% of patients had monocular uncorrected distance visual acuity of 20/20 or better with 95.2% of patients within ±0.5D of intended refractive outcome. All patients achieved 20/20 binocular distance uncorrected visual acuity. No significant intra-operative or postoperative complications were encountered during the 6-month follow-up period. CONCLUSIONS: The combination of the above laser platforms provides safe, effective and predictable results in correcting compound myopic astigmatism with excellent visual outcomes.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ/instrumentação , Lasers de Excimer/uso terapêutico , Miopia/diagnóstico , Miopia/cirurgia , Transtornos da Visão/diagnóstico , Transtornos da Visão/prevenção & controle , Adulto , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Miopia/complicações , Resultado do Tratamento , Transtornos da Visão/etiologia , Acuidade Visual
3.
Cont Lens Anterior Eye ; 37(5): 388-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24947123

RESUMO

An unusual case of eyelashes being traumatically inserted into the corneal stroma is presented. A 75-year-old hit her right eye with her own fist, presenting with intra-corneal eyelashes. All remained entirely within the cornea, with no breach of the endothelium. They seemed to have tracked there first through the superior conjunctiva and then the superior limbus. The lashes were surgically removed, with good visual recovery. The authors present a short review of intra-ocular eyelash insertion.


Assuntos
Lesões da Córnea/diagnóstico , Substância Própria/lesões , Ferimentos Oculares Penetrantes/diagnóstico , Pestanas , Idoso , Lesões da Córnea/cirurgia , Substância Própria/patologia , Ferimentos Oculares Penetrantes/cirurgia , Feminino , Seguimentos , Humanos , Procedimentos Cirúrgicos Oftalmológicos/métodos
4.
J Cataract Refract Surg ; 39(7): 1116-7, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23680633

RESUMO

UNLABELLED: We describe the surgical correction of a 32-year-old pseudophakic patient with the Kamra corneal inlay. To our knowledge, this is the youngest patient to have such a procedure. FINANCIAL DISCLOSURE: Neither author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Cirurgia da Córnea a Laser , Implante de Lente Intraocular , Facoemulsificação , Implantação de Prótese , Pseudofacia/etiologia , Transtornos da Visão/cirurgia , Adulto , Catarata/etiologia , Catarata/reabilitação , Traumatismos Oculares/etiologia , Traumatismos Oculares/reabilitação , Humanos , Lasers de Excimer/uso terapêutico , Cristalino/lesões , Masculino , Transtornos da Visão/etiologia , Acuidade Visual/fisiologia
5.
Cornea ; 32(7): e164-6, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23594769

RESUMO

PURPOSE: To report spontaneous corneal clearing with improved visual acuity and central endothelial cell repopulation after the removal of a dislocated donor button following Descemet stripping endothelial keratoplasty (DSEK). METHODS: Interventional case report. RESULTS: An 84-year-old woman with decreased visual acuity in the right eye secondary to Fuchs endothelial dystrophy and cataract underwent combined cataract extraction, intraocular lens implantation, and DSEK. After primary graft failure, the resulting detached, opaque, and retracted donor lenticule was removed from the eye 2 months after the initial surgery and not replaced. The cornea started to clear after the donor button removal with central endothelial cell repopulation. CONCLUSIONS: Corneal deturgescence is not strictly dependent on donor lenticule adhesion to the host posterior stromal surface. Endothelial cell migration and repopulation of the central cornea can occur after DSEK and after the removal of the failed endothelial graft, with corneal clearing and improved visual outcomes.


Assuntos
Córnea/fisiopatologia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Endotélio Corneano/cirurgia , Distrofia Endotelial de Fuchs/cirurgia , Rejeição de Enxerto/cirurgia , Facoemulsificação , Idoso de 80 Anos ou mais , Catarata/complicações , Contagem de Células , Perda de Células Endoteliais da Córnea/patologia , Lâmina Limitante Posterior , Endotélio Corneano/patologia , Feminino , Distrofia Endotelial de Fuchs/complicações , Rejeição de Enxerto/etiologia , Humanos , Implante de Lente Intraocular , Falha de Tratamento , Acuidade Visual/fisiologia
6.
Cont Lens Anterior Eye ; 35(1): 46-7, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21885327

RESUMO

Penetrating injuries from non-venomous snakebites are, thankfully, rare. They are, however, sight-threatening and the recent trend for using non-venomous snakes as props in the entertainment industry is increasing exposure of this hazard to people with no animal handling training. We report a case of a penetrating corneal injury in a 35 year old woman following a bite from a snake she had been given to hold for a photograph opportunity. The injury was repaired surgically and she had a good visual outcome, largely due to very good fortune in the site and nature of the injury. This case highlights the danger of exposing untrained handlers to snakes in the entertainment industry.


Assuntos
Boidae , Córnea/cirurgia , Lesões da Córnea , Mordeduras de Serpentes/complicações , Mordeduras de Serpentes/cirurgia , Ferimentos Penetrantes/etiologia , Ferimentos Penetrantes/cirurgia , Adulto , Animais , Feminino , Humanos , Doenças Raras , Mordeduras de Serpentes/diagnóstico , Resultado do Tratamento , Ferimentos Penetrantes/diagnóstico
7.
Cont Lens Anterior Eye ; 33(5): 235-8, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20382066

RESUMO

PURPOSE: To report the management of complications due to cosmetic iris implantation. DESIGN: Interventional case report. METHODS: A 27-year-old female underwent bilateral anterior chamber NewColorIris implants in Panama to cosmetically change her eye colour. Two weeks later she presented as an eye emergency in London with corneal decompensation, raised intraocular pressure and significantly reduced vision. Bilateral explantation was performed with good postoperative recovery. RESULTS: Three months following explantation, visual acuity had normalized and intraocular pressure was within the normal range without medication. CONCLUSIONS: Cosmetic iris implantation can lead to potentially sight threatening complications. This is the first case to be reported in the United Kingdom. There is a lack of published safety data and their cosmetic application should be cautioned against.


Assuntos
Câmara Anterior/cirurgia , Oftalmopatias/etiologia , Olho Artificial/efeitos adversos , Iris/cirurgia , Procedimentos Cirúrgicos Oftalmológicos/efeitos adversos , Pigmentação em Prótese , Cirurgia Plástica/efeitos adversos , Transtornos da Visão/etiologia , Adulto , Doenças da Córnea/etiologia , Remoção de Dispositivo , Oftalmopatias/fisiopatologia , Oftalmopatias/cirurgia , Feminino , Humanos , Hipertensão Ocular/etiologia , Período Pós-Operatório , Reoperação , Transtornos da Visão/fisiopatologia , Transtornos da Visão/cirurgia , Acuidade Visual
8.
Cont Lens Anterior Eye ; 32(1): 33-4, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18707917

RESUMO

PURPOSE: To describe a case of airbag-induced corneal flap in a previously normal cornea. METHODS: Case report. RESULTS: A 27-year-old woman presented with complete loss of vision in her left eye following a road traffic accident which involved airbag deployment. There was no previous ocular history. Examination revealed a large corneal flap of 6mm in diameter, extending to the depth of anterior stroma. This was accompanied by a traumatic optic neuropathy. One month follow-up revealed complete reattachment of the corneal flap. CONCLUSIONS: This is the first reported case of a corneal flap induced by airbag deployment in a cornea with previously normal architecture.


Assuntos
Acidentes de Trânsito , Air Bags/efeitos adversos , Doenças da Córnea/etiologia , Lesões da Córnea , Traumatismos Oculares/patologia , Ferimentos não Penetrantes/patologia , Adulto , Córnea/patologia , Doenças da Córnea/patologia , Dilatação Patológica , Feminino , Seguimentos , Humanos , Ruptura
9.
Int Ophthalmol ; 29(3): 157-60, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18401555

RESUMO

PURPOSE: To determine the visual outcome of patients following cataract surgery complicated by vitreous loss and to establish the factors, if any, that influenced the final visual outcome. METHODS: Retrospective review of all patients over a 1-year period who had planned phacoemulsification complicated by vitreous loss. Information was entered into a pre-devised proforma and the results analysed. RESULTS: Of the 1614 eyes operated on for cataract, 43 (2.66%) had surgery complicated by vitreous loss. The mean age of the patients experiencing surgical complications was 79.7 years (range 48-93 years). Twenty-three patients (53%) had at least one factor contributing to the difficulty of procedure, with dense cataract being the top factor in 11 patients. There was no statistically significant association between any pre-operative predisposing factor, stage at which vitreous loss occurred, grade of the surgeon and final visual outcome. When pre-existing co-morbidity was excluded, 26 of 30 (87%) patients achieved a best-corrected visual acuity of 6/12 or better post-operatively. Cystoid macula oedema was the underlying cause in 50% of those patients that lost one or more lines post-operatively. CONCLUSIONS: Surgeons at all levels of training had an acceptable complication rate, with the majority of patients achieving a good visual outcome. Dense cataract was the most common factor contributing to the complexity of the surgery.


Assuntos
Hospitais de Distrito/estatística & dados numéricos , Facoemulsificação/efeitos adversos , Complicações Pós-Operatórias , Acuidade Visual , Corpo Vítreo/patologia , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Resultado do Tratamento
10.
J Refract Surg ; 24(9): 885-90, 2008 11.
Artigo em Inglês | MEDLINE | ID: mdl-19044228

RESUMO

PURPOSE: To compare the safety, efficacy, and predictability of LASIK with the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-Q excimer laser platforms. METHODS: This prospective study comprised 44 eyes of 22 consecutive patients who were treated with LASIK using the Moria M2 microkeratome. One eye was treated with the SCHWIND ESIRIS laser and the fellow eye treated with the WaveLight ALLEGRETTO WAVE Eye-Q laser. All eyes operated with the SCHWIND ESIRIS were treated with standard aspheric ablation, whereas the eyes operated with the WaveLight ALLEGRETTO WAVE Eye-Q received treatment with three different ablation types according to the common practice at our clinic. Outcome measures were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, and proximity to target refraction at 6-month follow-up. RESULTS: At 6 months postoperative, mean decimal UCVA was 0.96+/-0.22 (range: 0.3 to 1.2) for ESIRIS eyes and 0.98+/-0.17 (range: 0.6 to 1.2) for ALLEGRETTO eyes (P=.57). Mean postoperative spherical equivalent refraction was -0.02+/-0.28 diopters (D) (range: -0.75 to +0.75 D) for ESIRIS eyes and 0.11+/-0.91 D (range: -1.00 to +3.88 D) for ALLEGRETTO eyes (P=.49). Of the ESIRIS eyes, 20/22 (91%) were within +/-1.00 D of target refraction and 20/22 (91%) were within +/-0.50 D of target refraction. Of the ALLEGRETTO eyes, 20/22 (91%) and 19/22 (86%) were within +/-1.00 D and +/-0.50 D, respectively, of target refraction. No patient lost > or =2 lines of BSCVA in either group. CONCLUSIONS: No differences were seen in safety and efficacy outcome parameters between the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-Q excimer lasers when used according to a previously established treatment algorithm at our clinic in the treatment of refractive error.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
11.
Cont Lens Anterior Eye ; 31(3): 117-21, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18406656

RESUMO

True presbyopia correction still remains one of the main challenges amongst eye professionals. Many corrective techniques exist including bifocal spectacle correction, monovision techniques both with corrective lenses and surgery, multifocal corneal excimer laser and refractive lens exchange with either accommodating or multifocal lenses. Refractive lens exchange was first described more than 10 years ago and has become more accepted in recent years with advancements in lens technology and improvements in surgical techniques. This article reviews developments in this field and current available lens options in the treatment of presbyopia.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Presbiopia/cirurgia , Procedimentos Cirúrgicos Refrativos , Acomodação Ocular/fisiologia , Humanos , Cristalino/cirurgia , Presbiopia/fisiopatologia , Acuidade Visual/fisiologia
12.
Expert Opin Drug Saf ; 7(1): 79-89, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18171316

RESUMO

Ciclosporin is a calcineurin inhibitor that acts by primarily inhibiting the action of T cells. Clinical trials in the early 1980s demonstrated that systemic ciclosporin was a promising steroid-sparing agent and was also effective in patients who are refractory to treatment with corticosteroids. However, recent years have witnessed the emergence of safer immunosuppressive agents due to the poor side-effect profile of systemic ciclosporin. Topical ciclosporin, however, has a much improved safety profile and is still used to treat a variety of ocular surface disorders including dry eye syndrome, vernal and atopic keratoconjunctivitis, severe blepharitis and high-risk corneal graft patients. This article reviews the uses and safety profile of systemic and topical ciclosporin in ophthalmology, as well as discussing alternative therapeutic agents available.


Assuntos
Ciclosporina/efeitos adversos , Oftalmologia/tendências , Administração Tópica , Animais , Ciclosporina/uso terapêutico , Oftalmopatias/tratamento farmacológico , Oftalmopatias/imunologia , Humanos , Oftalmologia/métodos
13.
Cont Lens Anterior Eye ; 31(1): 38-40, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17964211

RESUMO

PURPOSE: To report a case of airbag induced corneal ectasia. METHODS: Case report. RESULTS: A patient 3 years post-LASIK developed bilateral corneal ectasia worse in the right eye following airbag deployment in a road traffic accident. At last follow up, best corrected vision was 20/40 with -4.00/-4.00 x 25 in the right eye and 20/25 with -1.25/-0.50 x 135 in the left eye. CONCLUSIONS: This is a rare presentation of trauma induced ectasia in a patient post-LASIK. It is possible that reduction in biomechanical integrity of the cornea from prior refractive surgery contributed to this presentation.


Assuntos
Air Bags/efeitos adversos , Doenças da Córnea/diagnóstico , Doenças da Córnea/etiologia , Traumatismos Oculares/diagnóstico , Traumatismos Oculares/etiologia , Adulto , Doenças da Córnea/terapia , Dilatação Patológica/diagnóstico , Dilatação Patológica/etiologia , Dilatação Patológica/terapia , Traumatismos Oculares/terapia , Humanos , Masculino
14.
Cornea ; 26(3): 279-83, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17413953

RESUMO

PURPOSE: To report our clinical experience and 12-month results of small-incision Descemet-stripping endothelial keratoplasty (DSEK). METHODS: Prospective study of 11 eyes of 9 patients who had DSEK. The DSEK technique consisted of stripping the Descemet membrane and endothelium from the recipient cornea. The donor button was prepared by manual dissection and inserted through a 5-mm incision. Air, sulfur hexafluoride (SF6), or perfluoropropane (C3F8) was used both at the end of surgery and in subsequent dislocations to promote donor tissue adherence. RESULTS: Mean age was 79.6 years (range, 66-91 years), and minimum follow-up was 12 months (range, 12-18 months). Nine eyes had donor tissue dislocation postoperatively, 8 of which received intervention with either SF6 (n = 4) or C3F8 (n = 4). In 1 patient with repeat dislocation, Tisseel glue in combination with C3F8 was used. Preoperative best-corrected visual acuity (BCVA) was 6/24 or worse in all patients. Postoperatively, 6/11 eyes (55%) achieved a BCVA of 6/12 at last follow-up. Mean preoperative cylinder was 1.875 +/- 0.906 D (range, 1-3 D) and postoperatively was 1.5 +/- 1.157 D (range, 0.25-3.25 D). At last follow-up, 6 grafts were clear and 5 had failed. Mean endothelial cell count in the clear grafts at 12-month follow-up was 1078 +/- 507 cells/mm. CONCLUSIONS: DSEK provided excellent refractive and reasonable visual outcomes in our limited series, but there were frequent problems with dislocation of the donor tissue, and the graft failure rate was high. The graft failures may be linked to excessive endothelial damage, and the high dislocation rate may be linked to not filling the anterior chamber totally with air after insertion of the donor. Further development of the procedure is necessary.


Assuntos
Transplante de Córnea/métodos , Lâmina Limitante Posterior/cirurgia , Endotélio Corneano/transplante , Distrofia Endotelial de Fuchs/cirurgia , Microcirurgia , Idoso , Idoso de 80 Anos ou mais , Ar , Fluorocarbonos/administração & dosagem , Humanos , Implante de Lente Intraocular , Facoemulsificação , Prognóstico , Estudos Prospectivos , Refração Ocular/fisiologia , Hexafluoreto de Enxofre/administração & dosagem , Acuidade Visual/fisiologia
15.
Expert Opin Drug Saf ; 6(1): 27-32, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17181449

RESUMO

Mitomycin C is a chemotherapeutic agent that acts by inhibiting DNA synthesis. Its use and application in ophthalmology has been increasing in recent years because of its modulatory effects on wound healing. Current applications include pterygium surgery, glaucoma surgery, corneal refractive surgery, cicatricial eye disease, conjunctival neoplasia and allergic eye disease. Although it has been used successfully in these conditions, it has also been associated with significant complications. This article reviews the current trends and uses of mitomycin C in the eye and its reported complications.


Assuntos
Oftalmopatias/tratamento farmacológico , Mitomicina/efeitos adversos , Oftalmologia/métodos , Oftalmopatias/induzido quimicamente , Oftalmopatias/epidemiologia , Humanos , Mitomicina/uso terapêutico
16.
Cornea ; 25(6): 748-9, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17077674

RESUMO

PURPOSE: To present a case of inadvertently retained Descemet Membrane (DM). METHODS: Case report. RESULTS: A 41-year-old male with previous history of retinal detachment surgery underwent a repeat penetrating keratoplasty; the first graft decompensated secondary to silicone oil. Postoperatively, an inadvertently retained DM was observed forming a physical barrier to the silicone oil. CONCLUSION: Retained DM is a rare complication of penetrating keratoplasty, with only a few cases reported in the literature. This membrane served a protective role from the effects of silicone oil on the donor cornea but later opacified and required surgical intervention.


Assuntos
Doenças da Córnea/etiologia , Lâmina Limitante Posterior/patologia , Ceratoplastia Penetrante/efeitos adversos , Adulto , Extração de Catarata , Sobrevivência de Enxerto , Humanos , Masculino , Reoperação , Descolamento Retiniano/cirurgia , Óleos de Silicone/administração & dosagem
18.
Clin Exp Ophthalmol ; 31(1): 40-3, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12580892

RESUMO

AIMS: To investigate the penetration of ciprofloxacin via different modes of administration into the aqueous humour using capillary zone electrophoresis and to determine its prophylactic role in ophthalmic surgery. METHODS: A prospective study was conducted of 84 patients, divided into two groups, undergoing routine cataract surgery and intraocular lens implantation. Forty patients received 750 mg ciprofloxacin orally the evening before and on the morning of surgery 12 h apart. Forty-four patients received one drop of 0.3% topical ciprofloxacin 90 and 30 min prior to surgery. At the commencement of surgery 0.1-0.2 mL of aqueous fluid was sampled from the anterior chamber and assayed for ciprofloxacin concentration using capillary-zone electrophoresis. RESULTS: The concentration of ciprofloxacin in the group receiving topical doses was less than 0.1 micro g/mL, which is well below the minimum inhibitory concentration for cipro-floxacin inhibiting 90% (MIC90) of strains of Staphylococcus epidermidis (0.4 micro g/mL). The mean concentration of ciprofloxacin in the aqueous humour of the oral group was 0.26 micro g/mL with a standard deviation of 0.12 micro g/mL (range 0.09-0.67 micro g/mL) with only 12.5% achieving levels higher than MIC90 for S. epidermidis. CONCLUSION: The topical ciprofloxacin 0.3% as given in this study achieved poor aqueous humour concentration. Oral ciprofloxacin given in this regime should not on its own be considered adequate prophylaxis in intraocular surgery. Capillary zone electrophoresis can be used as an alternative tool to the existing high-pressure liquid chromatography methods for analysing ciprofloxacin level in the aqueous humour.


Assuntos
Anti-Infecciosos/farmacocinética , Humor Aquoso/metabolismo , Ciprofloxacina/farmacocinética , Administração Oral , Administração Tópica , Idoso , Idoso de 80 Anos ou mais , Anti-Infecciosos/administração & dosagem , Antibioticoprofilaxia , Disponibilidade Biológica , Extração de Catarata , Ciprofloxacina/administração & dosagem , Eletroforese Capilar , Endoftalmite/microbiologia , Endoftalmite/prevenção & controle , Humanos , Implante de Lente Intraocular , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA