Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
J Cardiovasc Magn Reson ; : 101049, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38878969

RESUMO

BACKGROUND: The Plaque at RISK (PARISK) study demonstrated that patients with a carotid plaque with intraplaque hemorrhage (IPH) have an increased risk of recurrent ipsilateral ischemic cerebrovascular events. It was previously reported that symptomatic carotid plaques with IPH showed higher IPH signal intensity ratios (SIR) and larger IPH volumes than asymptomatic plaques. We explored whether IPH SIR and IPH volume are associated with future ipsilateral ischemic cerebrovascular events beyond the presence of IPH. METHODS: TIA and ischemic stroke patients with mild-to-moderate carotid stenosis and an ipsilateral IPH-positive carotid plaque (n=89) from the PARISK study were included. The clinical endpoint was a new ipsilateral ischemic cerebrovascular event during 5 years of follow-up, while the imaging-based endpoint was a new ipsilateral brain infarct on brain MRI after 2 years (n=69). Trained observers delineated IPH, a hyperintense region compared to surrounding muscle tissue on hyper T1-weighted MR images. The IPH SIR was the maximal signal intensity in the IPH region divided by the mean signal intensity of adjacent muscle tissue. The associations between IPH SIR or volume and the clinical and imaging-based endpoint were investigated using Cox-proportional hazard models and logistic regression, respectively. RESULTS: During 5.1 (interquartile range (IQR): 3.1-5.6) years of follow-up, 21 ipsilateral cerebrovascular ischemic events were identified. Twelve new ipsilateral brain infarcts were identified on the 2-year neuro MRI. There was no association for IPH SIR or IPH volume with the clinical endpoint (HR: 0.89 [95% CI: 0.67-1.10] and HR: 0.91 [0.69-1.19] per 100µl increase, respectively) nor with the imaging-based endpoint (OR: 1.04 [0.75-1.45] and OR: 1.21 [0.87-1.68] per 100µl increase, respectively). CONCLUSIONS: IPH SIR and IPH volume were not associated with future ipsilateral ischemic cerebrovascular events. Therefore, quantitative assessment of IPH does not seem to provide additional value beyond the presence of IPH for stroke risk assessment. Trial registration The PARISK study was registered on ClinicalTrials.gov with ID NCT01208025 on 21 September 2010 (https://clinicaltrials.gov/study/NCT01208025).

2.
Muscle Nerve ; 69(5): 588-596, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38459960

RESUMO

INTRODUCTION/AIMS: Nerve conduction studies (NCSs) are widely used to support the clinical diagnosis of neuromuscular disorders. The aims of this study were to obtain reference values for peroneal, tibial, and sural NCSs and to examine the associations with demographic and anthropometric factors. METHODS: In 5099 participants (aged 40-79 years) without type 2 diabetes of The Maastricht Study, NCSs of peroneal, tibial, and sural nerves were performed. Values for compound muscle action potential (CMAP) and sensory nerve action potential amplitude, nerve conduction velocity (NCV), and distal latency were acquired. The association of age, sex, body mass index (BMI), and height with NCS values was determined using uni- and multivariate linear regression analyses. RESULTS: Detailed reference values are reported per decade for men and women. Significantly lower NCVs and longer distal latencies were observed in all nerves in older and taller individuals as well as in men. In these groups, amplitudes of the tibial and sural nerves were significantly lower, whereas a lower peroneal nerve CMAP was only significantly associated with age. BMI showed a multidirectional association. After correction for anthropometric factors in the multivariate analysis, the association between sex and NCS values was less straightforward. DISCUSSION: These values from a population-based dataset could be used as a reference for generating normative values. Our findings show the association of NCS values with anthropometric factors. In clinical practice, these factors can be considered when interpreting NCS values.


Assuntos
Diabetes Mellitus Tipo 2 , Nervo Sural , Masculino , Humanos , Feminino , Idoso , Nervo Tibial/fisiologia , Estudos de Condução Nervosa , Condução Nervosa/fisiologia , Valores de Referência , Nervo Fibular/fisiologia , Demografia
3.
Cerebrovasc Dis ; 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37984345

RESUMO

INTRODUCTION: Carotid atherosclerotic intraplaque hemorrhage (IPH) predicts stroke. Patients with a history of stroke are treated with antiplatelet agents to prevent secondary cardiovascular events. A positive association between previous antiplatelet use and IPH was reported in a cross-sectional analysis. We investigated changes in IPH over two years in patients who recently started versus those with continued antiplatelet use. METHODS: In the Plaque at Risk (PARISK) study, symptomatic patients with <70% ipsilateral carotid stenosis underwent carotid plaque MRI at baseline and after two years to determine IPH presence and volume. Participants were categorized into new users (starting antiplatelet therapy following the index event) and continued users (previous use of antiplatelet therapy before the index event). The association between previous antiplatelet therapy and the presence of IPH at baseline MRI was investigated using multivariable logistic regression analysis. IPH volume change over a period of two years, defined as the difference in volume between follow-up and baseline, was investigated in each group with a Wilcoxon signed-rank test. The IPH volume change was categorized as progression, regression, or no change. Using multivariable logistic regression, we investigated the association between new antiplatelet use and 1) newly developed ipsilateral or contralateral IPH and 2) IPH volume progression. RESULTS: A total of 108 patients underwent carotid MRI at baseline and follow-up. At baseline, previous antiplatelet therapy was associated with any IPH (OR=5.6, 95% CI: 1.3-23.1; p=0.02). Ipsilateral IPH volume did not change significantly during the two years in patients who continued receiving antiplatelet agents (86.4 mm3 [18.2-235.9] vs. 59.3 mm3 [11.4-260.3]; p=0.6) nor in the new antiplatelet users (n=31) (61.5 mm3 [0.0-166.9] vs. 27.7 mm3 [9.5-106.4]; p=0.4). Similar results of a nonsignificant change in contralateral IPH volume during those two years were observed in both groups (p>0.05). No significant associations were found between new antiplatelet use and newly developed IPH at two years (odds ratio (OR)=1.0, 95% CI:0.1-7.4) or the progression of IPH (ipsilateral: OR=2.4, 95% CI:0.3-19.1; contralateral: OR=0.3, 95% CI:0.01-8.5). CONCLUSION: Although the baseline association between IPH and previous antiplatelet therapy was confirmed in this larger cohort, the new onset of antiplatelet therapy after TIA/stroke was not associated with newly developed IPH or progression of IPH volume over the subsequent two years.

4.
Front Cardiovasc Med ; 10: 1227495, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37680565

RESUMO

Background and purpose: Carotid atherosclerotic plaques with a large lipid-rich necrotic core (LRNC), intraplaque hemorrhage (IPH), and a thin or ruptured fibrous cap are associated with increased stroke risk. Multi-sequence MRI can be used to quantify carotid atherosclerotic plaque composition. Yet, its clinical implementation is hampered by long scan times and image misregistration. Multi-contrast atherosclerosis characterization (MATCH) overcomes these limitations. This study aims to compare the quantification of plaque composition with MATCH and multi-sequence MRI. Methods: MATCH and multi-sequence MRI were used to image 54 carotid arteries of 27 symptomatic patients with ≥2 mm carotid plaque on a 3.0 T MRI scanner. The following sequence parameters for MATCH were used: repetition time/echo time (TR/TE), 10.1/4.35 ms; field of view, 160 mm × 160 mm × 2 mm; matrix size, 256 × 256; acquired in-plane resolution, 0.63 mm2× 0.63 mm2; number of slices, 18; and flip angles, 8°, 5°, and 10°. Multi-sequence MRI (black-blood pre- and post-contrast T1-weighted, time of flight, and magnetization prepared rapid acquisition gradient echo; acquired in-plane resolution: 0.63 mm2 × 0.63 mm2) was acquired according to consensus recommendations, and image quality was scored (5-point scale). The interobserver agreement in plaque composition quantification was assessed by the intraclass correlation coefficient (ICC). The sensitivity and specificity of MATCH in identifying plaque composition were calculated using multi-sequence MRI as a reference standard. Results: A significantly lower image quality of MATCH compared to that of multi-sequence MRI was observed (p < 0.05). The scan time for MATCH was shorter (7 vs. 40 min). Interobserver agreement in quantifying plaque composition on MATCH images was good to excellent (ICC ≥ 0.77) except for the total volume of calcifications and fibrous tissue that showed moderate agreement (ICC ≥ 0.61). The sensitivity and specificity of detecting plaque components on MATCH were ≥89% and ≥91% for IPH, ≥81% and 85% for LRNC, and ≥71% and ≥32% for calcifications, respectively. Overall, good-to-excellent agreement (ICC ≥ 0.76) of quantifying plaque components on MATCH with multi-sequence MRI as the reference standard was observed except for calcifications (ICC = 0.37-0.38) and fibrous tissue (ICC = 0.59-0.70). Discussion and conclusion: MATCH images can be used to quantify plaque components such as LRNC and IPH but not for calcifications. Although MATCH images showed a lower mean image quality score, short scan time and inherent co-registration are significant advantages.

5.
JACC Cardiovasc Imaging ; 15(10): 1715-1726, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36202450

RESUMO

BACKGROUND: Patients with symptomatic carotid stenosis are at high risk for recurrent stroke. The decision for carotid endarterectomy currently mainly relies on degree of stenosis (cutoff value >50% or 70%). Nevertheless, also, patients with mild-to-moderate stenosis still have a considerable recurrent stroke risk. Increasing evidence suggests that carotid plaque composition rather than degree of stenosis determines plaque vulnerability; however, it remains unclear whether this also provides additional information to improve clinical decision making. OBJECTIVES: The PARISK (Plaque At RISK) study aimed to improve the identification of patients at increased risk of recurrent ischemic stroke using multimodality carotid imaging. METHODS: The authors included 244 patients (71% men; mean age, 68 years) with a recent symptomatic mild-to-moderate carotid stenosis in a prospective multicenter cohort study. Magnetic resonance imaging (carotid and brain) and computed tomography angiography (carotid) were performed at baseline and after 2 years. The clinical endpoint was a recurrent ipsilateral ischemic stroke or transient ischemic attack (TIA). Cox proportional hazards models were used to assess whether intraplaque hemorrhage (IPH), ulceration, proportion of calcifications, and total plaque volume in ipsilateral carotid plaques were associated with the endpoint. Next, the authors investigated the predictive performance of these imaging biomarkers by adding these markers (separately and simultaneously) to the ECST (European Carotid Surgery Trial) risk score. RESULTS: During 5.1 years follow-up, 37 patients reached the clinical endpoint. IPH presence and total plaque volume were associated with recurrent ipsilateral ischemic stroke or TIA (HR: 2.12 [95% CI: 1.02-4.44] for IPH; HR: 1.07 [95% CI: 1.00-1.15] for total plaque volume per 100 µL increase). Ulcerations and proportion of calcifications were not statistically significant determinants. Addition of IPH and total plaque volume to the ECST risk score improved the model performance (C-statistics increased from 0.67 to 0.75-0.78). CONCLUSIONS: IPH and total plaque volume are independent risk factors for recurrent ipsilateral ischemic stroke or TIA in patients with mild-to-moderate carotid stenosis. These plaque characteristics improve current decision making. Validation studies to implement plaque characteristics in clinical scoring tools are needed. (PARISK: Validation of Imaging Techniques [PARISK]; NCT01208025).


Assuntos
Calcinose , Estenose das Carótidas , Ataque Isquêmico Transitório , AVC Isquêmico , Placa Aterosclerótica , Acidente Vascular Cerebral , Idoso , Calcinose/complicações , Artérias Carótidas/patologia , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/terapia , Estudos de Coortes , Constrição Patológica/complicações , Constrição Patológica/patologia , Feminino , Hemorragia/complicações , Humanos , Ataque Isquêmico Transitório/complicações , Ataque Isquêmico Transitório/etiologia , Imageamento por Ressonância Magnética/métodos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/etiologia
6.
Handb Clin Neurol ; 186: 407-431, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35772899

RESUMO

Thoraco-abdominal aneurysm (TAA) repair carries a significant risk of spinal cord infarction. The latter results from irreversible changes in the spinal cord arterial network, e.g., sacrifice of the segmental arteries. Intra-operative neurophysiology with somatosensory and especially motor evoked potential (SEP and MEP respectively) monitoring, has emerged as an effective tool to assess the efficiency of the collateral blood flow, detect reversible spinal cord ischemia and guide the peri-operative multidisciplinary management to prevent postoperative paraplegia. The main roles of such monitoring include diagnosis of spinal cord vs peripheral limb ischemia, titration of mean arterial pressure during aortic clamping, the guidance of selective re-implantation of critical segmental arteries, and management of hemodynamics in the immediate postoperative period. In addition, manipulation of the aortic arch and proximal descending aorta, adds the risk of cerebral infarction from both low flow state and/or thromboembolic events. As such, EEG monitoring may be a useful add-on for either assessment of the efficiency of cerebral cooling as a neuroprotective method and/or for detection and treatment of reversible cerebral ischemia. This chapter presents the multimodality approach to open TAA monitoring as a versatile tool for the prevention of devastating postoperative neurologic deficits.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Isquemia do Cordão Espinal , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/cirurgia , Potencial Evocado Motor/fisiologia , Humanos , Isquemia , Monitorização Intraoperatória/métodos , Medula Espinal/irrigação sanguínea , Isquemia do Cordão Espinal/prevenção & controle , Isquemia do Cordão Espinal/cirurgia
7.
eNeurologicalSci ; 27: 100400, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35592106

RESUMO

Background: Recent studies have revealed the importance of the gut brain axis in the development of Parkinson's disease (PD). It has also been suggested that the cross-sectional area (CSA) of the vagus nerve can be used in the diagnosis of PD. Here, we hypothesize that the CSA of the vagus nerve is decreased in PD patients compared to control participants. Methods: In this study we measured the CSA of the vagus nerve on both sides in 31 patients with PD and 51 healthy controls at the level of the common carotid artery using high-resolution ultrasound. Results: The mean CSA of the left vagus nerve in the PD and the control group was respectively 2.10 and 1.90 and of the right respectively 2.54 and 2.24 mm2. There is no difference in CSA of the vagus nerve in PD patients compared to controls (p = .079). The mean CSA of the right vagus nerve was significantly larger than the left (p < .001). Age, sex and autonomic symptoms were no significant predictors of the CSA of the vagus nerve. Conclusion: These findings show that the CSA of the vagus nerve using ultrasonography is not a reliable diagnostic tool in the diagnosis of PD.

8.
J Clin Med ; 12(1)2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36614870

RESUMO

The Esaote MyLab70 ultrasound system has been extensively used to evaluate arterial properties. Since it is reaching end-of-service-life, ongoing studies are forced to seek an alternative, with some opting for the Esaote MyLabOne. Biases might exist between the two systems, which, if uncorrected, could potentially lead to the misinterpretation of results. This study aims to evaluate a potential bias between the two devices. Moreover, by comparing two identical MyLabOne systems, this study also aims to investigate whether biases estimated between the MyLabOne and MyLab70 employed in this study could be generalized to any other pair of similar scanners. Using a phantom set-up, we performed n = 60 measurements to compare MyLab70 to MyLabOne and n = 40 measurements to compare the two MyLabOne systems. Comparisons were performed to measure diameter, wall thickness, and distension. Both comparisons led to significant biases for the diameter (relative bias: −0.27% and −0.30% for the inter- and intra-scanner model, respectively, p < 0.05) and wall thickness (relative bias: 0.38% and −1.23% for inter- and intra-scanner model, respectively p < 0.05), but not for distension (relative bias: 0.48% and −0.12% for inter- and intra-scanner model, respectively, p > 0.05). The biases estimated here cannot be generalized to any other pair of similar scanners. Therefore, longitudinal studies with large sample sizes switching between scanners should perform a preliminary comparison to evaluate potential biases between their devices. Furthermore, caution is warranted when using biases reported in similar comparative studies. Further work should evaluate the presence and relevance of similar biases in human data.

9.
J Neuroimaging ; 31(5): 814-825, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34270144

RESUMO

BACKGROUND AND PURPOSE: Reported cutoff values of the optic nerve sheath diameter (ONSD) for the diagnosis of elevated intracranial pressure (ICP) are inconsistent. This hampers ONSD as a possible noninvasive bedside monitoring tool for ICP. Because the influence of methodological differences on variations in cutoff values is unknown, we performed a narrative review to identify discrepancies in ONSD assessment methodologies and to investigate their effect on reported ONSD values. METHODS: We used a structured and quantitative approach in which each ONSD methodology found in the reviewed articles was categorized based on the characteristic appearance of the ultrasound images and ultrasound marker placement. Subsequently, we investigated the influence of the different methodologies on ONSD values by organizing the ONSDs with respect to these categories. RESULTS: In a total of 63 eligible articles, we could determine the applied ONSD assessment methodology. Reported ultrasound images either showed the optic nerve and its sheath as a dark region with hyperechoic striped band at its edges or as a single dark region surrounded by lighter retrobulbar fat. Four different ultrasound marker positions were used to delineate the optic nerve sheath, which resulted in different ONSD values and more importantly, different sensitivities to changes in ICP. CONCLUSIONS: Based on our observations, we recommend to place ultrasound markers at the outer edges of the hyperechoic striped bands or at the transitions from the single dark region to the hyperechoic retrobulbar fat because these locations yielded the highest sensitivity of ONSD measurements for increased ICP.


Assuntos
Hipertensão Intracraniana , Ultrassonografia Doppler Transcraniana , Humanos , Pressão Intracraniana , Nervo Óptico/diagnóstico por imagem , Estudos Prospectivos , Ultrassonografia
10.
J Neuroimaging ; 31(4): 724-732, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33783910

RESUMO

BACKGROUND AND PURPOSE: The optic nerve sheath diameter (ONSD) is a promising surrogate marker for the detection of raised intracranial pressure (ICP). However, inconsistencies in manual ONSD assessment are thought to affect ONSD and the corresponding ONSD cutoff values for the diagnosis of elevated ICP, hereby hampering the full potential of ONSD. In this study, we developed an image intensity-invariant algorithm to automatically estimate ONSD from B-mode ultrasound images at multiple depths. METHODS: The outcomes of the algorithm were validated against manual ONSD measurements by two human experts. Each expert analyzed the images twice (M1 and M2) in unknown order. RESULTS: The algorithm proved capable of segmenting the ONSD in 39 of 42 images, hereby showing mean differences of -.08 ± .45 and -.05 ± .41 mm compared to averaged ONSD values (M1 + M2/2) of Operator 1 and Operator 2, respectively, whereas the mean difference between the two experts was .03 ± .26 mm. Moreover, differences between algorithm-derived and expert-derived ONSD values were found to be much smaller than the 1 mm difference that is expected between patients with normal and elevated ICP, making it likely that our algorithm can distinguish between these patient groups. CONCLUSIONS: Our algorithm has the potential to improve the accuracy of ONSD as a surrogate marker for elevated ICP because it has no intrinsic variability. However, future research should be performed to validate if the algorithm does indeed result in more accurate noninvasive ICP predictions.


Assuntos
Hipertensão Intracraniana , Pressão Intracraniana , Algoritmos , Humanos , Hipertensão Intracraniana/diagnóstico por imagem , Nervo Óptico/diagnóstico por imagem , Ultrassonografia
11.
Front Physiol ; 12: 787083, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34987417

RESUMO

Purpose: Carotid artery properties can be evaluated with high accuracy and reproducibility using multiple M-line ultrasound. However, the cost of multiple M-line-based imaging modalities and the extensive operator expertise requirements hamper the large-scale application for arterial properties assessment, particularly in resource-constrained settings. This study is aimed to assess the performance of a single M-line approach as an affordable and easy-to-use alternative to multiple M-line imaging for screening purposes. Methods: We used triplicate longitudinal common carotid artery (CCA) ultrasound recordings (17 M-lines covering about 16 mm, at 500 frames per second) of 500 subjects from The Maastricht Study to assess the validity and reproducibility of a single against multiple M-line approach. The multiple M-line measures were obtained by averaging over all available 17 lines, whereas the middle M-line was used as a proxy for the single M-line approach. Results: Diameter, intima-media thickness (IMT), and Young's elastic modulus (YEM) were not significantly different between the single and multiple M-line approaches (p > 0.07). Distension and distensibility coefficient (DC) did differ significantly (p < 0.001), however, differences were technically irrelevant. Similarly, Bland-Altman analysis revealed good agreement between the two approaches. The single M-line approach, compared to multiple M-line, exhibited an acceptable reproducibility coefficient of variation (CV) for diameter (2.5 vs. 2.2%), IMT (11.9 vs. 7.9%), distension (10 vs. 9.4%), DC (10.9 vs. 10.2%), and YEM (26.5 vs. 20.5%). Furthermore, in our study population, both methods showed a similar capability to detect age-related differences in arterial stiffness. Conclusion: Single M-line ultrasound appears to be a promising tool to estimate anatomical and functional CCA properties with very acceptable validity and reproducibility. Based on our results, we might infer that image-free, single M-line tools could be suited for screening and for performing population studies in low-resource settings worldwide. Whether the comparison between single and multiple M-line devices will yield similar findings requires further study.

12.
Diabetologia ; 63(8): 1648-1658, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32537727

RESUMO

AIMS/HYPOTHESIS: We aimed to examine associations of cardiometabolic risk factors, and (pre)diabetes, with (sensorimotor) peripheral nerve function. METHODS: In 2401 adults (aged 40-75 years) we previously determined fasting glucose, HbA1c, triacylglycerol, HDL- and LDL-cholesterol, inflammation, waist circumference, blood pressure, smoking, glucose metabolism status (by OGTT) and medication use. Using nerve conduction tests, we measured compound muscle action potential, sensory nerve action potential amplitudes and nerve conduction velocities (NCVs) of the peroneal, tibial and sural nerves. In addition, we measured vibration perception threshold (VPT) of the hallux and assessed neuropathic pain using the DN4 interview. We assessed cross-sectional associations of risk factors with nerve function (using linear regression) and neuropathic pain (using logistic regression). Associations were adjusted for potential confounders and for each other risk factor. Associations from linear regression were presented as standardised regression coefficients (ß) and 95% CIs in order to compare the magnitudes of observed associations between all risk factors and outcomes. RESULTS: Hyperglycaemia (fasting glucose or HbA1c) was associated with worse sensorimotor nerve function for all six outcome measures, with associations of strongest magnitude for motor peroneal and tibial NCV, ßfasting glucose = -0.17 SD (-0.21, -0.13) and ßfasting glucose = -0.18 SD (-0.23, -0.14), respectively. Hyperglycaemia was also associated with higher VPT and neuropathic pain. Larger waist circumference was associated with worse sural nerve function and higher VPT. Triacylglycerol, HDL- and LDL-cholesterol, and blood pressure were not associated with worse nerve function; however, antihypertensive medication usage (suggestive of history of exposure to hypertension) was associated with worse peroneal compound muscle action potential amplitude and NCV. Smoking was associated with worse nerve function, higher VPT and higher risk for neuropathic pain. Inflammation was associated with worse nerve function and higher VPT, but only in those with type 2 diabetes. Type 2 diabetes and, to a lesser extent, prediabetes (impaired fasting glucose and/or impaired glucose tolerance) were associated with worse nerve function, higher VPT and neuropathic pain (p for trend <0.01 for all outcomes). CONCLUSIONS/INTERPRETATION: Hyperglycaemia (including the non-diabetic range) was most consistently associated with early-stage nerve damage. Nonetheless, larger waist circumference, inflammation, history of hypertension and smoking may also independently contribute to worse nerve function.


Assuntos
Neuropatias Diabéticas/sangue , Neuropatias Diabéticas/patologia , Síndrome Metabólica/sangue , Nervos Periféricos/patologia , Adulto , Idoso , Glicemia/metabolismo , Fatores de Risco Cardiometabólico , Estudos Transversais , Eletrofisiologia , Feminino , Humanos , Masculino , Síndrome Metabólica/patologia , Pessoa de Meia-Idade , Condução Nervosa/fisiologia
13.
Contemp Clin Trials Commun ; 17: 100545, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32181411

RESUMO

BACKGROUND: During descending aortic repair, critically decreased blood flow to the myelum can result in ischemic spinal cord injury and transient or permanent paraplegia. Assessment of motor evoked potentials (MEPs) has been shown to be a valuable tool which allows to detect spinal cord ischemia (SCI) intraoperatively within a therapeutic window suitable to prevent progression to paraparesis or paraplegia. MEP monitoring is not feasible during postoperative care in the awakening patient. Therefore, ancillary techniques to monitor integrity of spinal cord function are needed to detect delayed spinal cord ischemia. OBJECTIVE: The purpose of this study is to evaluate whether assessment of long loop reflexes (LLR; F-waves) and paraspinal muscle oximetry using Near-Infrared Spectroscopy (NIRS) are feasible and valid in detecting delayed SCI. METHODS: We aim to include patients from three tertiary referral centers undergoing aortic repair with MEP monitoring in this study.F-wave measurements and paraspinal NIRS oximetry will be operated intra- and postoperatively. Measurement characteristics and feasibility will be assessed in the first 25 patients. Subsequently, a second cohort of 75 patients will be investigated to determine the sensitivity and specificity of F-waves and NIRS in detecting perioperative SCI. In this context for the MEP group SCI is defined intraoperatively as significant MEP changes and postoperatively as newly developed paraplegia. CONCLUSIONS: A clinical study design and protocol is proposed to assess if F-waves and/or NIRS-based paraspinal oximetry are feasible and valid in detecting and monitoring for occurrences of delayed SCI.

14.
Ann Vasc Surg ; 66: 424-433, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31923599

RESUMO

BACKGROUND: Despite all efforts, spinal cord ischemia (SCI) is a relevant and feared complication after open and endovascular thoracoabdominal aortic aneurysm (TAAA) repair. Besides the established correlation of motor evoked potentials (MEPs) and SCI, the usage of biomarkers for early detection of SCI intraoperatively and postoperatively after TAAA surgery is scarcely described in literature. METHODS: The methods include retrospective assessment of 33 patients (48.48% male) undergoing open and endovascular TAAA repair between January 2017 and January 2018. Levels of the biomarkers neurone-specific enolase (NSE), glial fibrillary acidic protein (GFAP), and S100 B were correlated with a decrease of the amplitude of the MEPs of more than 50%, indicating SCI. Linear mixed models were applied to test for differences in the biomarker levels between open and endovascular surgery and between different times of measurement. Post hoc analyses were performed using Tukey's multiple comparisons test. Logistic regression models were used to investigate the association between GFAP, NSE, and S100 B levels at different times and a significant decrease in MEP or in-hospital mortality. RESULTS: Altogether, 19 patients were treated by endovascular repair; 14 patients were treated by open repair; 5 patients were treated because of a type I TAAA; 7 received treatment because of a type II TAAA; 7, 10, and 4 patients received type III, IV, or V TAAA repair, respectively. In-hospital mortality was 18.18% (n = 6); 5 of these patients were treated because of symptomatic TAAA. MEP decrease could be observed in 18 cases (54.5%), with 16 (48.4%) recovering during the intervention. SCI could be observed in 9.09% (n = 3), 2 endovascular repairs leading to paraplegia and one open repair leading to paraparesis. All biomarkers showed increasing levels over time, with no statistically significant difference between open and endovascular repair. The difference in NSE and S100 B levels between the different times of measurements was statistically significant (P < 0.0001, P = 0.0017, respectively). In a univariable logistic regression analysis, no correlation with the end points "significant decrease in MEP" or "in-hospital mortality" was observed for any of the assessed biomarkers. CONCLUSIONS: SCI-related biomarkers, namely NSE and S100 B, show a relevant increase directly after open and endovascular TAAA surgery, while no clear association between these biomarker levels and an intraoperatively measurable indicator for SCI could be observed.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Proteína Glial Fibrilar Ácida/sangue , Fosfopiruvato Hidratase/sangue , Subunidade beta da Proteína Ligante de Cálcio S100/sangue , Isquemia do Cordão Espinal/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/sangue , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Biomarcadores/sangue , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/mortalidade , Potencial Evocado Motor , Feminino , Mortalidade Hospitalar , Humanos , Monitorização Neurofisiológica Intraoperatória , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/etiologia , Isquemia do Cordão Espinal/mortalidade , Fatores de Tempo , Resultado do Tratamento
15.
IEEE Trans Biomed Eng ; 67(4): 1030-1039, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31329544

RESUMO

Variations in systemic properties of the arterial tree, such as aging-induced vessel stiffness, can alter the shape of pressure and flow waveforms. As a consequence, the hemodynamics around a cerebral aneurysm change, and therefore, also the corresponding in- and outlet boundary conditions (BCs) used for three-dimensional (3D) calculations of hemodynamic indices. In this study, we investigate the effects of variations in systemic properties on wall shear stress (WSS) indices of a cerebral aneurysm. We created a virtual patient database by varying systemic properties within physiological ranges. BCs for 3D-CFD simulations were derived using a pulse wave propagation model for each realization of the virtual database. WSS indices were derived from the 3D simulations and their variabilities quantified. Variations in BCs, caused by changes in systemic properties, yielded variabilities in the WSS indices that were of the same order of magnitude as differences in these WSS indices between ruptured and unruptured aneurysms. Sensitivity analysis showed that the systemic properties impacted both in- and outlet BCs simultaneously and altered the WSS indices. We conclude that the influence of variations in patient-specific systemic properties on WSS indices should be evaluated when using WSS indices in multidisciplinary rupture prediction models.


Assuntos
Aneurisma Intracraniano , Hemodinâmica , Humanos , Hidrodinâmica , Aneurisma Intracraniano/diagnóstico por imagem , Modelos Cardiovasculares , Estresse Mecânico
16.
J Am Heart Assoc ; 8(8): e011832, 2019 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-30971168

RESUMO

Background Rupture of a vulnerable carotid atherosclerotic plaque is an important underlying cause of ischemic stroke. Increased leaky plaque microvasculature may contribute to plaque vulnerability. These immature microvessels may facilitate entrance of inflammatory cells into the plaque. The objective of the present study is to investigate whether there is a difference in plaque microvasculature (the volume transfer coefficient Ktrans) between the ipsilateral symptomatic and contralateral asymptomatic carotid plaque using noninvasive dynamic contrast-enhanced magnetic resonance imaging. Methods and Results Eighty-eight patients with recent transient ischemic attack or ischemic stroke and ipsilateral >2 mm carotid plaque underwent 3 T magnetic resonance imaging to identify plaque components and to determine characteristics of plaque microvasculature. The volume transfer coefficient Ktrans, indicative for microvascular density, flow, and permeability, was calculated for the ipsilateral and asymptomatic plaque, using a pharmacokinetic model (Patlak). Presence of a lipid-rich necrotic core, intraplaque hemorrhage, and a thin and/or ruptured fibrous cap was assessed on multisequence magnetic resonance imaging . We found significantly lower Ktrans in the symptomatic carotid plaque compared with the asymptomatic side (0.057±0.002 min-1 versus 0.062±0.002 min-1; P=0.033). There was an increased number of slices with intraplaque hemorrhage (0.9±1.6 versus 0.3±0.8, P=0.002) and lipid-rich necrotic core (1.4±1.9 versus 0.8±1.4, P=0.016) and a higher prevalence of plaques with a thin and/or ruptured fibrous cap (32% versus 17%, P=0.023) at the symptomatic side. Conclusions Ktrans was significantly lower in symptomatic carotid plaques, indicative for a decrease of plaque microvasculature in symptomatic plaques. This could be related to a larger amount of necrotic tissue in symptomatic plaques. Clinical Trial Registration URL : http://www.clinicaltrials.gov.uk . Unique identifier: NCT 01208025.


Assuntos
Doenças das Artérias Carótidas/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Idoso , Doenças Assintomáticas , Permeabilidade Capilar , Doenças das Artérias Carótidas/complicações , Estenose das Carótidas/complicações , Meios de Contraste , Feminino , Humanos , Ataque Isquêmico Transitório/etiologia , Imageamento por Ressonância Magnética , Masculino , Microvasos/metabolismo , Pessoa de Meia-Idade , Necrose , Placa Aterosclerótica/complicações , Fluxo Sanguíneo Regional , Acidente Vascular Cerebral/etiologia
17.
J Cardiovasc Magn Reson ; 21(1): 15, 2019 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-30832656

RESUMO

BACKGROUND: The presence of intraplaque haemorrhage (IPH) has been related to plaque rupture, is associated with plaque progression, and predicts cerebrovascular events. However, the mechanisms leading to IPH are not fully understood. The dominant view is that IPH is caused by leakage of erythrocytes from immature microvessels. The aim of the present study was to investigate whether there is an association between atherosclerotic plaque microvasculature and presence of IPH in a relatively large prospective cohort study of patients with symptomatic carotid plaque. METHODS: One hundred and thirty-two symptomatic patients with ≥2 mm carotid plaque underwent cardiovascular magnetic resonance (CMR) of the symptomatic carotid plaque for detection of IPH and dynamic contrast-enhanced (DCE)-CMR for assessment of plaque microvasculature. Ktrans, an indicator of microvascular flow, density and leakiness, was estimated using pharmacokinetic modelling in the vessel wall and adventitia. Statistical analysis was performed using an independent samples T-test and binary logistic regression, correcting for clinical risk factors. RESULTS: A decreased vessel wall Ktrans was found for IPH positive patients (0.051 ± 0.011 min- 1 versus 0.058 ± 0.017 min- 1, p = 0.001). No significant difference in adventitial Ktrans was found in patients with and without IPH (0.057 ± 0.012 min- 1 and 0.057 ± 0.018 min- 1, respectively). Histological analysis in a subgroup of patients that underwent carotid endarterectomy demonstrated no significant difference in relative microvessel density between plaques without IPH (n = 8) and plaques with IPH (n = 15) (0.000333 ± 0.0000707 vs. and 0.000289 ± 0.0000439, p = 0.585). CONCLUSIONS: A reduced vessel wall Ktrans is found in the presence of IPH. Thus, we did not find a positive association between plaque microvasculature and IPH several weeks after a cerebrovascular event. Not only leaky plaque microvessels, but additional factors may contribute to IPH development. TRIAL REGISTRATION: NCT01208025 . Registration date September 23, 2010. Retrospectively registered (first inclusion September 21, 2010). NCT01709045 , date of registration October 17, 2012. Retrospectively registered (first inclusion August 23, 2011).


Assuntos
Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Hemorragia/diagnóstico por imagem , Imageamento por Ressonância Magnética , Microvasos/diagnóstico por imagem , Placa Aterosclerótica , Idoso , Artérias Carótidas/patologia , Artérias Carótidas/cirurgia , Doenças das Artérias Carótidas/complicações , Doenças das Artérias Carótidas/patologia , Doenças das Artérias Carótidas/cirurgia , Meios de Contraste/administração & dosagem , Endarterectomia das Carótidas , Hemorragia/patologia , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Microvasos/patologia , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia
18.
Thromb Haemost ; 118(8): 1461-1469, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29972860

RESUMO

BACKGROUND: Carotid atherosclerosis is an important cause of stroke. Intra-plaque haemorrhage (IPH) on magnetic resonance imaging (MRI) increases stroke risk. Development of IPH is only partly understood. Thrombin is an essential enzyme in haemostasis. Experimental animal studies have shown conflicting results on the relation between thrombin and plaque vulnerability. We hypothesize that decreased thrombin generation (TG) is associated with IPH and plaque vulnerability. OBJECTIVE: This article investigates whether TG is associated with IPH and other features of plaque vulnerability in stroke patients. METHODS: Recently symptomatic stroke patients underwent carotid MRI and blood sampling. MRI plaque features include plaque burden, presence of IPH, amount of lipid-rich necrotic core (LRNC), calcified tissue and fibrous tissue (% of total wall volume). TG was assessed in platelet-poor plasma and expressed as: peak height (PH) and endogenous thrombin potential (ETP). MR images could be analysed in 224 patients. Blood samples were available in 161 of 224 patients. Binary multivariate logistic and linear regression were used to investigate the association between TG and MRI plaque features. RESULTS: IPH and LRNC were present in 65 (40%) and 102 (63%) of plaques. There were no significant associations between TG and IPH; PH odds ratio (OR) = 1, 95% confidence interval (CI): 0.76 to 1.45 and ETP OR = 1, 95% CI: 0.73 to 1.37. After correction for age, sex and hypercholesterolaemia, the association was weak but non-significant; PH: OR = 0.76, 95% CI: 0.52 to 1.10 and ETP: OR = 0.73, 95% CI: 0.53 to 1.37. CONCLUSION: Features of carotid plaque on MRI show no significant association with TG in stroke patients. Systemic TG does not seem to be an important factor in IPH development.


Assuntos
Estenose das Carótidas/complicações , Hemorragia/etiologia , Placa Aterosclerótica , Acidente Vascular Cerebral/etiologia , Trombina/metabolismo , Idoso , Biomarcadores/sangue , Estenose das Carótidas/sangue , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/patologia , Estudos Transversais , Progressão da Doença , Feminino , Fibrose , Hemorragia/sangue , Hemorragia/diagnóstico por imagem , Hemorragia/patologia , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Necrose , Países Baixos , Medição de Risco , Fatores de Risco , Ruptura Espontânea , Acidente Vascular Cerebral/sangue , Acidente Vascular Cerebral/patologia , Calcificação Vascular/complicações , Calcificação Vascular/patologia
19.
J Vasc Surg Cases Innov Tech ; 4(1): 54-57, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29725663

RESUMO

Ischemia of the spinal cord remains a disastrous complication in thoracoabdominal aortic aneurysm (TAAA) surgery. We report a case of open type I TAAA repair during which no motor evoked potentials were detectable for >1 hour after aortic cross-clamping. The creation of three intercostal artery bypasses restored spinal cord perfusion. As the patient showed only moderate clinical signs of spinal cord ischemia afterward, we underline the role of neuromonitoring to guide intercostal artery bypass implantation during TAAA surgery as the combined use of neuromonitoring and intercostal artery bypass implantation may prevent paraplegia in specific TAAA cases.

20.
Neurocrit Care ; 29(2): 195-202, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29589330

RESUMO

BACKGROUND: Currently, continuous electroencephalographic monitoring (cEEG) is the only available diagnostic tool for continuous monitoring of brain function in intensive care unit (ICU) patients. Yet, the exact relevance of routinely applied ICU cEEG remains unclear, and information on the implementation of cEEG, especially in Europe, is scarce. This study explores current practices of cEEG in adult Dutch ICU departments focusing on organizational and operational factors, development over time and factors perceived relevant for abstaining its use. METHODS: A national survey on cEEG in adults among the neurology and adult intensive care departments of all Dutch hospitals (n = 82) was performed. RESULTS: The overall institutional response rate was 78%. ICU cEEG is increasingly used in the Netherlands (in 37% of all hospitals in 2016 versus in 21% in 2008). Currently in 88% of university, 55% of teaching and 14% of general hospitals use ICU cEEG. Reasons for not performing cEEG are diverse, including perceived non-feasibility and lack of data on the effect of cEEG use on patient outcome. Mostly, ICU cEEG is used for non-convulsive seizures or status epilepticus and prognostication. However, cEEG is never or rarely used for monitoring cerebral ischemia and raised intracranial pressure in traumatic brain injury. Review and reporting practices differ considerably between hospitals. Nearly all hospitals perform non-continuous review of cEEG traces. Methods for moving toward continuous review of cEEG traces are available but infrequently used in practice. CONCLUSIONS: cEEG is increasingly used in Dutch ICUs. However, cEEG practices vastly differ between hospitals. Future research should focus on uniform cEEG practices including unambiguous EEG interpretation to facilitate collaborative research on cEEG, aiming to provide improved standard patient care and robust data on the impact of cEEG use on patient outcome.


Assuntos
Cuidados Críticos/estatística & dados numéricos , Eletroencefalografia/estatística & dados numéricos , Unidades de Terapia Intensiva/estatística & dados numéricos , Neurologistas/estatística & dados numéricos , Monitorização Neurofisiológica/estatística & dados numéricos , Utilização de Procedimentos e Técnicas/estatística & dados numéricos , Convulsões/diagnóstico , Pesquisas sobre Atenção à Saúde/estatística & dados numéricos , Humanos , Países Baixos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA