Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Contact Dermatitis ; 91(1): 22-29, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38515234

RESUMO

BACKGROUND: During the COVID-19 pandemic, increased hand hygiene practices were implemented. Impaired skin health on the hands among healthcare workers has been reported previously. Knowledge of how worker in other occupations have been affected is scarce. OBJECTIVES: To investigate self-reported hand water-, and soap exposure and use of hand disinfectants, and hand eczema (HE) in frontline workers outside the hospital setting and in IT personnel during the COVID-19 pandemic. METHODS: In this cross-sectional study, a questionnaire was sent out between 1 March and 30 April in 2021, to 6060 randomly selected individuals representing six occupational groups. RESULTS: A significant increase in water exposure and hand disinfectant use was shown: Relative position (RP) 19; 95% confidence interval (CI) 0.17-0.21 and RP = 0.38: 95% CI 0.36-0.41, respectively. Newly debuted HE was reported by 7.4% of the population, more frequently among frontline workers (8.6%) compared to IT personnel (4.9%). CONCLUSIONS: Water and soap exposure and use of hand disinfectants increased during COVID-19 pandemic, which may increase the risk of hand eczema. This highlights the importance of communication and implementation of preventive measures to protect the skin barrier also in occupations other than healthcare workers.


Assuntos
COVID-19 , Dermatite Ocupacional , Eczema , Dermatoses da Mão , Desinfecção das Mãos , Autorrelato , Sabões , Humanos , COVID-19/prevenção & controle , COVID-19/epidemiologia , Estudos Transversais , Sabões/efeitos adversos , Masculino , Dermatoses da Mão/epidemiologia , Dermatoses da Mão/etiologia , Feminino , Adulto , Dermatite Ocupacional/epidemiologia , Dermatite Ocupacional/etiologia , Eczema/epidemiologia , Pessoa de Meia-Idade , Água , Exposição Ocupacional/efeitos adversos , Pessoal de Saúde/estatística & dados numéricos , SARS-CoV-2 , Desinfetantes/efeitos adversos , Inquéritos e Questionários , Higiene das Mãos
2.
Br J Dermatol ; 188(2): 278-287, 2023 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-36637098

RESUMO

BACKGROUND: Cobalt (Co) causes allergic contact dermatitis (ACD) and the emerging use of Co nanoparticles (CoNPs) warrants gaining further insight into its potential to elicit ACD in sensitized individuals. OBJECTIVES: The aims of the study were to clarify to what extent CoNPs may elicit ACD responses in participants with Co contact allergy, and to evaluate whether the nanoparticles cause a distinct immune response compared with cobalt chloride (CoCl2) in the skin reactions. METHODS: Fourteen individuals with Co contact allergy were exposed to CoNPs, CoCl2, a Co-containing hard-metal disc (positive control), and an empty test chamber (negative control) by patch testing. Allergic responses were evaluated clinically by a dermatologist at Days 2, 4 and 7. At Day 2, patch-test chambers were removed, and remaining test-substance and skin-wipe samples were collected for inductive-coupled plasma mass spectrometry (ICP-MS) analysis. Additionally, skin biopsies were taken from patch-test reactions at Day 4 for quantitative real-time polymerase chain reaction analysis, histopathology and ICP-MS analysis of Co skin penetration. RESULTS: Patch testing with CoNPs elicited allergic reactions in Co-sensitized individuals. At all timepoints, clinical assessment revealed significantly lower frequencies of positive patch-test reactions to CoNPs compared with CoCl2 or to the positive control. CoNPs elicited comparable immune responses to CoCl2. Chemical analysis of Co residues in patch-test filters, and on skin, shows lower doses for CoNPs compared with CoCl2. CONCLUSIONS: CoNPs potently elicit immune responses in Co-sensitized individuals. Even though patch testing with CoNPs resulted in a lower skin dose than CoCl2, identical immunological profiles were present. Further research is needed to identify the potential harm of CoNPs to human health.


Assuntos
Dermatite Alérgica de Contato , Nanopartículas , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Cobalto/efeitos adversos , Cobalto/química , Pele , Testes do Emplastro , Alérgenos
3.
Int J Nanomedicine ; 16: 5895-5908, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34475755

RESUMO

INTRODUCTION: Gold nanoparticles (AuNPs) have the potential to be used in various biomedical applications, partly due to the inertness and stability of gold. Upon intravenous injection, the NPs interact with the mononuclear phagocyte system, first with monocytes in the blood and then with macrophages in tissue. The NP-macrophage interaction will likely affect the stability of the AuNPs, but this is seldom analyzed. This study aimed to elucidate the role of macrophages in the biodissolution of AuNPs and underlying mechanisms. METHODS: With an in vitro dissolution assay, we used inductively coupled plasma mass spectrometry to quantitatively compare the dissolution of 5 and 20 nm AuNPs coated with citrate or PEG in cell medium alone or in the presence of THP1-derived macrophages at 24 hours. In addition, we analyzed the cell dose, compared extra- and intracellular dissolution, and explored the possible role of reactive nitrogen species. RESULTS: The results showed a higher cellular dose of the citrate-coated AuNPs, but dissolution was mainly evident for those sized 5 nm, irrespective of coating. The macrophages clearly assisted the dissolution, which was approximately fivefold higher in the presence of macrophages. The dissolution, however, appeared to take place mainly extracellularly. Acellular experiments demonstrated that peroxynitrite can initiate oxidation of gold, but a ligand is required to keep the gold ions in solution. CONCLUSION: This study suggests extracellular dissolution of AuNPs in the presence of macrophages, likely with the contribution of the release of reactive nitrogen species, and provides new insight into the fate of AuNPs in the body.


Assuntos
Ouro , Nanopartículas Metálicas , Humanos , Macrófagos , Sistema Fagocitário Mononuclear , Espécies Reativas de Nitrogênio
4.
Regul Toxicol Pharmacol ; 115: 104693, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32505642

RESUMO

How metals permeate skin is poorly understood. Risk assessments tend to take default approaches to account for the dermal route, often using numbers of questionable relevance. Moreover, simultaneous exposure to multiple metals may affect the permeation of individual metals. To investigate this, we developed an experimental setup where receptor medium circulates directly from a conventional diffusion cell for in vitro skin absorption into an inductively coupled plasma mass spectrometer (ICP-MS), enabling continuous measurement of metal concentration. Full-thickness piglet skin was used as diffusion barrier, artificial sweat as donor medium and phosphate buffered saline as receptor medium. Percutaneous absorption from donor medium containing 2 mmol/L of nickel, cobalt, or chromium or all three combined was monitored for 2 h. Metals retained in skin were quantified post-exposure. Percutaneous absorption of nickel was faster in single than in combined exposure; for cobalt and chromium no such difference was apparent. Similar amounts of the three metals were retained in skin after single exposure, and retention was consistently higher for each metal after combined exposure. This study provides proof-of-concept for a method that reliably detects concentration changes in physiologically relevant medium. It may shed light on skin absorption and permeation kinetics of metals and risks associated with metal exposure.


Assuntos
Metais Pesados/metabolismo , Pele/metabolismo , Animais , Difusão , Técnicas In Vitro , Metais Pesados/análise , Pele/química , Absorção Cutânea , Suínos
5.
Ann Work Expo Health ; 64(9): 970-981, 2020 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-32566942

RESUMO

OBJECTIVES: The most pronounced occupational exposure routes for lead (Pb) are inhalation and gastrointestinal uptake mainly through hand-to-mouth behaviour. Skin absorption has been demonstrated for organic Pb compounds, but less is known about inorganic Pb species. Several legislative bodies in Europe are currently proposing lowering biological exposure limit values and air exposure limits due to new evidence on cardiovascular effects at very low blood Pb levels. In light of this, all exposure routes in occupational settings should be revisited to evaluate how to lower the overall exposure to Pb. METHODS: The aim of the study was to investigate the possible exposure routes in workers operating computer numerical control-machines in a brass foundry and specifically to understand if metal cutting fluids (MCFs) used by the workers could lead to skin absorption of Pb. The different bronze alloys at the facility may contain up to 20% Pb. After obtaining written informed consent from the workers (n = 7), blood, skin wipes, and personal air samples were collected. In addition, MCFs used on the day of exposure measurements were collected for in vitro skin absorption studies using stillborn piglet skin mounted in static Franz diffusion cells (n = 48). All samples were analysed for Pb content using inductively coupled plasma mass spectrometry. RESULTS: Pb air concentration (<0.1-3.4 µg m-3) was well below the Swedish occupational exposure limit value. Blood Pb was in the range of <0.72-33 µg dl-1, and Pb on skin surfaces, after performing normal work tasks during 2 h, was in the range of 0.2-48 µg cm-2. Using the MCFs in diffusion cells showed that skin absorption had occurred at very low doses, and that up to 10% of the Pb content was present in the skin after 24 h exposure. Using these results in the US EPA adult lead model, we could estimate a contribution to blood Pb from the three exposure routes; where hand-to-mouth behaviour yielded the highest contribution (16 µg Pb dl-1 blood), followed by skin absorption (3.3-6.3 µg Pb dl-1 blood) and inhalation (2.0 µg Pb dl-1 blood). CONCLUSIONS: This case study shows that MCF may lead to skin absorption of inorganic Pb and contribute to a systemic dose (quasi-steady state). Furthermore, even though good hand hygienic measures were in place, the workers' skin exposure to Pb is in all likelihood an important contributor in elevating blood Pb levels. Skin exposure should thus be monitored routinely in workers at facilities handling Pb, to help reducing unnecessary occupational exposure.


Assuntos
Cobre , Chumbo , Exposição Ocupacional , Zinco , Adulto , Animais , Carga Corporal (Radioterapia) , Monitoramento Ambiental , Europa (Continente) , Humanos , Metalurgia , Exposição Ocupacional/análise , Suécia , Suínos
6.
ACS Appl Bio Mater ; 2(3): 1006-1016, 2019 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-35021391

RESUMO

Gold nanoparticles (AuNPs) are readily functionalized and considered biocompatible making them useful in a wide range of applications. Upon human exposure, AuNPs will to a high extent reside in macrophages, cells that are designed to digest foreign materials. To better understand the fate of AuNPs in the human body, their possible dissolution needs to be explored. In this study, we tested the hypothesis that macrophages, and especially stimulated macrophages, can impact the dissolution of AuNPs in a size-dependent manner. We developed an in vitro method to compare the dissolution of citrate coated 5 and 50 nm-sized AuNPs, in terms of released gold ions as measured by inductive coupled mass spectrometry (ICP-MS), in (i) cell medium (alone) (ii) in medium with macrophages present and (iii) in medium with lipopolysaccharide (LPS) triggered macrophages (simulating inflammatory conditions). We found an evident, time-dependent dissolution of AuNPs in cell medium, corresponding to 3% and 0.6% of the added amounts of 5 and 50 nm AuNPs, respectively, after 1 week (168 h) of incubation. The dissolution of 5 nm AuNPs was further increased to 4% in the presence of macrophages and, most strikingly, 14% was dissolved in case of LPS-triggering. In contrast, only a minor increase was observed for 50 nm AuNPs after 1 week in the presence of LPS-triggered macrophages compared to medium alone. Dissolution experiments in the absence of cells highlighted the importance of biomolecules. Our findings thus show dissolution of citrate coated AuNPs that is dependent on size, presence of macrophages, and their inflammatory state. These findings have implications for understanding the transformation/dissolution and fate of AuNPs.

7.
Contact Dermatitis ; 80(2): 86-93, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30370609

RESUMO

BACKGROUND: Knowledge about the skin deposition and penetration of nickel into the stratum corneum (SC) after short contact with metallic items is limited. OBJECTIVE: To quantify nickel skin deposition and penetration into the SC after short contact with metallic nickel. METHODS: Sixteen nickel-allergic participants and 10 controls were exposed to 3 pure nickel discs and 1 aluminium disc on each volar forearm for 3 × 10 minutes. Before exposure, 1 forearm was irritated with 0.5% sodium lauryl sulfate under 24-hour occlusion. Immediately, as well as 24 and 72 hours after metallic disc exposure, outer SC layers were removed with adhesive tapes and the nickel content was measured. RESULTS: Nickel deposition and SC penetration capable of eliciting allergic nickel dermatitis were found immediately and after 24 hours. Significantly higher nickel amounts were found on normal skin and in the SC of nickel-allergic participants than in controls both immediately and after 24 hours, and on irritated skin immediately after exposure. CONCLUSIONS: Nickel deposition and SC penetration is considerable after nickel skin exposure of 3 × 10 minutes. Combined with the allergic responses resulting from the same exposures reported previously, this study highlights that short skin exposure to nickel-releasing items may cause allergic nickel dermatitis.


Assuntos
Quelantes/metabolismo , Dermatite Alérgica de Contato/metabolismo , Níquel/metabolismo , Absorção Cutânea , Pele/metabolismo , Adulto , Alumínio/metabolismo , Quelantes/efeitos adversos , Dermatite Alérgica de Contato/etiologia , Dermatite Alérgica de Contato/genética , Dermatite Atópica/genética , Feminino , Proteínas Filagrinas , Dermatoses da Mão/genética , Humanos , Proteínas de Filamentos Intermediários/genética , Masculino , Pessoa de Meia-Idade , Mutação , Níquel/efeitos adversos
8.
Occup Environ Med ; 75(11): 837-842, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30173144

RESUMO

OBJECTIVES: Cobalt (Co) exposure is associated with adverse health effects including skin sensitisation, asthma and interstitial lung fibrosis. Exposure to Co in industrial settings is often assessed using air samples or biomonitoring in urine. Skin exposure is rarely measured. Aim of this study was to quantify and compare the importance of Co skin exposure and respiratory exposure in determining urinary Co concentrations. METHODS: Co skin exposure was measured in 76 hard metal workers by acid wipe sampling before and at the end of work shifts. Spot urine was collected during a 24-hour period from the start of a shift. Respiratory exposure was measured by personal inhalable dust sampling during a shift in 30 workers. Co was analysed by inductively coupled plasma mass spectrometry. RESULTS: Quantile regression modelling showed that a doubling of Co on skin before or at the end of shift increased the median urinary concentration of Co by 70% (p<0.001) or 32% (p<0.001), respectively. A doubling of Co in air increased median urinary Co by 38% (p<0.001). Co skin exposures were still significantly associated with urinary Co after excluding a group of workers with high respiratory exposure (33%, p=0.021 and 17%, p=0.002). CONCLUSIONS: The results indicate an association between Co skin exposure and urinary Co concentrations. This should be considered when using urinary Co as a biomarker of exposure.


Assuntos
Poluentes Ocupacionais do Ar/análise , Cobalto/análise , Exposição por Inalação/análise , Metalurgia , Exposição Ocupacional/efeitos adversos , Pele/química , Adulto , Idoso , Poluentes Ocupacionais do Ar/urina , Cobalto/urina , Monitoramento Ambiental/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Adulto Jovem
9.
Contact Dermatitis ; 79(4): 226-231, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30009432

RESUMO

BACKGROUND: It is well known that hard metal workers have historically been affected by contact allergy to cobalt. Knowledge is sparse about occupational skin exposure to cobalt, in terms of skin doses and sources of exposure, which could be used to improve protection of workers. OBJECTIVES: To improve knowledge about skin doses and sources of skin exposure to cobalt within hard metal production, thereby facilitating better protection of workers. METHODS: Forty workers were sampled on the index finger by acid wipe sampling after 2 hours of work. The samples were analysed with inductively coupled plasma mass spectrometry. Cobalt spot testing was performed in the work environment. RESULTS: The highest skin doses were found among raw material workers. Skin doses among other production workers were also significant. Most office workers had low, but measurable, levels of cobalt on the skin. Glove use varied between workers. Cobalt was found on production equipment, on items in the canteen area, and on handles and buttons throughout the company. CONCLUSIONS: Cobalt skin doses were prominent, and originated from contact with raw materials, sintered materials, and contaminated surfaces. Cobalt was present on surfaces outside production areas. Companies need to identify and reduce skin exposure for protection of workers.


Assuntos
Ligas , Cobalto/análise , Metalurgia , Exposição Ocupacional/análise , Pele , Tungstênio , Adulto , Cobalto/efeitos adversos , Dermatite Alérgica de Contato/etiologia , Dermatite Ocupacional/etiologia , Feminino , Luvas Protetoras/estatística & dados numéricos , Humanos , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Adulto Jovem
10.
Contact Dermatitis ; 77(1): 17-24, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28449188

RESUMO

BACKGROUND: Nickel, cobalt and chromium are frequent skin sensitizers. Skin exposure results in eczema in sensitized individuals, the risk being related to the skin dose. OBJECTIVES: To develop a self-sampling method for quantification of skin exposure to metals, to validate the method, and to assess its feasibility. METHODS: Defined metal doses (0.01-5 µg) were applied to the fingers of 5 participants. Skin areas (2 cm2 ) were sampled with 1% HNO3 , either as 0.1 ml on a swab, or as 0.5 ml on a wipe. Furthermore, 17 participants performed self-sampling by swab after 2 h of leisure activity. Samples were extracted in 1% HNO3 and analysed by inductively coupled plasma mass spectrometry. RESULTS: The sampling efficiency by swab was 46%, as compared with 93% for acid wipe sampling, for all tested doses. Most metal from the skin dose was detected in the first swab (33-43%). Despite lower sampling efficiency by swab, skin doses of metals following 2 h of leisure activity without hand washing were quantified in all participants, and ranged from 0.0016 to 0.15 µg/cm2 , from 0.00014 to -0.0020 µg/cm2 and from 0.00048 to -0.027 µg/cm2 for nickel, cobalt, and chromium, respectively. CONCLUSIONS: The results indicate a future potential of skin sampling by swab to detect and monitor metals on skin by self-sampling. This will contribute to better knowledge of metal skin exposure among dermatitis patients, workers, and the general population.


Assuntos
Dermatite Alérgica de Contato/diagnóstico , Espectrometria de Massas/métodos , Metais/análise , Pele/química , Dedos , Humanos , Atividades de Lazer , Exposição Ocupacional/análise , Autocuidado
11.
Regul Toxicol Pharmacol ; 81: 381-386, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27664322

RESUMO

Metal release from materials immersed in artificial sweat can function as a measure of potential skin exposure. Several artificial sweat models exist that, to various degree, mimic realistic conditions. Study objective was to evaluate metal release from previously examined and well characterized materials in two different artificial sweat solutions; a comprehensive sweat model intended for use within research, based on the composition of human sweat; and the artificial sweat, EN1811, intended for testing compliance with the nickel restriction in REACH. The aim was to better understand whether there are advantages using either of the sweat solutions in bio-elution testing of materials. Metal release in two different artificial sweat solutions was compared for discs of a white gold alloy and two hard metals, and a rock drilling insert of tungsten carbide at 1 h, 24 h, 1 week and 1 month. The released amount of metal was analysed by means of inductively coupled plasma mass spectrometry. Similar levels of released metals were measured from test materials in the two different artificial sweat solutions. For purposes in relation to legislations, it was concluded that a metal release test using a simple artificial sweat composition may provide results that sufficiently indicate the degree of metal release at skin contact.


Assuntos
Materiais Biomiméticos/química , Metais Pesados/química , Suor/química , Humanos , Soluções
12.
Contact Dermatitis ; 75(6): 370-376, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27633504

RESUMO

BACKGROUND: It is not fully understood where and how people are exposed to sensitizing metals. Much can be learnt from studying occupational settings where metals are handled. OBJECTIVES: To quantify cobalt (Co), chromium (Cr) and nickel (Ni) exposure on the skin and in the air, and urine levels, in dental technicians working with tools and alloys that may result in skin and respiratory exposure. METHODS: The metal skin dose was quantified with acid wipe sampling in dental technicians (n = 13). Air exposure was monitored by personal air sampling. Spot urine samples were collected for 24 h. Metals were analysed with inductively coupled plasma mass spectrometry. RESULTS: Before work, Co was detected on the skin of 10 participants (0.00025-0.0039 µg/cm2 ), and Cr (0.00051-0.011 µg/cm2 ) and Ni (0.0062-0.15 µg/cm2 ) on the skin of all participants. After a 2-h period without hand washing, CoCr-exposed participants had more Co on the skin (p = 0.004) than non-CoCr-exposed participants. Co was found in 10 air samples (0.22-155 µg/m3 ), Cr in nine (0.43-71 µg/m3 ), and Ni in four (0.48-3.7 µg/m3 ). Metal urine concentrations were considered to be normal. CONCLUSIONS: Dental technicians were exposed to Co, Cr and Ni on the skin and through the air, which was not reflected in the urine concentrations in this study. Cobalt skin doses may potentially elicit allergic contact dermatitis and cause sensitization.


Assuntos
Cromo/análise , Cobalto/análise , Técnicos em Prótese Dentária , Poluentes Ambientais/análise , Níquel/análise , Exposição Ocupacional/estatística & dados numéricos , Adulto , Cromo/efeitos adversos , Cromo/urina , Cobalto/efeitos adversos , Cobalto/urina , Monitoramento Ambiental , Poluentes Ambientais/efeitos adversos , Poluentes Ambientais/urina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Níquel/efeitos adversos , Níquel/urina , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/análise , Pele/química , Suécia
13.
Artigo em Inglês | MEDLINE | ID: mdl-27274222

RESUMO

Tobacco contains cadmium, and this metal has been attributed a causative role in pulmonary emphysema among smokers, although extracellular cadmium has not to date been quantified in the bronchoalveolar space of tobacco smokers with or without COPD. We determined whether cadmium is enhanced in the bronchoalveolar space of long-term tobacco smokers with or without COPD in vivo, its association with inflammation, and its effect on chemokine release in macrophage-like cells in vitro. Bronchoalveolar lavage (BAL), sputum, and blood samples were collected from current, long-term smokers with and without COPD and from healthy nonsmokers. Cadmium concentrations were determined in cell-free BAL fluid using inductively coupled plasma mass spectrometry. Blood monocyte-derived macrophages were exposed to cadmium chloride in vitro. Depending upon the type of sample, molecular markers of inflammation were quantified either as protein (enzyme-linked immunosorbent assay) or as mRNA (real-time polymerase chain reaction). Cadmium concentrations were markedly increased in cell-free BAL fluid of smokers compared to that of nonsmokers (n=19-29; P<0.001), irrespective of COPD. In these smokers, the measured cadmium displayed positive correlations with macrophage TNF-α mRNA in BAL, neutrophil and CD8(+) cell concentrations in blood, and finally with IL-6, IL-8, and MMP-9 protein in sputum (n=10-20; P<0.05). The cadmium chloride exposure caused a concentration-dependent increase in extracellular IL-8 protein in monocyte-derived macrophages in vitro. In conclusion, extracellular cadmium is enhanced in the bronchoalveolar space of long-term smokers and displays pro-inflammatory features. Its pathogenic role in tobacco-induced disease deserves further evaluation.


Assuntos
Brônquios/química , Cádmio/análise , Espaço Extracelular/química , Inflamação/complicações , Alvéolos Pulmonares/química , Doença Pulmonar Obstrutiva Crônica/complicações , Fumar/efeitos adversos , Adulto , Idoso , Líquido da Lavagem Broncoalveolar/química , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Escarro/química , Adulto Jovem
14.
Contact Dermatitis ; 74(6): 353-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27133625

RESUMO

BACKGROUND: Laptop computers may release nickel and cobalt when they come into contact with skin. Few computer brands have been studied. OBJECTIVES: To evaluate nickel and cobalt release from laptop computers belonging to several brands by using spot tests, and to quantify the release from one new computer by using artificial sweat solution. METHODS: Nickel and cobalt spot tests were used on the lid and wrist supports of 31 laptop computers representing five brands. The same surfaces were tested on all computers. In addition, one new computer was bought and dismantled for release tests in artificial sweat according to the standard method described in EN1811. RESULTS: Thirty-nine per cent of the laptop computers were nickel spot test-positive, and 6% were positive for cobalt. The nickel on the surface could be worn off by consecutive spot testing of the same surface. The release test in artificial sweat of one computer showed that nickel and cobalt were released, although in low concentrations. CONCLUSIONS: As they constitute a potential source of skin exposure to metals, laptop computers should qualify as objects to be included within the restriction of nickel in REACH, following the definition of 'prolonged skin contact'. Skin contact resulting from laptop use may contribute to an accumulated skin dose of nickel that can be problematic for sensitized individuals.


Assuntos
Cobalto/análise , Computadores , Níquel/análise , Cobalto/efeitos adversos , Qualidade de Produtos para o Consumidor/legislação & jurisprudência , Dermatite Alérgica de Contato/etiologia , Europa (Continente) , Humanos , Níquel/efeitos adversos , Risco , Suor
15.
Contact Dermatitis ; 74(2): 105-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26563947

RESUMO

BACKGROUND: Cobalt is a strong skin sensitizer (grade 5 of 5 in the guinea-pig maximization test) that is used in various industrial and consumer applications. To prevent sensitization to cobalt and elicitation of allergic cobalt dermatitis, information about the elicitation threshold level of cobalt is important. OBJECTIVE: To identify the dermatitis elicitation threshold levels in cobalt-allergic individuals. MATERIALS AND METHODS: Published patch test dose-response studies were reviewed to determine the elicitation dose (ED) levels in dermatitis patients with a previous positive patch test reaction to cobalt. A logistic dose-response model was applied to data collected from the published literature to estimate ED values. The 95% confidence interval (CI) for the ratio of mean doses that can elicit a reaction in 10% (ED(10)) of a population was calculated with Fieller's method. RESULTS: On the basis of five included studies, the ED10 values of aqueous cobalt chloride ranged between 0.0663 and 1.95 µg cobalt/cm(2), corresponding to 30.8-259 ppm. CONCLUSIONS: Our analysis provides an overview of the doses of cobalt that are required to elicit allergic cobalt contactdermatitis in sensitized individuals, and thereby the basis for future prevention of cobalt allergy.


Assuntos
Cobalto/administração & dosagem , Cobalto/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Testes do Emplastro/estatística & dados numéricos , Testes de Irritação da Pele/estatística & dados numéricos , Humanos , Testes Cutâneos/métodos
16.
Contact Dermatitis ; 73(4): 222-30, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26086991

RESUMO

BACKGROUND: The existing EU nickel restriction does not sufficiently protect the population from skin exposure to nickel. Better understanding is needed of the extent to which short and frequent contact with nickel-releasing items contributes to nickel deposition on skin. OBJECTIVES: To quantify nickel skin exposure from short and frequent contact with nickel-releasing materials. MATERIALS/METHODS: Sequences of short contact events were assessed in (i) touch tests for measurement of nickel skin dose, (ii) wipe tests to similarly quantify the nickel release during a touch, and (iii) immersion tests in artificial sweat, for nickel-containing alloys and pure nickel. RESULTS: Nickel skin doses from a single touch were 0.024-4.7 µg/cm(2) for all materials. Touching or wiping five untouched surfaces resulted in more accumulated nickel than five repeated touches of the same surface. The released amounts of nickel were generally lower at immersion, but increased with the number of repeated immersion periods. CONCLUSIONS: Nickel skin doses were quantified after one single touch for all study materials. Touch tests, and potentially wipe tests as a proxy for skin dose measurements, are preferred to immersion tests for the assessment of short and frequent skin contact with nickel.


Assuntos
Dermatite Alérgica de Contato/etiologia , Níquel/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Humanos , Níquel/administração & dosagem , Suor
18.
Contact Dermatitis ; 70(6): 361-8, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24617983

RESUMO

BACKGROUND: Many daily contacts with metallic items are short and repetitive, and result in metal release; material, sweat, friction and wear may all be important. OBJECTIVES: To study cobalt release and skin deposition as a result of many short and repetitive contacts with two cobalt-containing materials. MATERIALS/METHODS: Study participants (n = 5) handled two types of hard metal disc (Co 6% and Co 15% Cr 0.6%) for 30 min. Deposited cobalt skin doses were measured with acid wipe sampling and chemical analysis. Cobalt release from the hard metal discs in artificial sweat was measured under conditions simulating those present during the handling of discs. RESULTS: Average cobalt skin doses from discs containing 6% Co and 15% Co 0.6% Cr were 1.1 µg/cm(2) [standard deviation (SD) 0.4 µg/cm(2) ] and 0.7 µg/cm(2) (SD 0.5 µg/cm(2) ), respectively. More cobalt was released from hard metal discs containing 6% Co [11.4 µg/cm(2) (SD 1.2 µg/cm(2) )] than from discs containing 15% Co 0.6% Cr [4.8 µg/cm(2) (SD 0.6 µg/cm(2) )]. 10% to 15% of the potentially available cobalt was deposited on the skin during handling. CONCLUSIONS: It is likely that the cobalt deposited as a result of short and repetitive contact with hard metals may cause harm. Research regarding cobalt exposure, metal release and the deposition of skin-sensitizing metals resulting from short and repetitive contact is needed for a better understanding of the allergy risk.


Assuntos
Ligas/análise , Cobalto/análise , Exposição Ambiental/análise , Pele/química , Tungstênio/análise , Humanos , Suor/química
19.
Contact Dermatitis ; 69(5): 280-7, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23848375

RESUMO

BACKGROUND: A spot test was recently developed for easy and rapid testing to detect whether cobalt is available on surfaces in contact with skin. OBJECTIVES: To explore the potential use of the cobalt spot test as a tool for skin dose assessment, and to verify the sensitivity under laboratory conditions. METHODS: A cobalt dilution series (cobalt standards mixed with cobalt spot test reagent solution) was prepared to determine the threshold for colour change. Defined doses of cobalt were applied to the fingers of 5 volunteers. Acid wipe sampling was used to measure the recovery of applied cobalt skin doses on one hand, and cobalt-exposed areas on the other hand were spot tested. RESULTS: A weak colour gradient was visible from approximately 1 to 1.5 µg cobalt/ml in the dilution series. For a skin dose of 0.125 µg cobalt/cm(2) , 80% of the cobalt dose was collected by acid wipe sampling. Spot tests gave positive results in all cases (n = 5). CONCLUSIONS: The cobalt spot test can be used to show cobalt on the skin. More experience is needed to understand and describe the most suitable test conditions.


Assuntos
Alérgenos/análise , Cobalto/análise , Testes do Emplastro/métodos , Pele/química , Alérgenos/administração & dosagem , Cobalto/administração & dosagem , Dedos , Humanos
20.
Contact Dermatitis ; 68(6): 323-30, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23692032

RESUMO

BACKGROUND: Nickel-plated steel coins have recently been introduced in the United Kingdom. OBJECTIVES: To compare the performance and allergy risk of the new nickel-plated coins (five and ten pence) with those of the cupro-nickel coins being replaced. MATERIALS AND METHODS: Coin handling studies with assessment of skin exposure and metal release in artificial sweat were performed. Six volunteers participated. RESULTS: The amount of nickel deposited onto skin during the handling of nickel-plated coins for 1 hr was 7.5 µg/cm(2) , four times higher than that from cupro-nickel coins. The nickel content in the oxidized surface of nickel-plated coins was higher, explaining the higher skin dose. Initial nickel release rates were 10-27 times higher than 1-week rates, emphasizing that brief and repeated contact results in significant nickel exposure. CONCLUSIONS: Nickel-plated coins deposit higher levels of nickel onto skin than cupro-nickel coins, and hence pose an increased allergy risk. One-week release in artificial sweat is not suitable for determining the risk of handling items with high nickel release that come into short, repeated contact with the skin. The nickel skin dose is recommended for risk assessment. UK citizens are now, because of this change in coinage, unnecessarily exposed to higher levels of nickel on the skin. This is of public health concern.


Assuntos
Dermatite de Contato/etiologia , Exposição Ambiental/análise , Poluentes Ambientais/efeitos adversos , Níquel/efeitos adversos , Numismática , Cobre/efeitos adversos , Cobre/análise , Dermatite Alérgica de Contato/etiologia , Exposição Ambiental/efeitos adversos , Poluentes Ambientais/análise , Humanos , Microscopia Eletrônica de Varredura , Níquel/análise , Espectroscopia Fotoeletrônica , Medição de Risco , Espectrofotometria Atômica , Aço , Suor/química , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA