1.
Radiat Prot Dosimetry ; 189(2): 198-204, 2020 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-32195553

RESUMO

Cytogenetic biodosimetry is a well-known method for quantifying the absorbed dose based on measuring biological radiation effects. To correlate the induced chromosomal abberrations with the absorbed dose of the individuals, a reliable dose-response calibration curve should be established. This study aimed to use frequencies and distributions of radiation-induced dicentric chromosome aberrations to develop a standard dose-response calibration curve. Peripheral blood samples taken from six male donors irradiated by an X-ray generator up to 4 Gy were studied. Three different blood samples were irradiated by known doses, then scored blindly for verification of the proposed calibration curve. Dose estimation was also carried out for three real overexposed cases. The results showed good accordance with the other published curves. The constructed dose-response curve provides a reliable tool for biological dosimetry in accidental or occupational radiation exposures.


Assuntos
Aberrações Cromossômicas , Radiometria , Calibragem , Relação Dose-Resposta à Radiação , Humanos , Linfócitos , Masculino , Raios X
2.
Appl Radiat Isot ; 90: 89-93, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24705011

RESUMO

Water equivalent ratio (WER) was calculated for different proton energies in polymethyl methacrylate (PMMA), polystyrene (PS) and aluminum (Al) using FLUKA and SRIM codes. The results were compared with analytical, experimental and simulated SEICS code data obtained from the literature. The biggest difference between the codes was 3.19%, 1.9% and 0.67% for Al, PMMA and PS, respectively. FLUKA and SEICS had the greatest agreement (≤0.77% difference for PMMA and ≤1.08% difference for Al, respectively) with the experimental data.


Assuntos
Alumínio/química , Água Corporal/química , Polimetil Metacrilato/química , Poliestirenos/química , Terapia com Prótons , Radiometria/métodos , Software , Absorção de Radiação , Materiais Biomiméticos/química , Simulação por Computador , Humanos , Teste de Materiais , Modelos Biológicos , Modelos Químicos , Modelos Estatísticos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade