Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Int J Cardiol ; 389: 131176, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37442350

RESUMO

OBJECTIVES: Confirming the prognostic value of global QFR and evaluating the long-term prognosis of QFR-concordant therapy in stable coronary artery disease. BACKGROUND: Wire-based functional evaluation of coronary disease is linked to patient's prognosis. Quantitative Flow Ratio (QFR) is a newer index of computational physiology, linked to clinical outcomes and prognosis at 1 year follow-up. Long-term prognosis of QFR-concordant revascularization in stable coronary artery disease is however unknown hitherto. METHODS: Consecutive patients with stable coronary disease undergoing coronary angiography were included. Centralized and blinded QFR analysis of three coronary territories was performed. Three vessel QFR (3vQFR) was defined as the sum of the basal QFR of each coronary territory. QFR-concordant revascularization was met if all significant lesions (QFR ≤ 0.80) were revascularized and all non-significant lesions (QFR > 0.80) were not; otherwise, the case was defined as QFR-discordant revascularization. Patient-oriented composite end-point (POCE) of cardiac death, myocardial infarction and unscheduled revascularization was the primary endpoint. RESULTS: A total of 803 patients from six high-volume centers were included. Canadian Cardiovascular Society (CCS) class II angina was the most frequent (48.9%) clinical presentation. Median of follow-up was 68.8 months. 3vQFR was an independent predictor of POCE (HR 1.79 CI95% 1.01-3.18), with 2.75 as optimal cut-off value, irrespective of the therapy received. QFR-discordant revascularization (QFR+/Revascularization- or QFR-/Revascularization+) was an independent predictor of POCE in multivariate analysis (HR 1.65, CI 95% 1.03-2.64). CONCLUSION: Global burden of epicardial coronary atherosclerosis, as evaluated by 3vQFR, as well as QFR-discordant therapy are independent predictors of adverse clinical outcome at long-term follow-up in stable coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Prognóstico , Vasos Coronários , Canadá , Angiografia Coronária , Valor Preditivo dos Testes , Resultado do Tratamento
3.
Cardiovasc Revasc Med ; 21(1): 52-60, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31326258

RESUMO

BACKGROUND: Functional mitral regurgitation (FMR) is a common finding among patients with heart failure (HF) and it is related to adverse events. Outcomes in patients undergoing transcatheter mitral valve repair (TMVR) are still a matter of debate. We performed a meta-analysis to assess mid- and long-term outcomes of patients with FMR treated with MitraClip® compared to medical management. METHODS: We conducted an electronic database search of all published data PubMed Central, Embase, the Cochrane Central Register of Controlled Trials, ClinicalTrials.gov, and Google Scholar databases. The primary end-point was all-cause mortality. The secondary end-points were hospitalizations for HF, need for heart transplantation or left ventricular assist device, unplanned mitral valve surgery, myocardial infarction and stroke. RESULTS: Five studies (n = 1513 patients) were included in the analysis. The summary estimate including all the available studies showed a statistically significant reduction in all-cause mortality favoring MitraClip® (HR 0.56, CI 95% [0.38-0.84]) and HF hospitalizations (HR 0.65; CI 95% [0.46-0.92]). A significant reduction in the indication for advanced HF therapies (OR 0.48; CI 95% [0.25-0.90]) or the need for unplanned mitral valve surgery (OR 0.20; CI 95% [0.07-0.57]) was also found in the group of patients that underwent TMVR. No differences in the incidence of myocardial infarction or stroke were found between both groups of treatment. No publication bias was detected. CONCLUSION: TMVR with MitraClip® system was related to a significant reduction in all-cause mortality, hospitalizations for HF and the need for HF transplant, left ventricular assist device or unplanned surgery beyond 1-year follow up.


Assuntos
Cateterismo Cardíaco/instrumentação , Fármacos Cardiovasculares/uso terapêutico , Insuficiência Cardíaca/terapia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Causas de Morte , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA