Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
2.
J Artif Organs ; 22(4): 353-356, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31236730

RESUMO

The purpose of this study was to assess the accuracy and reliability of a continuous blood glucose monitoring system (artificial endocrine pancreas; STG-55, Nikkiso, Tokyo, Japan) during pediatric cardiopulmonary bypass surgery. Twenty-five pediatric patients scheduled to undergo cardiovascular surgery with cardiopulmonary bypass (age 4 months to 11 years; body weight 5.6-59.7 kg) were enrolled. The glucose sensor line of the artificial endocrine pancreas was connected to the venous side of the cardiopulmonary bypass circuit and used for continuous blood glucose monitoring. We obtained 192 samples for blood gas assessment from the cardiopulmonary bypass circuit, and i-STAT (Abbott, East Windsor, NJ, USA) was used for conventional blood glucose assessment. The accuracies of continuous glucose measurements (STG-55) and conventional intermittent glucose measurements (i-STAT) during cardiopulmonary bypass were compared by means of Clarke error grid analysis. The results were divided into five zones, A, B, C, D, and E, and 78.6% of paired measurements were in zone A, while 21.4% were in zone B. We confirmed that the results of this continuous blood glucose monitoring system for cardiopulmonary bypass during pediatric cardiovascular surgery were highly reliable. An artificial endocrine pancreas may facilitate the safe use of intensive insulin therapy during pediatric cardiovascular surgery.


Assuntos
Glicemia/metabolismo , Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar/métodos , Cardiopatias Congênitas/cirurgia , Sistemas de Infusão de Insulina , Monitorização Intraoperatória/métodos , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/sangue , Humanos , Insulina/sangue , Masculino , Reprodutibilidade dos Testes
3.
J Med Invest ; 64(3.4): 311-312, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28955004

RESUMO

The patient, a 70-year-old Japanese woman diagnosed with parotid gland cancer, underwent wide excision and reconstruction (facial nerve ablation, nerve transposition). At 1 month after the surgery, she was brought to our hospital's pain medicine department because her postoperative pain and cancer-related pain were poorly controlled. She had already been prescribed a tramadol (37.5 mg)/acetaminophen (325 mg) combination tablet (5 tablets/day). However, in addition to the continuous pain in her face and lower limbs, she was troubled by a trigeminal neuralgia-like prominence ache. Because this pain could not be controlled by an increase to eight combination tablets per day, we switched her medication to a tramadol capsule. At 11 months post-surgery, we then switched her medication to an orally disintegrating tramadol tablet to improve medication adherence of the drug. From 14 months post-surgery, the patient also used a sustained-release tramadol preparation, and she was then able to sleep well. Her current regimen is an orally disintegrating sustained-release tablet combination (total 300 mg tramadol) per day, and she achieved sufficient pain relief. Because tramadol is not classified as a medical narcotic drug, it widely available and was shown here to be extremely useful for the treatment of our patient's mixed (mainly cancer) pain. J. Med. Invest. 64: 311-312, August, 2017.


Assuntos
Analgésicos Opioides/uso terapêutico , Dor do Câncer/tratamento farmacológico , Tramadol/uso terapêutico , Idoso , Feminino , Humanos
4.
J Artif Organs ; 20(1): 76-83, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27557726

RESUMO

The aim of the present study was to evaluate the usefulness of a closed-loop system (STG-55; Nikkiso, Tokyo, Japan), a type of artificial endocrine pancreas for the continuous monitoring and control of intraoperative blood glucose, for preventing postoperative acute kidney injury (AKI) in patients undergoing hepatectomy. Thirty-eight patients were enrolled in this study. Glucose concentrations were controlled with either a manual injection of insulin based on a commonly used sliding scale (manual insulin group, n = 19) or the programmed infusion of insulin determined by the control algorithm of the artificial endocrine pancreas (programmed insulin group, n = 19). After the induction of anesthesia, a 20-G intravenous catheter was inserted into the peripheral forearm vein of patients in the programmed insulin group and connected to an artificial endocrine pancreas (STG-55). The target range for glucose concentrations was set to 100-150 mg/dL. The mean serum creatinine concentrations of preoperative, postoperative 24 and 48 h were 0.72, 0.78, and 0.79 mg/dL in the programmed insulin group, and 0.81, 0.95, and 1.03 mg/dL in the manual insulin group, respectively. Elevations in serum creatinine concentrations postoperative 48 h were significantly suppressed in the programmed insulin group. The STG-55 closed-loop system was effective for maintaining strict blood glucose control during hepatectomy with minimal variability in blood glucose concentrations and for suppressing elevations in serum creatinine concentrations. Strict blood glucose control by an artificial endocrine pancreas during hepatectomy may prevent postoperative AKI.


Assuntos
Injúria Renal Aguda/prevenção & controle , Glicemia/análise , Hepatectomia/efeitos adversos , Pâncreas Artificial , Complicações Pós-Operatórias/prevenção & controle , Injúria Renal Aguda/etiologia , Idoso , Idoso de 80 Anos ou mais , Creatinina , Feminino , Humanos , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Japão , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
5.
J Anesth ; 29(6): 836-41, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26210166

RESUMO

PURPOSE: Postoperative nausea and vomiting (PONV) is the most common complication after surgery, and opioid administration increases its incidence. We compared the preventive effects of fosaprepitant, a neurokinin-1 (NK1) receptor antagonist, with those of ondansetron on PONV in patients who underwent lower limb surgery with postoperative epidural opioid administration. METHODS: This prospective, double-blind, randomized study included 38 patients who underwent lower limb surgery. They were randomly allocated to receive intravenous fosaprepitant 150 mg (n = 19; NK1 group) or ondansetron 4 mg (n = 19; ONS group) before general anesthesia. All patients received postoperative epidural fentanyl for pain control. The incidence of nausea and vomiting, complete response rate (no vomiting and no rescue antiemetic use), rescue antiemetic use, nausea score (0-3), and visual analog scale (VAS 0-10) score for pain were recorded at 2, 24, and 48 h after surgery. RESULTS: No patient in the NK1 group experienced vomiting (0%) during the first 24 and 48 h after surgery, while 5 of 19 (26%) patients in the ONS group experienced this complication, indicating a significant difference between groups. There were no significant differences in the incidence of PONV, complete response rate, rescue antiemetic use, nausea score, and VAS score for pain between the NK1 and ONS groups during the study period. CONCLUSIONS: Fosaprepitant was more effective than ondansetron in decreasing the incidence of vomiting after lower limb surgery with postoperative opioid administration. Meanwhile, fosaprepitant was not inferior to ondansetron in decreasing the incidence and severity of PONV.


Assuntos
Antieméticos/uso terapêutico , Morfolinas/uso terapêutico , Ondansetron/uso terapêutico , Náusea e Vômito Pós-Operatórios/prevenção & controle , Administração Intravenosa , Adulto , Idoso , Anestesia Geral/métodos , Método Duplo-Cego , Feminino , Humanos , Extremidade Inferior/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
6.
J Med Invest ; 62(1-2): 41-4, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25817282

RESUMO

BACKGROUND: Recent studies have shown that strict perioperative blood glucose management may reduce mortality and morbidity in critically ill adult patients. The purpose of this study was to assess the accuracy and efficacy of the intraoperative application of a newly developed, next-generation artificial endocrine pancreas (STG-55, Nikkiso Co., Ltd., Tokyo, Japan). METHODS: Twenty patients scheduled to undergo surgery were enrolled in this study. The STG-55 is designed to be more user-friendly than its conventional counterpart (STG-22) while maintaining the latter's fundamental functions, such as a closed-loop system using algorithms for insulin and glucose infusion. After anesthetic induction, a 20G intravenous catheter was inserted into a peripheral forearm vein and connected to a continuous blood glucose monitor. The resultant 105 scores for paired blood glucose values were compared by Bland-Altman analysis. RESULTS: Stable blood glucose values were maintained automatically, and there were no complications related to use of the STG-55. A close correlation (r=0.96) was observed between continuous glucose measurements using the STG-55 and conventional intermittent glucose measurements. The difficulty of manipulation using this system was decreased by improved preparation procedures. CONCLUSION: The glycemic control system using the STG-55 could provide an alternative way to achieve effective and safe perioperative glycemic control.


Assuntos
Pâncreas Artificial , Idoso , Idoso de 80 Anos ou mais , Engenharia Biomédica , Glicemia/metabolismo , Desenho de Equipamento , Feminino , Humanos , Sistemas de Infusão de Insulina , Japão , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória
7.
J Med Invest ; 61(3-4): 278-84, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25264045

RESUMO

BACKGROUND: Propofol causes vasodilation via endothelium-dependent and -independent mechanisms. Because endothelial function is impaired with aging, the effects of propofol on endothelium-dependent vasodilation might be altered by aging. The aim of this study was thus to determine the effects of aging on vascular responses to propofol. METHODS: Young (4-6 weeks old) or adult (16-25 weeks old) rats were anesthetized with sevoflurane. The thoracic aorta was dissected and cut into pieces 3-4 mm in length. In some rings, the endothelium was deliberately removed. The ring segment of the aorta was mounted for isometric force recording at a resting tension of 0.5-1.0 g in a 2 ml organ bath, containing Krebs-Ringer bicarbonate buffer. Arteries were precontracted with phenylephrine, and the function of endothelium was confirmed with acetylcholine. Then, we studied the concentration-dependent effects of propofol in endothelium-intact (control group) and -denuded aortic rings (denuded group), as well as those treated with N(ω)-nitro-L-arginine methylester (L-NAME group). RESULTS: Relaxation due to propofol was observed in the control groups of both young and adult rats in a concentration-dependent manner, but the magnitude of relaxation was significantly greater in young rats. In addition, in young rats, relaxation due to propofol was significantly and equally reduced in both L-NAME and denuded groups at all propofol concentrations that we studied (10(-6)-10(-3) M). In adult rats, relaxation due to propofol was quite similar between control and L-NAME groups at all propofol concentrations, whereas it was significantly reduced in the denuded group. CONCLUSION: These results suggest that endothelium-derived nitric oxide plays an important role in propofol-induced vasodilation in young rats, but not in adult rats.


Assuntos
Envelhecimento/fisiologia , Anestésicos Intravenosos/farmacologia , Aorta Torácica/efeitos dos fármacos , Propofol/farmacologia , Vasodilatação/efeitos dos fármacos , Animais , Aorta Torácica/fisiologia , Masculino , NG-Nitroarginina Metil Éster/farmacologia , Óxido Nítrico/fisiologia , Ratos , Ratos Wistar
8.
J Med Invest ; 61(3-4): 421-5, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25264066

RESUMO

A 71-year-old woman had an episode of syncope due to hypoglycemia of 27 mg/dl. She was diagnosed with insulinoma and scheduled for laparoscopic enucleation along with the use of an artificial endocrine pancreas (STG-22, Nikkiso Co., Ltd., Tokyo, Japan). Anesthesia was maintained with sevoflurane and remifentanil. Her blood glucose level was controlled using the artificial endocrine pancreas, which enabled continuous blood glucose monitoring and computer-operated glucose and insulin infusion to maintain the blood glucose level at a steady state. The target concentration of blood glucose was set at 80-120 mg/dl during surgery. Until removal of the tumor, the blood glucose level was kept at around 80-100 mg/dl. After removal of the tumor, the blood glucose level gradually increased, but it was kept in the normal range by the artificial endocrine pancreas. The artificial endocrine pancreas was useful to monitor and maintain blood glucose levels during and after the removal of insulinoma, without any hyper- or hypoglycemia.


Assuntos
Sistemas de Infusão de Insulina , Insulinoma/cirurgia , Neoplasias Pancreáticas/cirurgia , Idoso , Glicemia/análise , Feminino , Humanos
9.
J Med Invest ; 60(3-4): 205-12, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24190037

RESUMO

BACKGROUND: The purpose of this study was to evaluate the usefulness of the closed-loop system (STG-22; Nikkiso, Tokyo, Japan), a type of artificial endocrine pancreas for the continuous monitoring and control of intraoperative blood glucose in patients undergoing liver transplantation. METHODS: Sixteen patients undergoing living-donor liver transplantation were enrolled in this study. Glucose levels were controlled with either a manual injection of insulin based on a commonly used sliding scale (manual insulin group, n=8) or a programmed infusion of insulin determined by the control algorithm of the artificial endocrine pancreas (programmed insulin group, n=8). The target glucose level range was set at 80-150 mg/dl. RESULTS: The mean and SD of blood glucose concentration during surgery (Glu-Ave and Glu-SD, respectively) for the programmed insulin group were lower than for the manual insulin group. The coefficient of variability (Glu-CV=Glu-SD×100 /Glu-Ave) for the programmed insulin group was also lower than for the manual insulin group (20.1±4.9% vs. 26.9±6.1%; mean±SD). No hypoglycemia was detected in either group. CONCLUSION: The STG-22 closed-loop system is effective for maintaining strict blood glucose control during liver transplantation with minimal variability in blood glucose concentration.


Assuntos
Glicemia/análise , Sistemas de Infusão de Insulina , Transplante de Fígado , Adulto , Feminino , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Reprodutibilidade dos Testes
10.
J Med Invest ; 60(3-4): 272-5, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24190047

RESUMO

A PediaSat™ oximetry catheter (PediaSat: Edwards Lifesciences Co., Ltd., Irvine, CA, U. S. A.), which facilitates continuous measurement of central venous oxygen saturation (ScvO2), may be useful for surgery for pediatric congenital heart disease. We used PediaSat during a bidirectional Glenn shunt. The patient was a 13-month-old boy. Under a diagnosis of left single ventricle (pulmonary atresia, right ventricular hypoplasia, atrial septal defect) and residual left aortic arch/left superior vena cava, a modified right Blalock-Taussig shunt was performed. Cyanosis deteriorated, so a bidirectional Glenn shunt was scheduled. After anesthesia induction, a 4.5 Fr double-lumen (8 cm) PediaSat was inserted through the right internal jugular vein for continuous ScvO2 monitoring. Furthermore, the probe of a near-infrared, mixed blood oxygen saturation-measuring monitor was attached to the forehead for continuous monitoring of the regional brain tissue mixed blood oxygen saturation (rSO2) (INVOS™ 5100C, Covidien; Boulder, CO, U. S. A.). Blockage of the right pulmonary artery and right superior vena cava decreased the oxygen saturation, ScvO2, and rSO2, but increased the central venous pressure. Although changes in ScvO2 were parallel to those in rSO2, the former showed more marked changes. A combination of ScvO2 and rSO2 for monitoring during Glenn shunt may be safer.


Assuntos
Técnica de Fontan/métodos , Cardiopatias Congênitas/sangue , Cardiopatias Congênitas/cirurgia , Oximetria/métodos , Monitorização Transcutânea dos Gases Sanguíneos , Cateterismo Venoso Central , Técnica de Fontan/instrumentação , Ventrículos do Coração/anormalidades , Ventrículos do Coração/cirurgia , Humanos , Lactente , Masculino , Monitorização Intraoperatória/instrumentação , Monitorização Intraoperatória/métodos , Oximetria/instrumentação
11.
J Artif Organs ; 16(4): 508-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23989924

RESUMO

We tried to perform continuous blood glucose monitoring during cardiovascular surgery involving cardiopulmonary bypass using an artificial endocrine pancreas (STG-22 or -55; Nikkiso, Tokyo, Japan); however, we often encountered problems during these procedures because insufficient blood was obtained for monitoring. Thus, we started performing the blood sampling via the venous side of the cardiopulmonary bypass circuit. As a result, continuous blood glucose monitoring using an artificial endocrine pancreas was proven to be stable and reliable during cardiovascular surgery involving cardiopulmonary bypass.


Assuntos
Pâncreas Artificial , Coleta de Amostras Sanguíneas , Ponte Cardiopulmonar , Humanos
12.
Masui ; 60(9): 1094-6, 2011 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-21950045

RESUMO

A 58-year-old man with hypertension underwent laparoscopic distal gastrectomy under general and epidural anesthesia. Preoperative laboratory date revealed a normal platelet count and normal coagulation profile. Epidural puncture was successfully performed at the T9-10 intervertebral space on the first attempt without bleeding. An epidural catheter was smoothly inserted 5 cm cephalad. On the third postoperative day, paraplegia due to thoracic epidural hematoma developed shortly after extraction of the catheter. At that time, his blood pressure was 190/102 mmHg because of a pain due to walk. On using a hypotensive drug, his blood pressure fell. Ten minutes later, paraplegia disappeared spontaneously. It is suggested that the spinal cord of the patient was subjected to transient pressure hematoma. A decline in blood pressure may have caused the blood to spread through the epidural space, such that the neurologic symptoms disappeared.


Assuntos
Anestesia Epidural/efeitos adversos , Hematoma Epidural Espinal/complicações , Paraplegia/etiologia , Cateterismo/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA