Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Bone Joint J ; 99-B(10): 1304-1312, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28963151

RESUMO

AIMS: We sought to determine whether cobalt-chromium alloy (CoCr) femoral stem tapers (trunnions) wear more than titanium (Ti) alloy stem tapers (trunnions) when used in a large diameter (LD) metal-on-metal (MoM) hip arthroplasty system. PATIENTS AND METHODS: We performed explant analysis using validated methodology to determine the volumetric material loss at the taper surfaces of explanted LD CoCr MoM hip arthroplasties used with either a Ti alloy (n = 28) or CoCr femoral stem (n = 21). Only 12/14 taper constructs with a rough male taper surface and a nominal included angle close to 5.666° were included. Multiple regression modelling was undertaken using taper angle, taper roughness, bearing diameter (horizontal lever arm) as independent variables. Material loss was mapped using a coordinate measuring machine, profilometry and scanning electron microscopy. RESULTS: After adjustment for other factors, CoCr stem tapers were found to have significantly greater volumetric material loss than the equivalent Ti stem tapers. CONCLUSION: When taper junction damage is identified during revision of a LD MoM hip, it should be suspected that a male taper composed of a standard CoCr alloy has sustained significant changes to the taper cone geometry which are likely to be more extensive than those affecting a Ti alloy stem. Cite this article: Bone Joint J 2017;99-B:1304-12.


Assuntos
Artroplastia de Quadril/métodos , Ligas de Cromo , Prótese de Quadril , Próteses Articulares Metal-Metal , Adulto , Idoso , Idoso de 80 Anos ou mais , Corrosão , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Estresse Mecânico , Propriedades de Superfície
2.
Scott Med J ; 60(1): 13-22, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25428942

RESUMO

BACKGROUND AND AIMS: Femoroacetabular impingement is the abnormal contact of the proximal femur and acetabulum during motion. It causes hip pain and joint degeneration in young patients. This systematic review aims to clarify the clinical effect of arthroscopic femoral osteochondroplasty for cam lesions and to review the available literature for the general medical readership, including providers of primary and secondary care. METHODS AND RESULTS: Electronic databases were searched for studies of arthroscopic femoral osteochondroplasty in primary femoroacetabular impingement. A total of 2618 article titles, 242 abstracts and 33 full text articles were considered. Ultimately nine studies with clinical outcome scores met the inclusion criteria and were included in the qualitative systematic review. Six studies were suitable for meta-analysis using an inverse variance, random effects model (RevMan software). In the nine studies, improvements were seen in Western Ontario and McMaster Universities Osteoarthritis index, Non-arthritic Hip Score and Modified Harris Hip Scores. Across the six studies suitable for meta-analysis (537 patients), a 24-point weighted mean improvement in Non-arthritic hip score was seen. This yielded a large overall effect size of 1.6. CONCLUSION: Arthroscopic femoral osteochondroplasty appears to be a beneficial treatment for primary femoroacetabular impingement, with a large effect size seen across six eligible studies.


Assuntos
Artroscopia , Impacto Femoroacetabular/cirurgia , Fêmur/patologia , Articulação do Quadril/patologia , Artroscopia/métodos , Impacto Femoroacetabular/complicações , Impacto Femoroacetabular/patologia , Impacto Femoroacetabular/fisiopatologia , Humanos , Dor/etiologia , Medição da Dor , Resultado do Tratamento
3.
Bone Joint Res ; 3(3): 60-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24627327

RESUMO

OBJECTIVES: Wear debris released from bearing surfaces has been shown to provoke negative immune responses in the recipient. Excessive wear has been linked to early failure of prostheses. Analysis using coordinate measuring machines (CMMs) can provide estimates of total volumetric material loss of explanted prostheses and can help to understand device failure. The accuracy of volumetric testing has been debated, with some investigators stating that only protocols involving hundreds of thousands of measurement points are sufficient. We looked to examine this assumption and to apply the findings to the clinical arena. METHODS: We examined the effects on the calculated material loss from a ceramic femoral head when different CMM scanning parameters were used. Calculated wear volumes were compared with gold standard gravimetric tests in a blinded study. RESULTS: Various scanning parameters including point pitch, maximum point to point distance, the number of scanning contours or the total number of points had no clinically relevant effect on volumetric wear calculations. Gravimetric testing showed that material loss can be calculated to provide clinically relevant degrees of accuracy. CONCLUSIONS: Prosthetic surfaces can be analysed accurately and rapidly with currently available technologies. Given these results, we believe that routine analysis of explanted hip components would be a feasible and logical extension to National Joint Registries. Cite this article: Bone Joint Res 2014;3:60-8.