Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sci Rep ; 7(1): 15398, 2017 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-29133943

RESUMO

Diode-pumped solid-state micro lasers are compact (centimetre-scale), highly stable, and efficient. Previously, we reported Q-switched lasers incorporating rare-earth substituted iron garnet (RIG) film. Here, the first demonstration of the magnetooptical (MO) Q-switch in an Nd:YAG laser cavity is performed. We fabricate a quasi-continuous-wave (QCW) diode-pumped Nd:YAG laser cavity, which is shortened to 10 mm in length and which contains an RIG film and a pair of small coils. This cavity yields a 1,064.58-nm-wavelength pulse with 25-ns duration and 1.1-kW peak power at a 1-kHz repetition ratio. Further, the polarisation state is random, due to the isotropic crystal structure of Nd:YAG and the fact that the MO Q-switch incorporating the RIG film does not require the presence of polarisers in the cavity. This is also the first report of an MO Q-switch producing random polarisation.

2.
Sci Rep ; 6: 38679, 2016 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-27929119

RESUMO

A 10-mm cavity length magnetooptically Q-switched Nd:GdVO4 laser was demonstrated using a single-crystalline ferrimagnetic rare-earth iron garnet film. To design the Q-switching system, the magnetic, optical, and magnetooptical properties of the garnet film were measured. The diode pumped solid-state laser cavity was constructed using a 190-µm-thick garnet film with 58% transmittance. The garnet film had maze-shaped magnetic domains, and the domain walls disappeared when a field of over 200 Oe was applied. Therefore, the polarization state of the transmitted light was modified by modulating the magnetization, and a Q-switched pulse output with a pulse width of 5 ns and peak power of 255 W was achieved in the 10-mm-long cavity. The physical limitation of the pulse width was discussed with the calculated results.

3.
Opt Express ; 24(16): 17635-43, 2016 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-27505732

RESUMO

High-power giant pulses can be used applied in various applications with Q-switched micro-lasers. This method can shorten the pulse duration; however, active control is currently impossible in micro-lasers. To achieve precise pulse control while maintaining compactness and simplicity, we exploit the magneto-optical effect in magnetic garnet films with micromagnetic domains that can be actively controlled by a pulsed magnetic field. Our Q-switching technique enhances the output power by a factor of 4 × 103. Moreover, the device itself is smaller than other Q-switching devices. This novel type of active Q-switch can be combined with a micro-laser to obtain megawatt-order pulses.

4.
J Magn Reson Imaging ; 27(4): 891-7, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18383250

RESUMO

PURPOSE: To investigate the source of native low-frequency fluctuations (LFF) in functional MRI (fMRI) signal. MATERIALS AND METHODS: Phase analysis was performed on tissue-segmented fMRI data acquired at systematically varying sampling rates. RESULTS: LFF in fMRI signal were both native and aliased in origin. Scanner instability did not contribute to native or aliased LFF. Aliased LFF arose from cardiorespiratory processes and head motion. Native LFF did not arise from cardiorespiratory processes, but did so, at least in part, from head motion. Motion correction reduced native LFF, but did not eliminate them. The residual native LFF in motion-corrected fMRI data showed a systematic phase difference among different tissue structures. The native LFF in fMRI signals of cerebral blood vessels and CSF were synchronous, and preceded those of gray and white matter, indicating that the vascular fluctuations lead the metabolic fluctuations. CONCLUSION: The primary physiologic source of native LFF in fMRI signal is vasomotion.


Assuntos
Encéfalo/fisiologia , Circulação Cerebrovascular , Imageamento por Ressonância Magnética , Adolescente , Adulto , Humanos , Interpretação de Imagem Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA