Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Eur J Trauma Emerg Surg ; 50(1): 37-47, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38261077

RESUMO

PURPOSE: There is a debate whether corrective osteotomies of the distal radius should be performed using a 3D work-up with pre-contoured conventional implants (i.e., of-the-shelf) or patient-specific implants (i.e., custom-made). This study aims to assess the postoperative accuracy of 3D-assisted correction osteotomy of the distal radius using either implant. METHODS: Twenty corrective osteotomies of the distal radius were planned using 3D technologies and performed on Thiel embalmed human cadavers. Our workflow consisted of virtual surgical planning and 3D printed guides for osteotomy and repositioning. Subsequently, left radii were fixated with patient-specific implants, and right radii were fixated with pre-contoured conventional implants. The accuracy of the corrections was assessed through measurement of rotation, dorsal and radial angulation and translations with postoperative CT scans in comparison to their preoperative virtual plan. RESULTS: Twenty corrective osteotomies were executed according to their plan. The median differences between the preoperative plan and postoperative results were 2.6° (IQR: 1.6-3.9°) for rotation, 1.4° (IQR: 0.6-2.9°) for dorsal angulation, 4.7° (IQR: 2.9-5.7°) for radial angulation, and 2.4 mm (IQR: 1.3-2.9 mm) for translation of the distal radius, thus sufficient for application in clinical practice. There was no significant difference in accuracy of correction when comparing pre-contoured conventional implants with patient-specific implants. CONCLUSION: 3D-assisted corrective osteotomy of the distal radius with either pre-contoured conventional implants or patient-specific implants results in accurate corrections. The choice of implant type should not solely depend on accuracy of the correction, but also be based on other considerations like the availability of resources and the preoperative assessment of implant fitting.


Assuntos
Fraturas Mal-Unidas , Fraturas do Rádio , Cirurgia Assistida por Computador , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Cirurgia Assistida por Computador/métodos , Fraturas Mal-Unidas/cirurgia , Osteotomia/métodos
2.
Eur J Trauma Emerg Surg ; 50(1): 11-19, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37391531

RESUMO

PURPOSE: A substantial proportion of conventional tibial plateau plates have a poor fit, which may result in suboptimal fracture reduction due to applied -uncontrolled- compression on the bone. This study aimed to assess whether patient-specific osteosyntheses could facilitate proper fracture reduction in medial tibial plateau fractures. METHODS: In three Thiel embalmed human cadavers, a total of six tibial plateau fractures (three Schatzker 4, and three Schatzker 6) were created and CT scans were made. A 3D surgical plan was created and a patient-specific implant was designed and fabricated for each fracture. Drilling guides that fitted on top of the customized plates were designed and 3D printed in order to assist the surgeon in positioning the plate and steering the screws in the preplanned direction. After surgery, a postoperative CT scan was obtained and outcome was compared with the preoperative planning in terms of articular reduction, plate positioning, and screw direction. RESULTS: A total of six patient-specific implants including 41 screws were used to operate six tibial plateau fractures. Three fractures were treated with single plating, and three fractures with dual plating. The median intra-articular gap was reduced from 6.0 (IQR 4.5-9.5) to 0.9 mm (IQR 0.2-1.4), whereas the median step-off was reduced from 4.8 (IQR 4.1-5.3) to 1.3 mm (IQR 0.9-1.5). The median Euclidean distance between the centre of gravity of the planned and actual implant was 3.0 mm (IQR: 2.8-3.7). The lengths of the screws were according to the predetermined plan. None of the screws led to screw penetration. The median difference between the planned and actual screw direction was 3.3° (IQR: 2.5-5.1). CONCLUSION: This feasibility study described the development and implementation of a patient-specific workflow for medial tibial plateau fracture surgery that facilitates proper fracture reduction, tibial alignment and accurately placed screws by using custom-made osteosynthesis plates with drilling guides.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Humanos , Fixação Interna de Fraturas , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Parafusos Ósseos , Placas Ósseas , Impressão Tridimensional
3.
J Hand Surg Eur Vol ; : 17531934231201962, 2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37747738

RESUMO

We performed a systematic review to compare conventional (2-D) versus 3-D-guided corrective osteotomies regarding intraoperative results, patient-reported outcome measures, range of motion, incidence of complications and pain score. PubMed (MEDLINE), Embase and Cochrane CENTRAL were searched, and 53 articles were included, reporting 1257 patients undergoing forearm corrective osteotomies between 2010 and 2022. 3-D-guided surgery resulted in a greater improvement in median Disabilities of the Arm, Shoulder and Hand (DASH) score (28, SD 7 vs. 35, SD 5) and fewer complications (12% vs. 6%). Pain scores and range of motion were similar between 3-D-guided and conventional surgery. 3-D-guided corrective osteotomy surgery appears to improve patient-reported outcomes and reduce complications compared to conventional methods. However, due to the limited number of comparative studies and the heterogeneity of the studies, a large randomized controlled trial is needed to draw definitive conclusions.Level of evidence: III.

4.
J Clin Med ; 12(18)2023 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-37762994

RESUMO

BACKGROUND: Conventional measures of fracture displacement have low interobserver reliability. This study introduced a novel 3D method to measure tibial plateau fracture displacement and its impact on functional outcome. METHODS: A multicentre study was conducted on patients who had tibial plateau fracture surgery between 2003 and 2018. Eligible patients had a preoperative CT scan (slice thickness ≤ 1 mm) and received a Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaire. A total of 362 patients responded (57%), and assessment of initial and residual fracture displacement was performed via measurement using the 3D gap area (mm2). Patients were divided into four groups based on the 3D gap area size. Differences in functional outcome between these groups were assessed using analysis of variance (ANOVA). Multiple linear regression was used to determine the association between fracture displacement and patient-reported outcome. RESULTS: Functional outcome appeared significantly worse when initial or residual fracture displacement increased. Multivariate linear regression showed that initial 3D gap area (per 100 mm2) was significantly negatively associated with all KOOS subscales: symptoms (-0.9, p < 0.001), pain (-0.0, p < 0.001), ADL (-0.8, p = 0.002), sport (-1.4, p < 0.001), and QoL (-1.1, p < 0.001). In addition, residual gap area was significantly negatively associated with the subscales symptoms (-2.2, p = 0.011), ADL (-2.2, p = 0.014), sport (-2.6, p = 0.033), and QoL (-2.4, p = 0.023). CONCLUSION: A novel 3D measurement method was applied to quantify initial and residual displacement. This is the first study which can reliably classify the degree of displacement and indicates that increasing displacement results in poorer patient-reported functional outcomes.

5.
Diagnostics (Basel) ; 13(9)2023 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-37175020

RESUMO

Displacement of the anterior and posterior column complicates decision making for both-column acetabular fractures. We questioned whether pelvic surgeons agree on treatment strategy, and whether the use of virtual 3D reconstructions changes the treatment strategy of choice. A nationwide cross-sectional survey was performed in all pelvic trauma centers in the Netherlands. Twenty surgeons assessed 15 both-column fractures in 2D as well as 3D. Based on conventional imaging, surgical treatment was recommended in 89% of cases, and by adding 3D reconstructions this was 93% (p = 0.09). Surgical approach was recommended as anterior (65%), posterior (8%) or combined (27%) (poor level of agreement, κ = 0.05) based on conventional imaging. The approach changed in 37% (p = 0.006), with most changes between a combined and anterior approach (still poor level of agreement, κ = 0.13) by adding 3D reconstructions. Additionally, surgeons' level of confidence increased from good in 38% to good in 50% of cases. In conclusion, surgeons do not agree on the treatment strategy for both-column acetabular fractures. Additional information given by 3D reconstructions may change the chosen surgical approach and increase surgeons' confidence about their treatment decision. Therefore, virtual 3D reconstructions are helpful for assessing both-column fracture patterns and aid in the choice of treatment strategy.

6.
Eur J Trauma Emerg Surg ; 49(2): 867-874, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36264307

RESUMO

PURPOSE: Currently used classification systems and measurement methods are insufficient to assess fracture displacement. In this study, a novel 3D measure for fracture displacement is introduced and associated with risk on conversion to total knee arthroplasty (TKA). METHODS: A multicenter cross-sectional study was performed including 997 patients treated for a tibial plateau fracture between 2003 and 2018. All patients were contacted for follow-up and 534 (54%) responded. For all patients, the 3D gap area was determined in order to quantify the degree of initial fracture displacement. A cut-off value was determined using ROC curves. Multivariate analysis was performed to assess the association of 3D gap area with conversion to TKA. Subgroups with increasing levels of 3D gap area were identified, and Kaplan-Meier survival curves were plotted to assess survivorship of the knee free from conversion to TKA. RESULTS: A total of 58 (11%) patients underwent conversation to TKA. An initial 3D gap area ≥ 550 mm2 was independently associated with conversion to TKA (HR 8.4; p = 0.001). Four prognostic groups with different ranges of the 3D gap area were identified: excellent (0-150 mm2), good (151-550 mm2), moderate (551-1000 mm2), and poor (> 1000 mm2). Native knee survival at 10-years follow-up was 96%, 95%, 76%, and 59%, respectively, in the excellent, good, moderate, and poor group. CONCLUSION: A novel 3D measurement method was developed to quantify initial fracture displacement of tibial plateau fractures. 3D fracture assessment adds to current classification methods, identifies patients at risk for conversion to TKA at follow-up, and could be used for patient counselling about prognosis. LEVEL OF EVIDENCE: Prognostic Level III.


Assuntos
Artroplastia do Joelho , Fraturas da Tíbia , Fraturas do Planalto Tibial , Humanos , Seguimentos , Estudos Transversais , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Resultado do Tratamento
7.
J Pers Med ; 12(9)2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36143242

RESUMO

Background: Corrective osteotomy surgery for long bone anomalies can be very challenging since deformation of the bone is often present in three dimensions. We developed a two-step approach for 3D-planned corrective osteotomies which consists of a cutting and reposition guide in combination with a conventional osteosynthesis plate. This study aimed to assess accuracy of the achieved corrections using this two-step technique. Methods: All patients (≥12 years) treated for post-traumatic malunion with a two-step 3D-planned corrective osteotomy within our center in 2021 were prospectively included. Three-dimensional virtual models of the planned outcome and the clinically achieved outcome were obtained and aligned. Postoperative evaluation of the accuracy of performed corrections was assessed by measuring the preoperative and postoperative alignment error in terms of angulation, rotation and translation. Results: A total of 10 patients were included. All corrective osteotomies were performed according to the predetermined surgical plan without any complications. The preoperative deformities ranged from 7.1 to 27.5° in terms of angulation and 5.3 to 26.1° in terms of rotation. The achieved alignment deviated on average 2.1 ± 1.0 and 3.4 ± 1.6 degrees from the planning for the angulation and rotation, respectively. Conclusions: A two-step approach for 3D-guided patient-specific corrective limb osteotomies is reliable, feasible and accurate.

8.
J Pers Med ; 12(9)2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36143248

RESUMO

This study aims to develop a three-dimensional (3D) measurement for acetabular fracture displacement, determine the inter- and intra-observer variability, and correlate the measurement with clinical outcome. Three-dimensional models were created for 100 patients surgically treated for acetabular fractures. The '3D gap area', the 3D surface between all the fracture fragments, was developed. The association between the 3D gap area and the risk of conversion to a total hip arthroplasty (THA) was determined by an ROC curve and a Cox regression analysis. The 3D gap area had an excellent inter-observer and intra-observer reliability. The preoperative median 3D gap area for patients without and with a THA was 1731 mm2 versus 2237 mm2. The median postoperative 3D gap area was 640 mm2 versus 845 mm2. The area under the curve was 0.63. The Cox regression analysis showed that a preoperative 3D gap area > 2103 mm2 and a postoperative 3D gap area > 1058 mm2 were independently associated with a 3.0 versus 2.4 times higher risk of conversion to a THA. A 3D assessment of acetabular fractures is feasible, reproducible, and correlates with clinical outcome. Three-dimensional measurements could be added to the current classification systems to quantify the level of fracture displacement and to assess operative results.

9.
PLoS One ; 17(9): e0275206, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36166437

RESUMO

INTRODUCTION: Gap and step-off measurements are generally used in the surgical decision-making process of distal radius fractures. Unfortunately, there is no consensus on treatment choice as these measurements are prone to inter- and intraobserver variability. In this study, we aim to introduce a new 3D fracture quantification method and compare it to conventional fracture analysis. METHODS: Forty patients with a minimally displaced intra-articular distal radius fracture that was treated nonoperatively between 2008-2015 were included. 2D-CT images were reassessed by three orthopedic trauma surgeons who performed gap and step-off measurements. Subsequently, 3D models were created and a 3D measurement method for fracture displacement was developed. For each fracture, the '3D gap area' (3D surface between all fracture fragments) was determined by three observers. Interobserver agreements were calculated for all measurements, and the intraobserver agreement was calculated for the new 3D measurement. All patients completed two questionnaires in order to link our measurements to functional outcome. RESULTS: The interobserver agreement of the 2D measurements was fair (ICC = 0.54) for the gap and poor (ICC = 0.21) for the step-off. The median gap was 2.8 (IQR: 1.9-3.5) mm and step-off was 0.9 (IQR: 0.0-1.6) mm. Interobserver agreement on 3D gap area measurements was excellent (ICC = 0.81), with a median difference between measurements of 6.0 (IQR: 2.0-19.0) mm2, which indicates reliable assessment of 3D fracture displacement. Intraobserver agreement was also excellent (ICC = 0.98), with a median difference of 4.0 (IQR: 1.5-5.5) mm2. No significant differences in clinical outcome were found between the above and below 2mm displacement groups. The score of the DASH was 3.4 (IQR: 0.4-8.8) versus 4.2 (IQR: 0.0-11.6) respectively. Results from the PRWE questionnaire shows a similar result of 3.5 (IQR: 0.0-12.6) versus 5.0 (IQR: 0.0-25.5). CONCLUSION: 3D gap area is a more objective measurement method compared to the conventional gap and step-off measurements to quantify the level of fracture displacement of distal radius fractures. 3D fracture assessment can be used in addition to the currently used classification systems of distal radius fractures.


Assuntos
Cirurgiões Ortopédicos , Fraturas do Rádio , Humanos , Variações Dependentes do Observador , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
10.
J Pers Med ; 12(8)2022 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-36013174

RESUMO

As 2D quantitative measurements are often insufficient, a standardized 3D quantitative measurement method was developed to analyze mandibular condylar fractures, and correlate the results with the mandibular condylar fracture classifications of Loukota and Spiessl and Schroll and clinical parameters. Thirty-two patients with a unilateral mandibular condylar fracture were evaluated using OPT, 2D (CB)CT images, and 3D imaging to measure the extent of the fractures. The maximum mouth opening (MMO) was measured. Ramus height loss could be measured only in OPT, but not in 2D CT images. The Intraclass Correlation Coefficient was excellent in the 3D measurements. In the Loukota classification, condylar neck fractures had the largest median 3D displacement and the highest rotations of the fracture fragments. The largest fracture volume was observed in base fractures. According to the Spiessl and Schroll classification, type V fractures had the largest median 3D displacement and the highest rotation in the X-axis and Z-axis. Type I fractures had the largest fracture volume. We found a moderate negative correlation between MMO and 3D displacement and rotation on Z-axis. The 2D quantitative analysis of condylar fractures is limited, imprecise, and not reproducible, while quantitative 3D measurements provide extensive, precise, objective, and reproducible information.

11.
Eur J Trauma Emerg Surg ; 48(4): 2849-2857, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35254459

RESUMO

PURPOSE: Pelvic ring injuries are known to affect the patients' daily life in terms of physical functioning and quality of life (QoL). Still, prospective studies on the patient's perception over the first 2 years of rehabilitation are lacking. Therefore, patients cannot be properly informed about whether or when they will return to their pre-existing level of physical functioning and QoL. METHODS: A prospective longitudinal cohort study was performed over a 4-year period including all consecutive patients above 18 years who sustained a pelvic ring injury in a level 1 trauma center. Validated patient-reported outcome measures (PROMs) were used to assess physical functioning (SMFA) and QoL (EQ-5D) at baseline (recalled pre-injury score), 6 weeks, 3 months, 6 months, 1 year and 2 years after the injury. It was assessed whether patients had fully recovered by comparing follow-up scores to baseline PROMs. Binary logistic regression analysis was used to identify independent predictors for patients who did not fully recover. Most experienced difficulties at 3 months and 1 year were identified by analyzing the highest reported scores on individual items of the SMFA. RESULTS: A total of 297 patients with a pelvic ring injury were identified of which 189 were eligible for follow-up and 154 (82%) responded. Median SMFA function score at 3 months, 1 and 2 years was 70, 78 and 88, respectively, compared to 96 out of 100 before the injury. Median SMFA bother score was 67, 79 and 88, respectively. Median EQ-5D score at 3 months, 1 and 2 years was 0.61, 0.81 and 0.85, respectively, compared to 1 (maximum achievable) before the injury. After 1 and 2 years of follow-up, 61% and 75% of the patients fully "recovered" in physical functioning and 52% and 71% fully recovered in terms of QoL. Female gender and high-energy trauma were independent predictors for not fully recovering after 1 year. After 3 months of follow-up, 54% of patients reported severe difficulties with recreational activities, whereas after 1 year, most experienced difficulties (31% of patients) concerned heavy house or yard work. Moreover, after 3 months and 1 year, 44% and 27% of patients reported feeling physically disabled. CONCLUSION: Pelvic ring injuries have a large impact on the patients' daily life in the first 2 years of rehabilitation. Directly after the injury, physical functioning and QoL decrease strongly but then gradually improve over a 2-year period with about 75% of patients fully recovering. Female gender and high-energy trauma are shown to be independent predictors for not fully recovering. After 3 months, patients experience difficulties with both the physical and mental effects of the injury which continue to be present after 1 year.


Assuntos
Ossos Pélvicos , Qualidade de Vida , Feminino , Humanos , Estudos Longitudinais , Saúde Mental , Ossos Pélvicos/lesões , Estudos Prospectivos
12.
J Pers Med ; 11(10)2021 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-34683107

RESUMO

Three-dimensional technology is increasingly being used in acetabular fracture treatment. No systematic reviews are available about the added clinical value of 3D-assisted acetabular fracture surgery compared to conventional surgery. Therefore, this study aimed to investigate whether 3D-assisted acetabular fracture surgery compared to conventional surgery improves surgical outcomes in terms of operation time, intraoperative blood loss, intraoperative fluoroscopy usage, complications, and postoperative fracture reduction, and whether it improves physical functioning. Pubmed and Embase databases were searched for articles on 3D technologies in acetabular fracture surgery, published between 2010 and February 2021. The McMaster critical review form was used to assess the methodological quality. Differences between 3D-assisted and conventional surgery were evaluated using the weighted mean and odds ratios. Nineteen studies were included. Three-dimensional-assisted surgery resulted in significantly shorter operation times (162.5 ± 79.0 versus 296.4 ± 56.0 min), less blood loss (697.9 ± 235.7 mL versus 1097.2 ± 415.5 mL), and less fluoroscopy usage (9.3 ± 5.9 versus 22.5 ± 20.4 times). The odds ratios of complications and fracture reduction were 0.5 and 0.4 for functional outcome in favour of 3D-assisted surgery, respectively. Three-dimensional-assisted surgery reduces operation time, intraoperative blood loss, fluoroscopy usage, and complications. Evidence for the improvement of fracture reduction and functional outcomes is limited.

13.
J Pers Med ; 11(9)2021 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-34575708

RESUMO

Background: There has been an exponential growth in the use of advanced technologies for three-dimensional (3D) virtual pre- and intra-operative planning of pelvic ring injury surgery but potential benefits remain unclear. The purpose of this study was to evaluate differences in intra- and post-operative results between 3D and conventional (2D) surgery. Methods: A systematic review was performed including published studies between 1 January 2010 and 22 May 2020 on all available 3D techniques in pelvic ring injury surgery. Studies were assessed for their methodological quality according to the Modified McMaster Critical Review form. Differences in operation time, blood loss, fluoroscopy time, screw malposition rate, fracture reduction and functional outcome between 3D-assisted and conventional (2D) pelvic injury treatment were evaluated and a best-evidence synthesis was performed. Results: Eighteen studies fulfilled the inclusion criteria, evaluating a total of 988 patients. Overall quality was moderate. Regarding intra-operative results of 3D-assisted versus conventional surgery: The weighted mean operation time per screw was 43 min versus 52 min; for overall operation time 126 min versus 141 min; blood loss 275 ± 197 mL versus 549 ± 404 mL; fluoroscopy time 74 s versus 125 s and fluoroscopy frequency 29 ± 4 versus 63 ± 3. In terms of post-operative outcomes of 3D-assisted versus conventional surgery: weighted mean screw malposition rate was 8% versus 18%; quality of fracture reduction measured by the total excellent/good rate by Matta was 86% versus 82% and Majeed excellent/good rate 88% versus 83%. Conclusion: The 3D-assisted surgery technologies seem to have a positive effect on operation time, blood loss, fluoroscopy dose, time and frequency as well as accuracy of screw placement. No improvement in clinical outcome in terms of fracture reduction and functional outcome has been established so far. Due to a wide range of methodological quality and heterogeneity between the included studies, results should be interpreted with caution.

14.
J Pers Med ; 11(8)2021 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-34442407

RESUMO

Due to the complex anatomical shape of the pelvis, screw placement can be challenging in acetabular fracture surgery. This study aims to assess the accuracy of screw placement using patient-specific surgical drilling guides applied to pre-contoured conventional implants in acetabular fracture surgery. CT scans were made of four human cadavers to create 3D models of each (unfractured) pelvis. Implants were pre-contoured on 3D printed pelvic models and optically scanned. Following virtual preoperative planning, surgical drilling guides were designed to fit on top of the implant and were 3D printed. The differences between the pre-planned and actual screw directions (degrees) and screw entry points (mm) were assessed from the pre- and postoperative CT-scans. The median difference between the planned and actual screw direction was 5.9° (IQR: 4-8°) for the in-plate screws and 7.6° (IQR: 6-10°) for the infra-acetabular and column screws. The median entry point differences were 3.6 (IQR: 2-5) mm for the in-plate screws and 2.6 (IQR: 2-3) mm for the infra-acetabular and column screws. No screws penetrated into the hip joint or caused soft tissue injuries. Three-dimensional preoperative planning in combination with surgical guides that envelope pre-contoured conventional implants result in accurate screw placement during acetabular fracture surgery.

15.
Sci Rep ; 11(1): 3671, 2021 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-33574454

RESUMO

The reproducibility of scanning in the periorbital region with 3D technology to enable objective evaluations of surgical treatment in the periorbital region was assessed. Facial 3D-scans of 15 volunteers were captured at different time points with a handheld Artec Space Spider structured light scanner. Two scans were made with a one minute interval and repeated after 1 year; for both a natural head position and with the head in a fixation-device. On assessing the area between the eyelashes and eyebrows, the medians of the average deviations between the various cross-sections of the one minute interval 3D-scans ranged from 0.17 to 0.21 mm at baseline, and from 0.10 to 0.11 mm when the minute-interval scanning was repeated one year later. The systematic differences when scanning in a natural head position and fixated position were comparable. The reproducibility of the 3D processing was excellent (intraclass correlation coefficient > 0.9). The repeated scanning deviations (baseline versus one year data) were well within the accepted clinical threshold of 1 mm. Scanning with a hand-held 3D-scanning device (Artec Space Spider) is a promising tool to assess changes in the periorbital region following surgical treatment since the median deviations are well below the clinically accepted 1 mm measuring error, for both the natural head and fixated positions.


Assuntos
Face/diagnóstico por imagem , Imageamento Tridimensional , Órbita/diagnóstico por imagem , Adulto , Face/cirurgia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Órbita/patologia , Órbita/cirurgia , Cintilografia
16.
JAMA Netw Open ; 4(2): e2037519, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33599774

RESUMO

Importance: In acetabular fracture surgery, achieving an optimal reconstruction of the articular surface decreases the risk of osteoarthritis and the subsequent need for total hip arthroplasty. However, no one-size-fits-all osteosynthesis plate is available owing to differences in fracture patterns and variations in pelvic anatomy. Currently, osteosynthesis plates need to be manually contoured intraoperatively, often resulting in inadequate reduction and fixation of the fractured segments. Objective: To determine the feasibility and accuracy of a novel concept of fast-track 3-dimensional (3-D) virtual surgical planning and patient-specific osteosynthesis for complex acetabular fracture surgery. Design, Setting, and Participants: This case series study examines the use of patient-specific osteosynthesis plates for patients needing operative treatment for displaced associated-type acetabular fractures at a tertiary university-affiliated referral center and level 1 trauma center between January 1, 2017, and December 31, 2018. Models were created in 3-D based on computed tomography (CT) data, fractures were virtually reduced, and implant positions were discussed in a multidisciplinary team of clinicians and engineers. Patient-specific osteosynthesis plates with drilling guides were designed, produced, sterilized and clinically applied within 4 days. Data were analyzed at the 1-year follow-up. Exposures: Development and clinical implementation of personalized fracture surgery. Main Outcomes and Measures: The primary outcome was the quality of the reduction as determined by the postoperative CT scan. The secondary outcomes were accuracy of the screw placement and clinical outcome using patient-reported outcome measures. Results: Ten patients with a median (range) age of 63 (46-79) years with an acetabular fracture were included. The median (interquartile range [IQR]) preoperative gap was 20 (15-22) mm, and the median (IQR) step-off was 5 (3-11) mm. Postoperatively, the median (IQR) gap was reduced to 3 (2-5) mm (P = .005), and the median (IQR) step-off was reduced to 0 (0-2) mm (P = .01), indicating good fracture reduction, indicating good fracture reduction. The mean difference between the preoperative and postoperative gap was 14.6 (95% CI, 10-19) mm, and the mean difference in step-off was 5.7 (95% CI, 2-9) mm. The median (IQR) difference in screw direction between the planning and actual surgery was only 7.1° (7°-8°). All patients retained their native hip and reported good physical functioning at follow-up. Conclusions and Relevance: These findings suggest that 3-D virtual surgical planning, manufacturing, and clinical application of patient-specific osteosynthesis plates and drilling guides was feasible and yielded good clinical outcomes. Fast-track personalized surgical treatment could open a new era for the treatment of complex injuries.


Assuntos
Acetábulo/lesões , Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Acetábulo/diagnóstico por imagem , Idoso , Estudos de Viabilidade , Feminino , Fraturas Ósseas/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Masculino , Indústria Manufatureira , Pessoa de Meia-Idade , Modelos Anatômicos , Medidas de Resultados Relatados pelo Paciente , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
Clin Orthop Relat Res ; 478(12): 2801-2808, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32769535

RESUMO

BACKGROUND: Gap and stepoff values in the treatment of acetabular fractures are correlated with clinical outcomes. However, the interobserver and intraobserver variability of gap and stepoff measurements for all imaging modalities in the preoperative, intraoperative, and postoperative phase of treatment is unknown. Recently, a standardized CT-based measurement method was introduced, which provided the opportunity to assess the level of variability. QUESTIONS/PURPOSES: (1) In patients with acetabular fractures, what is the interobserver variability in the measurement of the fracture gaps and articular stepoffs determined by each observer to be the maximum one in the weightbearing dome, as measured on pre- and postoperative pelvic radiographs, intraoperative fluoroscopy, and pre- and postoperative CT scans? (2) What is the intraobserver variability in these measurements? METHODS: Sixty patients with a complete subset of pre-, intra- and postoperative high-quality images (CT slices of < 2 mm), representing a variety of fracture types with small and large gaps and/or stepoffs, were included. A total of 196 patients with nonoperative treatment (n = 117), inadequate available imaging (n = 60), skeletal immaturity (n = 16), bilateral fractures (n = 2) or a primary THA (n = 1) were excluded. The maximum gap and stepoff values in the weightbearing dome were digitally measured on pelvic radiographs and CT images by five independent observers. Observers were free to decide which gap and/or stepoff they considered the maximum and then measure these before and after surgery. The observers were two trauma surgeons with more than 5 years of experience in pelvic surgery, two trauma surgeons with less than 5 years of experience in pelvic surgery, and one surgical resident. Additionally, the final intraoperative fluoroscopy images were assessed for the presence of a gap or stepoff in the weightbearing dome. All observers used the same standardized measurement technique and each observer measured the first five patients together with the responsible researcher. For 10 randomly selected patients, all measurements were repeated by all observers, at least 2 weeks after the initial measurements. The intraclass correlation coefficient (ICC) for pelvic radiographs and CT images and the kappa value for intraoperative fluoroscopy measurements were calculated to determine the inter- and intraobserver variability. Interobserver variability was defined as the difference in the measurements between observers. Intraobserver variability was defined as the difference in repeated measurements by the same observer. RESULTS: Preoperatively, the interobserver ICC was 0.4 (gap and stepoff) on radiographs and 0.4 (gap) and 0.3 (stepoff) on CT images. The observers agreed on the indication for surgery in 40% (gap) and 30% (stepoff) on pelvic radiographs. For CT scans the observers agreed in 95% (gap) and 70% (stepoff) of images. Postoperatively, the interobserver ICC was 0.4 (gap) and 0.2 (stepoff) on radiographs. The observers agreed on whether the reduction was acceptable or not in 60% (gap) and 40% (stepoff). On CT images the ICC was 0.3 (gap) and 0.4 (stepoff). The observers agreed on whether the reduction was acceptable in 35% (gap) and 38% (stepoff). The preoperative intraobserver ICC was 0.6 (gap and stepoff) on pelvic radiographs and 0.4 (gap) and 0.6 (stepoff) for CT scans. Postoperatively, the intraobserver ICC was 0.7 (gap) and 0.1 (stepoff) on pelvic radiographs. On CT the intraobserver ICC was 0.5 (gap) and 0.3 (stepoff). There was no agreement between the observers on the presence of a gap or stepoff on intraoperative fluoroscopy images (kappa -0.1 to 0.2). CONCLUSIONS: We found an insufficient interobserver and intraobserver agreement on measuring gaps and stepoffs for supporting clinical decisions in acetabular fracture surgery. If observers cannot agree on the size of the gap and stepoff, it will be challenging to decide when to perform surgery and study the results of acetabular fracture surgery. LEVEL OF EVIDENCE: Level III, diagnostic study.


Assuntos
Acetábulo/diagnóstico por imagem , Fraturas do Quadril/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Acetábulo/lesões , Adulto , Competência Clínica , Feminino , Fluoroscopia , Fraturas do Quadril/cirurgia , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA