Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Ultramicroscopy ; 261: 113960, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38547811

RESUMO

The high resolution of a scanning tunneling microscope (STM) relies on the stability of its scan unit. In this study, we present an isolated scan unit featuring non-magnetic design and ultra-high stability, as well as bidirectional movement capability. Different types of piezoelectric motors can be incorporated into the scan unit to create a highly stable STM. The standalone structure of scan unit ensures a stable atomic imaging process by decreasing noise generated by motor. The non-magnetic design makes the scan unit work stable in high magnetic field conditions. Moreover, we have successfully constructed a novel STM based on the isolated scan unit, in which two inertial piezoelectric motors act as the coarse approach actuators. The exceptional performance of homebuilt STM is proved by the high-resolution atomic images and dI/dV spectrums on NbSe2 surface at varying temperatures, as well as the raw-data images of graphite obtained at ultra-high magnetic fields of 23 T. According to the literature research, no STM has previously reported the atomic image at extreme conditions of 2 K low temperature and 23 T ultra-high magnetic field. Additionally, we present the ultra-low drift rates between the tip and sample at varying temperatures, as well as when raising the magnetic fields from 0 T to 23 T, indicating the ultra-high stability of the STM in high magnetic field conditions. The outstanding performance of our stable STM hold great potential for investigating the materials in ultra-high magnetic fields.

2.
Rev Sci Instrum ; 95(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38546294

RESUMO

Low-temperature scanning tunneling microscopy and spectroscopy (STM/S) help to better understand the fundamental physics of condensed matter. We present an ultracompact STM within a Φ 10 piezo tube in a 20 T superconducting magnet. The carefully cut piezo tube contains the STM's coarse-positioning assembly. Loading an STM tip-sample mechanical loop into the piezo tube with special cut openings enables an ultracompact pencil-size dimension down to Φ 10 mm, in which fine-machined nonmagnetic parts are assembled to enable slide-stick motion and xyz-scanning procedures. The small size leads to a higher resonant frequency, a typical feature of a rigid STM instrument, increasing its vibration immunity. Scanning by moving the sample while keeping the tip stationary improves the stability of the tip-sample junction compared to moving the tip. Taking advantage of its high-field compatibility and rigid design, our STM captures the atomically resolved topography of highly oriented pyrolytic graphite (HOPG) at 1.5 K and in magnetic fields up to 17 T. The topography of graphene lattice and graphite is simultaneously recorded on an atomic terrace of HOPG, unveiling a modified local charge density at a surface defect. The superconducting energy gaps of layered type-II superconductors NbSe2 and PdBi2 are well resolved through dI/dV tunneling spectra at sub-2 K. Our unique STM is highly suitable for potential STM/S applications in world-class high-field facilities where the strong magnetic field can exceed 30 T.

3.
Environ Res ; 248: 118305, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38307183

RESUMO

Chlorinated polyfluorinated ether sulfonate (F-53B), a substitute of perfluorooctane sulfonic acid (PFOS), has attracted significant attention for its link to hepatotoxicity and enterotoxicity. Nevertheless, the underlying mechanisms of F-53B-induced enterohepatic toxicity remain incompletely understood. This study aimed to explore the role of F-53B exposure on enterohepatic injury based on the gut microbiota, pathological and molecular analysis in mice. Here, we exposed C57BL/6 mice to F-53B (0, 4, 40, and 400 µg/L) for 28 days. Our findings revealed a significant accumulation of F-53B in the liver, followed by small intestines, and feces. In addition, F-53B induced pathological collagen fiber deposition and lipoid degeneration, up-regulated the expression of fatty acid ß-oxidation-related genes (PPARα and PPARγ, etc), while simultaneously down-regulating pro-inflammatory genes (Nlrp3, IL-1ß, and Mcp1) in the liver. Meanwhile, F-53B induced ileal mucosal barrier damage, and an up-regulation of pro-inflammatory genes and mucosal barrier-related genes (Muc1, Muc2, Claudin1, Occludin, Mct1, and ZO-1) in the ileum. Importantly, F-53B distinctly altered gut microbiota compositions by increasing the abundance of Akkermansia and decreasing the abundance of Prevotellaceae_NK3B31_group in the feces. F-53B-altered microbiota compositions were significantly associated with genes related to fatty acid ß-oxidation, inflammation, and mucosal barrier. In summary, our results demonstrate that F-53B is capable of inducing hepatic injury, ileitis, and gut microbiota dysbiosis in mice, and the gut microbiota dysbiosis may play an important role in the F-53B-induced enterohepatic toxicity.


Assuntos
Microbioma Gastrointestinal , Ileíte , Camundongos , Animais , Disbiose , Peixe-Zebra/metabolismo , Camundongos Endogâmicos C57BL , Fígado , Ácidos Graxos/metabolismo
4.
Thorax ; 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38388490

RESUMO

BACKGROUND: There is growing interest in the joint effects of hazardous trace elements (HTEs) on lung function deficits, but the data are limited. This is a critical research gap given increased global industrialisation. METHODS: A national cross-sectional study including spirometry was performed among 2112 adults across 11 provinces in China between 2020 and 2021. A total of 27 HTEs were quantified from urine samples. Generalised linear models and quantile-based g-computation were used to explore the individual and joint effects of urinary HTEs on lung function, respectively. RESULTS: Overall, there were negative associations between forced expiratory volume in 1 s (FEV1) and urinary arsenic (As) (z-score coefficient, -0.150; 95% CI, -0.262 to -0.038 per 1 ln-unit increase), barium (Ba) (-0.148, 95% CI: -0.258 to -0.039), cadmium (Cd) (-0.132, 95% CI: -0.236 to -0.028), thallium (Tl) (-0.137, 95% CI: -0.257 to -0.018), strontium (Sr) (-0.147, 95% CI: -0.273 to -0.022) and lead (Pb) (-0.121, 95% CI: -0.219 to -0.023). Similar results were observed for forced vital capacity (FVC) with urinary As, Ba and Pb and FEV1/FVC with titanium (Ti), As, Sr, Cd, Tl and Pb. We found borderline associations between the ln-quartile of joint HTEs and decreased FEV1 (-20 mL, 95% CI: -48 to +8) and FVC (-14 mL, 95% CI: -49 to+2). Ba and Ti were assigned the largest negative weights for FEV1 and FVC within the model, respectively. CONCLUSION: Our study investigating a wide range of HTEs in a highly polluted setting suggests that higher urinary HTE concentrations are associated with lower lung function, especially for emerging Ti and Ba, which need to be monitored or regulated to improve lung health.

5.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38197772

RESUMO

Most known two-dimensional magnets exhibit a high sensitivity to air, making direct characterization of their domain textures technically challenging. Herein, we report on the construction and performance of a glovebox-assisted magnetic force microscope (MFM) operating in a cryogen-free magnet, realizing imaging of the intrinsic magnetic structure of water and oxygen-sensitive materials. It features a compact tubular probe for a 50 mm-diameter variable temperature insert installed in a 12 T cryogen-free magnet. A detachable sealing chamber can be electrically connected to the tail of the probe, and its pump port can be opened and closed by a vacuum manipulator located on the top of the probe. This sealing chamber enables sample loading and positioning in the glove box and MFM transfer to the magnet maintained in an inert gas atmosphere (in this case, argon and helium gas). The performance of the MFM is demonstrated by directly imaging the surface (using no buffer layer, such as h-BN) of very air-sensitive van der Waals magnetic material chromium triiodide (CrI3) samples at low temperatures as low as 5 K and high magnetic fields up to 11.9 T. The system's adaptability permits replacing the MFM unit with a scanning tunneling microscope unit, enabling high-resolution atomic imaging of air-sensitive surface samples.

6.
Ultramicroscopy ; 253: 113817, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37536124

RESUMO

We present a mechanism for directly positioning the tip over a micron-size sample by tracking the trajectory of the tip and tip shadow. A bilayer graphene sheet identified by Raman spectroscopy with a lateral size of 20 µm × 50 µm was transferred on the surface of shaped gold electrodes, on which it will be rapidly captured by a homebuilt scanning tunneling microscopy (STM) with the help of an optical microscope. Using the improved line-based imaging mode, atomic-resolution images featuring a hexagonal lattice structure on the bilayer graphene sheet were obtained by our positioning-capable STM. We have also observed a unique O-ring superstructure on graphene surface that caused by the collective interference near the boundaries or defects. Furthermore, we successfully captured a graphene sheet of size as small as 1.3 nm by a rapid and large-area searching operation; this is the first time that such a small graphene sheet has been observed with atomic resolution. The STM images of a micron-size graphene sheet illustrate the significant positioning ability and imaging precision of our homebuilt STM. Our results contribute to further STM studies on samples with ultra-small size.

7.
Ultramicroscopy ; 251: 113774, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37270856

RESUMO

We present the first nonmetallic scanning tunneling microscope (STM) featuring an ultra-stable tip-sample mechanical loop and capable of atomic-resolution imaging within a 12 T magnetic field that could be either perpendicular or parallel to the sample surface. This is also the first STM with an ultra-stable tip-sample mechanical loop but without a standalone scanner. The STM head is constructed only with two parts: an improved spider-drive motor and a zirconia tip holder. The motor performs both the coarse approach and atomic imaging. A supporting spring is set at the fixed end of the motor tube to decrease the tip-sample mechanical loop. The zirconia tip holder performs as the frame of the whole STM head. With the novel design, the STM head in three dimensions can be as small as 7.9 mm × 7.9 mm × 26.5 mm. The device's excellent performance is demonstrated by atomic-resolution images of graphite and NbSe2 obtained at 300 K and 2 K, as well as the high-resolution dI/dV spectrums of NbSe2 at variable temperatures. Low drift rates in the X-Y plane and Z direction further prove the imaging stability of our new STM. High-quality imaging of the Charge Density Wave (CDW) structure on a TaS2 surface shows the STM's good application capability. Continuous atomic images obtained in magnetic fields rangs from 0 T to 12 T with the direction of the magnetic field perpendicular or parallel to the sample surface show the STM's good immunity to high magnetic fields. Our results illustrate the new STM's broad application ability in extreme conditions of low temperature and high magnetic field.

8.
Ultramicroscopy ; 253: 113773, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37315346

RESUMO

Spectroscopic-imaging scanning tunnelling microscope (SI-STM) in a water-cooled magnet (WM) at low temperature has long been desirable in the condensed matter physics area since it is crucial for addressing various scientific problems, such as the behaviour of Cooper electrons crossing Hc2 in a high-temperature superconductor. Here we report on the construction and performance of the first atomically resolved cryogenic SI-STM in a WM. It operates at low temperatures of down to 1.7 K and in magnetic fields of up to 22 T (the WM's upper safety limit). The WM-SI-STM unit features a high-stiffness sapphire-based frame with the lowest eigenfrequency being 16 kHz. A slender piezoelectric scan tube (PST) is coaxially embedded in and glued to the frame. A well-polished zirconia shaft is spring-clamped onto the gold-coated inner wall of the PST to serve both the stepper and the scanner. The microscope unit as a whole is elastically suspended in a tubular sample space inside a 1K-cryostat by a two-stage internal passive vibrational reduction system, achieving a base temperature below 2 K in a static exchange gas. We demonstrate the SI-STM by imaging TaS2 at 50 K and FeSe at 1.7 K. Detecting the well-defined superconducting gap of FeSe, an iron-based superconductor, at variable magnetic fields demonstrates the device's spectroscopic imaging capability. The maximum noise intensity at the typical frequency is 3 pA per square root Hz at 22 T, which is only slightly worse than at 0 T, indicating the insensitivity of the STM to harsh conditions. In addition, our work shows the potential of SI-STMs for use in a WM and hybrid magnet with a 50 mm-bore size where high fields can be generated.

9.
Sci Total Environ ; 882: 163100, 2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37023822

RESUMO

BACKGROUND: Arsenic (As), cadmium (Cd) and copper (Cu) are hazardous for kidney function, while the effects of selenium (Se) and zinc (Zn) were unexplored for the narrow safe range of intake. Interactions exists between these multiple metal/metalloid exposures, but few studies have investigated the effects. METHODS: A cross-sectional survey was performed among 2210 adults across twelve provinces in China between 2020 and 2021. Urinary As, Cd, Cu, Se and Zn were measured using inductively coupled plasma-mass spectrometry (ICP-MS). Serum creatinine (Scr) and N-acetyl-beta-D glucosaminidases (urine NAG) were quantified in serum and urine, respectively. Kidney function was evaluated by the estimated glomerular filtration rate (eGFR). We employed logistic regression and Bayesian kernel machine regression (BKMR) models to explore the individual and joint effects of urinary metals/metalloids on the risk of impaired renal function (IRF) or chronic kidney disease (CKD), respectively. RESULTS: Association was found between As (OR = 1.24, 95 % CI: 1.03, 1.48), Cd (OR = 1.65, 95 % CI: 1.35, 2.02), Cu (OR = 1.90, 95 % CI: 1.59, 2.29), Se (OR = 1.51, 95 % CI: 1.24, 1.85) and Zn (OR = 1.33, 95 % CI: 1.09, 1.64) and the risk of CKD. Moreover, we observed association between As (OR = 1.18, 95 % CI: 1.07, 1.29), Cu (OR = 1.14, 95 % CI: 1.04, 1.25), Se (OR = 1.15, 95 % CI: 1.06, 1.26) and Zn (OR = 1.12, 95 % CI: 1.02, 1.22) and the risk of IRF. Additionally, it was found that Se exposure may strength the association of urinary As, Cd and Cu with IRF. Furthermore, it is worth noting that Se and Cu contributed greatest to the inverse association in IRF and CKD, respectively. CONCLUSION: Our findings suggested that metal/metalloid mixtures were associated with kidney dysfunction, Se and Cu were inverse factors. Additionally, interactions between them may affect the association. Further studies are needed to assess the potential risks for metal/metalloid exposures.


Assuntos
Arsênio , Metaloides , Insuficiência Renal Crônica , Selênio , Adulto , Humanos , Estudos Transversais , Cádmio , Teorema de Bayes , Metais , Arsênio/urina , Insuficiência Renal Crônica/induzido quimicamente , Insuficiência Renal Crônica/epidemiologia , Rim
10.
Micromachines (Basel) ; 14(3)2023 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-36985044

RESUMO

We present a novel homebuilt scanning tunneling microscope (STM) with atomic resolution integrated into a cryogen-free superconducting magnet system with a variable temperature insert. The STM head is designed as a nested structure of double piezoelectric tubes (PTs), which are connected coaxially through a sapphire frame whose top has a sample stage. A single shaft made of tantalum, with the STM tip on top, is held firmly by a spring strip inside the internal PT. The external PT drives the shaft to the tip-sample junction based on the SpiderDrive principle, and the internal PT completes the subsequent scanning and imaging work. The STM head is simple, compact, and easy to assemble. The excellent performance of the device was demonstrated by obtaining atomic-resolution images of graphite and low drift rates of 30.2 pm/min and 41.4 pm/min in the X-Y plane and Z direction, respectively, at 300K. In addition, we cooled the sample to 1.6 K and took atomic-resolution images of graphite and NbSe2. Finally, we performed a magnetic field sweep test from 0 T to 9 T at 70 K, obtaining distinct graphite images with atomic resolution under varying magnetic fields. These experiments show our newly developed STM's high stability, vibration resistance, and immunity to high magnetic fields.

11.
Micromachines (Basel) ; 14(2)2023 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-36837986

RESUMO

Scanning tunneling microscopy (STM) can image material surfaces with atomic resolution, making it a useful tool in the areas of physics and materials. Many materials are synthesized at micron size, especially few-layer materials. Limited by their complex structure, very few STMs are capable of directly positioning and imaging a micron-sized sample with atomic resolution. Traditional STMs are designed to study the material behavior induced by temperature variation, while the physical properties induced by magnetic fields are rarely studied. In this paper, we present the design and construction of an atomic-resolution STM that can operate in a 9 T high magnetic field. More importantly, the homebuilt STM is capable of imaging micron-sized samples. The performance of the STM is demonstrated by high-quality atomic images obtained on a graphite surface, with low drift rates in the X-Y plane and Z direction. The atomic-resolution image obtained on a 32-µm graphite flake illustrates the new STM's ability of positioning and imaging micron-sized samples. Finally, we present atomic resolution images at a magnetic field range from 0 T to 9 T. The above advantages make our STM a promising tool for investigating the quantum hall effect of micron-sized layered materials.

12.
Micromachines (Basel) ; 14(2)2023 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-36838078

RESUMO

Recently, there has been growing interest in using lightwave-driven scanning probe microscopy (LD-SPM) to break through the Abbe diffraction limit of focusing, yielding insight into various energy couplings and conversion processes and revealing the internal information of matter. We describe a compact and efficient optical cryostat designed for LD-SPM testing under magnetic fields. The exceptional multilayer radiation shielding insert (MRSI) forms an excellent temperature gradient when filled with heat conducting gas, which removes the requirement to install an optical window in the liquid helium cooling shell. This not only critically avoids the vibration and thermal drift caused by solid heat conduction but also minimizes light transmission loss. The application of gate valves and bellows allows a simpler and more effective replacement of the sample and working cell in the test cavity. ANSYS software is used for steady-state thermal analysis of the MRSI to obtain the temperature distribution and heat transfer rate, and the necessity of the flexible copper shielding strips is illustrated by the simulations. The topography and magnetic domain images of 45 nm-thick La0.67Ca0.33MnO3 thin films on NdGaO3(001) substrates under a magnetic field were obtained by a self-made lightwave-driven magnetic force microscope in this cryostat. The resolution and noise spectra during imaging reveal temperature stability and low vibration throughout the cryostat. The experience acquired during the development of this cryostat will help to establish cryostats of similar types for a variety of optic applications requiring the use of cryogenic temperatures.

13.
Ultramicroscopy ; 245: 113668, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36565650

RESUMO

We present the design and construction of a nonmetallic tip-sample mechanical loop featured Scanning Tunneling Microscope (STM) that operates in a 22 T water-cooled magnet at a low temperature of l.8 K. The STM head mainly consists of a spider-drive motor, stand-alone scanner, moveable sapphire sample holder, and sapphire frame. All parts exist in the tip-sample mechanical loop are made of sapphire to reduce the interference from high magnetic fields. Except for the necessary movement of the tip and scanner, all STM parts are stationary. More importantly, the tip-sample mechanical loop is separate from the motor after detecting the tunneling current, which helps prevent the high voltage signal interference from entering the tip-sample junction, leading to a high stable imaging. A Janis liquid helium cryostat is used to obtain a variable temperature range from 1.8 K to 300 K, and the STM head is cooled down via helium exchange gas. The STM head hangs at the bottom of a probe with a two-stage spring suspension to prevent the huge vibration generated by the water-cooled magnet from entering the tip-sample junction. The performance is demonstrated by atomically resolved STM images of graphite surface at 0 T and 22.8 T under room temperature. Furthermore, the obtained atomic-resolution images of NbSe2 at 1.8 K and 22 T, as well as high-resolution dI/dV spectrums at temperatures from 1.8 K to 8.5 K and magnetic fields from 0 T to 22 T are displayed. This is the first STM capable of atomic-resolution imaging and dI/dV measurement at 1.8 K in a 22 T water-cooled magnet. The high immunity to the magnetic field makes the nonmetallic tip-sample mechanical loop widely useable for atomic-resolution STM imaging in ultra-high magnetic field conditions.

14.
Micromachines (Basel) ; 13(11)2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36363942

RESUMO

Magnetic Force Microscopy (MFM) is among the best techniques for examining and assessing local magnetic characteristics in surface structures at scales and sizes. It may be viewed as a unique way to operate atomic force microscopy with a ferromagnetic tip. The enhancement of magnetic signal resolution, the utilization of external fields during measurement, and quantitative data analysis are now the main areas of MFM development. We describe a new structure of MFM design based on a cryogen-free superconducting magnet. The piezoelectric tube (PZT) was implemented with a tip-sample coarse approach called SpiderDrive. The technique uses a magnetic tip on the free end of a piezo-resistive cantilever which oscillates at its resonant frequency. We obtained a high-quality image structure of the magnetic domain of commercial videotape under extreme conditions at 5 K, and a high magnetic field up to 11 T. When such a magnetic field was gradually increased, the domain structure of the videotape did not change much, allowing us to maintain the images in the specific regions to exhibit the performance. In addition, it enabled us to locate the sample region in the order of several hundred nanometers. This system has an extensive range of applications in the exploration of anisotropic magnetic phenomena in topological materials and superconductors.

15.
Rev Sci Instrum ; 93(9): 093706, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182484

RESUMO

We constructed a piezoelectric rotatable magnetic force microscope (MFM) that works in a 10 T cryogen-free superconducting magnet. The piezoelectric tube is deformed tangentially and drives a bearing under the inertial drive principle so the MFM head can obtain rotary movement. Due to the novel piezoelectric design, the MFM can be hung underneath the heat sink via a soft spring, and it can be rotated in a cryogen-free superconducting magnet so that the direction of the magnetic field can be changed from 0° to 90° continuously. The system functions in magnetic fields of up to 10 T in any direction relative to the tip-sample geometry. This is the first piezoelectric rotatable MFM ever reported. Using this homemade rotatable MFM, we imaged the structure of magnetic tracks on a commercial videotape. When the magnetic field angle changes from 0° to 90°, the magnetic moments on the tape and probe tip also rotate. A magnetic field strength of 0.8 T parallel to the sample surface is required to fully rotate the magnetic moment of the tip we used, but 0.8 T is not enough to fully rotate the magnetic moment of the sample. The piezoelectric rotatable MFM is expected to be widely used to study the anisotropy of magnetic materials due to its superiority in obtaining the same high field in and out of plane (compared with a vector magnet) as well as in maintaining the same scan area precisely (compared with a mechanical rotatable MFM, especially for atomic-scale scan areas).

16.
Environ Res ; 214(Pt 1): 113803, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35810818

RESUMO

Studies have investigated associations between maternal exposure to PFAS and preterm birth, but the impact of paternal and overall family exposure to PFAS mixtures on preterm birth remains unknown. To address this knowledge gap, a total of 355 preterm births and 481 controls were selected for a family-based birth cohort study in a coastal area of China, between 2016 and 2018. Seven PFAS, including perfluorobutanoic acid (PFBA), perfluorohexanoic acid (PFHxA), perfluorohexanesulfonic acid (PFHxS), perfluorooctanoic acid (PFOA), perfluorooctanesulfonic acid (PFOS), perfluorononanoic acid (PFNA) and perfluorodecanoic acid (PFDA), were quantified in maternal, paternal and neonatal sera. Preterm birth was defined as live delivery at <37 completed gestational weeks. Bayesian kernel machine regression (BKMR) model was used to inspect the combined effect of family PFAS mixtures. Latent class analysis was used to identify family-level PFAS exposure profiles. Multiple linear regression analysis showed higher odds of preterm birth in association with higher maternal PFBA (OR = 1.16, 95%CI:1.09, 1.25), PFOA (OR = 1.51, 95%CI:1.27, 1.80), PFOS (OR = 2.07, 95%CI:1.70, 2.52) and PFNA (OR = 1.36, 95%CI: 1.01, 1.83), and neonatal PFBA (OR = 1.16, 95%CI:1.05,1.29), PFHxA (OR = 1.46, 95%CI:1.32, 1.62), PFHxS (OR = 1.15, 95%CI:1.05, 1.26) and PFNA (OR = 1.30, 95%CI:1.09,1.56). The associations were reversed between individual paternal PFAS exposures and preterm birth. At the family level, higher PFAS mixture concentration was associated with higher odds of preterm birth. In particular, higher PFNA and PFDA exposure was associated with greater preterm birth risk (OR = 2.55, 95%CI:1.45, 4.50). The PFAS-preterm association was modified by family-level seafood consumption. Our results suggest that higher family-level PFNA and PFDA exposure was associated with greater preterm birth risk, although the results for individual paternal, maternal and neonatal PFAS exposures were contradictory. If replicated in other coastal areas, these findings highlight a need to focus on the family triad and to consider seafood consumption when assessing the reproductive toxicity of PFAS exposure.


Assuntos
Ácidos Alcanossulfônicos , Poluentes Ambientais , Fluorocarbonos , Nascimento Prematuro , Efeitos Tardios da Exposição Pré-Natal , Teorema de Bayes , Coorte de Nascimento , Estudos de Coortes , Feminino , Humanos , Recém-Nascido , Gravidez
17.
Rev Sci Instrum ; 93(4): 043710, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35489922

RESUMO

We present a two-degree-of-freedom piezoelectric motor, which is driven by a simple cross-shaped piezo unit. Here, not only the structure of high novelty and simplicity but also the working principle is new. The cross-shaped piezo unit is sandwiched between top and bottom guiding plates with roughly equal pressing forces applied between the four free ends of the piezo unit and the plates. The working principle is as follows: A pair of opposite arms of the piezo unit quickly and simultaneously expand and contract periodically in the X direction, which results in a vanishing total friction force in the X direction; meanwhile, the other two arms in the Y direction deform slowly in a push-pull manner, which will move the aforementioned X-direction arms a step in the Y direction; then, the Y direction piezo arms restore their initial states slowly one by one. Repeating these actions will produce continuous stepping in the Y direction. Because the structure is symmetric in X and Y directions, we can similarly produce stepping in the X direction. The advantages are obvious: compact, rigid, and planar, which are all important for high stability and, hence, crucial in building an atomically resolved scanning probe microscope.

18.
Int J Biol Macromol ; 169: 473-479, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33358779

RESUMO

Fibroin of the silkworm consists of fibroin heavy chain (Fib-H) with hydrophobic intermediate repeats flanked by hydrophilic N and C terminal domains (NTD and CTD, respectively), fibroin light chain (Fib-L), and P25. However, the respective roles of each polypeptide in silk processing remain largely unknown. Here, a series of transgenic silkworms with different fusion gene expression cassettes were created in order to selectively express different fluorescent fusion proteins in silk glands. The roles of different components in silk processing were investigated via observing and analyzing the movement and distribution of these proteins in the silk gland and in cocoon silk. The data showed that hydrophilic NTDs were distributed on the surface of micelles, providing sufficient electrostatic repulsion to prevent premature crystallization of silk proteins. Hydrophilic CTD==Ls ("==" represents the disulfide bond) were located on the inner layer of micelles to control the solubility of large micelles. The results presented here elucidated the underlying mechanisms of silkworm silk processing in vivo. This is significant for the development of artificial spinning technology, novel silk biomaterials, and silk gland expression systems.


Assuntos
Bombyx/metabolismo , Fibroínas/química , Fibroínas/metabolismo , Animais , Animais Geneticamente Modificados/genética , Materiais Biocompatíveis/metabolismo , Secreções Corporais/metabolismo , Bombyx/química , Fibroínas/fisiologia , Proteínas de Insetos/genética , Domínios Proteicos/fisiologia , Seda/metabolismo
19.
ACS Appl Mater Interfaces ; 12(38): 43281-43288, 2020 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-32845603

RESUMO

The evolution of anisotropic strain in epitaxial Pr0.5Sr0.5MnO3 films grown on (LaAlO3)0.3(SrAl0.5Ta0.5O3)0.7(110) substrates has been characterized by off-specular X-ray reciprocal space mappings on the (130), (310), (222), and (222̅) reflections in the scattering zone containing the [110] axis. We demonstrate that a multistage hierarchical structural evolution (single-domain-like structure, domain ordering, twin domains, and/or periodic structural modulations) occurs as the film thickness increases, and the structural modulation between the two transverse in-plane [11̅0] and [001] directions is quite different due to the monoclinic distortion of the film. We then show the relationship between the distribution of diffraction spots in reciprocal space and their corresponding domain configurations in real space under various thicknesses, which is closely correlated with thickness-dependent magnetic and magnetotransport properties. More importantly, the distribution and annihilation dynamics of the domain ordering are imaged utilizing home-built magnetic force microscope, revealing that the structural domains tilted toward either the [001] or [001̅] direction are arranged along the [11̅1] and [1̅11] crystal orientations. The direct visualization and dynamics of anisotropic-strain-related domain ordering will open a new path toward the control and manipulation of domain engineering in strongly correlated perovskite oxide films.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA