Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Br Dent J ; 236(8): 603-610, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38671111

RESUMO

Understanding that dental carious lesions occur as a result of the action of micro-organisms in the dental plaque biofilm, where demineralisation on the tooth surface is the first sign of the disease, such incipient lesions can be treated using preventive, non-operative and minimally invasive operative dentistry. If the caries process is left unmanaged, the lesions progress towards cavitation, leading to more invasive treatments. This article discusses the principles of preventive, non-invasive and micro-invasive treatments of early carious lesions, outlining the clinical situations where these therapies can be applied.


Assuntos
Cárie Dentária , Humanos , Cárie Dentária/prevenção & controle , Cárie Dentária/terapia , Biofilmes , Cariostáticos/uso terapêutico , Placa Dentária/prevenção & controle , Restauração Dentária Permanente/métodos
2.
Polymers (Basel) ; 16(5)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38475291

RESUMO

The aim of this study was to compare the mechanical properties and ion release from a commercially available resin-modified glass ionomer cement to a formulation reinforced by the addition of short glass fibres at various percentages. Methods: Three experimental groups were prepared by adding a mass ratio of 10%, 15% and 20% of short glass fibres to the powder portion of the cement from a capsule (GC Fuji II LC), while the control group contained no fibres. Microhardness (n = 12), fracture toughness, and flexural, compressive and diametral tensile strength (n = 8) were evaluated. To study ion release, readings were obtained utilising fluoro-selective and calcium-selective electrodes after 24 h, 7 days and 30 days (n = 12). The spatial distribution of fibres within the material was evaluated through scanning electron microscopy. The data were analysed using one-way ANOVA with a Bonferroni adjustment. Results: The findings suggest that elevating fibre weight ratios to 20 wt% results in improved mechanical properties (p < 0.05) in microhardness, flexural strength, diametral tensile strength and fracture toughness. In terms of ion release, a statistically significant difference (p < 0.001) was observed between the groups at the conclusion of 24 h and 7 days, when the fluoride release was much higher in the control group. However, after 30 days, no significant distinction among the groups was identified (p > 0.05). Regarding calcium release, no statistically significant differences were observed among the groups at any of the evaluated time points (p > 0.05). SEM showed the fibres were homogeneously incorporated into the cement in all experimental groups. Conclusions: Resin-modified glass ionomer enhanced with short glass fibres at a weight loading of 20% showcased the most favourable mechanical properties while concurrently maintaining the ability to release fluoride and calcium after a 30-day period.

3.
Clin Oral Investig ; 28(1): 104, 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38243032

RESUMO

OBJECTIVE: To evaluate the 5-year clinical performance of a glass hybrid restorative system and a nano-hybrid resin composite in moderate to large two-surface class II cavities. MATERIALS AND METHODS: This study was carried out by dental schools in Zagreb, Croatia; Izmir, Turkey; Belgrade, Serbia; and Milan, Italy. A total of 180 patients requiring two class-II two-surface restorations in the molars of the same jaw were recruited. The teeth were randomly restored with either a nano-hybrid resin composite (Tetric EvoCeram, Ivoclar Vivadent) or a glass-hybrid material (EQUIA Forte, GC). During the 5-year follow-up, two calibrated evaluators at each centre scored the restorations annually using the FDI-2 scoring system. The survival rates were calculated using the Kaplan-Meier method and compared using non-parametric matched pair tests (p < 0.05). RESULTS: There were no statistically significant differences between the overall survival and success rates of the two types of restorations (p>0.05). The success rates (FDI-2 scores 1-3) for EQUIA Forte were 81.9% (average annual failure rate: 3.9%) and 90.7% for Tetric EvoCeram (average annual failure rate: 1.9%). The survival rates (FDI-2 scores 1-4) for EQUIA Forte and Tetric EvoCeram were 94.5% and 94.4%, respectively, with an average annual failure rate of 1.1%. CONCLUSIONS: In terms of success and survival rates, both the glass-hybrid restorative system and the nano-hybrid resin composite have been shown to perform satisfactorily. CLINICAL RELEVANCE: The results of this study indicate that EQUIA Forte can be one of the therapeutic options for moderate to large two-surface class II restorations of posterior teeth.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Humanos , Restauração Dentária Permanente/métodos , Resinas Compostas/uso terapêutico , Materiais Dentários , Dente Molar , Cárie Dentária/terapia , Vidro , Cimentos de Ionômeros de Vidro/uso terapêutico
4.
Materials (Basel) ; 16(23)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38068054

RESUMO

The aim of this study was to compare the potential of standard ion-releasing materials to repair demineralized lesions with recently introduced alkasite and glass hybrid materials. Glass ionomer (GC Fuji TRIAGE), two glass hybrids (EQUIA Forte HT, Riva SC), calcium silicate cement (Biodentine) and an alkasite (Cention Forte) were tested. A total of 72 human third molars were used for sample preparation; on the dentine surface, a class-I cavity was prepared, and one half was covered with nail varnish. The teeth were subjected to a demineralization protocol, filled with the examined materials, and cut in half. The evaluation included a dentine microhardness assessment (n = 10) and SEM/EDS analysis (n = 2). The results were analyzed using SPSS 22.0 statistical software and compared using an analysis of variance and Scheffe post-hoc test. The statistical significance level was set to 0.05. Mean microhardness values (HV0.1) after 14 and 28 days were, respectively: EQUIA Forte HT (26.7 ± 1.45 and 37.74 ± 1.56), Riva Self Cure (19.66 ± 1.02 and 29.58 ± 1.18), Cention Forte (19.01 ± 1.24 and 27.93 ± 1.33), Biodentine (23.35 ± 1.23 and 29.92 ± 1.02), GC Fuji TRIAGE (25.94 ± 1.35 and 33.87 ± 5.57) and control group (15.57 ± 0.68 and 15.64 ± 0.82). The results were significantly different between most groups (p < 0.001). SEM/EDS revealed varying patterns, material deposits and distinct elemental variations. To conclude, all materials increased microhardness and affected the dentine surface appearance and chemical composition; EQUIA Forte HT demonstrated the most pronounced effects.

5.
Acta Stomatol Croat ; 57(3): 229-237, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37808411

RESUMO

Objective: To compare short-term release of fluoride ions from ion-releasing dental restorative materials. Material and methods: Seven experimental groups were prepared using the following six different materials: alkasite (Cention Forte), resin-modified glass ionomer cement (Fuji II LC), bioactive composite (ACTIVA BioACTIVE-RESTORATIVE), fluoride-containing nano-hybrid composite (Luminos UN), coat-free glass hybrid (EQUIA Forte HT), coat-applied glass hybrid (EQUIA Forte HT), and glass ionomer cement (Fuji IX). A total of 40 samples for each group (n=40) were prepared in Teflon molds (8 mm x 2 mm) and placed in polyethylene vials with 5 ml of deionized water. Fluoride release was measured after 6, 24, 48 hours, and for 5 weeks using an ion-selective electrode. The results were expressed in mg/l and the data were statistically analyzed using ANOVA. Results: Significant differences in fluoride release were observed within the first 6 hours (ANOVA p<0.001). EQUIA Forte HT had the highest release, while the other materials showed no significant differences. After 24 hours, EQUIA Forte HT (p<0.001) and Luminos UN (p<0.05) exhibited significantly higher releases, compared to other tested materials. EQUIA Forte HT maintained the highest release at 48 hours (p<0.001), followed by Cention Forte (p<0.05) and Luminos UN (p<0.05). All material pairs showed significant differences in fluoride release at 5 weeks (p<0.001). Conclusion: Coat-free EQUIA Forte HT had the overall highest fluoride release, while Cention Forte demonstrated the greatest increase over time. ACTIVA BioACTIVE-RESTORATIVE exhibited the lowest fluoride release in this study.

6.
Front Med (Lausanne) ; 10: 1201517, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37663665

RESUMO

Aim: To establish the inter-rater reliability of the Composite Quality Score (CQS-2) and to test the null hypothesis that it did not differ significantly from that of the first CQS version (CQS-1). Materials and methods: Four independent raters were selected to rate 45 clinical trial reports using CQS-1 and CQS-2. The raters remained unaware of each other's participation in this study until all rating had been completed. Each rater received only one rating template at a time in a random sequence for CQS-1 and CQS-2 rating. Raters completed each template and sent these back to the principal investigator. Each rater received their next template 2 weeks after submission of the completed previous template. The inter-rater reliabilities for the overall appraisal score of the CQS-1 and the CQS-2 were established by using the Brennan-Prediger coefficient (BPC). The coefficients of both CQS versions were compared by using the two-sample z-test. During secondary analysis, the BPCs for every criterion and each corroboration level for both CQS versions were established. Results: The BPC for the CQS-1 was 0.85 (95% CI: 0.64-1.00) and for the CQS-2 it was 1.00 (95% CI: 0.94-1.00), suggesting a very high inter-rater reliability for both. The difference between the two CQS versions was statistically not significant (p = 0.17). The null hypothesis was accepted. Conclusion: The CQS-2 is still under development, This study shows that it is associated with a very high inter-rater reliability, which did not statistically significantly differ from that of the CQS-1. The promising results of this study warrant further investigation in the applicability of the CQS-2 as an appraisal tool for prospective controlled clinical therapy trials.

7.
Materials (Basel) ; 16(8)2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37110109

RESUMO

This study sought to evaluate the efficacy of SWEEPS in the removal of epoxy-resin-based and calcium-silicate-containing endodontic sealer combined with single-cone and carrier-based obturation techniques through a micro-CT analysis. Seventy-six single-rooted extracted human teeth with single root canal were instrumented with Reciproc instruments. Specimens were randomly divided into four groups (n = 19) according to the root canal filling material and obturation technique: (1) AH Plus sealer + Reciproc gutta-percha, (2) TotalFill BC sealer + TotalFill BC Points, (3) AH Plus sealer + Guttafusion obturator, and (4) MTA Fillapex + Guttafusion obturator. All specimens were re-treated one week later using Reciproc instruments. Following re-treatment, root canals were additionally irrigated using the Auto SWEEPS modality. The differences in the root canal filling remnants were analyzed by micro-CT scanning of each tooth after root canal obturation, after re-treatment, and after additional SWEEPS treatment. Statistical analysis was performed using an analysis of variance (p < 0.05). The additional treatment with SWEEPS significantly reduced the volume of the root canal filling materials in all experimental groups compared to the removal of root canal filling using only reciprocating instruments (p < 0.05). However, the root canal filling was not removed completely from any of the samples. SWEEPS can be used to enhance the removal of both epoxy-resin-based and calcium-silicate-containing sealers, in combination with single-cone and carrier-based obturation techniques.

8.
Materials (Basel) ; 16(4)2023 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-36837160

RESUMO

Over the past few decades, adhesive dentistry has advanced significantly. In light of minimal-invasive dentistry, this novel technique advocates a more conservative cavity design that relies on the efficiency of present enamel-dentine adhesives. The study aimed to address the scientific deficit in understanding the long-term bonding performance of universal adhesives and to provide a new clinical solution with desirable bond strength to dentin. The dentin bond strength of three bonding agents, G2-Bond Universal (GC), Clearfil SE Bond (Kuraray), and Scotchbond Universal Plus (3M ESPE), was evaluated following various storage and etching modes. The UltraTester (Ultradent) bond strength testing machine was used to assess shear bond strength. The results showed that thermal cycling and the choice of adhesive system significantly affected the shear bond strength (p = 0.018 and p = 0.001, respectively). Among the three adhesives, Scotchbond Universal Plus had the lowest bond strength value (mean value = 24.78 MPa), while G2-Bond Universal was found to have desirable shear bond strength to dentin compared to the other adhesives, even after one year in the oral environment (mean value = 35.15 MPa). These findings imply that the HEMA-free universal adhesive G2-Bond Universal is the most effective universal adhesive for clinical practices, particularly when applied in the self-etch mode.

9.
Rev Recent Clin Trials ; 18(1): 28-33, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36600618

RESUMO

BACKGROUND: Current evidence appraisal concepts, such as the Assessment, Development and Evaluation (GRADE) approach and Cochrane's Risk of Bias (RoB) tool, rely on assumptions related to the classic problem of inductive reasoning and may suffer from insufficient inter-rater reliability. DISCUSSION: The Composite Quality Score (CQS) has emerged as a possible trial appraisal tool that does not rely on inductive assumptions and has been shown to be of potentially very high inter-rater reliability. CONCLUSION: Although the current CQS concept is still under development, its current evidence is encouraging and justifies further study. This article presents the rationale and currently available research concerning the CQS and shows where further research is required.


Assuntos
Resolução de Problemas , Humanos , Viés , Estudos Prospectivos , Reprodutibilidade dos Testes , Ensaios Clínicos Controlados como Assunto
10.
Acta Stomatol Croat ; 57(4): 316-328, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38283313

RESUMO

Objectives: To examine the effects of different whitening agents on the color and translucency of different resin composites, in vitro. Material and methods: A total of 315 specimens (10.0 ×2.0 mm) were fabricated from two microhybrid (G-aenial anterior [G-Ant]) and (G-aenial posterior [G-Post]) and a nano hybrid (G-aenial A'CHORD [ G-ACH]) resin composites and each group was randomly distributed into seven experimental groups (n=15) as follows; 1- control (C); 2- in-office whitening agent (IOW); 3- at-home whitening agent (AHW); 4- prefilled tray (PT); 5- whitening pen (WP); 6- whitening toothpaste (WT) and 7- whitening mouthwash (WMW). The specimens were subjected to staining except control group before application of the different whitening procedures. The color of specimens was measured after 24 h (T0), after staining (T1) and after whitening (T2). Color change [CIEDE2000 (ΔE00)], translucency parameter (TP) values and changes in whiteness index (WID) were calculated. Data were analyzed statistically (p<0.05). Results: No significant 𝑊ID differences were detected among the tested resin composites at T0 and T1 (p>0.05), whereas a significant difference was observed at T2 (p<0.005). AHW and IOW produced higher color change than PT, WP, WT and WMR. Significant TP changes were found after the application of IOW and AHW in G-Ant. Conclusion: The effect of whitening products on the whitening index, color and translucency of resin composites are material and substrate dependent.

11.
PLoS One ; 17(12): e0279645, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36584067

RESUMO

AIM: To conduct a survey of current meta-epidemiological studies to identify additional trial design characteristics that may be associated with significant over- or underestimation of the treatment effect and to use such identified characteristics as a basis for the formulation of new CQS appraisal criteria. MATERIALS AND METHODS: We retrieved eligible studies from two systematic reviews on this topic (latest search May 2015) and searched the databases PubMed and Embase for further studies from June 2015 -March 2022. All data were extracted by one author and verified by another. Sufficiently homogeneous estimates from single studies were pooled using random-effects meta-analysis. Trial design characteristics associated with statistically significant estimates from single datasets (which could not be pooled) and meta-analyses were used as a basis to formulate new or amend existing CQS criteria. RESULTS: A total of 38 meta-epidemiological studies were identified. From these, seven trial design characteristics associated with statistically significant over- or underestimation of the true therapeutic effect were found. CONCLUSION: One new criterion concerning double-blinding was added to the CQS, and the original criteria for concealing the random allocation sequence and for minimum sample size were amended.


Assuntos
Estudos Prospectivos , Estudos Epidemiológicos , PubMed
12.
Polymers (Basel) ; 14(10)2022 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-35631949

RESUMO

Acidic drinks are known to exert negative effects on the surface properties of dental restorative materials. However, the effect of increasingly popular green smoothie drinks has not been addressed so far. The present study investigated the effect of cyclic immersions (5 min daily over 30 days) in a green smoothie drink on the surface properties of contemporary dental restorative materials, including resin composites, an alkasite, and a glass hybrid. Vickers microhardness, profile roughness, and perceptible color change in the CIE L* a* b* color space were evaluated as clinically relevant properties of the material surface. After 30-day green smoothie immersion, microhardness values either decreased by 8-28% (for resin composites) or increased by up to 91% (for glass hybrid). The increase in profile roughness (Ra parameter) of smoothie-immersed specimens was 7-26 times higher compared to the control group. The perceptible color change (ΔE*) in the smoothie group was 3-8 times higher compared to the control group. Overall, this study demonstrated that daily exposure of dental restorations made from resin composites, alkasites, and glass hybrid materials to a green smoothie drink can significantly accelerate material degradation, which is reflected as surface softening, as well as higher roughness and higher perceptible color change.

13.
Microsc Res Tech ; 85(3): 1171-1179, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34766666

RESUMO

The purpose of this study was to evaluate the surface roughness, microhardness, color change, and translucency of a newly marketed universal nanohybrid composite resin (CR) (G-aenial A'CHORD) comparing with four contemporary universal CRs including two nanofilled (Filtek and Estelite Asteria) and two nanohybrid CRs (Charisma Dimond and Neo Spectra ST HV in vitro). Sixty-five specimens (8.0 mm × 2.0 mm) were fabricated (n = 13, per group). After finishing and polishing, specimens were subjected to surface roughness and microhardness tests. Color and translucency of the specimens were evaluated at baseline and after darkening with coffee solution at day 1 and day 7. A representative specimen from each group was investigated under scanning electron microscopy (SEM). Data was analyzed statistically (p < .05). There were significant differences among the groups in terms of surface roughness, microhardness, color, and translucency. The surface roughness was recorded as: Charisma Diamond > Neo Spectra ST HV, Filtek > Estelite Asteria, G-aenial A'CHORD, whereas Vickers Hardness number was as: Filtek, Charisma Diamond > Neo Spectra ST HV > G-aenial A'CHORD, Estelite Asteria. Color change was as: Charisma Diamond > Neo Spectra ST HV, Filtek, G-aenial A'CHORD > Estelite Asteria and the translucency was as: Neo Spectra ST HV > G-aenial A'CHORD, Filtek > Estelite Asteria, Charisma Diamond. SEM examinations revealed smooth surfaces for G-aenial A'CHORD, Neo Spectra ST HV and Estelite Asteria. Mechanical and optical properties of universal composite resins with different compositions show variations.


Assuntos
Resinas Compostas , Diamante , Dureza , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície
14.
Microsc Res Tech ; 85(5): 1694-1702, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34921572

RESUMO

The purpose of this in vitro study was to compare the shear bond strengths (SBSs) of two newly marketed self-adhesive resin cements (RCs) to enamel, dentin, and lithium disilicate (LiSi) glass ceramic block. Forty-eight enamel and 48 dentin substrates were obtained from sound human molars. Additionally, 6 × 7 × 5 -mm- sized 24 specimens were produced from LiSi glass ceramic blocks. The tooth specimens were randomly assigned into four groups (n = 12) according to the surface treatments: (1) G-CEM ONE (GCO), (2) G-CEM ONE Adhesive Enhancing Primer (GCO-AEP) + GCO, (3) RelyX Universal (RXU), and (4) Scotchbond Universal Plus (SUP) + RXU. LiSi specimens were randomly divided into two groups (n = 12): (1) G-MultiPrimer (GMP) + GCO and (2) SUP + RXU. Following the RC applications, all specimens were kept in 100% humidity at 37°C for 24 hr and then submitted for SBS testing in a universal testing machine (1 mm/min). Data were analyzed by Welch's, one-way analysis of variance and two independent samples t tests. The nature of failures was examined under a light microscope, and scanning electron microscopy analyses were also performed for interfaces. GCO and RXU showed similar SBS to enamel (p > .05), and the use of adhesives resulted in improved SBS (p < .05). No difference was detected between GCO-AEP + GCO and SUP + RXU. The GCO-AEP + GCO exhibited the highest SBS to dentin (p < .05), followed by GCO ≥ SUP + RXU > RXU (p < .05). There was no significant difference between SBSs of two RCs to LiSi blocks (p > .05). No cohesive failure was determined for the tested groups by light microscope. The use of adhesives prior to the application of self-adhesive RCs improved their bonding to tooth tissues. GCO demonstrated superior SBS to dentin, whereas both self-adhesive RCs generated similar SBS to enamel and LiSi glass ceramic surfaces.


Assuntos
Colagem Dentária , Cimentos de Resina , Adesivos , Análise do Estresse Dentário , Dentina , Adesivos Dentinários/química , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina/química , Propriedades de Superfície
15.
Materials (Basel) ; 14(21)2021 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-34772195

RESUMO

The objective of this study was to evaluate the efficacy of reciprocating instruments in the removal of bioceramic and epoxy resin-based sealers using micro-CT analysis. Root canals of 40 extracted human teeth were instrumented with a size R25 Reciproc instrument. Specimens were randomly divided into two groups (n = 20) according to the root canal filling material. In the first group, root canals were obturated with AH Plus sealer and Reciproc R25 gutta-percha. In the second group, a combination of bioceramic gutta-percha (TotalFill BC) and bioceramic sealer (TotalFill BC) was used. After one week, the retreatment of all specimens was performed using Reciproc instruments. To analyze the differences in the filling remnants, specimens were scanned in a micro-CT device after obturation and after the retreatment procedure. Statistical analysis was performed using the Mann-Whitney U test (p < 0.05). A combination of bioceramic sealer and bioceramic gutta-percha was more effectively removed from canals using a reciprocating instrument, with a filling remnants volume of 4.01 ± 3.13 mm3, in comparison to the combination of epoxy resin-based sealer and gutta-percha (6.96 ± 2.70 mm3) (p < 0.05). A reciprocating instrument was more effective in removing bioceramic sealers than epoxy resin-based sealers, although none of the root canal filling materials were completely removed from the root canals.

16.
Materials (Basel) ; 14(21)2021 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-34771800

RESUMO

The contemporary approach for operative caries management emphasizes personalized interventions for each patient, dependent upon the individual's caries susceptibility/risk, the stage of the carious lesion and its activity. The clinician's challenge is to optimize the extent of cavity preparation and the choice of dental restorative biomaterials, appreciating the benefits offered by ion-releasing restorative materials. There is a growing application of bioactive/bio-interactive materials in minimally invasive operative dentistry, as they may help with tissue recovery by ion release. In case of moderate or extensive occlusal cavitation, the clinical criteria include the individual caries susceptibility and carious lesion activity. In high caries risk cases, ion-releasing biomaterials (IRB) can be used, as well as for active carious lesions. In proximal lesions, the clinical criteria include the individual caries susceptibility, the lesion activity and presence of cavities with little or no enamel at the gingival margin. This article aims to discuss the restorative ion-releasing options, according to different clinical situations, and the caries susceptibility to manage cavitated carious lesions in permanent adult teeth.

17.
Materials (Basel) ; 14(20)2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34683643

RESUMO

This study aimed to determine the effects of three different varnish materials (containing casein phosphopeptide-amorphous calcium phosphate, nano-hydroxyapatite, and fluoride) on enamel. Thirty-three extracted human third molars were used for specimen preparation. These were demineralized using phosphoric acid. Three experimental groups (n = 11) were treated with 3M™ Clinpro™ White Varnish, MI Varnish®, and Megasonex® toothpaste, respectively, every twenty-four hours for fourteen days. Analysis of the microhardness of the specimens' enamel surfaces was carried out via the Vickers method, and by scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDS). Analysis was performed at three stages: at baseline value, after demineralization, and after the period of remineralization. Data were subjected to Scheffe's post hoc test. The mean microhardness values (HV0.1) obtained for the group of samples treated with MI Varnish® were higher compared with the other two groups (p = 0.001 for both comparisons), while the first and third groups did not differ significantly from each other (p = 0.97). SEM analysis showed uneven patterns and porosities on all samples tested. EDS results showed an increase in the mineral content of the examined samples, with the highest mineral content observed in the MI Varnish® group. It can be concluded that MI Varnish® use has a better remineralization effect on enamel than the other two materials.

18.
Clin Oral Investig ; 25(10): 6015-6023, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34379191

RESUMO

OBJECTIVE: To establish the CQS inter-rater reliability and rating time and to compare both against that of the Jadad scale and Cochrane's Risk of Bias Tool (ROBT). MATERIAL AND METHODS: Four independent raters rated 45 trial reports. The inter-rater reliability was established by use of the Brennan-Prediger coefficient (BPC). The coefficients were compared using the two-sample z-test. Secondary analysis included comparison of the inter-rater reliability of the randomization component of all tools, as well as of the allocation concealment component of the CQS to that of the ROBT. The mean rating time with standard deviation (SD) for each tool was determined using one-way repeated measures analysis of variance. Post hoc comparisons were made using the Tukey-Kramer adjustment for three pair-wise multiple comparisons. RESULTS: The inter-rater reliability was significantly higher for the CQS (BPC, 95% CI: 0.95, 0.87-1.00) compared to Jadad (0.70, 0.58-0.82) (adjusted p = 0.0005) and most components of ROBT. The mean (SD) time to complete the CQS (4.0 (1.0) min) did not differ significantly from that of the Jadad scale 4.8 (1.1) min (adjusted p = 0.11), but was significantly shorter compared to that of the ROBT 15.3 (5.9) min (adjusted p < 0.0001). CONCLUSIONS: The results suggest the CQS to be a very reliable and fast trial appraisal tool. Clinical relevance The higher the inter-rater reliability, the higher the probability that trial results reflect therapeutic truth. The CQS will need to take further bias sources into consideration, in order to increase its utility.


Assuntos
Reprodutibilidade dos Testes , Humanos , Variações Dependentes do Observador
19.
Acta Stomatol Croat ; 55(2): 129-136, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34248146

RESUMO

OBJECTIVES: To determine the accuracy of visual damage evaluation of rotating and reciprocal endodontic instruments with the naked eye and optical devices. MATERIAL AND METHODS: Four examiners were involved, divided into two age groups: I. 20-30 years, n = 2, II. 40-50 years, n = 2. They visually assessed the existence of damage to rotating or reciprocal endodontic instruments by their naked eye and with two types of optical aids. A total of 239 instruments from different manufacturers were evaluated by each examiner. Before damage estimation, each examiner calibrated the eye on a new instrument. Sensitivity of the detection method was calculated as by the naked eye. When an instrument was detected as damaged by the naked eye, the damage assessment was stopped and the instrument was considered to be damaged by the other two methods, as well. RESULTS: Damage was found in 178 instruments. Sensitivity of the naked eye was calculated to be 49.7%, for the loupe 66.2% and for the operating microscope 76.5%. The three methods of damage assessment had significant differences (p < 0.05) in sensitivity. CONCLUSION: It was concluded that there is a significant difference between age groups in estimating instrument damage. Also, it was noted that the damage assessment with the naked eye and optical aids were different. Finally, in terms of ease of damage recognition, significant differences between the types of engine-driven endodontic instruments were found. However, no type of instrument was more prone to damage than any other type of instrument.

20.
J Dent ; 112: 103751, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34298114

RESUMO

OBJECTIVES: We assessed the long-term cost-effectiveness of glass hybrid (GH) versus composite (CO) for restoring permanent molars using a health economic modelling approach. METHODS: A multi-national (Croatia, Serbia, Italy, Turkey) split-mouth randomized trial comparing GH and CO in occlusal-proximal two-surfaced cavities in permanent molars (n=180/360 patients/molars) provided data on restoration failure and allocation probabilities (i.e. failure requiring re-restoration, repair or endodontic therapy). Using Markov modelling, we followed molars over the lifetime of an initially 12-years-old individual. Our health outcome was the time a tooth was retained. A mixed-payers' perspective within German healthcare was used to determine costs (in Euro 2018) using fee item catalogues. Monte-Carlo-microsimulations, univariate and probabilistic sensitivity analyses were conducted. Incremental cost-effectiveness ratios (ICER)s and cost-effectiveness-acceptability were quantified. RESULTS: In the base-case scenario, CO was more effective (tooth retention for a mean (SD) 54.4 (1.7) years) but also more costly (694 (54) Euro) than GH (53.9 (1.7) years; 614 (56 Euro). The ICER was 158 Euro/year, i.e. payers needed to be willing to invest 158 Euro per additional year of tooth retention when using CO. In a sensitivity analysis, this finding was confirmed or GH found more effective and less costly. CONCLUSION: CO was more costly and limitedly more effective than GH, and while there is uncertainty around our findings, GH is likely a cost-effectiveness option for restoring permanent molars. CLINICAL SIGNIFICANCE: When considering the long-term (life-time) cost-effectiveness, GH showed cost savings but CO was limitedly more effective. Overall, cost-effectiveness differences seems limited or in favour of GH.


Assuntos
Cárie Dentária , Dente Molar , Criança , Análise Custo-Benefício , Atenção à Saúde , Vidro , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA