Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 206
Filtrar
1.
Ultrasound Obstet Gynecol ; 62(6): 891-903, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37606287

RESUMO

OBJECTIVE: To assess the impact of photoacoustic imaging (PAI) on the assessment of ovarian/adnexal lesion(s) of different risk categories using the sonographic ovarian-adnexal imaging-reporting-data system (O-RADS) in women undergoing planned oophorectomy. METHOD: This prospective study enrolled women with ovarian/adnexal lesion(s) suggestive of malignancy referred for oophorectomy. Participants underwent clinical ultrasound (US) examination followed by coregistered US and PAI prior to oophorectomy. Each ovarian/adnexal lesion was graded by two radiologists using the US O-RADS scale. PAI was used to compute relative total hemoglobin concentration (rHbT) and blood oxygenation saturation (%sO2 ) colormaps in the region of interest. Lesions were categorized by histopathology into malignant ovarian/adnexal lesion, malignant Fallopian tube only and several benign categories, in order to assess the impact of incorporating PAI in the assessment of risk of malignancy with O-RADS. Malignant and benign histologic groups were compared with respect to rHbT and %sO2 and logistic regression models were developed based on tumor marker CA125 alone, US-based O-RADS alone, PAI-based rHbT with %sO2 , and the combination of CA125, O-RADS, rHbT and %sO2. Areas under the receiver-operating-characteristics curve (AUC) were used to compare the diagnostic performance of the models. RESULTS: There were 93 lesions identified on imaging among 68 women (mean age, 52 (range, 21-79) years). Surgical pathology revealed 14 patients with malignant ovarian/adnexal lesion, two with malignant Fallopian tube only and 52 with benign findings. rHbT was significantly higher in malignant compared with benign lesions. %sO2 was lower in malignant lesions, but the difference was not statistically significant for all benign categories. Feature analysis revealed that rHbT, CA125, O-RADS and %sO2 were the most important predictors of malignancy. Logistic regression models revealed an AUC of 0.789 (95% CI, 0.626-0.953) for CA125 alone, AUC of 0.857 (95% CI, 0.733-0.981) for O-RADS only, AUC of 0.883 (95% CI, 0.760-1) for CA125 and O-RADS and an AUC of 0.900 (95% CI, 0.815-0.985) for rHbT and %sO2 in the prediction of malignancy. A model utilizing all four predictors (CA125, O-RADS, rHbT and %sO2 ) achieved superior performance, with an AUC of 0.970 (95% CI, 0.932-1), sensitivity of 100% and specificity of 82%. CONCLUSIONS: Incorporating the additional information provided by PAI-derived rHbT and %sO2 improves significantly the performance of US-based O-RADS in the diagnosis of adnexal lesions. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Doenças dos Anexos , Neoplasias Ovarianas , Técnicas Fotoacústicas , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias Ovarianas/patologia , Estudos Prospectivos , Ultrassonografia/métodos , Medição de Risco , Antígeno Ca-125 , Doenças dos Anexos/patologia , Sensibilidade e Especificidade , Estudos Retrospectivos
2.
Acta Anaesthesiol Scand ; 48(1): 117-22, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14674982

RESUMO

In August 1908 Karl August Bier, Professor of Surgery in Berlin, described a new method of producing analgesia of a limb which he named 'vein anesthesia'. Bier first presented his new method of intravenous regional anesthesia (IVRA) at the 37th Congress of the German Surgical Society on 22 April, 1908, only 10 years after his significant communication on spinal anesthesia (1). His method, which now bears his name, consisted of occluding the circulation in a segment of the arm with two tourniquets and then injecting a dilute local anesthetic through a venous cut-down in the isolated segment. Bier had the good fortune to use procaine, the first safe injectable local anesthetic that had been synthesized by Einhorn in 1904.


Assuntos
Anestesia por Condução/história , Anestesia Intravenosa/história , Adjuvantes Anestésicos , Alemanha , História do Século XX , Torniquetes
4.
Radiol Clin North Am ; 39(3): 465-83, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11506088

RESUMO

In summary, musculoskeletal sonography is a rapidly growing field of interest around the world. Outside of America, it is often the first and definitive imaging modality fordisorders of the musculoskeletal system. Musculoskeletal ultrasound offers rapid, inexpensive, real-time examination of the structures of interest with easy comparison to the contralateral side. Principles of one area of musculoskeletal sonography easily generalize to other areas.


Assuntos
Doenças Musculoesqueléticas/diagnóstico por imagem , Ultrassonografia/métodos , Humanos , Artropatias/diagnóstico por imagem , Ombro/anatomia & histologia , Ombro/diagnóstico por imagem
5.
J Shoulder Elbow Surg ; 10(3): 199-203, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11408898

RESUMO

The purpose of this study was to examine longitudinally the natural history of asymptomatic rotator cuff tears over a 5-year period and to assess the risk for development of symptoms and tear progression. Since 1985 through the present, bilateral sonograms were done on all patients. A review of consecutive sonograms done from 1989 to 1994 revealed 58 potential patients with unilateral symptoms who had contralateral asymptomatic rotator cuff tears. Of these 58 patients, 45 (22 men, 23 women) responded to a comprehensive questionnaire and 23 additionally returned for examination and repeat sonographic evaluation. The questionnaire was based on the American Shoulder and Elbow Surgeons score and included several outcome-based questions. A physical examination was performed in a standardized fashion along American Shoulder and Elbow Surgeons guidelines. Repeat high-resolution sonograms were performed by a single experienced radiologist. Primary and repeat sonograms were then reassessed for tear size and location by two independent experienced radiologists blinded to the clinical data results. Twenty-three (51%) of the previously asymptomatic patients became symptomatic over a mean of 2.8 years. The average Activities of Daily Living score for those remaining asymptomatic was 28.5 of 30 and for those becoming newly symptomatic, 22.9 of 30 (P <.5). The mean visual analog pain score (1 = no pain) for those remaining asymptomatic was 1.1 and for the newly symptomatic patients, 4.0. Of the 23 patients who returned for ultrasound, 9 were asymptomatic and 14 symptomatic. Only 2 of the 9 patients remaining asymptomatic had progression of their tears. Overall, 9 of 23 patients had tear progression. No patient had a decrease in the size of the tear. Our results demonstrate that symptoms can develop in patients with previously asymptomatic rotator cuff tears when seen in the context of a contralateral symptomatic tear. Development of symptoms was associated with a significant increase in pain and decrease in the ability to perform activities of daily living (P <.05). There appears to be a risk for tear size progression over time.


Assuntos
Atividades Cotidianas , Lesões do Manguito Rotador , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Dor , Prognóstico , Fatores de Risco , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/patologia , Ultrassonografia
6.
Anesthesiology ; 94(4): 710-1, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11379695

RESUMO

Electric interference by cautery on demand pacemakers can cause inhibition and loss of pacing. We report a case in which electrocautery induced a pacemaker in ventricle-paced, ventricle-sensed, inhibited, rate-responsive (VVIR) mode to pace at a programmed maximum rate of 130 pulses/min.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Eletrocoagulação/efeitos adversos , Taquicardia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade
7.
Reg Anesth Pain Med ; 26(2): 100-4, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11251131

RESUMO

BACKGROUND AND OBJECTIVES: To quantify the motor threshold current of a needle following elicitation of paresthesia during axillary brachial plexus block (ABPB). METHODS: This is a prospective, observational study of ABPB in 72 patients. Having elicited paresthesia, the minimum current required to produce a motor response was noted. The development and success of the block were subsequently followed. RESULTS: Nineteen blocks were excluded (18 because of arterial puncture and 1 blocked needle). Of the remaining 53 blocks, 41 (77%) produced a motor response at 0.5 mA or less. The median current was 0.17 mA (range, 0.03 to 3.3 mA). The site of initial paresthesia and subsequent motor response were related in 43 (81%) of cases. CONCLUSIONS: A needle position causing paresthesia produced a motor response at 0.5 mA or less in 77% of cases studied. This current may, therefore, be a reasonable threshold to aim for when performing an ABPB.


Assuntos
Axila , Plexo Braquial , Bloqueio Nervoso , Parestesia , Anestésicos Locais , Braço , Estimulação Elétrica , Potencial Evocado Motor , Humanos , Lidocaína , Pessoa de Meia-Idade , Músculo Esquelético/inervação , Bloqueio Nervoso/métodos , Parestesia/etiologia , Estudos Prospectivos , Limiar Sensorial
8.
Radiology ; 218(2): 359-63, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11161147

RESUMO

PURPOSE: To determine in patients with testicular microlithiasis (TM) the short-term natural history of classic TM (CTM) and limited TM (LTM). MATERIALS AND METHODS: In 104 patients, testicular microliths were identified on ultrasonographic (US) images; 39 patients had five or more microliths on at least one US image (criterion for CTM), and 65 patients had fewer than five microliths (criterion for LTM). Attempts were made to have all patients return for follow-up US to assess for change in TM or development of tumor. RESULTS: Seven (18%) of the 39 patients with CTM and one (2%) of the 65 patients with LTM had tumor at presentation (P =.004). Among all 104 patients, follow-up US was performed in 72 patients (31 with CTM, 41 with LTM), with mean follow-up of 45 months (range, 12-90 months). None of these patients had interval development of testicular neoplasm. LTM did not progress to CTM in any patient. Progression in number of microliths was seen in two patients with CTM. CONCLUSION: Patients with LTM have a lower prevalence of associated malignancy than do patients with CTM. The risk of developing malignancy in patients with isolated TM (LTM or CTM) is low at short-term follow-up. These results raise the question of the need for routine US in this patient population.


Assuntos
Litíase/diagnóstico por imagem , Doenças Testiculares/diagnóstico por imagem , Adulto , Seguimentos , Germinoma/epidemiologia , Humanos , Litíase/epidemiologia , Masculino , Prevalência , Estudos Prospectivos , Fatores de Risco , Doenças Testiculares/epidemiologia , Neoplasias Testiculares/epidemiologia , Ultrassonografia
9.
Ultrasound Q ; 17(1): 21-36, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12973087

RESUMO

Although the anatomy of the hand and wrist is complex and the pathologic conditions encountered are diverse, many of the disease processes are localized, and in many situations, the clinical question is specific and limited. Because of this, ultrasound has always been an attractive imaging modality for evaluation of hand and wrist problems. Unfortunately, intrinsic difficulties in ultrasound image acquisition and interpretation have slowed the acceptance of hand and wrist sonography. Recently, however, new developments in high-resolution transducers and signal processing have dramatically improved image quality and scanning flexibility. For this reason, hand and wrist sonography is now more widely accepted and is taking its place along side other traditional modalities such as radiography, computed tomography, magnetic resonance imaging, and arthrography. Specific situations in which ultrasound offers definite benefits include evaluation of tendon inflammation and rupture, evaluation of palpable masses or suspected occult masses, and evaluation of suspected foreign bodies. Analysis of the median nerve is also possible and in the future, may have a role in patients with carpal tunnel syndrome.

10.
Semin Ultrasound CT MR ; 21(3): 192-204, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10994688

RESUMO

Not only is the anatomy of the hand and wrist complex, but also its pathologic conditions are quite diverse. Although plain radiographs, CT, arthrography, and MRI have traditionally been used to evaluate the hand and wrist, ultrasound is beginning to take its place alongside these more traditional imaging modalities and is being ordered with increasing frequency by orthopedic surgeons. This article reviews the pertinent gross anatomy and sonographic technique used to scan the hand and wrist and also describes the sonographic findings associated with the most common hand and wrist pathologic conditions. These include soft tissue tumors, tenosynovitis, tendinous and ligamentous injuries of the hand, Dupuytren's contracture, foreign bodies, and carpal tunnel syndrome (CTS).


Assuntos
Mãos/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Punho/diagnóstico por imagem , Síndrome do Túnel Carpal/diagnóstico por imagem , Contratura de Dupuytren/diagnóstico por imagem , Corpos Estranhos/diagnóstico por imagem , Traumatismos da Mão/diagnóstico por imagem , Hemangioma/diagnóstico por imagem , Humanos , Modelos Teóricos , Neoplasias de Tecidos Moles/diagnóstico por imagem , Tenossinovite/diagnóstico por imagem
11.
Eur J Gastroenterol Hepatol ; 12(9): 967-73, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11007131

RESUMO

OBJECTIVE: To determine the effect of a specialist nurse on the management outcome of patients with inflammatory bowel disease (IBD). DESIGN: Audit of the management of a cohort of patients in the year prior to the employment of the specialist nurse and the year immediately after. SUBJECTS: 339 patients, both male and female, with either Crohn's disease or ulcerative colitis, resident in the Cambridge health district. SETTING: Addenbrooke's Hospital NHS Trust Outpatient Centre. MAIN OUTCOME MEASURE: Health status was measured by blood tests (C-reactive protein, albumin and haemoglobin) throughout the year, symptom indices, number of clinic attendances, admissions to hospital and length of stay. Quality of life was measured via a postal questionnaire. RESULTS: Hospital visits were reduced from 1377 to 853 (38% reduction) and in-patient length of stay measured in bed-days from 516 to 417 (19% reduction). The number of patients in remission increased from 63 to 69%. Patient satisfaction improved in key areas, in particular, access to information on IBD and advice on avoidance of illness and maintaining health. Of a total of 251 calls to the telephone helpline, only 19 patients were referred for a medical opinion and five patients required hospital admission. CONCLUSION: The IBD nurse specialist is a valuable and cost-effective member of the gastroenterology team.


Assuntos
Doenças Inflamatórias Intestinais/enfermagem , Especialidades de Enfermagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Análise Custo-Benefício , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Doenças Inflamatórias Intestinais/psicologia , Doenças Inflamatórias Intestinais/terapia , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Auditoria de Enfermagem , Satisfação do Paciente , Qualidade de Vida , Especialidades de Enfermagem/economia , Inquéritos e Questionários , Resultado do Tratamento
12.
J Ultrasound Med ; 19(6): 377-8; quiz 383, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10841058

RESUMO

This study was undertaken to identify differences in the sonographic appearance of acute and chronic full-thickness rotator cuff tears. The ultrasonograms of 24 patients with an acute rotator cuff tear and 20 with a chronic tear were reviewed for tear size (width), location, and the presence and distribution of fluid. Among these 24 patients, 75% with a midsubstance tear location had an acute tear; 64% of patients with joint or bursal fluid had an acute tear; 80% of patients with a nonvisualized rotator cuff due to a massive tear had a chronic tear; and 73% of patients with no sonographic evidence of bursal or joint fluid had a chronic tear. In conclusion, a midsubstance location and the presence of joint or bursal fluid were more commonly associated with an acute tear. A nonvisualized cuff and the absence of joint and bursal fluid were more commonly observed with a chronic tear.


Assuntos
Manguito Rotador/diagnóstico por imagem , Lesões do Ombro , Doença Aguda , Adulto , Idoso , Artroscopia , Doença Crônica , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Manguito Rotador/cirurgia , Lesões do Manguito Rotador , Ruptura , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Dor de Ombro/diagnóstico por imagem , Dor de Ombro/etiologia , Dor de Ombro/cirurgia , Ultrassonografia
13.
J Bone Joint Surg Am ; 82(4): 498-504, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10761940

RESUMO

BACKGROUND: There has been limited acceptance of shoulder ultrasonography by orthopaedic surgeons in the United States. The purpose of this retrospective study was to determine the diagnostic performance of high-resolution ultrasonography compared with arthroscopic examination for the detection and characterization of rotator cuff tears. METHODS: One hundred consecutive shoulders in ninety-eight patients with shoulder pain who had undergone preoperative ultrasonography and subsequent arthroscopy were identified. The arthroscopic diagnosis was a full-thickness rotator cuff tear in sixty-five shoulders, a partial-thickness tear in fifteen, rotator cuff tendinitis in twelve, frozen shoulder in four, arthrosis of the acromioclavicular joint in two, and a superior labral tear and calcific bursitis in one shoulder each. All ultrasonographic reports were reviewed for the presence or absence of a rotator cuff tear and a biceps tendon rupture or dislocation. All arthroscopic examinations were performed according to a standardized operative procedure. The size and extent of the tear and the status of the biceps tendon were recorded for all shoulders. The findings on ultrasonography and arthroscopy then were compared for each parameter. RESULTS: Ultrasonography correctly identified all sixty-five full-thickness rotator cuff tears (a sensitivity of 100 percent). There were seventeen true-negative and three false-positive ultrasonograms (a specificity of 85 percent). The overall accuracy was 96 percent. The size of the tear on transverse measurement was correctly predicted in 86 percent of the shoulders with a full-thickness tear. Ultrasonography detected a tear in ten of fifteen shoulders with a partial-thickness tear that was diagnosed on arthroscopy. Five of six dislocations and seven of eleven ruptures of the biceps tendon were identified correctly. CONCLUSIONS: Ultrasonography was highly accurate for detecting full-thickness rotator cuff tears, characterizing their extent, and visualizing dislocations of the biceps tendon. It was less sensitive for detecting partial-thickness rotator cuff tears and ruptures of the biceps tendon.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador/diagnóstico por imagem , Dor de Ombro/etiologia , Artroscopia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ruptura , Sensibilidade e Especificidade , Traumatismos dos Tendões/diagnóstico , Traumatismos dos Tendões/diagnóstico por imagem , Traumatismos dos Tendões/cirurgia , Ultrassonografia
14.
Radiology ; 214(1): 167-72, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10644118

RESUMO

PURPOSE: To determine the need for follow-up imaging in patients with a low risk of malignancy and with ultrasonographic (US) findings typical of hepatic hemangioma. MATERIALS AND METHODS: A computer search of US reports completed between 1991 and 1994 helped identify 383 patients whose reports contained the word "hemangioma." One hundred eleven patients were excluded because the lesion's appearance was atypical (n = 16) or because the patients had a high risk of malignancy (prior history or current evidence of extrahepatic malignancy or chronic hepatic disease [n = 95]). Fifty-nine patients were excluded because they were lost to follow-up (n = 41) or had clinical follow-up of less than 2 years (n = 18). The conditions of the remaining 213 patients with typical-appearing hemangiomas and a low risk of malignancy were analyzed. One hundred twenty-one patients underwent imaging follow-up or histopathologic confirmation. Ninety-two had clinical follow-up of more than 2 years (mean, 46 months). RESULTS: Of the 213 patients, four had benign lesions other than hemangiomas. One patient who subsequently developed a malignancy (neuroendocrine metastases from primary colonic carcinoma diagnosed 22 months after initial US) potentially had an early metastasis that was misdiagnosed as a hemangioma. CONCLUSION: On the basis of these results, the authors no longer recommend follow-up studies in their patients with a low risk of malignancy and a typical-appearing hemangioma at US.


Assuntos
Hemangioma/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Sensibilidade e Especificidade , Ultrassonografia
15.
Surgery ; 126(4): 736-41; discussion 741-3, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10520923

RESUMO

INTRODUCTION: Pancreatic lesions may be difficult to diagnose because of small size or inaccessibility. Such lesions are being seen with increasing frequency because of advances in pancreatic imaging techniques. In the past 18 months we have evaluated 14 patients whose pancreatic lesions could not be diagnosed by traditional means, including percutaneous biopsy. METHODS: With the patient under general anesthesia, the anterior surface of the pancreas was exposed by a three-trocar laparoscopic technique. The lesion was located by laparoscopic ultrasonography. A core biopsy needle was inserted into the lesion under simultaneous visual and ultrasonographic guidance using picture-in-picture techniques. RESULTS: The main diagnostic dilemma encountered was the differentiation of pancreatic cancer from pancreatitis. Other conditions were lymphoma and renal cell carcinoma. Excellent tissue samples were obtained, allowing diagnosis and planning of treatment in all cases. Operative time ranged from 1 to 4 hours, and length of stay ranged from 1 to 3 days. Blood transfusions were not required, and there were no complications. Alcohol nerve block was performed laparoscopically in one patient in this group after the diagnosis was made by frozen section. CONCLUSIONS: Direct ultrasonographically guided laparoscopic biopsy provides rapid, safe diagnosis of pancreatic lesions.


Assuntos
Laparoscopia , Neoplasias Pancreáticas/patologia , Pancreatite/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia/métodos , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ductos Pancreáticos/diagnóstico por imagem , Ductos Pancreáticos/patologia , Neoplasias Pancreáticas/diagnóstico por imagem , Pancreatite/diagnóstico por imagem , Tomografia Computadorizada de Emissão , Tomografia Computadorizada por Raios X , Ultrassonografia
16.
Radiol Clin North Am ; 37(4): 767-85, ix, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10442080

RESUMO

Since the mid 1980s, sonography has been used to evaluate the rotator cuff. It is inexpensive, well tolerated, rapidly performed, and accurate. With the recent improvements in imaging equipment and refinements in scanning technique, an increasing number of radiologists are performing shoulder sonography. This article emphasizes the pertinent musculoskeletal anatomy, sonographic technique, normal sonographic anatomy, pathophysiology of rotator cuff and biceps tendon disease, sonographic findings of rotator cuff tears, and biceps tendon pathology. The accuracy of ultrasound in diagnosing rotator cuff tears and miscellaneous abnormalities that can be detected with ultrasound also are discussed.


Assuntos
Ombro/anatomia & histologia , Ombro/diagnóstico por imagem , Humanos , Músculo Esquelético/diagnóstico por imagem , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/patologia , Lesões do Manguito Rotador , Ombro/patologia , Tendões/diagnóstico por imagem , Ultrassonografia
17.
AJR Am J Roentgenol ; 172(5): 1245-8, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10227497

RESUMO

OBJECTIVE: The purpose of this study was to determine whether differences exist in baseline flow velocities in the main portal vein and the stent after the creation of transjugular intrahepatic portosystemic shunts with 10- and 12-mm Wallstents. SUBJECTS AND METHODS: We used Doppler sonography to determine baseline flow velocities in the stent and the main portal vein in 80 patients (38 patients with 10-mm Wallstents dilated to 10 mm and 42 patients with 12-mm Wallstents dilated to 12 mm) who had undergone creation of trans jugular intrahepatic portosystemic shunts without complications. RESULTS: We found no significant difference in the maximum flow velocity in the stent between the patients with 10-mm stents (160.3+/-34.3 cm/sec) and those with 12-mm stents (164.4+/-33.8 cm/sec). We also found no significant difference in the minimum flow velocity in the stent between the 10-mm group (132.4+/-28.9 cm/sec) and the 12-mm group (126.7+/-28.3 cm/sec). However, flow velocity through the main portal vein was significantly higher in the patients with 12-mm stents (53.6+/-18.4 cm/sec) than in those with 10-mm stents (45.1+/-13.8 cm/sec) (p < .03). CONCLUSION: After creation of transjugular intrahepatic portosystemic shunts, baseline flow velocities in the main portal vein in patients with 12-mm stents exceeded those in patients with 10-mm stents, although neither maximum nor minimum flow velocities in the stent differed between these two groups of patients. These findings suggest that criteria for shunt malfunction that use flow velocity in the main portal vein may need modification when 12-mm stents are being evaluated.


Assuntos
Derivação Portossistêmica Transjugular Intra-Hepática , Stents , Ultrassonografia Doppler , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veia Porta/diagnóstico por imagem
18.
J Ultrasound Med ; 18(2): 147-52, 1999 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10206808

RESUMO

The usage patterns and benefits of extended field of view sonography were analyzed prospectively in 100 consecutive musculoskeletal ultrasonographic examinations. Extended field of view sonography was used in 23 of 58 abnormal cases (10 of 41 shoulders, five of eight other joints, seven of seven extra-articular extremities, one of two interventional procedures) and two of 42 normal cases. Of 23 abnormal cases using extended field of view sonography (12 of 46 tendon tears and 11 of 12 fluid collections or masses), this modality helped in measuring abnormalities in 13, displaying abnormalities in 19, showing spatial relationships in 17, communicating findings in 13, and making diagnoses in 0. Extended field of view is a useful technique for musculoskeletal ultrasonography. The primary benefits are measuring and displaying abnormalities (most often fluid collections or masses and extra-articular extremity abnormalities).


Assuntos
Anormalidades Musculoesqueléticas/diagnóstico por imagem , Sistema Musculoesquelético/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Articulações/anormalidades , Articulações/diagnóstico por imagem , Deformidades Congênitas dos Membros/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tendões/anormalidades , Tendões/diagnóstico por imagem , Ultrassonografia
19.
Am J Surg ; 178(6): 490-5, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10670859

RESUMO

BACKGROUND: The purpose of this study was to determine the usefulness of laparoscopic ultrasound (LUS) during laparoscopic adrenalectomy (LA) and to define the ultrasound imaging characteristics of various adrenal tumors. METHODS: LUS was utilized in 27 patients who underwent LA (including one bilateral adrenalectomy) from May 1994 to October 1998. Tumor size ranged from 1.0 to 5.5 cm (mean 3.3 cm), and a transabdominal lateral approach to LA was used. RESULTS: LUS localized the adrenal gland and tumor in all 28 adrenalectomies and demonstrated the relationship of the tumor to the kidney and adjacent vascular structures (renal artery/vein and inferior vena cava). The adrenal vein was visualized sonographically in only six cases (21 %). Pheochromocytomas were mild to markedly heterogenous, whereas most aldosteronomas and cortical adenomas were homogenous. LUS provided useful information to the surgeon in 11 of 28 cases (39%) by: 1) localizing the adrenal gland and tumor and/or guiding the dissection; 2) demonstrating that tumors > or =4 cm were confined to the adrenal gland; and 3) investigating suspected pathology in other organs. Mean operating time for LUS was 10.9 min (range 5 to 24 min) and calculated hospital charges were $602. CONCLUSIONS: LUS accurately localizes adrenal tumors, helps define their relationship to adjacent structures, and provides confirmation that larger tumors are amenable to laparoscopic resection. LUS is a useful adjunct to laparoscopic adrenalectomy in selected patients.


Assuntos
Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/cirurgia , Adrenalectomia/métodos , Endossonografia , Laparoscopia , Neoplasias do Córtex Suprarrenal/diagnóstico por imagem , Neoplasias do Córtex Suprarrenal/cirurgia , Glândulas Suprarrenais/diagnóstico por imagem , Adenoma Adrenocortical/diagnóstico por imagem , Adenoma Adrenocortical/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Feocromocitoma/diagnóstico por imagem , Feocromocitoma/cirurgia
20.
Aust N Z J Psychiatry ; 32(2): 235-41, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9588303

RESUMO

OBJECTIVE: The study investigated previous research findings and clinical impressions which indicated that the intensity of grief for parents who had lost a child was likely to be higher than that for widows/widowers, who in turn were likely to have more intense reactions than adult children losing a parent. METHOD: In order to compare the intensities of the bereavement reactions among representative community samples of bereaved spouses (n = 44), adult children (n = 40) and parents (n = 36), and to follow the course of such phenomena, a detailed Bereavement Questionnaire was administered at four time points over a 13-month period following the loss. RESULTS: Measures based on items central to the construct of bereavement showed significant time and group differences in accordance with the proposed hypothesis. More global items associated with the construct of resolution showed a significant time effect, but without significant group differences. CONCLUSIONS: Evidence from this study supports the hypothesis that in non-clinical, community-based populations the frequency with which core bereavement phenomena are experienced is in the order: bereaved parents > bereaved spouses > bereaved adult children.


Assuntos
Luto , Cuidadores/psicologia , Pais/psicologia , Viuvez/psicologia , Adaptação Psicológica , Adulto , Idoso , Criança , Morte Súbita , Feminino , Seguimentos , Pesar , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Relações Pais-Filho , Inventário de Personalidade , Assistência Terminal/psicologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA