Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Oncology ; 101(9): 553-564, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37015204

RESUMO

BACKGROUND: Neoadjuvant chemotherapy (nCT) or chemoradiotherapy (nCRT) are accepted standards of care for the management of adenocarcinoma of the esophagus and gastroesophageal junction. SUMMARY: The MRC-OEO2 study established the role of 2 cycles of neoadjuvant cisplatin/fluoropyrimidine. More recently, the FLOT-AIO4 study demonstrated the superiority of perioperative FLOT chemotherapy (5FU, oxaliplatin, and docetaxel) compared to ECX (epirubicin, cisplatin, and capecitabine) regime. The results from the pivotal CROSS study established neoadjuvant CRT as a new standard of care in OG cancer. The survival benefits observed in FLOT and CROSS studies are similar [FLOT - hazard ratio 0.75 (0.62-0.92); CROSS - 0.741 (0.55-0.98)]. KEY MESSAGES: Both nCT and nCRT have been shown to be associated with survival benefit compared to surgery alone. We have performed a comprehensive review of the available evidence to define the optimum treatment algorithm and identify specific patient sub-groups who may be appropriate for the use of one or more of these neoadjuvant options.


Assuntos
Adenocarcinoma , Neoplasias Esofágicas , Neoplasias Gástricas , Humanos , Cisplatino , Terapia Neoadjuvante , Neoplasias Gástricas/patologia , Fluoruracila , Neoplasias Esofágicas/patologia , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Junção Esofagogástrica/patologia , Adenocarcinoma/patologia
2.
Neurosurgery ; 93(4): 910-917, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37057918

RESUMO

BACKGROUND: Transpedicular or transisthmic screws for C2 instrumentation represent the gold standard; however, the anatomy is not always compatible (hypoplastic pedicles, procidentia of the vertebral artery). Laminar screws (LS) have been proposed as a rescue technique and recently, bicortical facet screws (FS). To date, the biomechanical property of FS remains unknown. OBJECTIVE: To compare the pull-out resistance of bicortical facet (FS) vs laminar (LS) C2 screws. METHODS: Thirty-two human cadaveric C2 vertebrae were screened by CT scan imaging and dual x-ray absorptiometry before receiving both techniques and were randomized according to side and sequence (FS or LS first). Screw positioning was validated using 2-dimensional x-rays. Sixty-four mechanical tests were performed using pure tensile loading along the axis of the screws until pull-out. Mean pull-out strengths were compared using paired tests, multivariate and survival analysis (Kaplan-Meier curves). RESULTS: The morphometric data were consistent with previous studies. Over 64 tests, the mean pull-out strength of LS (707 ± 467 N) was significantly higher than that of FS (390 ± 230 N) ( P = .0004). Bone mineral density was weakly correlated with pull-out strength (r = 0.42 for FS and r = 0.3 for LS). Both techniques were mechanically equivalent for vertebrae in which intralaminar cortical grip was not achievable for LS. The mean pull-out strength for LS with laminar cortical grip (1071 ± 395 N) was significantly higher than that of LS without (423 ± 291 N) ( P < .0001). CONCLUSION: Our results suggest that bicortical FS of C2 offer less mechanical resistance than LS.


Assuntos
Densidade Óssea , Vértebras Cervicais , Humanos , Vértebras Cervicais/cirurgia , Parafusos Ósseos , Radiografia , Tomografia Computadorizada por Raios X , Fenômenos Biomecânicos , Cadáver
3.
Cancers (Basel) ; 13(22)2021 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-34830865

RESUMO

Major progress has been achieved to treat cancer patients and survival has improved considerably, even for stage-IV bone metastatic patients. Locomotive health has become a crucial issue for patient autonomy and quality of life. The centerpiece of the reflection lies in the fracture risk evaluation of bone metastasis to guide physician decision regarding physical activity, antiresorptive agent prescription, and local intervention by radiotherapy, surgery, and interventional radiology. A key mandatory step, since bone metastases may be asymptomatic and disseminated throughout the skeleton, is to identify the bone metastasis location by cartography, especially within weight-bearing bones. For every location, the fracture risk evaluation relies on qualitative approaches using imagery and scores such as Mirels and spinal instability neoplastic score (SINS). This approach, however, has important limitations and there is a need to develop new tools for bone metastatic and myeloma fracture risk evaluation. Personalized numerical simulation qCT-based imaging constitutes one of these emerging tools to assess bone tumoral strength and estimate the femoral and vertebral fracture risk. The next generation of numerical simulation and artificial intelligence will take into account multiple loadings to integrate movement and obtain conditions even closer to real-life, in order to guide patient rehabilitation and activity within a personalized-medicine approach.

4.
Proc Inst Mech Eng H ; 234(3): 247-254, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31648627

RESUMO

Cortical bone fracture mechanisms are well studied under quasi-static loading. The influence of strain rate on crack propagation mechanisms needs to be better understood, however. We have previously shown that several aspects of the bone micro-structure are involved in crack propagation, such as the complete porosity network, including the Haversian system and the lacunar network, as well as biochemical aspects, such as the maturity of collagen cross-links. The aim of this study is to investigate the influence of strain rate on the toughness of human cortical bone with respect to its microstructure and organic non-collagenous composition. Two strain rates will be considered: quasi-static loading (10-4 s-1), a standard condition, and a higher loading rate (10-1 s-1), representative of a fall. Cortical bone samples were extracted from eight female donors (age 50-91 years). Three-point bending tests were performed until failure. Synchrotron radiation micro-computed tomography imaging was performed to assess bone microstructure including the Haversian system and the lacunar system. Collagen enzymatic cross-link maturation was measured using a high performance liquid chromatography column. Results showed that that under quasi-static loading, the elastic contribution of the fracture process is correlated to both the collagen cross-links maturation and the microstructure, while the plastic contribution is correlated only to the porosity network. Under fall-like loading, bone organization appears to be less linked to crack propagation.


Assuntos
Osso Cortical/fisiologia , Estresse Mecânico , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Osso Cortical/citologia , Osso Cortical/diagnóstico por imagem , Osso Cortical/lesões , Feminino , Humanos , Pessoa de Meia-Idade , Microtomografia por Raio-X
5.
Bone ; 127: 526-536, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31362068

RESUMO

Human cortical bone has a complex hierarchical structure that is periodically remodelled throughout a lifetime. This microstructure dictates the mechanical response of the tissue under a critical load. If only some structural features, such as the different porosities observed in bone, are primarily studied, then investigations may not fully consider the osteonal systems in three-dimensions (3D). Currently, it is difficult to differentiate osteons from interstitial tissue using standard 3D characterization methods. Synchrotron radiation micro-computed tomography (SR-µCT) in the phase contrast mode is a promising method for the investigation of osteons. In the current study, SR-µCT imaging was performed on cortical bone samples harvested from eight human radii (female, 50-91 y.o.). The images were segmented to identify Haversian canals, osteocyte lacunae, micro-cracks, as well as osteons. The significant correlation between osteonal and Haversian canal volume fraction highlights the role of the canals as sites where bone remodelling is initiated. The results showed that osteocyte lacunae morphometric parameters depend on their distance to cement lines, strongly suggesting the evolution of biological activity from the beginning to the end of the remodelling process. Thus, the current study provides new data on 3D osteonal morphometric parameters and their relationships with other structural features in humans.


Assuntos
Osso Cortical/anatomia & histologia , Osso Cortical/diagnóstico por imagem , Ósteon/anatomia & histologia , Ósteon/diagnóstico por imagem , Imageamento Tridimensional , Rádio (Anatomia)/anatomia & histologia , Rádio (Anatomia)/diagnóstico por imagem , Densidade Óssea , Humanos , Tamanho do Órgão , Estresse Mecânico
6.
Acta Biomater ; 90: 254-266, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30922952

RESUMO

The strong dependence between cortical bone elasticity at the millimetre-scale (mesoscale) and cortical porosity has been evidenced by previous studies. However, bone is an anisotropic composite material made by mineral, proteins and water assembled in a hierarchical structure. Whether the variations of structural and compositional properties of bone affect the different elastic coefficients at the mesoscale is not clear. Aiming to understand the relationships between bone elastic properties and compositions and microstructure, we applied state-of-the-art experimental modalities to assess these aspects of bone characteristics. All elastic coefficients (stiffness tensor of the transverse isotropic bone material), structure of the vascular pore network, collagen and mineral properties were measured in 52 specimens from the femoral diaphysis of 26 elderly donors. Statistical analyses and micromechanical modeling showed that vascular pore volume fraction and the degree of mineralization of bone are the most important determinants of cortical bone anisotropic mesoscopic elasticity. Though significant correlations were observed between collagen properties and elasticity, their effects in bone mesoscopic elasticity were minor in our data. This work also provides a unique set of data exhibiting a range of variations of compositional and microstructural cortical bone properties in the elderly and gives strong experimental evidence and basis for further development of biomechanical models for human cortical bone. STATEMENT OF SIGNIFICANCE: This study reports the relationships between microstructure, composition and the mesoscale anisotropic elastic properties of human femoral cortical bone in elderly. For the first time, we provide data covering the complete anisotropic elastic tensor, the microstructure of cortical vascular porosity, mineral and collagen characteristics obtained from the same or adjacent samples in each donor. The results revealed that cortical vascular porosity and degree of mineralization of bone are the most important determinants of bone anisotropic stiffness at the mesoscale. The presented data gives strong experimental evidence and basis for further development of biomechanical models for human cortical bone.


Assuntos
Envelhecimento/metabolismo , Osso Cortical/metabolismo , Elasticidade , Fêmur/metabolismo , Idoso , Idoso de 80 Anos ou mais , Anisotropia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
J Biomech ; 85: 59-66, 2019 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-30686510

RESUMO

Human cortical bone fracture toughness depends on the anatomical locations under quasi-static loading. Recent results also showed that under fall-like loading, cortical bone fracture toughness is similar at different anatomical locations in the same donor. While cortical bone toughening mechanisms are known to be dependent on the tissue architecture under quasi-static loading, the fracture mechanisms during a fall are less studied. In the current study, the structural parameters of eight paired femoral diaphyses, femoral necks and radial diaphyses were mechanically tested under quasi-static and fall-like loading conditions (female donors, 70 ±â€¯14 y.o., [50-91 y.o.]). Synchrotron radiation micro-CT imaging was used to quantify the amount of micro-cracks formed during loading. The volume fraction of these micro-cracks was significantly higher within the specimens loaded under a quasi-static condition than under a loading representative of a fall. Under fall-like loading, there was no difference in crack volume fraction between the different paired anatomical locations. This result shows that the micro-cracking toughening mechanism depends both on the anatomical location and on the loading condition.


Assuntos
Osso Cortical/patologia , Diáfises/patologia , Pressão , Acidentes por Quedas , Idoso , Osso Cortical/diagnóstico por imagem , Diáfises/diagnóstico por imagem , Feminino , Fêmur/diagnóstico por imagem , Colo do Fêmur/diagnóstico por imagem , Fraturas Ósseas/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Rádio (Anatomia)/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Microtomografia por Raio-X
8.
J Struct Biol ; 204(2): 182-190, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30107234

RESUMO

Human bone is known to adapt to its mechanical environment in a living body. Both its architecture and microstructure may differ between weight-bearing and non-weight-bearing bones. The aim of the current study was to analyze in three dimensions, the morphology of the multi-scale porosities on human cortical bone at different locations. Eight paired femoral diaphyses, femoral necks, and radial diaphyses were imaged using Synchrotron Radiation µCT with a 0.7 µm isotropic voxel size. The spatial resolution facilitates the investigation of the multiscale porosities of cortical bone, from the osteonal canals system down to the osteocyte lacunar system. Our results showed significant differences in the microstructural properties, regarding both osteonal canals and osteocytes lacunae, between the different anatomical locations. The radius presents significantly lower osteonal canal volume fraction and smaller osteonal canals than the femoral diaphysis or neck. Osteocytes lacunae observed in the radius are significantly different in shape than in the femur, and lacunar density is higher in the femoral neck. These results show that the radius, a non-weight-bearing bone, is significantly different in terms of its microstructure from a weight-bearing bone such as the femur. This implies that the cortical bone properties evaluated on the femoral diaphysis, the main location studied within the literature, cannot be generalized to other anatomical locations.


Assuntos
Osso Cortical/anatomia & histologia , Osso Cortical/diagnóstico por imagem , Colo do Fêmur/anatomia & histologia , Colo do Fêmur/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Ósteon/anatomia & histologia , Ósteon/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Microtomografia por Raio-X
9.
Bone ; 112: 202-211, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29730278

RESUMO

Human cortical bone fracture processes depend on the internal porosity network down to the lacunar length scale. Recent results show that at the collagen scale, the maturation of collagen cross-links may have a negative influence on bone mechanical behavior. While the effect of pentosidine on human cortical bone toughness has been studied, the influence of mature and immature enzymatic cross-links has only been studied in relation to strength and work of fracture. Moreover, these relationships have not been studied on different paired anatomical locations. Thus, the aim of the current study was to assess the relationships between both enzymatic and non-enzymatic collagen cross-links and human cortical bone toughness, on four human paired anatomical locations. Single Edge Notched Bending toughness tests were performed for two loading conditions: a quasi-static standard condition, and a condition representative of a fall. These tests were done with 32 paired femoral diaphyses, femoral necks and radial diaphyses (18 women, age 81 ±â€¯12 y.o.; 14 men, age 79 ±â€¯8 y.o.). Collagen enzymatic and non-enzymatic crosslinks were measured on the same bones. Maturation of collagen was defined as the ratio between immature and mature cross-links (CX). The results show that there was a significant correlation between collagen cross-link maturation and bone toughness when gathering femoral and radial diaphyses, but not when considering each anatomical location individually. These results show that the influence of collagen enzymatic and non-enzymatic cross-links is minor when considering human cortical bone crack propagation mechanisms.


Assuntos
Colágeno/metabolismo , Osso Cortical/fisiologia , Fraturas Ósseas/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos/fisiologia , Feminino , Humanos , Masculino , Estresse Mecânico
10.
Ultrasonics ; 84: 119-125, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29112910

RESUMO

The characterization of brain tissue is crucial to better understand neurological disorders. Mechanical characterization is an emerging tool in that field. The purpose of this work was to validate a transient ultrasound technique aimed at measuring dispersion of mechanical parameters of the brain tissue. The first part of this work was dedicated to the validation of that technique by comparing it with two proven rheology methods: a rotating plate rheometer, and a viscoelastic spectroscopy apparatus. Experiments were done on tissue mimicking gels. Results were compared on storage and loss modulus in the 20-100 Hz band. Our method was validated for the measurement of storage modulus dispersion, with some reserves on the measurement of loss modulus. The second part of this work was the measurement of the mechanical characteristics of ex vivo human white matter. We were able to measure the dispersion of the storage and loss modulus in the 20-100 Hz band, fitting the data with a custom power law model.


Assuntos
Encéfalo/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Reologia/métodos , Fenômenos Biomecânicos , Módulo de Elasticidade , Elasticidade , Desenho de Equipamento , Humanos , Técnicas In Vitro , Imagens de Fantasmas , Resistência ao Cisalhamento , Estresse Mecânico
11.
J Mech Behav Biomed Mater ; 71: 223-230, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28360020

RESUMO

Bone fracture is a major health issue worldwide and consequently there have been extensive investigations into the fracture behavior of human cortical bone. However, the fracture properties of human cortical bone under fall-like loading conditions remains poorly documented. Further, most published research has been performed on femoral diaphyseal bone, whereas it is known that the femoral neck and the radius are the most vulnerable sites to fracture. Hence, the aim of this study is to provide information on human cortical bone fracture behavior by comparing different anatomical sites including the radius and the femoral neck acquired from 32 elderly subjects (50 - 98 y.o.). In order to investigate the intrinsic fracture behavior of human cortical bone, toughness experiments were performed at two different strain rates: standard quasi-static conditions, and a higher strain rate representative of a fall from a standing position. The tests were performed on paired femoral neck, femoral, tibial and radius diaphyseal samples. Linear elastic fracture toughness and the non-linear J-integral method were used to take into account both the elastic and non-elastic behavior of cortical bone. Under quasi-static conditions, the radius presents a significantly higher toughness than the other sites. At the higher strain rate, all sites showed a significantly lower toughness. Also, at the high strain rate, there is no significant difference in fracture properties between the four anatomical sites. These results suggest that regardless of the anatomical site (femur, femoral neck, tibia and radius), the bone has the same fracture properties under fall loading conditions. This should be considered in biomechanical models under fall-like loading conditions.


Assuntos
Osso Cortical/patologia , Fraturas Ósseas , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Elasticidade , Fêmur , Humanos , Pessoa de Meia-Idade , Rádio (Anatomia)
12.
Eur J Orthop Surg Traumatol ; 26(7): 785-91, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27170334

RESUMO

INTRODUCTION: The Harms technique is now considered as the gold standard to stabilize C1-C2 cervical spine. It has been reported to decrease the risk of vertebral artery injury. However, the risk of vascular injury does not totally disappear, particularly due to the proximity of the trans-isthmic C2 screw with the foramen transversarium of C2. In order to decrease this risk of vertebral artery injury, it has been proposed to use a shorter screw which stops before the foramen transversarium. OBJECT: The main objective was to compare the pull-out strength of long trans-isthmic screw (LS) versus short isthmic screw (SS) C2 screw. An additional morphological study was also performed. METHOD: Thirteen fresh-frozen human cadaveric cervical spines were included in the study. Orientation, width and height of the isthmus of C2 were measured on CT scan. Then, 3.5-mm titanium screws were inserted in C2 isthmus according to the Harms technique. Each specimen received a LS and a SS. The side and the order of placement were determined with a randomization table. Pull-out strengths and stiffness were evaluated with a testing machine, and paired samples were compared using Wilcoxon signed-rank test and also the Kaplan-Meier method. RESULTS: The mean isthmus transversal orientation was 20° ± 6°. The mean width of C2 isthmus was less than 3.5 mm in 35 % of the cases. The mean pull-out strength for LS was 340 ± 85 versus 213 ± 104 N for SS (p = 0.004). The mean stiffness for the LS was 144 ± 40 and 97 ± 54 N/mm for the SS (p = 0.02). DISCUSSION: The pull-out strength of trans-isthmic C2 screws was significantly higher (60 % additional pull-out resistance) than SSs. Although associated with an inferior resistance, SSs may be used in case of narrow isthmus which contraindicates 3.5-mm screw insertion but does not represent the first option for C2 instrumentation. LEVEL OF EVIDENCE: Level V.


Assuntos
Parafusos Ósseos , Vértebras Cervicais/anatomia & histologia , Fenômenos Biomecânicos , Cadáver , Vértebras Cervicais/fisiologia , Vértebras Cervicais/cirurgia , Humanos , Desenho de Prótese , Falha de Prótese , Implantação de Prótese/métodos , Manejo de Espécimes , Tomografia Computadorizada por Raios X
13.
J Orthop Sci ; 21(4): 487-492, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27183889

RESUMO

PURPOSE: Implants endurance as well as a good clinical tolerance depends on the recovery of a physiological stress distribution within bone after implantation. The purpose of the present work was to develop an alternative technique using Force Sensing Resistors (FSR) to gather in vitro pressure values at the implant-bone interface for a cementless implant. METHOD: Eight cementless femoral stems were instrumented with six calibrated FSR bonded on each facet and then implanted in eight cadaver femurs. Compression tests were performed until failure and FSR pressure values were recorded. RESULTS: The average failure load was 4241 N. The maximum contact pressure measured with the FSR averaged 1.965 MPa. CONCLUSION: FSR reached many of the requirements for an ideal implant-bone interfacial sensor. This experimentation provided in vitro quantitative data on contact pressure at the implant-bone interface, which could help understanding stress shielding phenomenon and developing relevant numerical model.


Assuntos
Fêmur/cirurgia , Prótese de Quadril , Desenho de Prótese , Suporte de Carga , Idoso , Idoso de 80 Anos ou mais , Cadáver , Fêmur/fisiopatologia , Humanos , Pessoa de Meia-Idade , Estresse Mecânico
14.
Radiology ; 280(3): 837-47, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27077380

RESUMO

Purpose To evaluate the performance of three imaging methods (radiography, dual-energy x-ray absorptiometry [DXA], and quantitative computed tomography [CT]) and that of a numerical analysis with finite element modeling (FEM) in the prediction of failure load of the proximal femur and to identify the best densitometric or geometric predictors of hip failure load. Materials and Methods Institutional review board approval was obtained. A total of 40 pairs of excised cadaver femurs (mean patient age at time of death, 82 years ± 12 [standard deviation]) were examined with (a) radiography to measure geometric parameters (lengths, angles, and cortical thicknesses), (b) DXA (reference standard) to determine areal bone mineral densities (BMDs), and (c) quantitative CT with dedicated three-dimensional analysis software to determine volumetric BMDs and geometric parameters (neck axis length, cortical thicknesses, volumes, and moments of inertia), and (d) quantitative CT-based FEM to calculate a numerical value of failure load. The 80 femurs were fractured via mechanical testing, with random assignment of one femur from each pair to the single-limb stance configuration (hereafter, stance configuration) and assignment of the paired femur to the sideways fall configuration (hereafter, side configuration). Descriptive statistics, univariate correlations, and stepwise regression models were obtained for each imaging method and for FEM to enable us to predict failure load in both configurations. Results Statistics reported are for stance and side configurations, respectively. For radiography, the strongest correlation with mechanical failure load was obtained by using a geometric parameter combined with a cortical thickness (r(2) = 0.66, P < .001; r(2) = 0.65, P < .001). For DXA, the strongest correlation with mechanical failure load was obtained by using total BMD (r(2) = 0.73, P < .001) and trochanteric BMD (r(2) = 0.80, P < .001). For quantitative CT, in both configurations, the best model combined volumetric BMD and a moment of inertia (r(2) = 0.78, P < .001; r(2) = 0.85, P < .001). FEM explained 87% (P < .001) and 83% (P < .001) of bone strength, respectively. By combining (a) radiography and DXA and (b) quantitative CT and DXA, correlations with mechanical failure load increased to 0.82 (P < .001) and 0.84 (P < .001), respectively, for radiography and DXA and to 0.80 (P < .001) and 0.86 (P < .001) , respectively, for quantitative CT and DXA. Conclusion Quantitative CT-based FEM was the best method with which to predict the experimental failure load; however, combining quantitative CT and DXA yielded a performance as good as that attained with FEM. The quantitative CT DXA combination may be easier to use in fracture prediction, provided standardized software is developed. These findings also highlight the major influence on femoral failure load, particularly in the trochanteric region, of a densitometric parameter combined with a geometric parameter. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Quadril/diagnóstico por imagem , Absorciometria de Fóton , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Cadáver , Feminino , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estresse Mecânico , Tomografia Computadorizada por Raios X/métodos
15.
J Mech Behav Biomed Mater ; 48: 210-219, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25955563

RESUMO

The objective of this study was to investigate the sensitivity of the nonlinear elastic properties of cortical bone to the presence of a single submillimetric crack. Nonlinear elasticity was measured by nonlinear resonant ultrasound spectroscopy (NRUS) in 14 human cortical bone specimens. The specimens were parallelepiped beams (50×2×2 mm(3)). A central notch of 500 µm was made to control crack initiation and propagation during four-point bending. The nonlinear hysteretic elastic and dissipative parameters αf and αQ, and Young׳s modulus Eus were measured in dry condition for undamaged (control) specimens and in dry and wet conditions for damaged specimens. The length of the crack was assessed using synchrotron radiation micro-computed tomography (SR-µCT) with a voxel size of 1.4 µm. The initial values of αf, measured on the intact specimens, were remarkably similar for all the specimens (αf =-5.5±1.5). After crack propagation, the nonlinear elastic coefficient αf increased significantly (p<0.006), with values ranging from -4.0 to -296.7. Conversely, no significant variation was observed for αQ and Eus. A more pronounced nonlinear elastic behavior was observed in hydrated specimens compared to dry specimens (p<0.001) after propagation of a single submillimetric crack. The nonlinear elastic parameter αf was found to be significantly correlated to the crack length both in dry (R=0.79, p<0.01) and wet (R=0.84, p<0.005) conditions. Altogether these results show that nonlinear elasticity assessed by NRUS is sensitive to a single submillimetric crack induced mechanically and suggest that the humidity must be strictly controlled during measurements.


Assuntos
Osso e Ossos/fisiologia , Elasticidade , Modelos Biológicos , Idoso , Idoso de 80 Anos ou mais , Humanos , Estresse Mecânico
16.
Proc Inst Mech Eng H ; 228(10): 1059-68, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25324291

RESUMO

In models developed for impact biomechanics, muscles are usually represented with one-dimensional elements having active and passive properties. The passive properties of muscles are most often obtained from experiments performed on animal muscles, because limited data on human muscle are available. The aim of this study is thus to characterize the passive response of a human muscle in tension. Tensile tests at different strain rates (0.0045, 0.045, and 0.45 s⁻¹) were performed on 10 extensor carpi ulnaris muscles. A model composed of a nonlinear element defined with an exponential law in parallel with one or two Maxwell elements and considering basic geometrical features was proposed. The experimental results were used to identify the parameters of the model. The results for the first- and second-order model were similar. For the first-order model, the mean parameters of the exponential law are as follows: Young's modulus E (6.8 MPa) and curvature parameter α (31.6). The Maxwell element mean values are as follows: viscosity parameter η (1.2 MPa s) and relaxation time τ (0.25 s). Our results provide new data on a human muscle tested in vitro and a simple model with basic geometrical features that represent its behavior in tension under three different strain rates. This approach could be used to assess the behavior of other human muscles.


Assuntos
Modelos Biológicos , Músculo Esquelético/fisiopatologia , Estimulação Física/métodos , Rigor Mortis/fisiopatologia , Idoso , Cadáver , Simulação por Computador , Humanos , Masculino , Movimento (Física) , Estresse Mecânico , Resistência à Tração , Viscosidade
17.
J Biomech ; 47(6): 1548-53, 2014 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-24581799

RESUMO

Advanced finite element models of the thorax have been developed to study, for example, the effects of car crashes. While there is a need for material properties to parameterize such models, specific properties are largely missing. Non-destructive techniques applicable in vivo would, therefore, be of interest to support further development of thorax models. The only non-destructive technique available today to derive rib bone properties would be based on quantitative computed tomography that measures bone mineral density. However, this approach is limited by the radiation dose. Bidirectional ultrasound axial transmission was developed on long bones ex vivo and used to assess in vivo health status of the radius. However, it is currently unknown if the ribs are good candidates for such a measurement. Therefore, the goal of this study is to evaluate the relationship between ex vivo ultrasonic measurements (axial transmission) and the mechanical properties of human ribs to determine if the mechanical properties of the ribs can be quantified non-destructively. The results show statistically significant relationships between the ultrasonic measurements and mechanical properties of the ribs. These results are promising with respect to a non-destructive and non-ionizing assessment of rib mechanical properties. This ex vivo study is a first step toward in vivo studies to derive subject-specific rib properties.


Assuntos
Costelas/diagnóstico por imagem , Costelas/fisiologia , Acidentes de Trânsito , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Densidade Óssea , Força Compressiva , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Rádio (Anatomia)/diagnóstico por imagem , Tórax , Tomografia Computadorizada por Raios X , Ultrassonografia
18.
PLoS One ; 9(1): e83599, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24392089

RESUMO

The objective of the study was to evaluate the ability of a nonlinear ultrasound technique, the so-called nonlinear resonant ultrasound spectroscopy (NRUS) technique, for detecting early microdamage accumulation in cortical bone induced by four-point bending fatigue. Small parallelepiped beam-shaped human cortical bone specimens were subjected to cyclic four-point bending fatigue in several steps. The specimens were prepared to control damage localization during four-point bending fatigue cycling and to unambiguously identify resonant modes for NRUS measurements. NRUS measurements were achieved to follow the evolution of the nonlinear hysteretic elastic behavior during fatigue-induced damage. After each fatigue step, a small number of specimens was removed from the protocol and set apart to quantitatively assess the microcrack number density and length using synchrotron radiation micro-computed tomography (SR-µCT). The results showed a significant effect of damage steps on the nonlinear hysteretic elastic behavior. No significant change in the overall length of microcracks was observed in damaged regions compared to the load-free control regions. Only an increased number of shortest microcracks, those in the lowest quartile, was noticed. This was suggestive of newly formed microcracks during the early phases of damage accumulation. The variation of nonlinear hysteretic elastic behavior was significantly correlated to the variation of the density of short microcracks. Our results suggest that the nonlinear hysteretic elastic behavior is sensitive to early bone microdamage. Therefore NRUS technique can be used to monitor fatigue microdamage progression in in vitro experiments.


Assuntos
Osso e Ossos/diagnóstico por imagem , Osso e Ossos/patologia , Análise Espectral/métodos , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Matriz Óssea/diagnóstico por imagem , Matriz Óssea/patologia , Feminino , Fraturas de Estresse/diagnóstico por imagem , Fraturas de Estresse/patologia , Humanos , Análise Espectral/instrumentação , Estresse Mecânico , Tomografia Computadorizada por Raios X , Ultrassonografia
19.
Proc Inst Mech Eng H ; 228(1): 27-36, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24280228

RESUMO

The load-deflection response of the human trunk has been studied using various methods. The different shapes observed may be due to the methodology and the population. The purpose of this study is to quantify and explain the in vivo mechanical response of paediatric and adult trunks during respiratory physiotherapy. Eight children aged 5-15 months and eight healthy adult volunteers aged 30-87 years participated in this study. The force applied by the physiotherapist and the displacement of the targets on his hands were recorded. Parameters were also measured and calculated to compare against other studies. Time lags between force time histories and displacement time histories were observed on both children and adults. Different time lags resulted in different shapes of the force-displacement curves. Factors including respiration, muscle contraction and loading pattern are part of the assumptions used to explain this phenomenon. The maximum displacements of the paediatric and adult trunks were 18 and 44 mm, respectively, with a maximum load of 208 and 250 N, respectively. This study provides a better explanation of the peculiar force-displacement characteristics of both living and active children and adults under a non-injurious, low-rate compression condition. Complementary data (e.g. muscle activity and breathing) should be collected in the future to go towards in vivo human trunk modelling.


Assuntos
Fenômenos Biomecânicos/fisiologia , Terapia Respiratória , Tórax/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Bronquiolite/terapia , Feminino , Marcadores Fiduciais , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas , Estresse Mecânico , Tronco/fisiologia , Gravação em Vídeo
20.
J Mech Behav Biomed Mater ; 27: 77-83, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23871332

RESUMO

Improving the numerical models of the head and neck complex requires understanding the mechanical properties of the muscles; however, most of the data in existing literature have been obtained from studies on animal muscles. Muscle is hyper-elastic, but also viscoelastic. The hyper-elastic behaviour of the human sternocleidomastoideus muscle has been previously studied. The aim of this study is to propose a characterization of the viscoelastic properties of the same human muscle in relaxation. Ten muscles were tested in vitro. The viscoelastic behaviour was modelled with a generalized Maxwell's model studied at the first and second order, using an inverse approach with a subject-specific, finite-element model of each muscle. Based on these models, relaxation times τ (first order: 103s; second order: 18s and 395s) and ratio moduli γ (first order: 0.33; second order: 0.20 and 0.19) were identified. The first-order model provided a good estimate of the relaxation curve (R(2): 0.82), but the second-order model was more representative of the experimental response (R(2): 0.97). Our results provide evidence that the viscoelastic behaviour of the human sternocleidomastoideus muscle can be described using a second-order Maxwell's model and that - combined with the previously identified hyper-elastic properties - the response of the muscle in tension and relaxation is fully characterized.


Assuntos
Envelhecimento/fisiologia , Elasticidade , Relaxamento Muscular , Músculos do Pescoço/fisiologia , Idoso , Feminino , Análise de Elementos Finitos , Humanos , Pessoa de Meia-Idade , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA