RESUMO
PURPOSE: Cardiovascular simulators are used in the preclinical testing phase of medical devices. Their reliability increases the more they resemble clinically relevant scenarios. In this study, a physiologically actuated soft robotic left ventricle (SRLV) embedded in a hybrid (in silico- in vitro) simulator of the cardiovascular system is presented, along with its experimental and computational analysis. METHODS: A SRLV phantom, developed from a patient's CT scan using polyvinyl alcohol (PVA), is embedded in a hybrid cardiovascular simulator. We present an activation method in which the hydraulic pressure external ( P e ( t ) ) to the SRLV is continuously adapted to regulate the left ventricular volume ( V i ( t ) ), considering the geometry and material behavior of the SRLV and the left ventricular pressure ( P i ( t ) ). This activation method is verified using a finite element (FE) model of the SRLV and validated in the hybrid simulator. Different hemodynamic profiles are presented to test the flexibility of the method. RESULTS: Both the FE model and hybrid simulator could represent the desired in silico data ( P i ( t ) , V i ( t ) ) with the implemented activation method, with deviations below 8.09% in the FE model and mainly < 10% errors in the hybrid simulator. Only two measurements out of 32 exceeded the 10% threshold due to simulator setup limitations. CONCLUSION: The activation method effectively allows to represent various pressure-volume loops, as verified numerically, and validated experimentally in the hybrid simulator. This work presents a high-fidelity platform designed to simulate cardiovascular conditions, offering a robust foundation for future testing of cardiovascular medical devices under physiological conditions.
RESUMO
BACKGROUND: Peak oxygen uptake (pVO2) predicts mortality in heart failure patients on left ventricular assist device (LVAD) support. This follow-up of the PRO-VAD study examines the prognostic value of repeated pVO2 measurements during long-term follow-up. METHODS: This multicenter follow-up study included patients from the original PRO-VAD cohort who performed a cardiopulmonary exercise test (CPET) twice. Patients were categorized into four groups based on pVO2 levels at the two CPETs: Low at both tests, Low at the first and High at the second test, High at the first and Low at the second test, and High at both tests. Low pVO2 was defined as ≤14 mL/kg/min (or ≤12 mL/kg/min if beta-blocker tolerant), while values above these thresholds were considered High. Survival outcomes were analyzed using the Kaplan-Meier method and cause-specific Cox analysis. RESULTS: The study included 152 patients with repeated CPETs at approximately 6 and 12 months following LVAD implantation. The cohort showed slight but significant pVO2 improvement (median change: 0.4 mL/kg/min, P = 0.04). Persistently High pVO2 (76 patients) was associated with a fivefold reduction in mortality hazard (HR 0.20, P = 0.002), compared to persistently Low pVO2 (46 patients). Improvement from Low to High pVO2 (21 patients) displayed similar benefits (HR 0.21, P = 0.02). CONCLUSION: pVO2 measurements remain predictive of mortality upon reiteration in LVAD patients, with changes in pVO2 providing additional prognostic value in identifying patients with an excellent outcome on ongoing LVAD support and in identifying patients requiring further interventions.
RESUMO
AIMS: This EUROMACS study was conducted with the primary aim of investigating the association between a centre's annual caseload and postoperative outcomes among patients undergoing left ventricular assist device (LVAD) implantation. METHODS AND RESULTS: A total of 4802 patients identified between 2011 and 2020 from 35 participating centres were dichotomized based on the annual caseload of the treating centre at the time of device implant (≤30 vs. >30 LVAD implantations/year). The primary endpoint was 1-year survival. Secondary outcomes included overall survival analysis, device-related adverse events and readmissions. Cumulative follow-up was 10 003 patient-years, with a median follow-up of 1.54 years (interquartile range 0.52-3.15). Patients from higher volume centres more frequently presented in INTERMACS levels 1 and 2, suffered from right heart dysfunction and needed inotropic support. No difference was observed in adjusted 1-year survival. Adjusted overall survival probability was lower in higher volume centres (p = 0.002). In the subgroup analysis of HeartMate 3 devices only, higher volume centres were associated with decreased odds of 1-year survival (adjusted odds ratio 0.43, 95% confidence interval 0.20-0.97, p = 0.041). Similar findings were observed in the cumulative (i.e. learning curve) caseload analyses. CONCLUSION: In patients undergoing LVAD implantation, centre volume was not associated with 1-year survival, but was related to device-related adverse events. Patient profiles differed with respect to centre size. These findings underscore the necessity for ongoing quality improvement initiatives in all centres, regardless of their annual caseload. Efforts are needed to standardize patient selection and preconditioning to further improve patient outcome.
RESUMO
BACKGROUND: Cerebral perfusion may change depending on arterial cannulation site and may affect the incidence of neurologic adverse events in post-cardiotomy extracorporeal life support (ECLS). The current study compares patients' neurologic outcomes with three commonly used arterial cannulation strategies (aortic vs. subclavian/axillary vs. femoral artery) to evaluate if each ECLS configuration is associated with different rates of neurologic complications. METHODS: This retrospective, multicenter (34 centers), observational study included adults requiring post-cardiotomy ECLS between January 2000 and December 2020 present in the Post-Cardiotomy Extracorporeal Life Support (PELS) Study database. Patients with Aortic, Subclavian/Axillary and Femoral cannulation were compared on the incidence of a composite neurological end-point (ischemic stroke, cerebral hemorrhage, brain edema). Secondary outcomes were overall in-hospital mortality, neurologic complications as cause of in-hospital death, and post-operative minor neurologic complications (seizures). Association between cannulation and neurological outcomes were investigated through linear mixed-effects models. RESULTS: This study included 1897 patients comprising 26.5% Aortic (n = 503), 20.9% Subclavian/Axillary (n = 397) and 52.6% Femoral (n = 997) cannulations. The Subclavian/Axillary group featured a more frequent history of hypertension, smoking, diabetes, previous myocardial infarction, dialysis, peripheral artery disease and previous stroke. Neuro-monitoring was used infrequently in all groups. Major neurologic complications were more frequent in Subclavian/Axillary (Aortic: n = 79, 15.8%; Subclavian/Axillary: n = 78, 19.6%; Femoral: n = 118, 11.9%; p < 0.001) also after mixed-effects model adjustment (OR 1.53 [95% CI 1.02-2.31], p = 0.041). Seizures were more common in Subclavian/Axillary (n = 13, 3.4%) than Aortic (n = 9, 1.8%) and Femoral cannulation (n = 12, 1.3%, p = 0.036). In-hospital mortality was higher after Aortic cannulation (Aortic: n = 344, 68.4%, Subclavian/Axillary: n = 223, 56.2%, Femoral: n = 587, 58.9%, p < 0.001), as shown by Kaplan-Meier curves. Anyhow, neurologic cause of death (Aortic: n = 12, 3.9%, Subclavian/Axillary: n = 14, 6.6%, Femoral: n = 28, 5.0%, p = 0.433) was similar. CONCLUSIONS: In this analysis of the PELS Study, Subclavian/Axillary cannulation was associated with higher rates of major neurologic complications and seizures. In-hospital mortality was higher after Aortic cannulation, despite no significant differences in incidence of neurological cause of death in these patients. These results encourage vigilance for neurologic complications and neuromonitoring use in patients on ECLS, especially with Subclavian/Axillary cannulation.
Assuntos
Aorta , Oxigenação por Membrana Extracorpórea , Artéria Femoral , Humanos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Oxigenação por Membrana Extracorpórea/métodos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/estatística & dados numéricos , Idoso , Doenças do Sistema Nervoso/etiologia , Doenças do Sistema Nervoso/epidemiologia , Adulto , Artéria Subclávia , Cateterismo/métodos , Cateterismo/efeitos adversos , Cateterismo/estatística & dados numéricos , Cateterismo Periférico/métodos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/estatística & dados numéricos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Mortalidade Hospitalar/tendênciasRESUMO
OBJECTIVES: The potential risk of autograft dilatation and homograft stenosis after the Ross procedure mandates lifelong follow-up. This retrospective cohort study aimed to determine long-term outcome of the Ross procedure, investigating autograft and homograft failure patterns leading to reintervention. METHODS: All adults who underwent the Ross procedure between 1991 and 2018 at the University Hospitals Leuven were included, with follow-up data collected retrospectively. Autograft implantation was performed using the full root replacement technique. The primary end-point was long-term survival. Secondary end-points were survival free from any reintervention, autograft or homograft reintervention-free survival, and evolution of autograft diameter, homograft gradient and aortic regurgitation grade over time. RESULTS: A total of 173 adult patients (66% male) with a median age of 32 years (range 18-58 years) were included. External support at both the annulus and sinotubular junction was used in 38.7% (67/173). Median follow-up duration was 11.1 years (IQR, 6.4-15.9; 2065 patient-years) with 95% follow-up completeness. There was one (0.6%) perioperative death. Kaplan-Meier estimate for 15-year survival was 91.1% and Ross-related reintervention-free survival was 75.7% (autograft: 83.5%, homograft: 85%). Regression analyses demonstrated progressive neoaortic root dilatation (0.56 mm/year) and increase in homograft gradient (0.72 mmHg/year). CONCLUSIONS: The Ross procedure has the potential to offer excellent long-term survival and reintervention-free survival. These long-term data further confirm that the Ross procedure is a suitable option in young adults with aortic valve disease which should be considered on an individual basis.
Assuntos
Valva Aórtica , Humanos , Adulto , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto Jovem , Adolescente , Seguimentos , Valva Aórtica/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca/mortalidade , Reoperação/estatística & dados numéricos , Insuficiência da Valva Aórtica/cirurgia , Valva Pulmonar/transplante , Valva Pulmonar/cirurgia , Autoenxertos , Valvopatia Aórtica/cirurgiaRESUMO
OBJECTIVES: Post-cardiotomy extracorporeal life support (ECLS) cannulation might occur in a general post-operative ward due to emergent conditions. Its characteristics have been poorly reported and investigated This study investigates the characteristics and outcomes of adult patients receiving ECLS cannulation in a general post-operative cardiac ward. METHODS: The Post-cardiotomy Extracorporeal Life Support (PELS) is a retrospective (2000-2020), multicenter (34 centers), observational study including adult patients who required ECLS for post-cardiotomy shock. This PELS sub-analysis analyzed patients´ characteristics, in-hospital outcomes, and long-term survival in patients cannulated for veno-arterial ECLS in the general ward, and further compared in-hospital survivors and non-survivors. RESULTS: The PELS study included 2058 patients of whom 39 (1.9%) were cannulated in the general ward. Most patients underwent isolated coronary bypass grafting (CABG, n = 15, 38.5%) or isolated non-CABG operations (n = 20, 51.3%). The main indications to initiate ECLS included cardiac arrest (n = 17, 44.7%) and cardiogenic shock (n = 14, 35.9%). ECLS cannulation occurred after a median time of 4 (2-7) days post-operatively. Most patients' courses were complicated by acute kidney injury (n = 23, 59%), arrhythmias (n = 19, 48.7%), and postoperative bleeding (n = 20, 51.3%). In-hospital mortality was 84.6% (n = 33) with persistent heart failure (n = 11, 28.2%) as the most common cause of death. No peculiar differences were observed between in-hospital survivors and nonsurvivors. CONCLUSIONS: This study demonstrates that ECLS cannulation due to post-cardiotomy emergent adverse events in the general ward is rare, mainly occurring in preoperative low-risk patients and after a postoperative cardiac arrest. High complication rates and low in-hospital survival require further investigations to identify patients at risk for such a complication, optimize resources, enhance intervention, and improve outcomes.
Assuntos
Cateterismo , Oxigenação por Membrana Extracorpórea , Choque Cardiogênico , Humanos , Masculino , Feminino , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Cateterismo/efeitos adversos , Cateterismo/métodos , Choque Cardiogênico/terapia , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Mortalidade Hospitalar , AdultoRESUMO
Acute right ventricular failure (RVF) is prevalent in multiple disease states and is associated with poor clinical outcomes. Right-sided temporary mechanical circulatory support (tMCS) devices are used to unload RV congestion and increase cardiac output in cardiogenic shock (CS) with hemodynamically significant RVF. Several RV-tMCS device platforms are available; however consensus is lacking on patient selection, timing of escalation to RV-tMCS, device management, and device weaning. The purposes of this review are to 1) describe the current state of tMCS device therapies for acute RVF with CS, 2) discuss principles of escalation to RV-tMCS device therapy, 3) examine important aspects of clinical management for patients supported by RV-tMCS devices including volume management, anticoagulation, and positive pressure ventilation, and 4) provide a framework for RV-tMCS weaning.
RESUMO
OBJECTIVES: The use of ventricular assist devices (VADs) in children is increasing. However, absolute numbers in individual centres and countries remain small. Collaborative efforts such as the Paedi-European Registry for Patients with Mechanical Circulatory Support (EUROMACS) are therefore essential for combining international experience with paediatric VADs. Our goal was to present the results from the fourth Paedi-EUROMACS report. METHODS: All paediatric (<19 years) patients from the EUROMACS database supported by a VAD were included. Patients were stratified into a congenital heart disease (CHD) group and a group with a non-congenital aetiology. End points included mortality, a transplant and recovery. Cox proportional hazard models were used to explore associated factors for mortality, cerebrovascular accident and pump thrombosis. RESULTS: A total of 590 primary implants were included. The congenital group was significantly younger (2.5 vs 8.0 years, respectively, P < 0.001) and was more commonly supported by a pulsatile flow device (73.5% vs 59.9%, P < 0.001). Mortality was significantly higher in the congenital group (30.8% vs 20.4%, P = 0.009) than in the non-congenital group. However, in multivariable analyses, CHD was not significantly associated with mortality [hazard ratio (HR) 1.285; confidence interval (CI) 0.8111-2.036, P = 0.740]. Pump thrombosis was the most frequently reported adverse event (377 events in 132 patients; 0.925 events per patient-year) and was significantly associated with body surface area (HR 0.524, CI 0.333-0.823, P = 0.005), CHD (HR 1.641, CI 1.054-2.555, P = 0.028) and pulsatile flow support (HR 2.345, CI 1.406-3.910, P = 0.001) in multivariable analyses. CONCLUSIONS: This fourth Paedi-EUROMACS report highlights the increasing use of paediatric VADs. The patient populations with congenital and non-congenital aetiologies exhibit distinct characteristics and clinical outcomes.
Assuntos
Coração Auxiliar , Sistema de Registros , Humanos , Sistema de Registros/estatística & dados numéricos , Coração Auxiliar/estatística & dados numéricos , Coração Auxiliar/efeitos adversos , Criança , Pré-Escolar , Masculino , Feminino , Lactente , Europa (Continente)/epidemiologia , Adolescente , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/mortalidade , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Recém-NascidoRESUMO
OBJECTIVES: Restrictive cardiomyopathy is rare and is generally associated with worse clinical outcomes compared to other cardiomyopathies. Ventricular assist device (VAD) support for these children is seldom applied and often hampered by the surgical difficulties. METHODS: All paediatric (<19 years) patients with a restricted cardiomyopathy supported by a VAD from the EUROMACS database were included and compared to patients with a dilated cardiomyopathy (retrospective database analyses). Participating centres were retrospectively contacted to provide additional detailed echo and Swan Ganz measurements to analyse the effect of VAD support on pulmonary artery pressure and right ventricular function. RESULTS: Forty-four paediatric VAD-supported patients diagnosed with restricted cardiomyopathy were included, with a median age at implantation of 5.0 years. Twenty-six of the 44 patient with a restricted cardiomyopathy survived to transplantation (59.1%), 16 died (36.4%) and 2 are still on ongoing VAD support (4.5%) after a median duration of support of 95.5 days (interquartile range 33.3-217.8). Transplantation probability after 1 and 2 years of VAD support in patients with a restricted cardiomyopathy were comparable to patients with a dilated cardiomyopathy (52.3% vs 51.4% and 59.5% vs 60.1%, P = 0.868). However, mortality probability was higher in the restricted cardiomyopathy cohort (35.8% vs 17.0% and 35.8% vs 19.0%, P = 0.005). Adverse event rates were high (cerebrovascular accident in 31.8%, pump thrombosis in 29.5%, major bleeding 25.0%, eventual biventricular support in 59.1%). In the atrially cannulated group, cerebrovascular accident and pump thrombosis occurred in twice as much patients (21.1% vs 40.0%, P = 0.595 and 15.8% vs 40.0%, P = 0.464; probably non-significant due to the small numbers). Pulmonary arterial pressures improved after implantation of a VAD, and 6 patients who were initially labelled as ineligible due to pulmonary hypertension could eventually be transplanted. CONCLUSIONS: VAD support in children with a restricted cardiomyopathy is rarely performed. Mortality and adverse event rates are high. On the other hand, survival to cardiac transplantation was 59.1% with all patients surviving the 1st 30 days after cardiac transplantation. Pulmonary arterial pressures improved while on support, potentially making cardiac transplantation a viable option for previously ineligible children.
Assuntos
Cardiomiopatia Restritiva , Coração Auxiliar , Hemodinâmica , Humanos , Coração Auxiliar/efeitos adversos , Cardiomiopatia Restritiva/cirurgia , Masculino , Criança , Feminino , Pré-Escolar , Estudos Retrospectivos , Hemodinâmica/fisiologia , Resultado do Tratamento , Adolescente , Lactente , Transplante de Coração , Cardiomiopatia Dilatada/cirurgia , Cardiomiopatia Dilatada/fisiopatologia , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/mortalidadeRESUMO
Impaired primary hemostasis and dysregulated angiogenesis, known as a two-hit hypothesis, are associated with gastrointestinal (GI) bleeding in patients with continuous-flow left ventricular assist devices (CF-LVADs). Exercise is known to influence hemostasis and angiogenesis in healthy individuals; however, little is known about the effect in patients with CF-LVADs. The objective of this prospective observational study was to determine whether acute exercise modulates two-hit hypothesis mediators associated with GI bleeding in patients with a CF-LVAD. Twenty-two patients with CF-LVADs performed acute exercise either on a cycle ergometer for approximately 10 minutes or on a treadmill for 30 minutes. Blood samples were taken pre- and post-exercise to analyze hemostatic and angiogenic biomarkers. Acute exercise resulted in an increased platelet count (p < 0.00001) and platelet function (induced by adenosine diphosphate, p = 0.0087; TRAP-6, p = 0.0005; ristocetin, p = 0.0009). Additionally, high-molecular-weight vWF multimers (p < 0.00001), vWF collagen-binding activity (p = 0.0012), factor VIII (p = 0.034), angiopoietin-1 (p = 0.0026), and vascular endothelial growth factor (p = 0.0041) all increased after acute exercise. This pilot work demonstrates that acute exercise modulated two-hit hypothesis mediators associated with GI bleeding in patients with CF-LVADs.
RESUMO
Right-sided mechanical support of the Fontan circulation by existing devices has been compounded by the cross-sectional design of vena cava anastomosis to both pulmonary arteries. Our purpose was to investigate whether increasing inferior vena cava (IVC) flow with a rotary blood pump in the IVC only in an ovine animal model of Fontan would lead to acceptable superior vena cava (SVC) pressure. To achieve this, a Fontan circulation was established in four female sheep by anastomosing the SVC to the main pulmonary artery (MPA) and by interposing a Dacron graft between the IVC and the MPA. A rotary blood pump was then introduced in the graft, and the effect of incremental flows was observed at increasing flow regimen. Additionally, to stimulate increased pulmonary resistance, the experience was repeated in each animal with the placement of a restrictive band on the MPA distally to the SVC and Dacron graft anastomosis. Circulatory support of IVC flow alone increased the systemic cardiac output significantly, both with and without banding, indicating the feasibility of mechanical support of the Fontan circulation by increasing the flow only in the inferior vena cava. The increase in SVC pressure remained within acceptable limits, indicating the potential effectiveness of this mode of support. The findings suggest that increasing the flow only in the inferior vena cava is a feasible method for mechanical support of the Fontan circulation, potentially leading to an increase in cardiac output with acceptable increases in superior vena cava pressure.
RESUMO
OBJECTIVES: Most post-cardiotomy (PC) extracorporeal membrane oxygenation (ECMO) runs last less than 7 days. Studies on the outcomes of longer runs have provided conflicting results. This study investigates patient characteristics and short- and long-term outcomes in relation to PC ECMO duration, with a focus on prolonged (> 7 d) ECMO. DESIGN: Retrospective observational cohort study. SETTING: Thirty-four centers from 16 countries between January 2000 and December 2020. PATIENTS: Adults requiring post PC ECMO between 2000 and 2020. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Characteristics, in-hospital, and post-discharge outcomes were compared among patients categorized by ECMO duration. Survivors and nonsurvivors were compared in the subgroup of patients with ECMO duration greater than 7 days. The primary outcome was in-hospital mortality. Two thousand twenty-one patients were included who required PC ECMO for 0-3 days ( n = 649 [32.1%]), 4-7 days ( n = 776 [38.3%]), 8-10 days ( n = 263 [13.0%]), and greater than 10 days ( n = 333 [16.5%]). There were no major differences in the investigated preoperative and procedural characteristics among ECMO duration groups. However, the longer ECMO duration category was associated with multiple complications including bleeding, acute kidney injury, arrhythmias, and sepsis. Hospital mortality followed a U-shape curve, with lowest mortality in patients with ECMO duration of 4-7 days ( n = 394, 50.8%) and highest in patients with greater than 10 days ECMO support ( n = 242, 72.7%). There was no significant difference in post-discharge survival between ECMO duration groups. In patients with ECMO duration greater than 7 days, age, comorbidities, valvular diseases, and complex procedures were associated with nonsurvival. CONCLUSIONS: Nearly 30% of PC ECMO patients were supported for greater than 7 days. In-hospital mortality increased after 7 days of support, especially in patients undergoing valvular and complex surgery, or who had complications, although the long-term post-discharge prognosis was comparable to PC ECMO patients with shorter support duration.
Assuntos
Procedimentos Cirúrgicos Cardíacos , Oxigenação por Membrana Extracorpórea , Mortalidade Hospitalar , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Idoso , Fatores de Tempo , Estudos de CoortesRESUMO
Cardiovascular medical devices undergo a large number of pre- and post-market tests before their approval for clinical practice use. Sophisticated cardiovascular simulators can significantly expedite the evaluation process by providing a safe and controlled environment and representing clinically relevant case scenarios. The complex nature of the cardiovascular system affected by severe pathologies and the inherently intricate patient-device interaction creates a need for high-fidelity test benches able to reproduce intra- and inter-patient variability of disease states. Therefore, we propose an innovative cardiovascular simulator that combines in silico and in vitro modeling techniques with a soft robotic left ventricle. The simulator leverages patient-specific and echogenic soft robotic phantoms used to recreate the intracardiac pressure and volume waveforms, combined with an in silico lumped parameter model of the remaining cardiovascular system. Three different patient-specific profiles were recreated, to assess the capability of the simulator to represent a variety of working conditions and mechanical properties of the left ventricle. The simulator is shown to provide a realistic physiological and anatomical representation thanks to the use of soft robotics combined with in silico modeling. This tool proves valuable for optimizing and validating medical devices and delineating specific indications and boundary conditions.
RESUMO
OBJECTIVES: Although cardiogenic shock requiring extracorporeal life support after cardiac surgery is associated with high mortality, the impact of sex on outcomes of postcardiotomy extracorporeal life support remains unclear with conflicting results in the literature. We compare patient characteristics, in-hospital outcomes, and overall survival between females and males requiring postcardiotomy extracorporeal life support. METHODS: This retrospective, multicenter (34 centers), observational study included adults requiring postcardiotomy extracorporeal life support between 2000 and 2020. Preoperative, procedural, and extracorporeal life support characteristics, complications, and survival were compared between females and males. Association between sex and in-hospital survival was investigated through mixed Cox proportional hazard models. RESULTS: This analysis included 1823 patients (female: 40.8%; median age: 66.0 years [interquartile range, 56.2-73.0 years]). Females underwent more mitral valve surgery (females: 38.4%, males: 33.1%, P = .019) and tricuspid valve surgery (feamales: 18%, males: 12.4%, P < .001), whereas males underwent more coronary artery surgery (females: 45.9%, males: 52.4%, P = .007). Extracorporeal life support implantation was more common intraoperatively in feamales (females: 64.1%, females: 59.1%) and postoperatively in males (females: 35.9%, males: 40.9%, P = .036). Ventricular unloading (females: 25.1%, males: 36.2%, P < .001) and intra-aortic balloon pumps (females: 25.8%, males: 36.8%, P < .001) were most frequently used in males. Females had more postoperative right ventricular failure (females: 24.1%, males: 19.1%, P = .016) and limb ischemia (females: 12.3%, males: 8.8%, P = .23). In-hospital mortality was 64.9% in females and 61.9% in males (P = .199) with no differences in 5-year survival (females: 20%, 95% CI, 17-23; males: 24%, 95% CI, 21-28; P = .069). Crude hazard ratio for in-hospital mortality in females was 1.12 (95% CI, 0.99-1.27; P = .069) and did not change after adjustments. CONCLUSIONS: This study demonstrates that female and male patients requiring postcardiotomy extracorporeal life support have different preoperative and extracorporeal life support characteristics, as well as complications, without a statistical difference in in-hospital and 5-year survivals.
RESUMO
BACKGROUND: Stroke after durable left ventricular assist device (d-LVAD) implantation portends high mortality. The incidence of ischemic and hemorrhagic stroke and the impact on stroke outcomes of temporary mechanical circulatory support (tMCS) management among patients requiring bridge to d-LVAD with micro-axial flow-pump (mAFP, Abiomed) is unsettled. METHODS: Consecutive patients, who underwent d-LVAD implantation after being bridged with mAFP at 19 institutions, were retrospectively included. The incidence of early ischemic and hemorrhagic stroke after d-LVAD implantation (<60 days) and association of pre-d-LVAD characteristics and peri-procedural management with a specific focus on tMCS strategies were studied. RESULTS: Among 341 patients, who underwent d-LVAD implantation after mAFP implantation (male gender 83.6%, age 58 [48-65] years, mAFP 5.0/5.5 72.4%), the early ischemic stroke incidence was 10.8% and early hemorrhagic stroke 2.9%. The tMCS characteristics (type of mAFP device and access, support duration, upgrade from intra-aortic balloon pump, ECMELLA, ECMELLA at d-LVAD implantation, hemolysis, and bleeding) were not associated with ischemic stroke after d-LVAD implant. Conversely, the device model (mAFP 2.5/CP vs. mAFP 5.0/5.5: HR 5.6, 95%CI 1.4-22.7, p = 0.015), hemolysis on mAFP support (HR 10.5, 95% CI 1.3-85.3, p = 0.028) and ECMELLA at d-LVAD implantation (HR 5.0, 95% CI 1.4-18.7, p = 0.016) were associated with increased risk of hemorrhagic stroke after d-LVAD implantation. Both early ischemic (HR 2.7, 95% CI 1.9-4.5, p < 0.001) and hemorrhagic (HR 3.43, 95% CI 1.49-7.88, p = 0.004) stroke were associated with increased 1-year mortality. CONCLUSIONS: Among patients undergoing d-LVAD implantation following mAFP support, tMCS characteristics do not impact ischemic stroke occurrence, while several factors are associated with hemorrhagic stroke suggesting a proactive treatment target to reduce this complication.
Assuntos
Coração Auxiliar , Sistema de Registros , Humanos , Coração Auxiliar/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Incidência , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia , Insuficiência Cardíaca/terapia , AVC Isquêmico/etiologia , AVC Isquêmico/epidemiologia , Resultado do Tratamento , Acidente Vascular Cerebral Hemorrágico/etiologia , Acidente Vascular Cerebral Hemorrágico/epidemiologiaRESUMO
OBJECTIVES: This study aims to explore characteristics and clinical outcomes of patients with congenital heart disease (CHD) in the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). METHODS: This is a retrospective study of EUROMACS participants receiving MCS as bridge-to-transplant, possible bridge-to-transplant, or rescue therapy/bridge-to-recovery from 2011 to 2023 (n = 5340). Adult and paediatric cohorts were analysed separately. The primary outcome was mortality on MCS; secondary outcomes included recovery, transplant and complications including bleeding, cerebrovascular events, and sepsis. RESULTS: Among adult patients, mortality at 1-year was 33.3% among the CHD cohort vs 22.1% in the non-CHD cohort. Adult CHD patients had higher hazards of mortality within the first year after MCS implantation [hazard ratios 1.98, 95% confidence interval (CI) 1.35-2.91, P < 0.001] and bleeding events (subdistribution hazard ratios 2.10, 95% CI 1.40-3.16, P < 0.001) compared with non-CHD patients. Both associations remained significant after accounting for multiple mediators. Among paediatric patients, mortality at 1 year was 22.1% in the CHD cohort vs 17.3% in the non-CHD cohort (hazard ratios 1.39, 95% CI 0.83-2.32, P = 0.213). CONCLUSIONS: Adult and paediatric patients with CHD on MCS have higher adverse event risk compared with non-CHD MCS patients, though children did not have greater risk of mortality. As the number of CHD patients requiring advanced heart failure management continues to grow, these findings can enhance informed decision-making. CLINICAL TRIAL REGISTRATION NUMBER: Registry name: EUROMACS.
Assuntos
Cardiopatias Congênitas , Coração Auxiliar , Sistema de Registros , Humanos , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Adulto , Europa (Continente)/epidemiologia , Criança , Coração Auxiliar/estatística & dados numéricos , Coração Auxiliar/efeitos adversos , Adolescente , Pré-Escolar , Lactente , Transplante de Coração/estatística & dados numéricos , Adulto Jovem , Pessoa de Meia-IdadeRESUMO
OBJECTIVES: Decellularized aortic homografts (DAH) were introduced in 2008 as a further option for paediatric aortic valve replacement (AVR). METHODS: Prospective, multicentre follow-up of all paediatric patients receiving DAH for AVR in 8 European centres. RESULTS: A total of 143 DAH were implanted between February 2008 and February 2023 in 137 children (106 male, 74%) with a median age of 10.8 years (interquartile range 6.6-14.6). Eighty-four (59%) had undergone previous cardiac operations and 24 (17%) had undergone previous AVR. The median implanted DAH diameter was 21 mm (interquartile range 19-23). The median operation duration was 348 min (227-439) with a median cardiopulmonary bypass time of 212 min (171-257) and a median cross-clamp time of 135 min (113-164). After a median follow-up of 5.3 years (3.3-7.2, max. 15.2 years), the primary efficacy end-points peak gradient (median 14 mmHg, 9-28) and regurgitation (median 0.5, interquartile range 0-1, grade 0-3) showed good results but an increase over time. Freedom from death/explantation/endocarditis/bleeding/thromboembolism at 5 years were 97.8 ± 1.2/88.7 ± 3.3/99.1 ± 0.9/100 and 99.2 ± 0.8%, respectively. Freedom from death/explantation/endocarditis/bleeding/thromboembolism at 10 years were 96.3 ± 1.9/67.1 ± 8.0/93.6 ± 3.9/98.6 ± 1.4 and 86.9 ± 11.6%, respectively. In total, 21 DAH were explanted. Seven were replaced by a mechanical AVR, 1 Ross operation was performed and a re-do DAH was implanted in 13 patients with no redo mortality. The calculated expected adverse events were lower for DAH compared to cryopreserved homograft patients (mean age 8.4 years), and in the same range as for Ross patients (9.2 years) and mechanical AVR (13.0 years). CONCLUSIONS: This large-scale prospective analysis demonstrates excellent mid-term survival using DAH with adverse event rates comparable to paediatric Ross procedures.
Assuntos
Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Tromboembolia , Criança , Humanos , Masculino , Aloenxertos/cirurgia , Valva Aórtica/cirurgia , Endocardite/cirurgia , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Reoperação , Resultado do Tratamento , Feminino , AdolescenteRESUMO
OBJECTIVES: To investigate if there is still a place for bioprosthetic mitral valve replacement in children by comparing the prosthetic durability and transplant-free survival after bioprosthetic and mechanical mitral valve replacement. METHODS: We reviewed all mitral valve replacements in children between 1981 and 2020. Bioprosthetic mitral valve replacement cases were individually matched to mechanical mitral valve replacement cases. The incidence rate of a 2nd replacement was calculated using the cumulative incidence function that considered death or transplantation as a competing risk. RESULTS: The median age at implantation was 3.6 years (interquartile range 0.8-7.9) for the bioprosthetic valve cohort (n = 28) and 3 years (interquartile range 1.3-7.8) for the mechanical valve cohort (n = 28). Seven years after bioprosthetic mitral valve replacement, the cumulative incidence of death or transplantation was 17.9% [95% confidence interval (CI) 6.3-34.1] and the cumulative incidence of a 2nd replacement was 63.6% (95% CI 39.9-80.1). Seven years after mechanical mitral valve replacement, the cumulative incidence of death or transplantation was 28.6% (95% CI 13.3-46) and the cumulative incidence of a 2nd replacement was 10.7% (95% CI 2.6-25.5). Fifteen years after mechanical mitral valve replacement, the cumulative incidence of death or transplantation was 33.6% (95% CI 16.2-52.1) and the cumulative incidence of a 2nd replacement was 41.1% (95% CI 18.4-62.7). The cumulative incidence curves for bioprosthetic and mechanical mitral valve replacement were statistically different for a 2nd valve replacement (P < 0.001) but not for death or transplantation (P = 0.33). CONCLUSIONS: There is no difference in transplant-free survival after bioprosthetic and mechanical mitral valve replacement in children. The lifespan of bioprosthetic mitral valves remains limited in children because of structural valve failure due to calcification. After 15 years, 40% of mechanical valves were replaced, primarily because of patient-prosthesis mismatch related to somatic growth.
RESUMO
OBJECTIVES: Decellularized aortic homografts (DAH) were introduced as a new option for aortic valve replacement for young patients. METHODS: A prospective, EU-funded, single-arm, multicentre study in 8 centres evaluating non-cryopreserved DAH for aortic valve replacement. RESULTS: A total of 144 patients (99 male) were prospectively enrolled in the ARISE Trial between October 2015 and October 2018 with a median age of 30.4 years [interquartile range (IQR) 15.9-55.1]; 45% had undergone previous cardiac operations, with 19% having 2 or more previous procedures. The mean implanted DAH diameter was 22.6 mm (standard deviation 2.4). The median operation duration was 312 min (IQR 234-417), the median cardiopulmonary bypass time was 154 min (IQR 118-212) and the median cross-clamp time 121 min (IQR 93-150). No postoperative bypass grafting or renal replacement therapy were required. Two early deaths occurred, 1 due to a LCA thrombus on day 3 and 1 due ventricular arrhythmia 5 h postoperation. There were 3 late deaths, 1 death due to endocarditis 4 months postoperatively and 2 unrelated deaths after 5 and 7 years due to cancer and Morbus Wegener resulting in a total mortality of 3.47%. After a median follow-up of 5.9 years [IQR 5.1-6.4, mean 5.5 years. (standard deviation 1.3) max. 7.6 years], the primary efficacy end-points peak gradient with median 11.0 mmHg (IQR 7.8-17.6) and regurgitation of median 0.5 (IQR 0-0.5) of grade 0-3 were excellent. At 5 years, freedom from death/reoperation/endocarditis/bleeding/thromboembolism were 97.9%/93.5%/96.4%/99.2%/99.3%, respectively. CONCLUSIONS: The 5-year results of the prospective multicentre ARISE trial continue to show DAH to be safe for aortic valve replacement with excellent haemodynamics.