Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Echo Res Pract ; 11(1): 14, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38825684

RESUMO

BACKGROUND: Echocardiography is widely used to evaluate left ventricular (LV) diastolic function in patients suspected of heart failure. For patients in sinus rhythm, a combination of several echocardiographic parameters can differentiate between normal and elevated LV filling pressure with good accuracy. However, there is no established echocardiographic approach for the evaluation of LV filling pressure in patients with atrial fibrillation. The objective of the present study was to determine if a combination of several echocardiographic and clinical parameters may be used to evaluate LV filling pressure in patients with atrial fibrillation. RESULTS: In a multicentre study of 148 atrial fibrillation patients, several echocardiographic parameters were tested against invasively measured LV filling pressure as the reference method. No single parameter had sufficiently strong association with LV filling pressure to be recommended for clinical use. Based on univariate regression analysis in the present study, and evidence from existing literature, we developed a two-step algorithm for differentiation between normal and elevated LV filling pressure, defining values ≥ 15 mmHg as elevated. The parameters in the first step included the ratio between mitral early flow velocity and septal mitral annular velocity (septal E/e'), mitral E velocity, deceleration time of E, and peak tricuspid regurgitation velocity. Patients who could not be classified in the first step were tested in a second step by applying supplementary parameters, which included left atrial reservoir strain, pulmonary venous systolic/diastolic velocity ratio, and body mass index. This two-step algorithm classified patients as having either normal or elevated LV filling pressure with 75% accuracy and with 85% feasibility. Accuracy in EF ≥ 50% and EF < 50% was similar (75% and 76%). CONCLUSIONS: In patients with atrial fibrillation, no single echocardiographic parameter was sufficiently reliable to be used clinically to identify elevated LV filling pressure. An algorithm that combined several echocardiographic parameters and body mass index, however, was able to classify patients as having normal or elevated LV filling pressure with moderate accuracy and high feasibility.

2.
JACC Cardiovasc Imaging ; 15(12): 2038-2047, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36481071

RESUMO

BACKGROUND: Preprocedural right ventricular-to-pulmonary artery (RV-PA) coupling is a major predictor of outcome in patients with secondary mitral regurgitation (SMR) undergoing transcatheter edge-to-edge mitral valve repair (M-TEER). However, clinical significance of changes in RV-PA coupling after M-TEER is unknown. OBJECTIVES: The aim of this study was to evaluate changes in RV-PA coupling after M-TEER, their prognostic value, and predictors of improvement. METHODS: This was a retrospective observational study, including patients undergoing successful M-TEER (residual mitral regurgitation ≤2+ at discharge) for SMR at 13 European centers and with complete echocardiographic data at baseline and short-term follow-up (30-180 days). RV-PA coupling was assessed with the use of echocardiography as the ratio of tricuspid annular plane systolic excursion to pulmonary artery systolic pressure (TAPSE/PASP). All-cause death was assessed at the longest available follow-up starting from the time of the echocardiographic reassessment. RESULTS: Among 501 patients included, 331 (66%) improved their TAPSE/PASP after M-TEER (responders) at short-term follow-up (median: 89 days; IQR: 43-159 days), whereas 170 (34%) did not (nonresponders). Lack of previous cardiac surgery, low postprocedural mitral mean gradient, low baseline TAPSE, high baseline PASP, and baseline tricuspid regurgitation were independently associated with TAPSE/PASP improvement after M-TEER. Compared with nonresponders, responders had lower New York Heart Association functional class and less heart failure hospitalizations at short-term follow-up. Improvement in TAPSE/PASP was independently associated with reduced risk of mortality at long-term follow-up (584 days; IQR: 191-1,243 days) (HR: 0.65 [95% CI: 0.42-0.92]; P = 0.017). CONCLUSIONS: In patients with SMR, improvement in TAPSE/PASP after successful M-TEER is predicted by baseline clinical and echocardiographic variables and postprocedural mitral gradient, and is associated with a better outcome.


Assuntos
Artéria Pulmonar , Humanos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Valor Preditivo dos Testes
3.
Eur J Heart Fail ; 24(11): 2175-2184, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36482160

RESUMO

AIM: To evaluate short-term changes in tricuspid regurgitation (TR) after transcatheter edge-to-edge mitral valve repair (M-TEER) in secondary mitral regurgitation (SMR), their predictors and impact on mortality. METHODS AND RESULTS: This is a retrospective analysis of SMR patients undergoing successful M-TEER (post-procedural mitral regurgitation ≤2+) at 13 European centres. Among 503 patients evaluated 79 (interquartile range [IQR] 40-152) days after M-TEER, 173 (35%) showed ≥1 degree of TR improvement, 97 (19%) had worsening of TR, and 233 (46%) remained unchanged. Smaller baseline left atrial diameter and residual mitral regurgitation 0/1+ were independent predictors of TR ≤2+ after M-TEER. There was a significant association between TR changes and New York Heart Association class and pulmonary artery systolic pressure decrease at echocardiographic re-assessment. At a median follow-up of 590 (IQR 209-1103) days from short-term echocardiographic re-assessment, all-cause mortality was lower in patients with improved compared to those with unchanged/worsened TR (29.6% vs. 42.3% at 3 years; log-rank p = 0.034). Baseline TR severity was not associated with mortality, whereas TR 0/1+ and 2+ at short-term follow-up was associated with lower all-cause mortality compared to TR 3/4+ (30.6% and 35.6% vs. 55.6% at 3 years; p < 0.001). A TR ≤2+ after M-TEER was independently associated with a 42% decreased risk of mortality (p = 0.011). CONCLUSION: More than one third of patients with SMR undergoing successful M-TEER experienced an improvement in TR. Pre-procedural TR was not associated with outcome, but a TR ≤2+ at short-term follow-up was independently associated with long-term mortality. Optimal M-TEER result and a small left atrium were associated with a higher likelihood of TR ≤2+ after M-TEER.


Assuntos
Insuficiência Cardíaca , Valva Mitral , Humanos , Estudos Retrospectivos
4.
Ups J Med Sci ; 1272022.
Artigo em Inglês | MEDLINE | ID: mdl-35440973

RESUMO

Background: Wild-type transthyretin amyloidosis is a systemic disease with predominantly cardiac symptoms. The aim of this study was to assess the short-term prognosis of these patients through contractile reserve measured by stress echocardiography, given the usefulness that this parameter has demonstrated in other populations. We considered major events as death from any cause and hospitalization for heart failure. Material and methods: We conducted a study with a 1-year follow-up in 11 patients who were proposed to undergo a stress echocardiogram, with the follow-up as usual according to their doctor. We excluded pacemaker wearers, patients with permanent atrial fibrillation, those incapable of exertion at low loads, and those with poor acoustic windows. Results: We found that contractile reserve estimated by right ventricular free wall longitudinal strain is correlated with a lower rate of death (all of them cardiovascular deaths) and hospitalizations for heart failure. Conclusions: Contractile reserve assessed by right ventricular free wall longitudinal strain is a predictor of major events in patients with wild-type transthyretin cardiac amyloidosis.


Assuntos
Neuropatias Amiloides Familiares , Insuficiência Cardíaca , Neuropatias Amiloides Familiares/diagnóstico por imagem , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Prognóstico
5.
Int J Cardiol ; 352: 125-130, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35092759

RESUMO

BACKGROUND: Increased collagen cross-linking (CCL) has been described in hypertensive cardiomyopathy by means of reduced serum ratio of serum carboxyterminal telopeptide of collagen type I (CITP) to matrix metalloproteinase-1 (MMP1). Previous studies have demonstrated the existence of primary impaired diastole in patients with Marfan syndrome (MFS), but little is known about the pathophysiology of this condition. METHODS: 60 MFS patients (without previous cardiovascular surgery or significant valvular regurgitation) and 24 healthy controls (age and sex-matched) were enrolled. All participants underwent a comprehensive transthoracic echocardiographic study, including left atrial and left ventricular speckle-tracking strain analysis. CITP and MMP1 were measured in peripheral blood. RESULTS: All participants had normal diastolic function according to guidelines. Peak left atrial strain in the reservoir phase (LASr) was significantly reduced in the MFS cohort compared to controls (32.2 ± 9.4 vs 43.9 ± 7.0%; p < 0.001). Serum CITP and CITP:MMP1 ratio were lower among MFS patients, showing significant correlations with LASr (R = 0.311; p = 0.020 and R = 0.437; p = 0.001, respectively). The MFS cohort was divided into quartiles of LASr. MFS patients in the lowest quartile of LASr (<26%) had significantly lower values of CITP:MMP1 ratio compared to the other quartiles. CONCLUSIONS: The analysis of serum biomarkers revealed the presence of increased CCL in association with reduced LASr in the MFS cohort. Our results suggest that excessive CCL may play a role in the development of primary myocardial impairment in these patients. Future studies are needed to confirm our findings and evaluate the prognostic role of CCL markers in the MFS population.


Assuntos
Síndrome de Marfan , Biomarcadores , Colágeno Tipo I , Diástole , Feminino , Humanos , Masculino , Síndrome de Marfan/complicações , Síndrome de Marfan/fisiopatologia , Miocárdio
7.
Int J Cardiovasc Imaging ; 37(9): 2735-2745, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33871735

RESUMO

Previous studies using conventional echocardiographic measurements have reported subclinical left ventricular (LV) diastolic abnormalities in patients with Marfan syndrome (MFS). Left atrial (LA) strain allows an accurate categorization of LV diastolic dysfunction. We aimed to characterize LV myocardial performance in a cohort of MFS patients using STE-derived measurements (LV and LA strain) along with conventional echocardiographic parameters. We studied 127 adult patients with MFS (no prior cardiac surgery or significant valvular regurgitation) and 38 healthy controls. We performed detailed echocardiograms and selected left atrial reservoir strain (LASr) as a surrogate of impaired relaxation. Additionally, we searched for possible determinants of LASr in patients with MFS, with a special focus on the elastic properties of the aorta. In spite of lower E-wave, septal and lateral e' velocities and average E/e' ratio in MFS patients, all participants had normal diastolic function according to current guidelines. MFS patients exhibited reduced LV global longitudinal strain (19.3 ± 2.6 vs 21.6 ± 2.1%, p < 0.001) and reduced LASr (32.9 ± 8.5 vs 43.3 ± 7.8%, p < 0.001) compared to controls. In the MFS cohort, we found weak significant (p < 0.05) correlations between LASr and certain parameters: E/A ratio (R = 0.258), E wave (R = 0.226), aortic distensibility (R = 0.222), stiffness index (R = - 0.216), LV ejection fraction (R = 0.214), lateral e' (R = 0.210), LV end-systolic volume index (R = - 0.210), LV global longitudinal strain (R = 0.201), septal e' (R = 0.185). After multivariate analysis, only LV end-systolic volume index and E/A ratio maintained a weak independent association with LASr (R = - 0.220; p = 0.017 and R = 0.199; p = 0.046, respectively). In conclusion, LASr is reduced in patients with MFS, which may represent an early stage of LV diastolic dysfunction. LASr is not determined by the elastic properties of the aorta, suggesting that impaired myocardial relaxation is a primary condition in MFS.


Assuntos
Síndrome de Marfan , Disfunção Ventricular Esquerda , Diástole , Humanos , Síndrome de Marfan/diagnóstico , Síndrome de Marfan/diagnóstico por imagem , Valor Preditivo dos Testes , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Esquerda
8.
Int J Cardiol ; 333: 233-238, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-33727123

RESUMO

BACKGROUND: Current evidence suggests that Brugada syndrome (BrS), far from being a purely electrical condition, is associated with subtle mechanical abnormalities primarily affecting the right ventricle (RV). We aimed to characterize RV function in BrS and investigate the echocardiographic profile of patients with arrhythmic events, with a special focus on parameters of RV dyssynchrony using speckle-tracking echocardiography (STE). METHODS: An echocardiogram was performed in 71 BrS patients and 25 healthy controls. STE was performed to assess regional and global RV mechanics, including RV outflow tract shortening (RVOTS). RVOT contraction time was considered to calculate the modified RV mechanical dispersion (RVMDm). Arrhythmic events were prospectively evaluated in the BrS cohort. RESULTS: Compared to controls, BrS patients showed subtle contractile abnormalities, including impaired RV longitudinal strain, higher RV index of myocardial performance (RIMP) and lower RVOTS. BrS patients also exhibited a greater contraction delay between the lateral and the septal aspect of the RV. After a median follow-up of 7.3 year (IQR 5.2-10.8), 6 patients presented malignant arrhythmic events. RIMP >0.50, RVOTS <16.2% and RVMDm > 42 ms showed high sensitivity for the identification of BrS patients with arrhythmic events during follow-up. CONCLUSIONS: Subtle RV mechanical abnormalities were present in BrS patients. RIMP and RVOTS, a novel STE-derived parameter, were found to be sensitive markers of arrhythmic events. Adding the RVOT contraction time to the analysis of RVMD may help identify patients at higher risk, reflecting the importance of the RVOT mechanical substrate in the assessment of the arrhythmic risk in BrS.


Assuntos
Síndrome de Brugada , Disfunção Ventricular Direita , Síndrome de Brugada/diagnóstico por imagem , Ecocardiografia , Eletrocardiografia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita
9.
Eur Heart J Cardiovasc Imaging ; 23(1): 61-70, 2021 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-33496314

RESUMO

AIMS: The aim of this study is to investigate determinants of left atrial (LA) reservoir and pump strain and if these parameters may serve as non-invasive markers of left ventricular (LV) filling pressure. METHODS AND RESULTS: In a multicentre study of 322 patients with cardiovascular disease of different aetiologies, LA strain and other echocardiographic parameters were compared with invasively measured LV filling pressure. The strongest determinants of LA reservoir and pump strain were LV global longitudinal strain (GLS) (r-values 0.64 and 0.51, respectively) and LV filling pressure (r-values -0.52 and -0.57, respectively). Left atrial volume was another independent, but weaker determinant of both LA strains. For both LA strains, association with LV filling pressure was strongest in patients with reduced LV ejection fraction. Left atrial reservoir strain <18% and LA pump strain <8% predicted elevated LV filling pressure better (P < 0.05) than LA volume and conventional Doppler parameters. Accuracy to identify elevated LV filling pressure was 75% for LA reservoir strain alone and 72% for pump strain alone. When combined with conventional parameters, accuracy was 82% for both LA strains. In patients with normal LV systolic function by GLS, LA pump strain >14% identified normal LV filling pressure with 92% accuracy. CONCLUSION: Left atrial reservoir and pump strain are determined predominantly by LV GLS and filling pressure. Accuracy of LA strains to identify elevated LV filling pressure was best in patients with reduced LV systolic function. High values of LA pump strain, however, identified normal LV filling pressure with good accuracy in patients with normal systolic function.


Assuntos
Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Ecocardiografia , Átrios do Coração/diagnóstico por imagem , Humanos , Volume Sistólico , Sístole , Disfunção Ventricular Esquerda/diagnóstico por imagem
13.
Rev Esp Cardiol (Engl Ed) ; 74(4): 337-344, 2021 Apr.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32205100

RESUMO

INTRODUCTION AND OBJECTIVES: Two-dimensional speckle-tracking echocardiography has emerged as a promising alternative to endomyocardial biopsy to rule out acute cellular rejection after orthotopic heart transplantation (OHT) in single center studies. In an original cohort, 15.5% and 17% of cutoff points for left ventricular global longitudinal strain (LVGLS) and free-wall right ventricular longitudinal strain, respectively, achieved 100% negative predictive value to exclude moderate or severe acute cellular rejection (ACR ≥ 2R). Our objective was to demonstrate the usefulness of speckle-tracking and validate these cutoff points in an external cohort. METHODS: A prospective, multicenter study that included patients who were monitored during their first year after OHT was conducted. Echocardiographic studies analyzed by local investigators were compared with simultaneous paired endomyocardial biopsies samples. RESULTS: A total of 501 endomyocardial biopsy-echocardiographic studies were included in 99 patients. ACR≥2R was present in 7.4% of samples. LVGLS and free-wall right ventricular longitudinal strain were significantly reduced during ACR≥2R on univariate analysis. On multivariate analysis, LVGLS was independently associated with the presence of ACR≥2R. The original cutoff points demonstrated a negative predictive value of 94.3% to exclude ACR≥2R. CONCLUSIONS: This study maintained a strong negative predictive value to exclude ACR≥2R after OHT and LVGLS was independently associated with the presence of ACR≥2R. We propose the use of speckle-tracking, especially LVGLS, as part of the noninvasive diagnosis and management of ACR.


Assuntos
Transplante de Coração , Ecocardiografia , Rejeição de Enxerto/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Humanos , Estudos Prospectivos
15.
Rev. colomb. cardiol ; 27(5): 405-413, sep.-oct. 2020. tab, graf
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1289250

RESUMO

Resumen Introducción: en los procedimientos de extracción de electrodos, la vía femoral se usa cuando la vía superior ha fracasado. Objetivo: describir la incidencia, el éxito, las complicaciones y los predictores de uso de la vía femoral. Métodos: se realizó un análisis de la incidencia del uso de la vía femoral y los factores predictores en pacientes a quienes se les realizó extracción de electrodos entre noviembre de 2011 y noviembre de 2017. Resultados: se incluyeron 85 pacientes, con edad media de 62,36 ± 11,15 años. El 38,9% de los dispositivos eran marcapasos. Se extrajeron 135 electrodos, 59,3% de fijación pasiva. La mediana de tiempo desde el implante fue de 102 (60-174) meses. Se empleó la ruta femoral en el 25,9% de los procedimientos. Se obtuvo éxito clínico en el 92,9% de los pacientes. La extracción no fue exitosa en el 22,7% de los procedimientos cuando se usó la vía femoral, en comparación con el 1,6% cuando se usó la vía superior (p 0,004). La extracción no fue completa en el 36,4% de los procedimientos cuando se empleó la vía femoral en comparación con el 9,5% por vía superior (p 0,007). Los factores que predijeron el empleo de la ruta femoral fueron la presencia de electrodos de fijación pasiva [OR IC 95% 13,69 (3,06-62,5) p 0,001] y el tiempo desde el implante del electrodo [OR IC 95% por cada 10 meses 1,04 (1,00-1,09) p 0,044]. Conclusiones: se empleó la ruta femoral en el 25,9% de los procedimientos. No fue eficaz en el 22,7% de las intervenciones. Los factores que predijeron su utilización fueron la presencia de electrodos de fijación pasiva y el tiempo desde el implante del electrodo.


Abstract Introduction: The femoral route is used in electrode removal procedures when the upper route has failed. Objective: To describe the incidence, success rate, complications and predictive factors for the use of the femoral route. Methods: An analysis was performed on the incidence of use of the femoral route and the predictive factors in patients in whom electrode removal was carried out between November 2011 and November 2017. Results: The study included 85 patients with a mean age of 62.36 ± 11.5 years. Pacemakers made up 38.9% of the devices. A total of 135 electrodes, 59.3% of passive fixation, were removed. The median time since the implant was 102 (60-174) months. The femoral route was used in 25.9% of the procedures. Clinical success was achieved in 92.9% of the patients. The removal was not successful in 22.7% of the procedures when the femoral route was used, compared to 1.6% when the upper route was used (P = .004). The removal was not completed in 36.4% of the procedures when the femoral route was used, compared to 9.5% with the upper route (P = .007). The factors that predicted the use of the femoral route were the presence of passive-fixation electrodes (OR = 13.69: 95% CI; 3.06 - 62.5, P = .001), and the time since the electrodes were implanted (OR = 1.04, 95% CI; 1.00 - 1.09, P = .044, for every 10 months). Conclusions: The femoral route was employed in 25.9% of the procedures. It was not effective in 22.7% of the interventions. The factors that predicted its use were the presence of passive-fixation electrodes and the time since the electrode implant.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Eletrodos , Veia Femoral , Incidência , Equipamentos e Provisões
16.
J Am Soc Echocardiogr ; 32(7): 845-853.e1, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31078369

RESUMO

BACKGROUND: Cardiac amyloidosis (CA) causes restrictive cardiomyopathy usually associated with a poor prognosis. Two subtypes predominate: systemic light-chain CA (ALCA) and transthyretin-derived CA (either wild type transthyretin amyloidosis [TTRwt] or mutant transthyretin amyloidosis [TTRm]). Left ventricular (LV) apical sparing has been extensively studied using speckle-tracking echocardiography for diagnosis, but the right ventricular (RV) deformation pattern has not been described. The aims of this study were to characterize RV involvement in patients with CA and to identify parameters that may help in the differential diagnosis between ALCA and transthyretin-derived CA subtypes. METHODS: Seventy-eight patients with CA (47 with ALCA, 20 with TTRwt, and 11 with TTRm) and 24 healthy control subjects were included. Global longitudinal strain (GLS) was analyzed in 16 LV and six RV segments. LV and RV apical ratios (ARs) were obtained. GLS was expressed as an absolute value. RESULTS: LV GLS and free-wall RV longitudinal strain were impaired in all patients (LV GLS: 11.9 ± 2.9% in ALCA, 12.5 ± 3.8% in TTRwt, 14.9 ± 2.7% in TTRm, and 21.9 ± 2.6% in control subjects [P < .01]; free-wall RV longitudinal strain: 13.1 ± 6.8%, 14.9 ± 4.5%, 17.2 ± 3.4%, and 22.1 ± 3.1%, respectively [P < .01]). LV and RV ARs were higher in ALCA compared with both TTRwt, TTRm, and control subjects (LV AR: 1.1 ± 0.2, 0.8 ± 0.2, 0.9 ± 0.1, and 0.7 ± 0.1, respectively [P < .001]; RV AR: 1.1 ± 0.2, 0.6 ± 0.2, 0.6 ± 0.1, and 0.6 ± 0.1, respectively [P < .001]). Cutoff values of LV AR > 0.96 and RV AR > 0.8 showed high accuracy to differentiate between ALCA and transthyretin-derived CA. CONCLUSIONS: RV dysfunction is common in patients with CA. Analysis of RV strain showed an apical sparing pattern, as previously described in the left ventricle, with a higher AR as a specific finding in patients with ALCA. RV AR may be a parameter that can differentiate the subtypes of amyloidosis on the basis of speckle-tracking echocardiographic analysis.


Assuntos
Neuropatias Amiloides Familiares/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Ecocardiografia/métodos , Amiloidose de Cadeia Leve de Imunoglobulina/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Idoso , Neuropatias Amiloides Familiares/fisiopatologia , Cardiomiopatias/fisiopatologia , Estudos de Casos e Controles , Diagnóstico Diferencial , Feminino , Humanos , Amiloidose de Cadeia Leve de Imunoglobulina/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Disfunção Ventricular Direita/fisiopatologia
17.
Rev Esp Cardiol (Engl Ed) ; 70(9): 727-735, 2017 Sep.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28366497

RESUMO

INTRODUCTION AND OBJECTIVES: Most long-term ventricular assist devices (VADs) that are currently implanted are intracorporeal continuous-flow devices. Their main limitations include their high cost and inability to provide biventricular support. The aim of this study was to describe the results of using paracorporeal pulsatile-flow VADs as a bridge to transplant (BTT) in adult patients. METHODS: Retrospective analysis of the characteristics, complications, and outcomes of a single-center case series of consecutive patients treated with the EXCOR VAD as BTT between 2009 and 2015. RESULTS: During the study period, 25 VADs were implanted, 6 of them biventricular. Ventricular assist devices were indicated directly as a BTT in 12 patients and as a bridge to decision in 13 due to the presence of potentially reversible contraindications or chance of heart function recovery. Twenty patients (80%) were successfully bridged to heart transplant after a median of 112 days (range, 8-239). The main complications included infectious (52% of patients), neurological events (32%, half of them fatal), bleeding (28%), and VAD malfunction requiring component replacement (28%). CONCLUSIONS: Eighty percent of patients with the EXCOR VAD as BTT achieved the goal after an average of almost 4 months of support. The most frequent complications were infectious, and the most severe were neurological. In our enivonment, the use of these pulsatile-flow VAD as BTT is a feasible strategy that obtains similar outcomes to those of intracorporeal continuous-flow devices.


Assuntos
Insuficiência Cardíaca/terapia , Transplante de Coração , Coração Auxiliar , Adulto , Feminino , Hemorragia/epidemiologia , Humanos , Infecções/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Trombose/epidemiologia , Fatores de Tempo , Resultado do Tratamento
18.
Echocardiography ; 33(5): 703-13, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26806917

RESUMO

BACKGROUND: Evolution of left and right ventricular (LV and RV) function after heart transplantation (HT) has not been well described. Our objective was to evaluate the evolution of echocardiographic parameters of both ventricles along the first 2 years after HT. METHODS: We followed 31 HT recipients with serial echocardiograms for up to 2 years. Echocardiograms with AR ≥2R were excluded. We analyzed LV global longitudinal strain (LV GLS) by speckle tracking in 12 segments in four- and two-chamber views and RV global longitudinal strain (RV GLS) in four-chamber view. Control group included 25 healthy volunteers. RESULTS: Even though LVEF was preserved, LV GLS was reduced early post-HT (-17.7 ± 3.0 in HT vs. -20.7 ± 2.8 in controls, P = 0.02), improving progressively until its complete normalization 2 years after HT (-20.0 ± 3.7 vs. -20.7 ± 2.8, P = 0.60). TAPSE was impaired in the early post-HT period and increased progressively (11.9 ± 2.9 mm at baseline vs. 19.0 ± 3.6 mm at 2 years, P < 0.001). RV GLS rose during follow-up as well (-17.4 ± 3.5 at baseline vs. -22.6 ± 3.3 at 2 years, P = 0.001), reaching normal values 1 year after HT. CONCLUSION: In this series of HT recipients with uneventful postoperative course, LV and RV GLS values were significantly reduced early after HT and improved progressively until their complete normalization two and 1 year after HT, respectively. This is the first study to show a full recovery of LV and RV deformation parameters and offers "normal" strain values that, if confirmed in larger studies, could be useful for monitoring the evolution of HT recipients.


Assuntos
Ecocardiografia/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Disfunção Ventricular/diagnóstico por imagem , Disfunção Ventricular/prevenção & controle , Técnicas de Imagem por Elasticidade/métodos , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular/etiologia
19.
J Am Soc Echocardiogr ; 28(10): 1149-56, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26165446

RESUMO

BACKGROUND: Acute cellular rejection (ACR) is still a relevant complication after orthotopic heart transplantation. The diagnosis of ACR is based on endomyocardial biopsy (EMB). Recent advances in two-dimensional strain imaging may allow early noninvasive detection of ACR. The objective of this study was to analyze the usefulness of conventional and new echocardiographic parameters to exclude ACR after orthotopic heart transplantation. METHODS: Thirty-four consecutive adult heart transplant recipients admitted to a single center between January 2010 and December 2012 for orthotopic heart transplantation were prospectively included. A total of 235 pairs of EMB and echocardiographic examination were performed. A median of seven studies per patient (interquartile range, six to eight studies per patient) were performed during the first year of follow-up. Classic echocardiographic parameters; speckle-tracking-derived left ventricular (LV) longitudinal, radial, and circumferential strain; and global and free wall right ventricular (RV) longitudinal strain were analyzed. RESULTS: ACR was detected in 26.4% of EMB samples (n = 62); 5.1% (n = 12) required specific treatment (ACR degree ≥ 2R). Lower absolute values of global LV longitudinal strain and free wall RV longitudinal strain were present in patients with ACR degree ≥ 2R compared with those without ACR (13.7 ± 2.7% vs 17.8 ± 3.4% and 16.6 ± 3.6% vs 23.3 ± 5.2%, respectively). An average LV longitudinal strain < 15.5% had 85.7% sensitivity, 81.4% specificity, 98.8% negative predictive value, 25.0% positive predictive value, and 81.7% accuracy for the presence of ACR degree ≥ 2R. Free wall RV longitudinal strain < 17% had 85.7% sensitivity, 91.1% specificity, 98.8% negative predictive value, 42.9% positive predictive value, and 90.7% accuracy for ACR degree ≥ 2R. Both variables were normal in 106 echocardiograms (57.6%); none of these patients presented with ACR degree ≥ 2R. CONCLUSIONS: The combination of two new echocardiographic measures, global LV and RV free wall longitudinal strain, may be able to identify a group of heart transplant patients who are unlikely to have ACR. If these findings are confirmed independently, it may be possible to use LV and RV strain measures as reliable tools to exclude ACR and to reduce the burden of repeated EMB.


Assuntos
Ecocardiografia/métodos , Rejeição de Enxerto/diagnóstico por imagem , Rejeição de Enxerto/patologia , Transplante de Coração/efeitos adversos , Processamento de Imagem Assistida por Computador , Doença Aguda , Adulto , Fatores Etários , Área Sob a Curva , Estudos de Coortes , Feminino , Rejeição de Enxerto/epidemiologia , Rejeição de Enxerto/imunologia , Transplante de Coração/métodos , Humanos , Imunidade Celular , Incidência , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Curva ROC , Medição de Risco , Sensibilidade e Especificidade , Fatores Sexuais , Espanha , Imunologia de Transplantes/fisiologia , Disfunção Ventricular Esquerda/diagnóstico por imagem
20.
Rev Esp Cardiol (Engl Ed) ; 67(11): 883-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25443812

RESUMO

INTRODUCTION AND OBJECTIVES: Cardiac resynchronization therapy is associated with improved quality of life and reduced morbidity and mortality in patients with severe ventricular dysfunction and wide QRS. However, its role in the reduction of ventricular arrhythmias is more controversial. METHODS: We compared the incidence of ventricular arrhythmias in patients who were undergoing cardiac resynchronization therapy with an implantable cardioverter-defibrillator in terms of the degree of echocardiographic response to resynchronization. Patients were classified in 3 subgroups;super-responders, responders, and nonresponders. RESULTS: We included 196 patients who were followed up for a median 30.1 months [interquartile range, 18.0-55.1 months]. We recorded the presence of ventricular arrhythmias in 37 patients (18.8%); 3 patients (5.9%) in the super-responder group had ventricular arrhythmias vs 14 (22.2%) among the responders and 20 (24.4%) in the group of nonresponders (P = .025). In multivariate analysis, the only independent predictors of the appearance of ventricular arrhythmias were secondary-prevention device implantation (odds ratio = 4.04; 95% confidence interval, 1.52-10.75; P=.005), absence of echocardiographic super-response (odds ratio=3.81; 95% confidence interval, 1.04-13.93; P=043), QRS >160 ms (odds ratio=2.39; 95% confidence interval, 1.00-1.35; P=.049) and treatment with amiodarone (odds ratio=2.47; 95% confidence interval, 1.03-5.91; P=.041). CONCLUSIONS: The patients classified as super-responders to cardiac resynchronization therapy had a significant reduction in incidence of ventricular arrhythmias by comparison with the other patients. Despite this, arrhythmic episodes do not completely disappear in this subgroup.


Assuntos
Arritmias Cardíacas/terapia , Terapia de Ressincronização Cardíaca , Arritmias Cardíacas/fisiopatologia , Desfibriladores Implantáveis , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA