Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
PLoS One ; 19(5): e0301624, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38713678

RESUMO

Salmonella enterica serovar Typhi (S. Typhi) is the causative agent of Typhoid fever. Blood culture is the gold standard for clinical diagnosis, but this is often difficult to employ in resource limited settings. Environmental surveillance of waste-impacted waters is a promising supplement to clinical surveillance, however validating methods is challenging in regions where S. Typhi concentrations are low. To evaluate existing S. Typhi environmental surveillance methods, a novel process control organism (PCO) was created as a biosafe surrogate. Using a previous described qPCR assay, a modified PCR amplicon for the staG gene was cloned into E. coli. We developed a target region that was recognized by the Typhoid primers in addition to a non-coding internal probe sequence. A multiplex qPCR reaction was developed that differentiates between the typhoid and control targets, with no cross-reactivity or inhibition of the two probes. The PCO was shown to mimic S. Typhi in lab-based experiments with concentration methods using primary wastewater: filter cartridge, recirculating Moore swabs, membrane filtration, and differential centrifugation. Across all methods, the PCO seeded at 10 CFU/mL and 100 CFU/mL was detected in 100% of replicates. The PCO is detected at similar quantification cycle (Cq) values across all methods at 10 CFU/mL (Average = 32.4, STDEV = 1.62). The PCO was also seeded into wastewater at collection sites in Vellore (India) and Blantyre (Malawi) where S. Typhi is endemic. All methods tested in both countries were positive for the seeded PCO. The PCO is an effective way to validate performance of environmental surveillance methods targeting S. Typhi in surface water.


Assuntos
Monitoramento Ambiental , Escherichia coli , Salmonella typhi , Salmonella typhi/genética , Salmonella typhi/isolamento & purificação , Escherichia coli/genética , Escherichia coli/isolamento & purificação , Monitoramento Ambiental/métodos , Águas Residuárias/microbiologia , Febre Tifoide/microbiologia , Febre Tifoide/epidemiologia , Febre Tifoide/diagnóstico , Febre Tifoide/prevenção & controle , Humanos , Microbiologia da Água
2.
PLoS Negl Trop Dis ; 18(3): e0011468, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38551999

RESUMO

Typhoid fever-an acute febrile disease caused by infection with the bacterium Salmonella enterica serotype Typhi (S. Typhi)-continues to be a leading cause of global morbidity and mortality, particularly in developing countries with limited access to safe drinking water and adequate sanitation. Environmental surveillance, the process of detecting and enumerating disease-causing agents in wastewater, is a useful tool to monitor the circulation of typhoid fever in endemic regions. The design of environmental surveillance sampling plans and the interpretation of sampling results is complicated by a high degree of uncertainty and variability in factors that affect the final measured pathogens in wastewater samples, such as pathogen travel time through a wastewater network, pathogen dilution, decay and degradation, and laboratory processing methods. Computational models can, to an extent, assist in the design of sampling plans and aid in the evaluation of how different contributing factors affect sampling results. This study presents a computational model combining dynamic and probabilistic modeling techniques to estimate-on a spatial and temporal scale-the approximate probability of detecting S. Typhi within a wastewater system. This model may be utilized to inform environmental surveillance sampling plans and may provide useful insight into selecting appropriate sampling locations and times and interpreting results. A simulated applied modeling scenario is presented to demonstrate the model's functionality for aiding an environmental surveillance study in a typhoid-endemic community.


Assuntos
Salmonella typhi , Salmonella , Febre Tifoide , Humanos , Febre Tifoide/epidemiologia , Águas Residuárias , Simulação por Computador , Monitoramento Ambiental
3.
Lancet Reg Health Southeast Asia ; 20: 100299, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38234701

RESUMO

Background: Wastewater-based surveillance is used to track the temporal patterns of the SARS-CoV-2 virus in communities. Viral RNA particle detection in wastewater samples can indicate an outbreak within a catchment area. We describe the feasibility of using a sewage network to monitor SARS-CoV-2 trend and use of genomic sequencing to describe the viral variant abundance in an urban district in Karachi, Pakistan. This was among the first studies from Pakistan to demonstrate the surveillance for SARS-CoV-2 from a semi-formal sewage system. Methods: Four sites draining into the Lyari River in District East, Karachi, were identified and included in the current study. Raw sewage samples were collected early morning twice weekly from each site between June 10, 2021 and January 17, 2022, using Bag Mediated Filtration System (BMFS). Secondary concentration of filtered samples was achieved by ultracentrifugation and skim milk flocculation. SARS-CoV-2 RNA concentrations in the samples were estimated using PCR (Qiagen ProMega kits for N1 & N2 genes). A distributed-lag negative binomial regression model within a hierarchical Bayesian framework was used to describe the relationship between wastewater RNA concentration and COVID-19 cases from the catchment area. Genomic sequencing was performed using Illumina iSeq100. Findings: Among the 151 raw sewage samples included in the study, 123 samples (81.5%) tested positive for N1 or N2 genes. The average SARS-CoV-2 RNA concentrations in the sewage samples at each lag (1-14 days prior) were associated with the cases reported for the respective days, with a peak association observed on lag day 10 (RR: 1.15; 95% Credible Interval: 1.10-1.21). Genomic sequencing showed that the delta variant dominated till September 2022, while the omicron variant was identified in November 2022. Interpretation: Wastewater-based surveillance, together with genomic sequencing provides valuable information for monitoring the community temporal trend of SARS-CoV-2. Funding: PATH, Bill & Melinda Gates Foundation, and Global Innovation Fund.

4.
J Infect Dis ; 229(4): 979-987, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37775091

RESUMO

BACKGROUND: Environmental surveillance (ES) for Salmonella Typhi potentially offers a low-cost tool to identify communities with a high burden of typhoid fever. METHODS: We developed standardized protocols for typhoid ES, including sampling site selection, validation, characterization; grab or trap sample collection, concentration; and quantitative PCR targeting Salmonella genes (ttr, staG, and tviB) and a marker of human fecal contamination (HF183). ES was implemented over 12 months in a historically high typhoid fever incidence setting (Vellore, India) and a lower incidence setting (Blantyre, Malawi) during 2021-2022. RESULTS: S. Typhi prevalence in ES samples was higher in Vellore compared with Blantyre; 39/520 (7.5%; 95% confidence interval [CI], 4.4%-12.4%) vs 11/533 (2.1%; 95% CI, 1.1%-4.0%) in grab and 79/517 (15.3%; 95% CI, 9.8%-23.0%) vs 23/594 (3.9%; 95% CI, 1.9%-7.9%) in trap samples. Detection was clustered by ES site and correlated with site catchment population in Vellore but not Blantyre. Incidence of culture-confirmed typhoid in local hospitals was low during the study and zero some months in Vellore despite S. Typhi detection in ES. CONCLUSIONS: ES describes the prevalence and distribution of S. Typhi even in the absence of typhoid cases and could inform vaccine introduction. Expanded implementation and comparison with clinical and serological surveillance will further establish its public health utility.


Assuntos
Febre Tifoide , Vacinas Tíficas-Paratíficas , Humanos , Febre Tifoide/epidemiologia , Febre Tifoide/prevenção & controle , Salmonella typhi/genética , Malaui/epidemiologia , Incidência , Índia/epidemiologia
5.
Nat Commun ; 14(1): 7883, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38036496

RESUMO

The COVID-19 pandemic has profoundly impacted health systems globally and robust surveillance has been critical for pandemic control, however not all countries can currently sustain community pathogen surveillance programs. Wastewater surveillance has proven valuable in high-income settings, but less is known about the utility of water surveillance of pathogens in low-income countries. Here we show how wastewater surveillance of SAR-CoV-2 can be used to identify temporal changes and help determine circulating variants quickly. In Malawi, a country with limited community-based COVID-19 testing capacity, we explore the utility of rivers and wastewater for SARS-CoV-2 surveillance. From May 2020-May 2022, we collect water from up to 112 river or defunct wastewater treatment plant sites, detecting SARS-CoV-2 in 8.3% of samples. Peak SARS-CoV-2 detection in water samples predate peaks in clinical cases. Sequencing of water samples identified the Beta, Delta, and Omicron variants, with Delta and Omicron detected well in advance of detection in patients. Our work highlights how wastewater can be used to detect emerging waves, identify variants of concern, and provide an early warning system in settings with no formal sewage systems.


Assuntos
COVID-19 , Águas Residuárias , Humanos , Esgotos , SARS-CoV-2 , Teste para COVID-19 , Pandemias , Rios , COVID-19/diagnóstico , COVID-19/epidemiologia , Vigilância Epidemiológica Baseada em Águas Residuárias , Água
6.
PLOS Glob Public Health ; 3(1): e0001074, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36962955

RESUMO

The typhoid conjugate vaccine is a safe and effective method for preventing Salmonella enterica serovar Typhi (typhoid) and the WHO's guidance supports its use in locations with ongoing transmission. However, many countries lack a robust clinical surveillance system, making it challenging to determine where to use the vaccine. Environmental surveillance is one alternative approach to identify ongoing transmission, but the cost to implement such a strategy is previously unknown. This paper estimated the cost of setting up and operating an environmental surveillance program for thirteen protocols that are in development, including thirteen cost components and twenty-seven pieces of equipment. Unit costs were obtained from research labs involved in protocol development and equipment information was obtained from manufacturers and the expert opinion of individuals in participating labs. We used Monte Carlo simulations to estimate the costs and the input parameters were modeled as distributions to incorporate the uncertainty. Total costs per sample including setup, overhead, and operational costs, range from $357-794 at a scale of 25 sites to $116-532 at 125 sites. Operational costs (ongoing expenditures) range from $218-584 per sample at a scale of 25 sites to $74-421 at 125 sites. Eleven of the thirteen protocols have operational costs below $200, at this higher scale. Protocols with higher up-front equipment costs benefit more from scale efficiencies and sensitivity analyses show that laboratory labor, processes, and consumables are the primary drivers of uncertainty. At scale, environmental surveillance for typhoid may be affordable (depending on the protocol, scale, and geographic context), though cost will need to be considered alongside future evaluations of test sensitivity. Opportunities to leverage existing infrastructure and multi-disease platforms may be necessary to further reduce costs.

7.
J Water Health ; 20(2): iii-vi, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-36366985

Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Água
8.
J Occup Environ Hyg ; 19(9): 524-537, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35816423

RESUMO

The emergence of COVID-19 and its corresponding public health burden has prompted industries to rapidly implement traditional and novel control strategies to mitigate the likelihood of SARS-CoV-2 transmission, generating a surge of interest and application of ultraviolet germicidal irradiation (UVGI) sources as disinfection systems. With this increased attention the need to evaluate the efficacy and safety of these types of devices is paramount. A field study of the early implementation of UVGI devices was conducted at the Space Needle located in Seattle, Washington. Six devices were evaluated, including four low-pressure (LP) mercury-vapor lamp devices for air and surface sanitation not designed for human exposure and two krypton chloride (KrCl*) excimer lamp devices to be operated on and around humans. Emission spectra and ultraviolet (UV) irradiance at different locations from the UV devices were measured and germicidal effectiveness against SARS-CoV-2 was estimated. The human safety of KrCl* excimer devices was also evaluated based on measured irradiance and estimated exposure durations. Our results show all LP devices emitted UV radiation primarily at 254 nm as expected. Both KrCl* excimers emitted far UVC irradiation at 222 nm as advertised but also emitted at longer, more hazardous wavelengths (228 to 262 nm). All LP devices emitted strong UVC irradiance, which was estimated to achieve three log reduction of SARS-CoV-2 within 10 sec of exposure at reasonable working distances. KrCl* excimers, however, emitted much lower irradiance than needed for effective disinfection of SARS-CoV-2 (>90% inactivation) within the typical exposure times. UV fluence from KrCl* excimer devices for employees was below the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values (TLVs) under the reported device usage and work shifts. However, photosensitive individuals, human susceptibility, or exposure to multiple UV sources throughout a worker's day, were not accounted for in this study. Caution should be used when determining the acceptability of UV exposure to workers in this occupational setting and future work should focus on UVGI sources in public settings.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/epidemiologia , COVID-19/prevenção & controle , Desinfecção/métodos , Humanos , Saúde Pública , Raios Ultravioleta
9.
Food Environ Virol ; 14(4): 355-363, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35143035

RESUMO

Wastewater surveillance for SARS-CoV-2 may serve as a useful source of data for public health departments as the virus is shed in the stool of infected individuals. However, for wastewater data to be actionable, wastewater must be collected, concentrated, and analyzed in a timely manner. This manuscript presents modifications on a skimmed milk concentration protocol to reduce processing time, increase the number of samples that can be processed at once, and enable use in resource-limited settings. Wastewater seeded with Human coronavirus OC43 (OC43) was concentrated using a skimmed milk flocculation protocol, and then pellets were directly extracted with the QIAamp Viral RNA Mini kit. This protocol has a higher average effective volume assayed (6.35 mL) than skimmed milk concentration methods, with and without Vertrel XF™, which involve resuspension of the pellets in PBS extraction prior to nucleic acid extraction (1.28 mL, 1.44 mL, respectively). OC43 was selected as a recovery control organism because both it and SARS-CoV-2 are enveloped respiratory viruses that primarily infect humans resulting in respiratory symptoms. The OC43 percent recovery for the direct extraction protocol (3.4%) is comparable to that of skimmed milk concentration with and without Vertrel XF™ extraction (4.0%, 2.6%, respectively). When comparing SARS-CoV-2 detection using McNemar's chi-square test, the pellet extraction method is not statistically different from skimmed milk concentration, with and without Vertrel XF™ extraction. This suggests that the method performs equally as well as existing methods. Added benefits include reduced time spent per sample and the ability to process more samples at a single time. Direct extraction of skimmed milk pellets is a viable method for quick turnaround of wastewater data for public health interventions.


Assuntos
COVID-19 , Vírus , Humanos , Animais , SARS-CoV-2 , Águas Residuárias , Leite , Vigilância Epidemiológica Baseada em Águas Residuárias , RNA Viral/genética
10.
PLoS One ; 17(1): e0262761, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35081146

RESUMO

Eradication of poliovirus (PV) is a global public health priority, and as clinical cases decrease, the role of environmental surveillance becomes more important. Persistence of PV and the environmental factors that influence it (such as temperature and sample type) are an important part of understanding and interpreting positive environmental surveillance samples. The objective of this study was to evaluate the persistence of poliovirus type 2 (PV2) and type 3 (PV3) in wastewater and sediment. Microcosms containing either 1) influent wastewater or 2) influent wastewater with a sediment matrix were seeded with either PV2 or PV3, and stored for up to 126 days at three temperatures (4°C, room temperature [RT], and 30°C). Active PV in the liquid of (1), and the sediment and liquid portions of (2) were sampled and quantified at up to 10 time points via plaque assay and RT-qPCR. A suite of 17 models were tested for best fit to characterize decay of PV2 and PV3 over time and determine the time points at which >90% (T90) and >99% (T99) reduction was reached. Linear models assessed the influence of experimental factors (matrix, temperature, virus type and method of detection) on the predicted T90 and T99 values. Results showed that when T90 was the dependent variable, virus type, matrix, and temperature significantly affected decay, and there was a clear interaction between the sediment matrix and temperature. When T99 was the dependent variable, only temperature and matrix type significantly influenced the decay metric. This study characterizes the persistence of both active and molecular PV2 and PV3 in relevant environmental conditions, and demonstrates that temperature and sediment both play important roles in PV viability. As eradication nears and clinical cases decrease, environmental surveillance and knowledge of PV persistence will play a key role in understanding the silent circulation in endemic countries.


Assuntos
Monitoramento Ambiental , Sedimentos Geológicos/virologia , Poliovirus/isolamento & purificação , Águas Residuárias/virologia
11.
ACS ES T Water ; 2(11): 1964-1975, 2022 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-37552740

RESUMO

Wastewater based epidemiology (WBE) has emerged as a tool to track the spread of SARS-CoV-2. However, sampling at wastewater treatment plants (WWTPs) cannot identify transmission hotspots within a city. Here, we sought to understand the diurnal variations (24 h) in SARS-CoV-2 RNA titers at the neighborhood level, using pump stations that serve vulnerable communities (e.g., essential workers, more diverse communities). Hourly composite samples were collected from wastewater pump stations located in (i) a residential area and (ii) a shopping district. In the residential area, SARS-CoV-2 RNA concentration (N1, N2, and E assays) varied by up to 42-fold within a 24 h period. The highest viral load was observed between 5 and 7 am, when viral RNA was not diluted by stormwater. Normalizing peak concentrations during this time window with nutrient concentrations (N and P) enabled correcting for rainfall to connect sewage to clinical cases reported in the sewershed. Data from the shopping district pump station were inconsistent, probably due to the fluctuation of customers shopping at the mall. This work indicates pump stations serving the residential area offer a narrow time period of high signal intensity that could improve the sensitivity of WBE, and tracer compounds (N, P concentration) can be used to normalize SARS-CoV-2 signals during rainfall.

12.
Viruses ; 13(3)2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33803454

RESUMO

Enteric viruses, such as poliovirus, are a leading cause of gastroenteritis, which causes 2-3 million deaths annually. Environmental surveillance of wastewater supplements clinical surveillance for monitoring enteric virus circulation. However, while many environmental surveillance methods require liquid samples, some at-risk locations utilize pit latrines with waste characterized by high solids content. This study's objective was to develop and evaluate enteric virus concentration protocols for high solids content samples. Two existing protocols were modified and tested using poliovirus type 1 (PV1) seeded into primary sludge. Method 1 (M1) utilized acid adsorption, followed by 2 or 3 elutions (glycine/sodium chloride and/or threonine/sodium chloride), and skimmed milk flocculation. Method 2 (M2) began with centrifugation. The liquid fraction was filtered through a ViroCap filter and eluted (beef extract/glycine). The solid fraction was eluted (beef extract/disodium hydrogen phosphate/citric acid) and concentrated by skimmed milk flocculation. Recovery was enumerated by plaque assay. M1 yielded higher PV1 recovery than M2, though this result was not statistically significant (26.1% and 15.9%, respectively). M1 was further optimized, resulting in significantly greater PV1 recovery when compared to the original protocol (p < 0.05). This method can be used to improve understanding of enteric virus presence in communities without liquid waste streams.


Assuntos
Monitoramento Ambiental/métodos , Poliovirus/isolamento & purificação , Esgotos/virologia , Resíduos Sólidos/análise , Carga Viral/métodos , Infecções por Enterovirus/prevenção & controle , Floculação , Gastroenterite/prevenção & controle , Gastroenterite/virologia , Humanos , Poliomielite/prevenção & controle , Ensaio de Placa Viral/métodos , Microbiologia da Água
13.
Sci Total Environ ; 769: 144852, 2021 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-33486187

RESUMO

Environmental surveillance as a part of wastewater-based epidemiology (WBE) of SARS-CoV-2 can provide an early, cost-effective, unbiased community-level indicator of circulating COVID-19 in a population. The objective of this study was to determine how widely SARS-CoV-2 detection in wastewater is being investigated and what methods are used. A survey was developed and distributed, with results showing that methods were rapidly applied to conduct SARS-CoV-2 WBE, primarily to test wastewater influent from large urban wastewater treatment plants. Additionally, most methods utilized small wastewater volumes and the primary concentration methods used were polyethylene glycol precipitation, membrane filtration and centrifugal ultrafiltration followed by nucleic acid extraction and assay for primarily nucleocapsid gene targets (N1, N2, and/or N3). Since this survey was performed, many laboratories have continued to optimize and implement a variety of methods for SARS-CoV-2 WBE. Method comparison studies completed since this survey was conducted will assist in developing WBE as a supplemental tool to support public health and policy decision making responses.


Assuntos
COVID-19 , Águas Residuárias , Monitoramento Ambiental , Humanos , SARS-CoV-2 , Vigilância Epidemiológica Baseada em Águas Residuárias
15.
Food Environ Virol ; 12(1): 35-47, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31679104

RESUMO

The bag-mediated filtration system (BMFS) was developed to facilitate poliovirus (PV) environmental surveillance, a supplement to acute flaccid paralysis surveillance in PV eradication efforts. From April to September 2015, environmental samples were collected from four sites in Nairobi, Kenya, and processed using two collection/concentration methodologies: BMFS (> 3 L filtered) and grab sample (1 L collected; 0.5 L concentrated) with two-phase separation. BMFS and two-phase samples were analyzed for PV by the standard World Health Organization poliovirus isolation algorithm followed by intratypic differentiation. BMFS samples were also analyzed by a cell culture independent real-time reverse transcription polymerase chain reaction (rRT-PCR) and an alternative cell culture method (integrated cell culture-rRT-PCR with PLC/PRF/5, L20B, and BGM cell lines). Sabin polioviruses were detected in a majority of samples using BMFS (37/42) and two-phase separation (32/42). There was statistically more frequent detection of Sabin-like PV type 3 in samples concentrated with BMFS (22/42) than by two-phase separation (14/42, p = 0.035), possibly due to greater effective volume assayed (870 mL vs. 150 mL). Despite this effective volume assayed, there was no statistical difference in Sabin-like PV type 1 and Sabin-like PV type 2 detection between these methods (9/42 vs. 8/42, p = 0.80 and 27/42 vs. 32/42, p = 0.18, respectively). This study demonstrated that BMFS can be used for PV environmental surveillance and established a feasible study design for future research.


Assuntos
Monitoramento Ambiental/métodos , Filtração/métodos , Água Doce/virologia , Poliovirus/isolamento & purificação , Monitoramento Ambiental/instrumentação , Estudos de Viabilidade , Filtração/instrumentação , Água Doce/química , Humanos , Quênia , Poliomielite/virologia , Poliovirus/classificação , Poliovirus/genética
16.
Food Environ Virol ; 11(4): 364-373, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31571037

RESUMO

To enhance our ability to monitor poliovirus circulation and certify eradication, we evaluated the performance of the bag-mediated filtration system (BMFS) against the two-phase separation (TPS) method for concentrating wastewater samples for poliovirus detection. Sequential samples were collected at two sites in Mexico; one L was collected by grab and ~ 5 L were collected and filtered in situ with the BMFS. In the laboratory, 500 mL collected by grab were concentrated using TPS and the sample contained in the filter of the BMFS was eluted without secondary concentration. Concentrates were tested for the presence of poliovirus and non-poliovirus enterovirus (NPEV) using Global Poliovirus Laboratory Network standard procedures. Between February 16, 2016, and April 18, 2017, 125 pairs of samples were obtained. Collectors spent an average (± standard deviation) of 4.3 ± 2.2 min collecting the TPS sample versus 73.5 ± 30.5 min collecting and filtering the BMFS sample. Laboratory processing required an estimated 5 h for concentration by TPS and 3.5 h for elution. Sabin 1 poliovirus was detected in 37 [30%] samples with the TPS versus 24 [19%] samples with the BMFS (McNemar's mid p value = 0.004). Sabin 3 poliovirus was detected in 59 [47%] versus 49 (39%) samples (p = 0.043), and NPEV was detected in 67 [54%] versus 40 [32%] samples (p < 0.001). The BMFS method without secondary concentration did not perform as well as the TPS method for detecting Sabin poliovirus and NPEV. Further studies are needed to guide the selection of cost-effective environmental surveillance methods for the polio endgame.


Assuntos
Monitoramento Ambiental/métodos , Poliovirus/isolamento & purificação , Águas Residuárias/virologia , Filtração , México , Poliovirus/classificação , Poliovirus/genética , Esgotos/virologia , Águas Residuárias/química
17.
J Water Health ; 17(1): 113-123, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30758308

RESUMO

Ultraviolet disinfection (UVD) units enhance onsite sewage systems (OSSs) in areas where conventional treatment is limited by site characteristics. Although UVD units are efficacious under testing conditions, few studies have considered their effectiveness when installed. This study used a mixed-methods approach to examine UVD unit effluent quality and determine the association between UV bulb status and fecal coliform levels. Samples from UVD units and pump chambers were tested for bacterial and physiochemical parameters. Field data were supplemented with data from retrospective compliance samples. A multivariate Tobit regression model predicted that the geometric mean (GM) fecal coliform concentration was 122% higher when the UV bulb was deficient than when it was not deficient, adjusted for other OSS deficiencies (95% CI: 36-428, p-value <0.001). The predicted GM fecal coliform concentration in malfunctioning UVD unit effluent (745 CFU/100 mL) exceeded field compliance standards (400 CFU/100 mL), and the odds of exceedance were 7.48 times higher when the UV bulb was deficient, adjusted for other OSS deficiencies (95% CI: 4.03-13.9, p-value <0.001). Despite limitations in the characterization of UV dose, the results validate the importance of UVD units to reduce bacterial loads and the need for further research into their field effectiveness.


Assuntos
Desinfecção , Raios Ultravioleta , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/microbiologia , Enterobacteriaceae , Fezes , Estudos Retrospectivos , Esgotos
18.
Food Environ Virol ; 11(1): 20-31, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30612304

RESUMO

Effective surveillance of human enteric viruses is critical to estimate disease prevalence within a community and can be a vital supplement to clinical surveillance. This study sought to evaluate simple, effective, and inexpensive secondary concentration methods for use with ViroCap™ filter eluate for environmental surveillance of poliovirus. Wastewater was primary concentrated using cartridge ViroCap filters, seeded with poliovirus type 1 (PV1), and then concentrated using five secondary concentration methods (beef extract-Celite, ViroCap flat disc filter, InnovaPrep® Concentrating Pipette, polyethylene glycol [PEG]/sodium chloride [NaCl] precipitation, and skimmed-milk flocculation). PV1 was enumerated in secondary concentrates by plaque assay on BGMK cells. Of the five tested methods, PEG/NaCl precipitation and skimmed-milk flocculation resulted in the highest PV1 recoveries. Optimization of the skimmed-milk flocculation method resulted in a greater PV1 recovery (106 ± 24.8%) when compared to PEG/NaCl precipitation (59.5 ± 19.4%) (p = 0.004, t-test). The high PV1 recovery, short processing time, low reagent cost, no required refrigeration, and requirement for only standard laboratory equipment suggest that the skimmed-milk flocculation method would be a good candidate to be field-validated for secondary concentration of environmental ViroCap filter samples containing poliovirus.


Assuntos
Monitoramento Ambiental/métodos , Poliovirus/isolamento & purificação , Esgotos/virologia , Virologia/métodos , Microbiologia da Água , Floculação
19.
Clin Infect Dis ; 67(suppl_1): S90-S97, 2018 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-30376094

RESUMO

We performed a review of the environmental surveillance methods commonly used to collect and concentrate poliovirus (PV) from water samples. We compared the sampling approaches (trap vs grab), the process methods (precipitation vs filtration), and the various tools and chemical reagents used to separate PV from other viruses and pathogens in water samples (microporous glass, pads, polyethylene glycol [PEG]/dextran, PEG/sodium chloride, NanoCeram/ViroCap, and ester membranes). The advantages and disadvantages of each method are considered, and the geographical areas where they are currently used are discussed. Several methods have demonstrated the ability to concentrate and recover PVs from environmental samples. The details of the particular sampling conditions and locations should be considered carefully in method selection.


Assuntos
Monitoramento Ambiental , Poliomielite/virologia , Poliovirus/isolamento & purificação , Manejo de Espécimes/métodos , Humanos , Poliovirus/genética , Poliovirus/imunologia
20.
PLoS One ; 13(7): e0200551, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30011304

RESUMO

Poliovirus (PV) environmental surveillance (ES) plays an important role in the global eradication program and is crucial for monitoring silent PV circulation especially as clinical cases decrease. This study compared ES results using the novel bag-mediated filtration system (BMFS) with the current two-phase separation method. From February to November 2016, BMFS and two-phase samples were collected concurrently from twelve sites in Pakistan (n = 117). Detection was higher in BMFS than two-phase samples for each Sabin-like (SL) PV serotype (p<0.001) and wild PV type 1 (WPV1) (p = 0.065). Seventeen sampling events were positive for WPV1, with eight discordant in favor of BMFS and two in favor of two-phase. A vaccine-derived PV type 2 was detected in one BMFS sample but not the matched two-phase. After the removal of SL PV type 2 (SL2) from the oral polio vaccine in April 2016, BMFS samples detected SL2 more frequently than two-phase (p = 0.016), with the last detection by either method occurring June 12, 2016. More frequent PV detection in BMFS compared to two-phase samples is likely due to the greater effective volume assayed (1620 mL vs. 150 mL). This study demonstrated that the BMFS achieves enhanced ES for all PV serotypes in an endemic country.


Assuntos
Monitoramento Ambiental , Filtração , Poliovirus , Sorogrupo , Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos , Filtração/instrumentação , Filtração/métodos , Humanos , Paquistão/epidemiologia , Poliomielite/epidemiologia , Poliomielite/prevenção & controle , Poliovirus/genética , Poliovirus/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA