Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Ann Cardiol Angeiol (Paris) ; 73(5): 101786, 2024 Aug 09.
Artigo em Francês | MEDLINE | ID: mdl-39126902

RESUMO

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) has become the treatment of choice for the most fragile patients with severe aortic stenosis. The transfemoral route is preferred as the simplest and safest. The aim of our study was to compare the efficacy, tolerance and safety of local vs. locoregional anesthesia in trans-femoral TAVI procedures. MATERIAL AND METHOD: This was a single-center retrospective study. Patients treated with femoral TAVI between February 25 and November 15, 2022 at the University Hospital of Reims were included, and two groups (local and locoregional anesthesia) were compared. RESULTS: TAVI success rate (92.9%), death rate (3.0%) and procedure duration (90.5 ± 13.5 minutes) did not differ between groups (p = 0.18, 0.15 and 0.55 respectively). For intra- and post-procedural treatments, the use of sedation, analgesics and benzodiazepines did not differ between groups. The cumulative dose of Remifentanil used per-procedure was lower in the local anesthesia group than in the locoregional anesthesia group (148.6 ± 71.9 mcg vs. 208.9 ± 110.0 mcg; p = 0.025). CONCLUSIONS: In this non-randomized retrospective study, local and locoregional anesthesia had comparable safety and efficacy in transfemoral TAVI procedures. In a constrained context and with a view to simplification, these results encourage transfemoral TAVIs to be performed under local anaesthesia, and to consider a "PCI-like" approach, without the presence of an anaesthetist, for selected patients without respiratory, musculoskeletal or agitation disorders, or vascular approach difficulties.

2.
Arch Cardiovasc Dis ; 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39153878

RESUMO

BACKGROUND: Transthyretin amyloid cardiomyopathy (ATTR-CM) can manifest as rhythm disorders, heart failure, but also valvular degeneration. Despite aortic stenosis (AS) being prevalent among the elderly, data on ATTR-CM prevalence and outcome in patients with AS undergoing transaortic valve implantation (TAVI) remain scarce. AIM: To determine ATTR-CM prevalence and evaluate 1-year survival in patients undergoing TAVI. METHODS: Between December 2020 and September 2021, 100 consecutive patients underwent TAVI and were screened prospectively for ATTR-CM using bone scintigraphy (BS). Monoclonal gammopathy was ruled out in case of cardiac uptake on BS. All patients were followed prospectively for 1year after TAVI. RESULTS: The proportion of patients aged≥75years or with a EuroSCORE II>8% and possible femoral access was 99%. The abnormal cardiac uptake rate on BS was 7% (95% confidence interval: 2-12%); 86% of these patients were male. The RAISE (remodelling, age, injury, system and electrical) score, indicative of ATTR-CM risk, was higher in case of positive BS (P=0.04). Patients with positive BS were older and exhibited wider QRS complexes on electrocardiography (P=0.003), a higher frequency of reduced LVEF (57% vs. 17%), impaired basal LV strain (P=0.02) and a lower voltage/mass ratio (P=0.01). History of pacemaker implantation before TAVI was higher in the positive BS group (P=0.0004) and remained the only statistically significant factor after adjustment using the Holm-Bonferroni method. One-year survival of patients with positive BS did not differ from that of patients with isolated AS. CONCLUSIONS: Prevalence of ATTR-CM in patients treated with TAVI, underscoring the need for continued surveillance for potential development of ATTR-CM after TAVI. Caution is warranted regarding the 1-year survival because of the lack of study power. Further investigations are needed to define long-term prognosis of AS with ATTR-CM.

3.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38763211

RESUMO

INTRODUCTION AND OBJECTIVES: In patients undergoing percutaneous coronary intervention (PCI) in the workup pre-transcatheter aortic valve replacement (TAVR), the clinical impact of coronary revascularization complexity remains unknown. This study sought to examine the impact of PCI complexity on clinical outcomes after TAVR in patients undergoing PCI in the preprocedural workup. METHODS: This was a multicenter study including consecutive patients scheduled for TAVR with concomitant significant coronary artery disease. Complex PCI was defined as having at least 1 of the following features: 3 vessels treated, ≥ 3 stents implanted, ≥ 3 lesions treated, bifurcation with 2 stents implanted, total stent length >60mm, or chronic total occlusion. The rates of major adverse cardiac events (MACE), including cardiovascular mortality, myocardial infarction, and coronary revascularization were evaluated. RESULTS: A total of 1550 patients were included, of which 454 (29.3%) underwent complex PCI in the pre-TAVR workup. After a median follow-up period of 2 [1-3] years after TAVR, the incidence of MACE was 9.6 events per 100 patients-years. Complex PCI significantly increased the risk of cardiac death (HR, 1.44; 95%CI, 1.01-2.07), nonperiprocedural myocardial infarction (HR, 1.52; 95%CI, 1.04-2.21), and coronary revascularization (HR, 2.46; 95%CI, 1.44-4.20). In addition, PCI complexity was identified as an independent predictor of MACE after TAVR (HR, 1.31; 95%CI, 1.01-1.71; P=.042). CONCLUSIONS: In TAVR candidates with significant coronary artery disease requiring percutaneous treatment, complex revascularization was associated with a higher risk of MACE. The degree of procedural complexity should be considered a strong determinant of prognosis in the PCI-TAVR population.

4.
J Clin Med ; 12(22)2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-38002738

RESUMO

About half of the transcatheter aortic valve replacement (TAVR) recipients exhibit some degree of coronary artery disease (CAD), and controversial results have been reported regarding the impact of the presence and severity of CAD on clinical outcomes post-TAVR. In addition to coronary angiography, promising data has been recently reported on the use of both cardiac computed tomography angiography and the functional invasive assessment of coronary lesions whether by FFR or iFR in the work-up pre-TAVR. Despite mitigated available data, percutaneous revascularization of significant coronary lesions has been the routine strategy in TAVR candidates with CAD. Additionally, scarce data exists on the incidence, characteristics and management of coronary events post-TAVR, and increasing interest exists on the potential coronary access challenges in patients requiring coronary angiography/intervention post-TAVR. This review provides an updated overview of the knowledge of CAD in TAVR recipients, focusing on its prevalence, clinical impact, pre- and post-procedural evaluation and management.

5.
JACC Cardiovasc Interv ; 16(17): 2153-2164, 2023 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-37704301

RESUMO

BACKGROUND: In patients undergoing percutaneous coronary intervention (PCI) in the work-up pre-transcatheter aortic valve replacement (TAVR), the incidence and clinical impact of late bleeding events (LBEs) remain largely unknown. OBJECTIVES: This study sought to determine the incidence, clinical characteristics, associated factors, and outcomes of LBEs in patients undergoing PCI in the work-up pre-TAVR. METHODS: This was a multicenter study including 1,457 consecutive patients (mean age 81 ± 7 years; 41.5% women) who underwent TAVR and survived beyond 30 days. LBEs (>30 days post-TAVR) were defined according to the Valve Academic Research Consortium-2 criteria. RESULTS: LBEs occurred in 116 (7.9%) patients after a median follow-up of 23 (IQR: 12-40) months. Late bleeding was minor, major, and life-threatening or disabling in 21 (18.1%), 63 (54.3%), and 32 (27.6%) patients, respectively. Periprocedural (<30 days post-TAVR) major bleeding and the combination of antiplatelet and anticoagulation therapy at discharge were independent factors associated with LBEs (P ≤ 0.02 for all). LBEs conveyed an increased mortality risk at 4-year follow-up compared with no bleeding (43.9% vs 36.0; P = 0.034). Also, LBE was identified as an independent predictor of all-cause mortality after TAVR (HR: 1.39; 95% CI: 1.05-1.83; P = 0.020). CONCLUSIONS: In TAVR candidates with concomitant significant coronary artery disease requiring percutaneous treatment, LBEs after TAVR were frequent and associated with increased mortality. Combining antiplatelet and anticoagulation regimens and the occurrence of periprocedural bleeding determined an increased risk of LBEs. Preventive strategies should be pursued for preventing late bleeding after TAVR, and further studies are needed to provide more solid evidence on the most safe and effective antithrombotic regimen post-TAVR in this challenging group of patients.


Assuntos
Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Hemorragia/induzido quimicamente , Catéteres
6.
J Pers Med ; 13(4)2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-37108975

RESUMO

(1) Background: Receiving the first internal electric shock is a turning point for patients with an implantable cardioverter defibrillator (ICD) for primary prevention. However, no study has investigated whether patients who receive a first device-delivered electric shock have a poor prognosis even at the time of ICD implantation. (2) Methods: We retrospectively identified 55 patients with ischemic (n = 31) or dilated (n = 24) cardiomyopathy who underwent ICD implantation for primary prevention with exercise test at the time of implantation. We recorded baseline characteristics, exercise test parameters, and clinical events. (3) Results: After a median follow-up of 5 years, we observed an association between an appropriate device-delivered electric shock, the occurrence of death or heart transplant, and the occurrence of the composite endpoint. There was also a significant relation between a VE/VCO2 slope >35 and the occurrence of the composite endpoint. Conversely, there was no significant association between negative outcomes on the exercise test and the occurrence of a device-delivered electric shock. (4) Conclusions: The exercise test performed at the time of ICD implantation do not predict the occurrence of device-delivered electric shock. The exercise test and the first electric shock are two independent markers of poor prognosis.

7.
Arch Cardiovasc Dis ; 116(3): 117-125, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36702719

RESUMO

BACKGROUND: Two therapeutic strategies are available when aortic stenosis and coronary artery disease coexist: a transcatheter approach, with percutaneous coronary intervention followed by transcatheter aortic valve replacement; and a surgical approach, consisting of surgical aortic valve replacement combined with coronary artery bypass graft. AIM: We sought to compare the outcomes of these two strategies. METHODS: The study population consisted of 241 patients who benefited from aortic valve replacement and coronary revascularization (transcatheter, n=150; surgery, n=91). RESULTS: Patients in the transcatheter population were older (83.5 vs. 71.8years; P<0.001) and had a higher Logistic EuroSCORE (11.1% vs. 5.7%; P<0.001). At 30days postprocedure, patients who had surgery exhibited more life-threatening bleedings (12.1% vs 4.5%; P=0.034), acute kidney injury (12.1% vs. 1.3%; P<0.001) and atrial fibrillation (55.6% vs. 8.7%; P<0.001). After a median follow-up of 27months, the risk of major adverse cardiovascular or cerebrovascular events did not differ significantly between the two strategies (hazard ratio [HR] 1.41, 95% confidence interval [CI] 0.97-2.04; P=0.07), whereas estimated glomerular filtration rate<60mL/min (HR 2.22, 95% CI 1.58-3.12; P<0.001), peripheral artery disease (HR 2.00, 95% CI 1.37-2.91; P<0.001) and left ventricular ejection fraction<50% (HR 1.69, 95% CI 1.12-2.55; P=0.012) were associated with a negative prognosis. CONCLUSIONS: In our study, patients with aortic stenosis and coronary artery disease treated by catheter were older and had a higher co-morbidity burden than those treated by surgery. The surgical strategy was associated with a higher rate of 30-day complications, but long-term outcomes were similar between the two strategies.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/terapia , Volume Sistólico , Fatores de Risco , Resultado do Tratamento , Função Ventricular Esquerda , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Catéteres
8.
JTCVS Tech ; 15: 46-53, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36276673

RESUMO

Objectives: To compare the outcomes after transcatheter aortic valve replacement (TAVR) through a transfemoral (TF) and transcarotid (TC) access at our institution. Methods: From January 2014 to January 2020, 62 TC-TAVR and 449 TF-TAVR were performed using 2 prosthesis devices (Edwards SAPIEN 3, n = 369; Medtronic Evolut R, n = 142). Propensity score matching was used to adjust for imbalance in the baseline characteristics of the study groups. Results: Propensity score matching provided 62 matched pairs with comparable operative risk (mean European System for Cardiac Operative Risk Evaluation II, TC-TAVR 7.6% vs TF-TAVR 6.6%, P = .17). Thirty-day mortality (4.8% vs 3.2%, P = 1.00) and 2-year mortality (11.3% vs 12.9%, P = .64) after TC-TAVR were comparable with TF-TAVR. Strokes were numerically more frequent after TC-TAVR compared with TF-TAVR (3.2% vs 0%, P = .23), but the difference did not reach statistical significance. TF-TAVR was associated with a significantly greater risk of permanent pacemaker implantation (29.0% vs 12.9%, P = .04) compared with TC-TAVR. Other complications were not frequent and were similarly distributed between the matched groups. Conclusions: TC access for TAVR was associated with satisfactory results compared to the femoral access. TC-TAVR could be considered a valid and safe alternative to TF-TAVR when femoral access is contraindicated.

9.
J Radiol Prot ; 42(3)2022 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-35901783

RESUMO

Management of left-sided accessory pathways (APs) is based on catheter ablation through an antegrade or retrograde approach. Both are safe and effective but are associated with exposure to x-rays; however, recipients of ablation are generally young. We sought to evaluate the impact of the approach chosen on dose-area product (DAP). A total of 95 patients who underwent radiofrequency ablation of a left-sided AP between January 2011 and January 2020 were included. The primary endpoint was the radiation dose received by the patient. Secondary endpoints were procedural success and complication and recurrence rates. The mean age of the study population was 34.3 ± 16.6 years. The antegrade transseptal approach was used in 63.5% of cases. By multivariate analysis, the antegrade transseptal approach was associated with a 53% reduction in DAP (p< 0.001). The radiation dose received was also significantly associated with body mass index and total fluoroscopy time (p< 0.001). There was no significant difference in other secondary endpoints between approaches. The use of an antegrade transseptal approach is associated with a significant reduction in DAP compared with the retrograde approach, and procedural success and complication and recurrence rates are similar.


Assuntos
Ablação por Cateter , Exposição à Radiação , Adolescente , Adulto , Fluoroscopia , Humanos , Pessoa de Meia-Idade , Adulto Jovem
10.
JACC Cardiovasc Interv ; 14(22): 2490-2499, 2021 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-34794656

RESUMO

OBJECTIVES: The aim of this study was to compare, in a cohort of patients with complex coronary artery disease (CAD) and severe aortic stenosis (AS), the clinical outcomes associated with transfemoral transcatheter aortic valve replacement (TAVR) (plus percutaneous coronary intervention [PCI]) versus surgical aortic valve replacement (SAVR) (plus coronary artery bypass grafting [CABG]). BACKGROUND: Patients with complex CAD were excluded from the main randomized trials comparing TAVR with SAVR, and no data exist comparing TAVR + PCI vs SAVR + CABG in such patients. METHODS: A multicenter study was conducted including consecutive patients with severe AS and complex CAD (SYNTAX [Synergy Between PCI with Taxus and Cardiac Surgery] score >22 or unprotected left main disease). A 1:1 propensity-matched analysis was performed to account for unbalanced covariates. The rates of major adverse cardiac and cerebrovascular events (MACCE), including all-cause mortality, nonprocedural myocardial infarction, need for new coronary revascularization, and stroke, were evaluated. RESULTS: A total of 800 patients (598 undergoing SAVR + CABG and 202 undergoing transfemoral TAVR + PCI) were included, and after propensity matching, a total of 156 pairs of patients were generated. After a median follow-up period of 3 years (interquartile range: 1-6 years), there were no significant differences between groups for MACCE (HR for transfemoral TAVR vs SAVR: 1.33; 95% CI: 0.89-1.98), all-cause mortality (HR: 1.25; 95% CI: 0.81-1.94), myocardial infarction (HR: 1.16; 95% CI: 0.41-3.27), and stroke (HR: 0.42; 95% CI: 0.13-1.32), but there was a higher rate of new coronary revascularization in the TAVR + PCI group (HR: 5.38; 95% CI: 1.73-16.7). CONCLUSIONS: In patients with severe AS and complex CAD, TAVR + PCI and SAVR + CABG were associated with similar rates of MACCE after a median follow-up period of 3 years, but TAVR + PCI recipients exhibited a higher risk for repeat coronary revascularization. Future trials are warranted.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Implante de Prótese de Valva Cardíaca , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Ann Thorac Surg ; 111(5): 1601-1606, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32950489

RESUMO

BACKGROUND: The impact of novel alternative access and valve type on radiation exposure during transcatheter aortic valve replacement (TAVR) has not yet been evaluated. This study sought to determine the impact of a transarterial approach and prosthesis type on physician and patient exposure to radiation during TAVR. METHODS: This was a prospective study including 140 consecutive patients undergoing TAVR by transfemoral (n = 102) or transcarotid (TC) (n = 38) access at 2 centers. Implanted valves were the self-expanding Evolut R/PRO system (Medtronic, Minneapolis, MN; n = 38) and the balloon-expandable SAPIEN 3 valve (Edwards Lifesciences, Irvine, CA; n = 102). The primary endpoint was first operator radiation exposure. The secondary endpoint was patient radiation exposure. RESULTS: First operator radiation exposure was 4-fold greater during TC TAVR (P < .001). The use of a self-expanding valve was associated with a longer x-ray time (P = .015) and a 2-fold greater first operator radiation dose (P = .018). Patient radiation dose was not significantly affected by arterial approach (P = .055) or valve type (P = .095). After adjustment for potential confounders, the TC approach remained associated with a 174.8% (95% confidence interval, 80.6-318.3, P < .001) increase in first operator radiation dose, whereas the use of a self-expanding valve no longer influenced the first operator dose (P = .630). CONCLUSIONS: TC access and the use of a self-expanding valve were associated with a 4- and 2-fold greater first operator radiation exposure during TAVR procedures, respectively. Unlike the arterial approach, the effect of bioprosthesis type on radiation exposure was mainly related to x-ray time and was no longer significant after adjustment.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Exposição à Radiação/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Artérias Carótidas , Feminino , Artéria Femoral , Humanos , Masculino , Exposição Ocupacional , Segurança do Paciente , Estudos Prospectivos , Desenho de Prótese
12.
JACC Cardiovasc Interv ; 13(22): 2601-2613, 2020 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-33069647

RESUMO

OBJECTIVES: This study sought to determine, in patients undergoing percutaneous coronary intervention (PCI) during the work-up pre-transcatheter aortic valve replacement (TAVR): 1) the clinical and peri-procedural PCI characteristics; 2) the long-term outcomes; and 3) the clinical events in those patients with complex coronary features. BACKGROUND: A PCI is performed in about 25% of TAVR candidates, but procedural features and late outcomes of pre-TAVR PCI remain largely unknown. METHODS: Multicenter study including 1197 consecutive patients who had PCI in the work-up pre-TAVR. A total of 1,705 lesions (1.5 ± 0.7 lesions per patient) were included. Death, stroke, myocardial infarction, and major adverse cardiovascular and cerebrovascular events (MACCE) were recorded, as well as target lesion failure (TLF) and target vessel failure (TVF). RESULTS: One-half of patients exhibited a multivessel disease and the mean SYNTAX (SYNergy between PCI with TAXUS and Cardiac Surgery) score was 12.1 ± 9.1. The lesions were of B2/C type, calcified, bifurcation, and ostial in 49.9%, 45.8%, 21.4%, and 19.3% of cases, respectively. After a median follow-up of 2 (interquartile range: 1 to 3) years, a total of 444 (37.1%) patients presented an MACCE. Forty patients exhibited TVF (3.3%), with TLF identified in 32 (2.7%) patients. By multivariable analysis, previous peripheral artery disease (p < 0.001), chronic obstructive pulmonary disease (p = 0.002), atrial fibrillation (p = 0.003), diabetes mellitus (p = 0.012), and incomplete revascularization (p = 0.014) determined an increased risk of MACCE. In patients with unprotected left main or SYNTAX score >32 (n = 128), TLF, TVF, and MACCE rates were 3.9%, 6.3%, and 35.9%, respectively (p = 0.378; p = 0.065, and p = 0.847, respectively, vs. the rest of the population). CONCLUSIONS: Patients undergoing PCI in the work-up pre-TAVR frequently exhibited complex coronary lesions and multivessel disease. PCI was successful in most cases, and TLF and TVF rates at 2-year follow-up were low, also among patients with high-risk coronary features. However, overall MACCE occurred in about one-third of patients, with incomplete revascularization determining an increased risk. These results should inform future studies to better determine the optimal revascularization strategy pre-TAVR.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Humanos , Fatores de Risco , Resultado do Tratamento
13.
Eur Heart J Case Rep ; 4(3): 1-5, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32617477

RESUMO

BACKGROUND: Endomyocardial fibrosis (EMF) is a rare cause of restrictive cardiomyopathy, mainly found in tropical/subtropical country. Endomyocardial fibrosis causes severe congestive symptoms and may lead to end-stage heart failure. CASE SUMMARY: A French Caucasian 44-year-old man without noticeable medical history and who had never travelled outside of France was hospitalized for a first episode of acute heart failure revealing an atypical appearance of the left ventricle. Cardiac magnetic resonance (CMR) identified EMF, but investigations did not identify any aetiology (no eosinophilia). Despite optimal management of chronic heart failure, functional class declined rapidly resulting in several hospitalizations for heart failure. The patient finally underwent an elective heart transplantation with good results at 6-month follow-up. DISCUSSION: Endomyocardial fibrosis exact physiopathology remains unclear, although association with eosinophilia has been reported. Diagnosis is challenging and is based on multi-modal imagery with a central role of CMR. There is no consensus on optimal management, medical therapy having poor outcomes and rate of peri-operative complications being high. Heart transplantation should be considered for eligible patients.

14.
Int J Cardiol Heart Vasc ; 29: 100555, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32551360

RESUMO

AIMS: This study aimed to determine the impact of the volume of epicardial fat on the duration of radiofrequency (RF) energy delivery during the procedure of ablation of atrial fibrillation (AF). METHODS: The volume of epicardial fat was measured from spiral computerized tomography scan. The primary endpoint was the duration of RF delivery for pulmonary vein isolation (PVI), and the overall total duration of RF application. Secondary endpoint was conversion of AF to sinus rhythm or organisation of the arrhythmia after PVI. RESULTS: From March 2015 to May 2018, 222 patients (45.5% with persistent AF) underwent a first RF catheter ablation procedure for AF. The total duration of RF delivery, and the duration of RF delivery specifically for PVI were significantly associated with higher total volume of epicardial fat (p = 0.0002; p = 0.009 respectively), periatrial (p = 0.003; p = 0.045) and periventricular epicardial fat (p = 0.001; p = 0.012). In multivariate analysis, total epicardial fat volume was not significantly associated with total RF delivery duration (p = 0.743). For patients with arrhythmia at the time of the procedure, patients who achieved conversion or organisation of their arrhythmia after PVI had similar levels of total epicardial fat to those whose arrhythmia persisted (65 ± 35.2 vs 74.5 ± 31.2 ml; p = 0.192). CONCLUSION: We observed a significant relation between total, periatrial, and periventricular epicardial fat, and the duration of RF delivery during ablation of AF. This relation was not significant by multivariate analysis meaning that epicardial fat may be a marker, but not an independent factor, of ablation complexity.

15.
Arch Cardiovasc Dis ; 113(3): 189-198, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32037133

RESUMO

BACKGROUND: Transcarotid and trans-subclavian access routes are increasingly used as alternative approaches for transcatheter aortic valve implantation (TAVI) when transfemoral access is not suitable. However, concerns remain about the risk of periprocedural stroke and long-term outcomes following transcarotid/trans-subclavian TAVI. AIMS: The present study sought to compare early and long-term outcomes of transcarotid/trans-subclavian TAVI versus transfemoral TAVI after propensity-score matching. METHODS: The 260 patients who underwent TAVI through a transfemoral (n=220), transcarotid (n=32) or trans-subclavian (n=8) approach at our institution over a 4-year period were identified. A 1:1 matching based on propensity score was performed, and led to a study population of 80 patients (40 transfemoral and 40 transcarotid/trans-subclavian). Primary endpoints were early complications; secondary endpoints were long-term outcomes. RESULTS: There were no differences in the baseline characteristics of the two groups. At 30 days after TAVI there were no significant differences between transfemoral and transcarotid/trans-subclavian TAVI in terms of death rates (5% vs 5%, respectively; P=1.00) and stroke rates (5% vs 2.5%, respectively; P=1.00). After a median follow-up of 21 months, the risk of death (P=0.95), stroke (P=0.82) and myocardial infarction (P=0.16) did not differ between the two groups. CONCLUSIONS: After propensity-score matching, no significant differences in early and long-term outcomes were observed between transfemoral and transcarotid/trans-subclavian TAVI. These findings should encourage heart teams to consider a transcarotid or trans-subclavian approach when transfemoral access is unavailable.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Artérias Carótidas , Cateterismo Periférico , Artéria Femoral , Artéria Subclávia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Feminino , Hemodinâmica , Humanos , Masculino , Infarto do Miocárdio/mortalidade , Pontuação de Propensão , Punções , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
16.
Circ Cardiovasc Interv ; 13(2): e008620, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31992059

RESUMO

BACKGROUND: Scarce data exist on coronary events following transcatheter aortic valve replacement (TAVR), and no study has determined the factors associated with poorer outcomes in this setting. This study sought to determine the clinical characteristics, outcomes, and prognostic factors of acute coronary syndrome (ACS) events following TAVR. METHODS: Multicenter cohort study including a total of 270 patients presenting an ACS after a median time of 12 (interquartile range, 5-17) months post-TAVR. Post-ACS death, myocardial infarction, stroke, and overall major adverse cardiovascular or cerebrovascular events were recorded. RESULTS: The ACS clinical presentation consisted of non-ST-segment-elevation myocardial infarction (STEMI) type 2 (31.9%), non-STEMI type 1 (31.5%), unstable angina (28.5%), and STEMI (8.1%). An invasive strategy was used in 163 patients (60.4%), and a percutaneous coronary intervention was performed in 97 patients (35.9%). Coronary access issues were observed in 2.5% and 2.1% of coronary angiography and percutaneous coronary intervention procedures, respectively. The in-hospital mortality rate was 10.0%, and at a median follow-up of 17 (interquartile range, 5-32) months, the rates of death, stroke, myocardial infarction, and major adverse cardiovascular or cerebrovascular events were 43.0%, 4.1%, 15.2%, and 52.6%, respectively. By multivariable analysis, revascularization at ACS time was associated with a reduction of the risk of all-cause death (hazard ratio, 0.54 [95% CI, 0.36-0.81] P=0.003), whereas STEMI increased the risk of all-cause death (hazard ratio, 2.06 [95% CI, 1.05-4.03] P=0.036) and major adverse cardiovascular or cerebrovascular events (hazard ratio, 1.97 [95% CI, 1.08-3.57] P=0.026). CONCLUSIONS: ACS events in TAVR recipients exhibited specific characteristics (ACS presentation, low use of invasive procedures, coronary access issues) and were associated with a poor prognosis, with a very high in-hospital and late death rate. STEMI and the lack of coronary revascularization determined an increased risk. These results should inform future studies to improve both the prevention and management of ACS post-TAVR.


Assuntos
Síndrome Coronariana Aguda/epidemiologia , Angina Instável/epidemiologia , Infarto do Miocárdio sem Supradesnível do Segmento ST/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Angina Instável/diagnóstico , Angina Instável/mortalidade , Angina Instável/terapia , Feminino , Mortalidade Hospitalar , Humanos , Incidência , Masculino , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio sem Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Intervenção Coronária Percutânea , Medição de Risco , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Espanha/epidemiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
17.
Am J Cardiol ; 125(1): 114-119, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31699362

RESUMO

Transcatheter aortic valve implantation (TAVI) is currently becoming an alternative to surgical valve replacement for patients at low risk, a population that is likely to experience an increase in the radiation-induced cancer risk following TAVI. We aimed to evaluate the overall exposure to ionizing radiation in patients who underwent transfemoral TAVI, including the procedure itself as well as the procedures performed in the preintervention work-up and the post-TAVI interventions. All patients who underwent transfemoral TAVI for symptomatic aortic stenosis in our center over a 26 months period were included. Dosimetric indicators from preprocedural coronary angiography and computed tomography (CT), the TAVI procedure, and any postprocedural interventions (electrophysiology study and/or pacemaker implantation) were collected and converted into an effective dose. A total of 119 transfemoral TAVI procedures were included. The mean cumulative effective dose (ED) was 37.3 mSv. Three irradiating procedures were necessary for 84 patients (71% of the population, i.e., coronary angiography, CT scan and the TAVI procedure itself), whereas 30 patients (25%) required a fourth procedure, and 5 required a fifth (4%). The majority of the dose was from the CT, while only 11% of the dose derived from the TAVI procedure itself. In conclusion, overall exposure to ionizing radiation for patients who underwent transfemoral TAVI seems acceptable, and the majority of the overall ED comes from the CT scan.


Assuntos
Estenose da Valva Aórtica/cirurgia , Fluoroscopia/efeitos adversos , Medição de Risco/métodos , Tomografia Computadorizada por Raios X/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Relação Dose-Resposta à Radiação , Feminino , Seguimentos , França/epidemiologia , Humanos , Incidência , Masculino , Lesões por Radiação/epidemiologia , Lesões por Radiação/etiologia , Estudos Retrospectivos , Fatores de Risco
18.
Arch Cardiovasc Dis ; 113(3): 159-167, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31732445

RESUMO

BACKGROUND: Transcatheter aortic valve replacement is now indicated in patients at intermediate surgical risk and will probably soon be indicated in patients at low surgical risk, for whom the occurrence of serious procedural complications is not acceptable. AIMS: We aimed to investigate whether simple arterial variables from computed tomography scanning can predict the occurrence of severe early complications in patients undergoing transfemoral TAVR. METHODS: All patients with symptomatic severe aortic stenosis treated by transfemoral transcatheter aortic valve replacement in our centre, and for whom computed tomography images were available, were included. An exhaustive analysis of preprocedural computed tomography scans was performed retrospectively, in search of arterial tortuosity and vascular calcifications. The primary endpoint was a composite 30-day safety endpoint. RESULTS: Overall, 175 patients were included. The primary endpoint was observed in 60 patients (35%). Abdominal aorta tortuosity was identified in 28 patients (16%) and was strongly associated with the occurrence of a complication (adjusted odds ratio 2.7, 95% confidence interval 1.1-6.6; P=0.03). There was no significant association between iliofemoral tortuosity or vascular calcification and the occurrence of complications. CONCLUSIONS: A tortuous abdominal aorta was found to be a predictor of the occurrence of a complication in patients undergoing transfemoral transcatheter aortic valve replacement. This computed tomography variable should therefore be taken into account when choosing the approach, especially for patients at intermediate and low surgical risk.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Aortografia , Angiografia por Tomografia Computadorizada , Complicações Pós-Operatórias/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Tomada de Decisão Clínica , Feminino , Hemodinâmica , Humanos , Masculino , Seleção de Pacientes , Complicações Pós-Operatórias/mortalidade , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
20.
Am J Cardiol ; 124(8): 1213-1217, 2019 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-31395297

RESUMO

Patients who underwent radiofrequency ablation of atrial fibrillation are exposed to X-rays not only during the procedure but also during the preprocedural computed tomography. No study has investigated the cumulative effective dose received by patients who underwent atrial fibrillation ablation and identified factors influencing this dose. We aimed to evaluate the overall exposure to ionizing radiation in patients who underwent radiofrequency ablation of atrial fibrillation. The secondary objective was to estimate the impact of obesity on this exposure. All patients who underwent a first attempt of radiofrequency ablation of atrial fibrillation in our center over a 21 months period were included. Dosimetric indicators from preprocedural computed tomography and the ablation procedure were collected and converted into an effective dose. A total of 144 radiofrequency ablation of atrial fibrillation were included. The mean cumulative effective dose was 11.4 mSv, and 82% of the dose was from the computed tomography. Obese patients received a dose that was 75% higher than normal-weight patients, and this increase remained significant by multivariate analysis. In conclusion, overall exposure to ionizing radiation for patients who underwent radiofrequency ablation of atrial fibrillation seems acceptable, and the majority of the overall effective dose comes from the computed tomography. Obese patients are exposed to a 75% higher dose than normal-weight patients.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Obesidade/complicações , Exposição à Radiação/efeitos adversos , Lesões por Radiação/epidemiologia , Tomografia Computadorizada por Raios X/efeitos adversos , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Relação Dose-Resposta à Radiação , Feminino , Fluoroscopia/efeitos adversos , Seguimentos , França/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Lesões por Radiação/etiologia , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA