Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
1.
Surg Today ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844737

RESUMO

PURPOSE: New approaches to endoscopic thyroid surgery have been developed to improve cosmetic results, one of which is video-assisted neck surgery (VANS). The present study investigates the safety and effectiveness of thyroidectomy by VANS as oncologic surgery for papillary thyroid carcinoma (PTC). METHODS: The subjects of this retrospective study were 121 patients with PTC, who underwent hemi-thyroid lobectomy and central lymph node dissection via open surgery (n = 102) or VANS (n = 19) at Tokushima University Hospital between 2011 and 2023. We performed 1:1 propensity score matching and then compared the surgical outcomes between the two matched groups. RESULTS: Propensity score matching generated 18 distinct examination pairs. The VANS group had significantly less blood loss (P = 0.003), but a longer operative time (P < 0.001) than the open thyroidectomy group. There were two cases of transient recurrent laryngeal nerve paralysis and one case of recurrence in the lateral regional lymph nodes in the VANS group. However, no significant differences were observed in the incidence of complications (P = 0.243) or recurrence (P = 0.500) between the two groups. CONCLUSION: VANS is a safe and effective surgical procedure for PTC, but longer follow-up is needed to assess tumor recurrence.

2.
Gland Surg ; 13(4): 578-583, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38720672

RESUMO

Background: Although thyroid tumors with tracheal stenosis are occasionally encountered, severe tracheal stenosis caused by benign thyroid tumors is rare. We herein describe a case in which a silicone tracheal stent was placed for severe tracheal stenosis induced by a giant goiter due to Graves' disease. Case Description: A 93-year-old woman had been receiving thiamazole treatment for Graves' disease with a thyroid goiter for 32 years. She emergently presented to the hospital with sudden difficulty breathing and the temporary loss of consciousness. Although marked stridor was heard, the patient's respiratory status was stable in the first visit. Computed tomography revealed a giant thyroid goiter that extended to the mediastinum. The trachea was compressed by the sternal notch and thyroid gland, resulting in severe stenosis, and the tracheal lumen was only 1 mm. Surgical thyroidectomy was expected to be difficult due to the high risk of complications associated with the large size of the goiter and advanced age of the patient. Therefore, we decided to place a tracheal stent. A silicone stent (Dumon tube®) was inserted into the site of tracheal stenosis under general anesthesia. After stent placement, respiratory distress symptoms improved, and no complications were observed. Three months after stent placement, the stent opening side was narrowed due to defective granulation and, thus, was cauterized with argon plasma coagulation. Conclusions: We encountered a patient who was treated by tracheal silicone stent placement for severe tracheal stenosis induced by a giant goiter due to Graves' disease. A silicone stent effectively secures the airway for benign thyroid tumors that cause severe airway stenosis.

3.
J Cardiothorac Surg ; 19(1): 291, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38755707

RESUMO

BACKGROUND: Immunoglobulin (Ig)G4-related disease affects nearly every organ, and its clinical course varies depending on the involved organ; however, its occurrence in the mediastinum is rarely reported. CASE PRESENTATION: A 58-year-old woman presented with a posterior mediastinal tumor along the thoracic spine on imaging. Based on her elevated serum IgG4 level of 349.7 mg/dL, IgG4-related disease was suspected. Since the tumor was growing and malignancy could not be excluded, surgical resection was performed for definitive diagnosis. Robot-assisted thoracoscopic surgery was performed via the left semipronation and right thoracic approaches. The irregularly-shaped tumor was located on the level of the seventh to ninth thoracic vertebra, along the sympathetic nerve. A malignancy was not excluded based on the appearance of the tumor. The tumor had poor mobility. The sympathetic nerves, intercostal arteries, and veins were also excised. In this case, the articulated forceps, used during the robotic surgery, were useful in achieving complete tumor resection along the vertebral body. The pathological examination revealed IgG4-positive plasma infiltration, which fulfilled the criteria for IgG4-related diseases. The postoperative course was uneventful, and the patient underwent follow-up on an outpatient basis without additional medications. CONCLUSION: The clinical presentation of IgG4-related disease varies, based on the involved organs. This case was rare because the mediastinum was involved, and it emphasized the effectiveness of surgical resection.


Assuntos
Doença Relacionada a Imunoglobulina G4 , Neoplasias do Mediastino , Procedimentos Cirúrgicos Robóticos , Humanos , Feminino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Robóticos/métodos , Neoplasias do Mediastino/cirurgia , Neoplasias do Mediastino/diagnóstico , Doença Relacionada a Imunoglobulina G4/cirurgia , Doença Relacionada a Imunoglobulina G4/diagnóstico , Toracoscopia/métodos , Tomografia Computadorizada por Raios X
4.
Beilstein J Org Chem ; 20: 1020-1028, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38711591

RESUMO

Diaryliodonium(III) salts are versatile reagents that exhibit a range of reactions, both in the presence and absence of metal catalysts. In this study, we developed efficient synthetic methods for the preparation of aryl(TMP)iodonium(III) carboxylates, by reaction of (diacetoxyiodo)arenes or iodosoarenes with 1,3,5-trimethoxybenzene in the presence of a diverse range of organocarboxylic acids. These reactions were conducted under mild conditions using the trimethoxyphenyl (TMP) group as an auxiliary, without the need for additives, excess reagents, or counterion exchange in further steps. These protocols are compatible with a wide range of substituents on (hetero)aryl iodine(III) compounds, including electron-rich, electron-poor, sterically congested, and acid-labile groups, as well as a broad range of aliphatic and aromatic carboxylic acids for the synthesis of diverse aryl(TMP)iodonium(III) carboxylates in high yields. This method allows for the hybridization of complex bioactive and fluorescent-labeled carboxylic acids with diaryliodonium(III) salts.

5.
Radiat Oncol J ; 42(1): 74-82, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38549386

RESUMO

PURPOSE: To investigate the clinical significance of adaptive radiotherapy (ART) in locally advanced nasopharyngeal carcinoma treated with intensity-modulated radiotherapy (IMRT). MATERIALS AND METHODS: Eligible patients were treated with concurrent chemoradiotherapy using IMRT. Planning computed tomography in ART was performed during radiotherapy, and replanning was performed. Since ART was started in May 2011 (ART group), patients who were treated without ART up to April 2011 (non-ART group) were used as the historical control. The Kaplan-Meier method was used to calculate overall survival (OS), locoregional recurrence-free survival (LRFS), progression-free survival (PFS), and distant metastasis-free survival (DMFS). LRFS for the primary tumor (LRFS_P) and regional lymph node (LRFS_LN) were also studied for more detailed analysis. Statistical significance was evaluated using the log-rank test for survival. RESULTS: The ART group tended to have higher radiation doses. The median follow-up period was 127 months (range, 10 to 211 months) in the non-ART group and 61.5 months (range, 5 to 129 months) in the ART group. Compared to the non-ART group, the ART group showed significantly higher 5-year PFS (53.8% vs. 81.3%, p = 0.015) and LRFS (61.2% vs. 85.3%, p = 0.024), but not OS (80.7% vs. 80.8%, p = 0.941) and DMFS (84.6% vs. 92.7%, p = 0.255). Five-year LRFS_P was higher in the ART group (61.3% vs. 90.6%, p = 0.005), but LRFS_LN did not show a significant difference (91.9% vs. 96.2%, p = 0.541). CONCLUSION: Although there were differences in the patient backgrounds between the two groups, this study suggests the potential effectiveness of ART in improving locoregional control, especially in the primary tumor.

6.
ACS Omega ; 9(6): 6873-6879, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38371756

RESUMO

In this study, we devised a novel method to create heterologous producers of lethal antibiotics against host bacteria. Heterologous producers cannot be created when antibiotics are toxic to host bacteria. To overcome this challenge, we developed a novel method involving construction of a combinatorial library with various promoters and screening based on the production. To realize this, we utilized Combi-OGAB (Combinatorial Ordered Gene Assembly in Bacillus subtilis), which technology can effectively construct diverse combinatorial library and accelerate screening procedures. B. subtilis and Gramicidin S were selected as the host bacterium and the targeted antibiotic, respectively. The screened producer from Combi-OGAB screening cycles achieved >30-fold productivity over the lethal level. These results suggest that our strategy has the potential to maximize the phenotypic resistance of host bacteria to create heterologous lethal antibiotic producers.

7.
J Radiat Res ; 65(1): 92-99, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-37996094

RESUMO

The SyncTraX series enables real-time tumor-tracking radiotherapy through the real-time recognition of a fiducial marker using fluoroscopic images. In this system, the isocenter should be located within approximately 5-7.5 cm from the marker, depending on the version, owing to the limited field of view. If the marker is placed away from the tumor, the isocenter should be shifted toward the marker. This study aimed to investigate stereotactic body radiotherapy (SBRT) outcomes of primary liver tumors treated with SyncTraX in cases where the isocenter was shifted marginally or outside the planning target volume (PTV). Twelve patients with 13 liver tumors were included in the analysis. Their isocenter was shifted toward the marker and was placed marginally or outside the PTV. The prescribed doses were generally 40 Gy in four fractions or 48 Gy in eight fractions. The overall survival (OS) and local control (LC) rates were calculated using the Kaplan-Meier method. All patients completed the scheduled SBRT. The median distance between the fiducial marker and PTV centroid was 56.0 (interquartile range [IQR]: 52.7-66.7) mm. By shifting the isocenter toward the marker, the median distance between the marker and isocenter decreased to 34.0 (IQR: 33.4-39.7) mm. With a median follow-up period of 25.3 (range: 6.9-70.0) months, the 2-year OS and LC rates were 100.0% (95% confidence interval: 100-100). An isocenter shift makes SBRT with SyncTraX feasible in cases where the fiducial marker is distant from the tumor.


Assuntos
Neoplasias Hepáticas , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Estudos Retrospectivos , Neoplasias Hepáticas/radioterapia , Radiocirurgia/métodos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
8.
J Appl Clin Med Phys ; 25(4): e14250, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38146130

RESUMO

BACKGROUND: Organ-at-risk (OAR) sparing is often assessed using an overlap volume-based parameter, defined as the ratio of the volume of OAR that overlaps the planning target volume (PTV) to the whole OAR volume. However, this conventional overlap-based predictive parameter (COPP) does not consider the volume relationship between the PTV and OAR. PURPOSE: We propose a new overlap-based predictive parameter that consider the PTV volume. The effectiveness of proposed overlap-based predictive parameter (POPP) is evaluated compared with COPP. METHODS: We defined as POPP = (overlap volume between OAR and PTV/OAR volume) × (PTV volume/OAR volume). We generated intensity modulated radiation therapy (IMRT) based on step and shoot technique, and volumetric modulated arc therapy (VMAT) plans with the Auto-Planning module of Pinnacle3 treatment planning system (v14.0, Philips Medical Systems, Fitchburg, WI) using the American Association of Physicists in Medicine Task Group (TG119) prostate phantom. The relationship between the position and size of the prostate phantom was systematically modified to simulate various geometric arrangements. The correlation between overlap-based predictive parameters (COPP and POPP) and dose-volume metrics (mean dose, V70Gy, V60Gy, and V37.5 Gy for rectum and bladder) was investigated using linear regression analysis. RESULTS: Our results indicated POPP was better than COPP in predicting intermediate-dose metrics. The bladder results showed a trend similar to that of the rectum. The correlation coefficient of POPP was significantly greater than that of COPP in < 62 Gy (82% of the prescribed dose) region for IMRT and in < 55 Gy (73% of the prescribed dose) region for VMAT regarding the rectum (p < 0.05). CONCLUSIONS: POPP is superior to COPP for creating predictive models at an intermediate-dose level. Because rectal bleeding and bladder toxicity can be associated with intermediate-doses as well as high-doses, it is important to predict dose-volume metrics for various dose levels. POPP is a useful parameter for predicting dose-volume metrics and assisting the generation of treatment plans.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco , Neoplasias da Próstata/radioterapia
9.
Med Phys ; 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38127935

RESUMO

BACKGROUND: Ionoacoustics is a promising approach to reduce the range uncertainty in proton therapy. A miniature-sized optical hydrophone (OH) was used as a measuring device to detect weak ionoacoustic signals with a high signal-to-noise ratio in water. However, further development is necessary to prevent wave distortion because of nearby acoustic impedance discontinuities while detection is conducted on the patient's skin. PURPOSE: A prototype of the probe head attached to an OH was fabricated and the required dimensions were experimentally investigated using a 100-MeV proton beam from a fixed-field alternating gradient accelerator and k-Wave simulations. The beam range of the proton in a tissue-mimicking phantom was estimated by measuring γ-waves and spherical ionoacoustic waves with resonant frequency (SPIRE). METHODS: Four sizes of probe heads were fabricated from agar blocks for the OH. Using the prototype, the Î³-wave was detected at distal and lateral positions to the Bragg peak on the phantom surface for proton beams delivered at seven positions. For SPIRE, independent measurements were performed at distal on- and off-axis positions. The range positions were estimated by solving the linear equation using the sensitive matrix for the γ-wave and linear fitting of the correlation curve for SPIRE; they were compared with those measured using a film. RESULTS: The first peak of the γ-wave was undistorted with the 3 × 3 × 3-cm3 probe head used at the on-axis and 3-cm off-axis positions. The range positions estimated by the γ-wave agreed with the film-based range in the depth direction (the maximum deviation was 0.7 mm), although a 0.6-2.1 mm deviation was observed in the lateral direction. For SPIRE, the deviation was <1 mm for the two measurement positions. CONCLUSIONS: The attachment of a relatively small-sized probe head allowed the OH to measure the beam range on the phantom surface.

10.
BJR Open ; 5(1): 20230043, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37942491

RESUMO

Objectives: We aimed to investigate whether daily computed tomography (CT) images could predict the daily gastroduodenal, small intestine, and large intestine doses of stereotactic body radiation therapy (SBRT) for pancreatic cancer based on the shortest distance between the gross tumor volume (GTV) and gastrointestinal (GI) tract. Methods: Twelve patients with pancreatic cancer received SBRT of 40 Gy in five fractions. We recalculated the reference clinical SBRT plan (PLANref) using daily CT images and calculated the shortest distance from the GTV to each GI tract. The maximum dose delivered to 0.5 cc (D0.5cc) was evaluated for each planning at-risk volume of the GI tract. Spearman's correlation test was used to determine the association between the daily change in the shortest distance (Δshortest distance) and the ratio of ΔD0.5cc dose to D0.5cc dose in PLANref (ΔD0.5cc/PLANref) for quantitative analysis. Results: The median shortest distance in PLANref was 0 mm in the gastroduodenum (interquartile range, 0-2.7), 16.7 mm in the small intestine (10.0-23.7), and 16.7 mm in the large intestine (8.3-28.1 mm). The D0.5cc of PLANref in the gastroduodenum was >30 Gy in all patients, with 10 (83.3%) having the highest dose. A significant association was found between the Δshortest distance and ΔD0.5cc/ PLANref in the small or large intestine (p < 0.001) but not in the gastroduodenum (p = 0.404). Conclusions: The gastroduodenum had a higher D0.5cc and predicting the daily dose was difficult. Daily dose calculations of the GI tract are recommended for safe SBRT. Advances in knowledge: This study aimed to predict the daily doses in SBRT for pancreatic cancer from the shortest distance between the GTV and the gastrointestinal tract.Daily changes in the shortest distance can predict the daily dose to the small or large intestines, but not to the gastroduodenum.

11.
Appl Opt ; 62(29): 7549-7559, 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37855461

RESUMO

Although a lateral-shear interferometer is robust against optical component vibrations, its interferogram provides information about differential wavefronts rather than the wavefronts themselves, resulting in the loss of specific frequency components. Previous studies have addressed this limitation by measuring four interferograms with different shear amounts to accurately restore the two-dimensional wavefront. This study proposes a technique that employs spectral interpolation to reduce the number of required interferograms. The proposed approach introduces an origin-shift technique for accurate spectral interpolation, which in turn is implemented by combining two methods: natural extension and least-squares determination of ambiguities in uniform biases. Numerical simulations confirmed that the proposed method accurately restored a two-dimensional wavefront from just two interferograms, thereby indicating its potential to address the limitations of the lateral-shear interferometer.

12.
J Thorac Dis ; 15(2): 579-588, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36910050

RESUMO

Background: Multimodal transbronchial biopsy (TBB) may have improved diagnostic yield for peripheral pulmonary lesions suspected as lung cancer. Radial endobronchial ultrasound (R-EBUS) provides real-time imaging and confirmation of the location of the lesions. Cone-beam computed tomography (CBCT) can confirm that the forceps tip has reached the lesion before biopsy. Methods: Patients with peripheral pulmonary lesions and a positive computed tomography (CT) bronchus sign (based on slice thickness of 1 mm) were prospectively enrolled. An ultrathin bronchoscope (UTB) and R-EBUS probe were advanced to the target bronchus. Thereafter, forceps were advanced, and CBCT was performed. R-EBUS was performed for re-navigation, if possible. The obtained EBUS and CBCT images were classified into "within" (type 1), "adjacent to" (type 2), or "far from" (type 3), based on the probe or forceps tip. Results: For 20 lesions, the diagnostic yield was 85%. The primary EBUS images were of types 1, 2, and 3 in 12, 6, and 2 cases, respectively. The primary CBCT images were of types 1, 2, and 3 in 12, 6, and 2 cases, respectively. Primary EBUS and CBCT image types were equivalent in 14 cases. Of the 12 cases with type 1 primary EBUS image, 9 cases had a type 1 primary CBCT image, while 3 cases exhibited positional misalignment of the forceps tip. Re-navigation was required in 8 cases with types 2 and 3 primary CBCT images. Conclusions: CBCT-guided TBB using an UTB and EBUS may enable real-time positioning guidance and better re-navigation in the diagnosis of peripheral pulmonary lesions.

13.
Br J Radiol ; 96(1144): 20220720, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36633335

RESUMO

OBJECTIVES: In a previous study of hepatic toxicity, the following three factors were identified to predict the benefits of proton beam therapy (PBT) for hepatocellular carcinomas (HCCs) with a maximum diameter of ≤5 cm and Child-pugh grade A (CP-A): number of tumors (1 vs ≥2), the location of tumors (hepatic hilum or others), and the sum of the diameters of lesions. The aim of this study is to analyze the association between these three factors and hepatic toxicity. METHODS: We retrospectively reviewed patients of CP-A treated with PBT or photon stereotactic body radiotherapy (X-ray radiotherapy, XRT) for HCC ≤5 cm. For normal liver dose, the V5, V10, V20 (volumes receiving 5, 10, and 20 Gy at least), and the mean dose was evaluated. The albumin-bilirubin (ALBI) and CP score changes from the baseline were evaluated at 3 and 6 months after treatment. RESULTS: In 89 patients (XRT: 48, PBT: 41), those with two or three (2-3) predictive factors were higher normal liver doses than with zero or one (0-1) factor. In the PBT group, the ALBI score worsened more in patients with 2-3 factors than those with 0-1 factor, at 3 months (median: 0.26 vs 0.02, p = 0.032) and at 6 months (median: 0.35 vs 0.10, p = 0.009). The ALBI score change in the XRT group and CP score change in either modality were not significantly different in the number of predictive factors. CONCLUSION: The predictive factor numbers predicted the ALBI score change in PBT but not in XRT. ADVANCES IN KNOWLEDGE: This study suggest that the number of predictive factors previously identified (0-1 vs 2-3) were significantly associated with dosimetric parameters of the normal liver in both modalities. In the proton group, the number of predictive factors was associated with a worsening ALBI score at 3 and 6 months, but these associations were not found in the photon SBRT group.


Assuntos
Carcinoma Hepatocelular , Doenças do Sistema Digestório , Hepatite , Neoplasias Hepáticas , Terapia com Prótons , Humanos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/patologia , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/patologia , Terapia com Prótons/efeitos adversos , Prótons , Estudos Retrospectivos , Bilirrubina
14.
Clin Breast Cancer ; 23(3): e68-e76, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36682907

RESUMO

NTRODUCTION/BACKGROUND: Some reports have shown that absolute lymphocyte count (ALC) is associated with prognosis in breast cancer; however, the impact of ALC changes remains unclear. This study aimed to investigate the relationship between ALC changes during neoadjuvant chemotherapy for human epidermal growth factor receptor-2 (HER2)-positive breast cancer patients and disease prognosis. PATIENTS AND METHODS: This retrospective cohort study January 2010 to September 2020) included patients diagnosed with HER2-positive breast cancer and treated with trastuzumab-based neoadjuvant chemotherapy. The ALC ratio was defined as the ALC value after administration of the anti-HER2 drug divided by the ALC value before administration. The optimal ALC ratio cut-off value was identified using the receiver operating characteristic curve analysis and Youden's index. The relationship between the ALC ratio and disease-free survival was assessed using the Kaplan-Meier method. Univariate and multivariate analyses were performed using the Cox proportional hazards model. RESULTS: Data from a total of 100 HER2-positive breast cancer patients were analyzed. The cut-off value of the ALC ratio was set as 1.142. The median follow-up period was 52.0 (range: 5.1-123.7) months. The 5-year disease-free survival rates were 88.4% and 60.9% in the high-and low-ALC ratio groups, respectively, and were significantly higher in the high-ALC ratio group (p = .0031). The ALC ratio was an independent prognostic factor in multivariate Cox proportional hazards analysis (p = .0032). CONCLUSION: HER2-positive breast cancer patients with a higher ALC ratio during trastuzumab-based neoadjuvant chemotherapy may have a better prognosis than their counterparts.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Terapia Neoadjuvante/métodos , Estudos Retrospectivos , Receptor ErbB-2/metabolismo , Prognóstico , Trastuzumab/uso terapêutico , Intervalo Livre de Doença , Contagem de Linfócitos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico
15.
Clin Transl Radiat Oncol ; 39: 100576, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36686564

RESUMO

Background: The aim of this study is to quantify the short-term motion of the gastrointestinal tract (GI-tract) and its impact on dosimetric parameters in stereotactic body radiation therapy (SBRT) for pancreatic cancer. Methods: The analyzed patients were eleven pancreatic cancer patients treated with SBRT or proton beam therapy. To ensure a fair analysis, the simulation SBRT plan was generated on the planning CT in all patients with the dose prescription of 40 Gy in 5 fractions. The GI-tract motion (stomach, duodenum, small and large intestine) was evaluated using three CT images scanned at spontaneous expiration. After fiducial-based rigid image registration, the contours in each CT image were generated and transferred to the planning CT, then the organ motion was evaluated. Planning at risk volumes (PRV) of each GI-tract were generated by adding 5 mm margins, and the volume receiving at least 33 Gy (V33) < 0.5 cm3 was evaluated as the dose constraint. Results: The median interval between the first and last CT scans was 736 s (interquartile range, IQR:624-986). To compensate for the GI-tract motion based on the planning CT, the necessary median margin was 8.0 mm (IQR: 8.0-10.0) for the duodenum and 14.0 mm (12.0-16.0) for the small intestine. Compared to the planned V33 with the worst case, the median V33 in the PRV of the duodenum significantly increased from 0.20 cm3 (IQR: 0.02-0.26) to 0.33 cm3 (0.10-0.59) at Wilcoxon signed-rank test (p = 0.031). Conclusion: The short-term motions of the GI-tract lead to high dose differences.

16.
Med Phys ; 50(2): 675-687, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36502527

RESUMO

BACKGROUND: Online adaptation during intensity-modulated proton therapy (IMPT) can minimize the effect of inter-fractional anatomical changes, but remains challenging because of the complex workflow. One approach for fast and automated online IMPT adaptation is dose restoration, which restores the initial dose distribution on the updated anatomy. However, this method may fail in cases where tumor deformation or position changes occur. PURPOSE: To develop a fast and robust IMPT online adaptation method named "deformed dose restoration (DDR)" that can adjust for inter-fractional tumor deformation and position changes. METHODS: The DDR method comprises two steps: (1) calculation of the deformed dose distribution, and (2) restoration of the deformed dose distribution. First, the deformable image registration (DIR) between the initial clinical target volume (CTV) and the new CTV were performed to calculate the vector field. To ensure robustness for setup and range uncertainty and the ability to restore the deformed dose distribution, an expanded CTV-based registration to maintain the dose gradient outside the CTV was developed. The deformed dose distribution was obtained by applying the vector field to the initial dose distribution. Then, the voxel-by-voxel dose difference optimization was performed to calculate beam parameters that restore the deformed dose distribution on the updated anatomy. The optimization function was the sum of total dose differences and dose differences of each field to restore the initial dose overlap of each field. This method only requires target contouring, which eliminates the need for organs at risk (OARs) contouring. Six clinical cases wherein the tumor deformation and/or position changed on repeated CTs were selected. DDR feasibility was evaluated by comparing the results with those from three other strategies, namely, not adapted (continuing the initial plan), adapted by previous dose restoration, and fully optimized. RESULTS: In all cases, continuing the initial plan was largely distorted on the repeated CTs and the dose-volume histogram (DVH) metrics for the target were reduced due to the tumor deformation or position changes. On the other hand, DDR improved DVH metrics for the target to the same level as the initial dose distribution. Dose increase was seen for some OARs because tumor growth had reduced the relative distance between CTVs and OARs. Robustness evaluation for setup and range uncertainty (3 mm/3.5%) showed that deviation in DVH-bandwidth for CTV D95% from the initial plan was 0.4% ± 0.5% (Mean ± S.D.) for DDR. The calculation time was 8.1 ± 6.4 min. CONCLUSIONS: An online adaptation algorithm was developed that improved the treatment quality for inter-fractional anatomical changes and retained robustness for intra-fractional setup and range uncertainty. The main advantage of this method is that it only requires target contouring alone and saves the time for OARs contouring. The fast and robust adaptation method for tumor deformation and position changes described here can reduce the need for offline adaptation and improve treatment efficiency.


Assuntos
Neoplasias , Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco
17.
Med Phys ; 50(2): 993-999, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36427355

RESUMO

PURPOSE: To quantitatively evaluate the achievable performance of volumetric imaging based on lung motion modeling by principal component analysis (PCA). METHODS: In volumetric imaging based on PCA, internal deformation was represented as a linear combination of the eigenvectors derived by PCA of the deformation vector fields evaluated from patient-specific four-dimensional-computed tomography (4DCT) datasets. The volumetric image was synthesized by warping the reference CT image with a deformation vector field which was evaluated using optimal principal component coefficients (PCs). Larger PCs were hypothesized to reproduce deformations larger than those included in the original 4DCT dataset. To evaluate the reproducibility of PCA-reconstructed volumetric images synthesized to be close to the ground truth as possible, mean absolute error (MAE), structure similarity index measure (SSIM) and discrepancy of diaphragm position were evaluated using 22 4DCT datasets of nine patients. RESULTS: Mean MAE and SSIM values for the PCA-reconstructed volumetric images were approximately 80 HU and 0.88, respectively, regardless of the respiratory phase. In most test cases including the data of which motion range was exceeding that of the modeling data, the positional error of diaphragm was less than 5 mm. The results suggested that large deformations not included in the modeling 4DCT dataset could be reproduced. Furthermore, since the first PC correlated with the displacement of the diaphragm position, the first eigenvector became the dominant factor representing the respiration-associated deformations. However, other PCs did not necessarily change with the same trend as the first PC, and no correlation was observed between the coefficients. Hence, randomly allocating or sampling these PCs in expanded ranges may be applicable to reasonably generate an augmented dataset with various deformations. CONCLUSIONS: Reasonable accuracy of image synthesis comparable to those in the previous research were shown by using clinical data. These results indicate the potential of PCA-based volumetric imaging for clinical applications.


Assuntos
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Análise de Componente Principal , Reprodutibilidade dos Testes , Movimento (Física) , Diagnóstico por Imagem , Respiração , Tomografia Computadorizada Quadridimensional/métodos
18.
J Med Imaging Radiat Oncol ; 67(1): 98-110, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36373823

RESUMO

INTRODUCTION: Sequential boost intensity-modulated radiotherapy (SQB-IMRT) uses two different planning CTs (pCTs) and treatment plans. SQB-IMRT is a form of adaptive radiotherapy that allows for responses to changes in the shape of the tumour and organs at risk (OAR). On the other hand, dose accumulation with the two plans can be difficult to evaluate. The purpose of this study was to analyse patterns of loco-regional failure using deformable image registration (DIR) in hypopharyngeal cancer patients treated with SQB-IMRT. METHODS: Between 2013 and 2019, 102 patients with hypopharyngeal cancer were treated with definitive SQB-IMRT at our institution. Dose accumulation with the 1st and 2nd plans was performed, and the dose to the loco-regional recurrent tumour volume was calculated using the DIR workflow. Failure was classified as follows: (i) in-field (≥95% of the recurrent tumour volume received 95% of the prescribed dose); (ii) marginal (20-95%); or (iii) out-of-field (<20%). RESULTS: After a median follow-up period of 25 months, loco-regional failure occurred in 34 patients. Dose-volume histogram analysis showed that all loco-regional failures occurred in the field within 95% of the prescribed dose, with no marginal or out-of-field recurrences observed. CONCLUSION: The dosimetric analysis using DIR showed that all loco-regional failures were within the high-dose region. More aggressive treatment may be required for gross tumours.


Assuntos
Neoplasias de Cabeça e Pescoço , Neoplasias Hipofaríngeas , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Recidiva Local de Neoplasia/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica
19.
Transl Cancer Res ; 11(11): 4200-4205, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36523308

RESUMO

Background: The abscopal effect is a systemic antitumor response that occurs distant to the irradiation site and is induced by local irradiation. We herein describe a case of solitary extramedullary plasmacytoma (SEP) of the thyroid in which bone metastases disappeared after thyroidectomy and cervical radiotherapy (RT). Case Description: A 68-year-old man with a right cervical swelling for approximately 10 years visited a hospital with left elbow pain that persisted for 5 months. He was referred to our hospital for more detailed examinations and treatment. An immobile mass of approximately 10 cm in diameter was palpable on the right side of the patient's neck. Computed tomography (CT) showed osteolytic changes in the left humerus and right scapula, and a tumor in the right lobe of the thyroid gland. The patient was diagnosed with widely invasive follicular carcinoma and multiple bone metastases and underwent total thyroidectomy. During surgery, tumor infiltration into the trachea was observed. Shaving between the tumor and trachea was performed. Based on the results of a pathological examination, the patient was diagnosed with primary extramedullary plasmacytoma of the thyroid. After surgery, external beam RT was performed on the neck, which also reduced the pain in the left elbow. Positron emission tomography (PET)-CT showed the decreased accumulation of fluorodeoxyglucose (FDG) in the left humerus and right scapula, and the amelioration of osteolytic changes on CT. Conclusions: SEP of the thyroid is rare, and to the best of our knowledge, this is the first case report in which the abscopal effect was observed after thyroidectomy and cervical RT.

20.
Nat Commun ; 13(1): 5974, 2022 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-36216803

RESUMO

Macrophages play crucial roles in protecting our bodies from infection and cancers. As macrophages are multi-functional immune cells, they have diverse plastic subsets, such as M1 and M2, derived from naïve M0 cells. Subset-specific macrophage probes are essential for deciphering and monitoring the various activation of macrophages, but developing such probes has been challenging. Here we report a fluorescent probe, CDr17, which is selective for M1 macrophages over M2 or M0. The selective staining mechanism of CDr17 is explicated as Gating-Oriented Live-cell Distinction (GOLD) through overexpressed GLUT1 in M1 macrophages. Finally, we demonstrate the suitability of CDr17 to track M1 macrophages in vivo in a rheumatoid arthritis animal model.


Assuntos
Corantes Fluorescentes , Macrófagos , Animais , Transportador de Glucose Tipo 1/genética , Inflamação , Ativação de Macrófagos , Plásticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA