1.
Artigo em Inglês | MEDLINE | ID: mdl-35627347

RESUMO

An international comparison of continuous monitors measuring radon activity concentration was performed to validate the traceability of the European radon calibration facilities. It was carried out by comparing the secondary standards used by these previous facilities, ranging from 100 Bq·m-3 to 300 Bq·m-3. Secondary standards were individually compared to a secondary reference device previously calibrated in a reference radon atmosphere traceable to a primary standard. The intercomparison was organized by the National Institute for Nuclear, Chemical, and Biological Protection (SUJCHBO) in the period from October 2019 to April 2020 within the European Metrology Program for Innovation and Research (EMPIR), JRP-Contract 16ENV10 MetroRADON. Eight European laboratories participated in this study. The results of the experiment are presented and discussed.


Assuntos
Poluentes Radioativos do Ar , Monitoramento de Radiação , Radônio , Poluentes Radioativos do Ar/análise , Calibragem , Monitoramento de Radiação/métodos , Radônio/análise , Padrões de Referência
2.
Artigo em Inglês | MEDLINE | ID: mdl-34831904

RESUMO

An interlaboratory comparison for European radon calibration facilities was conducted to evaluate the establishment of a harmonized quality level for the activity concentration of radon in air and to demonstrate the performance of the facilities when calibrating measurement instruments for radon. Fifteen calibration facilities from 13 different European countries participated. They represented different levels in the metrological hierarchy: national metrology institutes and designated institutes, national authorities for radiation protection and participants from universities. The interlaboratory comparison was conducted by the German Federal Office for Radiation Protection (BfS) and took place from 2018 to 2020. Participants were requested to measure radon in atmospheres of their own facilities according to their own procedures and requirements for metrological traceability. A measurement device with suitable properties was used to determine the comparison values. The results of the comparison showed that the radon activity concentrations that were determined by European calibration facilities complying with metrological traceability requirements were consistent with each other and had common mean values. The deviations from these values were normally distributed. The range of variation of the common mean value was a measure of the degree of agreement between the participants. For exposures above 1000 Bq/m3, the variation was about 4% for a level of confidence of approximately 95% (k=2). For lower exposure levels, the variation increased to about 6%.


Assuntos
Poluentes Radioativos do Ar , Monitoramento de Radiação , Proteção Radiológica , Radônio , Poluentes Radioativos do Ar/análise , Calibragem , Humanos , Radônio/análise
3.
Appl Radiat Isot ; 126: 273-278, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28314506

RESUMO

The results of the three years European Metrology Research Programme's (EMRP) joint research project 'Metrology for processing materials with high natural radioactivity' (MetroNORM) are presented. In this project, metrologically sound novel instruments and procedures for laboratory and in-situ NORM activity measurements have been developed. Additionally, standard reference materials and sources for traceable calibration and improved decay data of natural radionuclides have been established.