Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
IEEE J Transl Eng Health Med ; 12: 268-278, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38410182

RESUMO

Executive functions (EFs) are neurocognitive processes planning and regulating daily life actions. Performance of two simultaneous tasks, requiring the same cognitive resources, lead to a cognitive fatigue. Several studies investigated cognitive-motor task and the interference during walking, highlighting an increasing risk of falls especially in elderly and people with neurological diseases. A few studies instrumentally explored relationship between activation-no-activation of two EFs (working memory and inhibition) and spatial-temporal gait parameters. Aim of our study was to detect activation of inhibition and working memory during progressive difficulty levels of cognitive tasks and spontaneous walking using, respectively, wireless electroencephalography (EEG) and 3D-gait analysis. Thirteen healthy subjects were recruited. Two cognitive tasks were performed, activating inhibition (Go-NoGo) and working memory (N-back). EEG features (absolute and relative power in different bands) and kinematic parameters (7 spatial-temporal ones and Gait Variable Score for 9 range of motion of lower limbs) were analyzed. A significant decrease of stride length and an increase of external-rotation of foot progression were found during dual task with Go-NoGo. Moreover, a significant correlation was found between the relative power in the delta band at channels Fz, C4 and progressive difficulty levels of Go-NoGo (activating inhibition) during walking, whereas working memory showed no correlation. This study reinforces the hypothesis of the prevalent involvement of inhibition with respect to working memory during dual task walking and reveals specific kinematic adaptations. The foundations for EEG-based monitoring of cognitive processes involved in gait are laid. Clinical and Translational Impact Statement: Clinical and instrumental evaluation and training of executive functions (as inhibition), during cognitive-motor task, could be useful for rehabilitation treatment of gait disorder in elderly and people with neurological disease.


Assuntos
Função Executiva , Análise da Marcha , Humanos , Idoso , Função Executiva/fisiologia , Estudos de Viabilidade , Marcha/fisiologia , Caminhada/fisiologia
2.
J Vis Exp ; (197)2023 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-37486136

RESUMO

The present work focuses on how to build a wearable brain-computer interface (BCI). BCIs are a novel means of human-computer interaction that relies on direct measurements of brain signals to assist both people with disabilities and those who are able-bodied. Application examples include robotic control, industrial inspection, and neurorehabilitation. Notably, recent studies have shown that steady-state visually evoked potentials (SSVEPs) are particularly suited for communication and control applications, and efforts are currently being made to bring BCI technology into daily life. To achieve this aim, the final system must rely on wearable, portable, and low-cost instrumentation. In exploiting SSVEPs, a flickering visual stimulus with fixed frequencies is required. Thus, in considering daily-life constraints, the possibility to provide visual stimuli by means of smart glasses was explored in this study. Moreover, to detect the elicited potentials, a commercial device for electroencephalography (EEG) was considered. This consists of a single differential channel with dry electrodes (no conductive gel), thus achieving the utmost wearability and portability. In such a BCI, the user can interact with the smart glasses by merely staring at icons appearing on the display. Upon this simple principle, a user-friendly, low-cost BCI was built by integrating extended reality (XR) glasses with a commercially available EEG device. The functionality of this wearable XR-BCI was examined with an experimental campaign involving 20 subjects. The classification accuracy was between 80%-95% on average depending on the stimulation time. Given these results, the system can be used as a human-machine interface for industrial inspection but also for rehabilitation in ADHD and autism.


Assuntos
Interfaces Cérebro-Computador , Dispositivos Eletrônicos Vestíveis , Humanos , Potenciais Evocados Visuais , Interface Usuário-Computador , Eletroencefalografia , Atenção à Saúde , Estimulação Luminosa
3.
Diagnostics (Basel) ; 12(7)2022 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-35885583

RESUMO

A method to detect the presence of infection after Total Joint Arthroplasty is presented. The method is based on Electrical Bioimpedance Spectroscopy and guarantees low latency, non-invasiveness, and cheapness with respect to the state of art. Experimental measurements were carried out on a singular patient who had already undergone bilateral Total Knee Arthroplasty. He was affected by a hematogenous Periprosthetic Joint Infections on the left knee. The right knee was adopted as the reference. Measurements were acquired once before the surgical procedure (Diagnosis Phase) and twice in the postoperative phases (Monitoring Phase). The most relevant frequency range, for diagnosis and monitoring phases, was found to be between 10 kHz to 50 kHz. The healing trend predicted by the decrease of impedance magnitude spectrum was reflected in clinical and laboratory results. In addition, one month after the last acquisition (two months after the surgery), the patient fully recovered, confirming the prediction of the Electrical Bioimpedance Spectroscopy technique.

4.
Sensors (Basel) ; 22(13)2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35808424

RESUMO

A systematic review on electroencephalographic (EEG)-based feature extraction strategies to diagnosis and therapy of attention deficit hyperactivity disorder (ADHD) in children is presented. The analysis is realized at an executive function level to improve the research of neurocorrelates of heterogeneous disorders such as ADHD. The Quality Assessment Tool for Quantitative Studies (QATQS) and field-weighted citation impact metric (Scopus) were used to assess the methodological rigor of the studies and their impact on the scientific community, respectively. One hundred and one articles, concerning the diagnostics and therapy of ADHD children aged from 8 to 14, were collected. Event-related potential components were mainly exploited for executive functions related to the cluster inhibition, whereas band power spectral density is the most considered EEG feature for executive functions related to the cluster working memory. This review identifies the most used (also by rigorous and relevant articles) EEG signal processing strategies for executive function assessment in ADHD.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade , Eletroencefalografia , Adolescente , Transtorno do Deficit de Atenção com Hiperatividade/diagnóstico , Transtorno do Deficit de Atenção com Hiperatividade/fisiopatologia , Transtorno do Deficit de Atenção com Hiperatividade/terapia , Criança , Potenciais Evocados/fisiologia , Humanos , Memória de Curto Prazo/fisiologia
5.
Sci Rep ; 12(1): 5857, 2022 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-35393470

RESUMO

A wearable system for the personalized EEG-based detection of engagement in learning 4.0 is proposed. In particular, the effectiveness of the proposed solution is assessed by means of the classification accuracy in predicting engagement. The system can be used to make an automated teaching platform adaptable to the user, by managing eventual drops in the cognitive and emotional engagement. The effectiveness of the learning process mainly depends on the engagement level of the learner. In case of distraction, lack of interest or superficial participation, the teaching strategy could be personalized by an automatic modulation of contents and communication strategies. The system is validated by an experimental case study on twenty-one students. The experimental task was to learn how a specific human-machine interface works. Both the cognitive and motor skills of participants were involved. De facto standard stimuli, namely (1) cognitive task (Continuous Performance Test), (2) music background (Music Emotion Recognition-MER database), and (3) social feedback (Hermans and De Houwer database), were employed to guarantee a metrologically founded reference. In within-subject approach, the proposed signal processing pipeline (Filter bank, Common Spatial Pattern, and Support Vector Machine), reaches almost 77% average accuracy, in detecting both cognitive and emotional engagement.


Assuntos
Eletroencefalografia , Processamento de Sinais Assistido por Computador , Emoções , Humanos , Estudantes , Máquina de Vetores de Suporte
6.
Sci Rep ; 12(1): 673, 2022 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-35027630

RESUMO

A personalized model of the human knee for enhancing the inter-individual reproducibility of a measurement method for monitoring Non-Steroidal Anti-Inflammatory Drugs (NSAIDs) after transdermal delivery is proposed. The model is based on the solution of Maxwell Equations in the electric-quasi-stationary limit via Finite Element Analysis. The dimensions of the custom geometry are estimated on the basis of knee circumference at the patella, body mass index, and sex of each individual. An optimization algorithm allows to find out the electrical parameters of each subject by experimental impedance spectroscopy data. Muscular tissues were characterized anisotropically, by extracting Cole-Cole equation parameters from experimental data acquired with twofold excitation, both transversal and parallel to tissue fibers. A sensitivity and optimization analysis aiming at reducing computational burden in model customization achieved a worst-case reconstruction error lower than 5%. The personalized knee model and the optimization algorithm were validated in vivo by an experimental campaign on thirty volunteers, 67% healthy and 33% affected by knee osteoarthritis (Kellgren-Lawrence grade ranging in [1,4]), with an average error of 3%.


Assuntos
Anti-Inflamatórios não Esteroides/administração & dosagem , Anti-Inflamatórios não Esteroides/farmacocinética , Articulação do Joelho/metabolismo , Osteoartrite do Joelho/tratamento farmacológico , Osteoartrite do Joelho/metabolismo , Administração Cutânea , Algoritmos , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Modelos Anatômicos , Reprodutibilidade dos Testes
7.
Sci Rep ; 11(1): 21615, 2021 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-34732756

RESUMO

A methodological contribution to a reproducible Measurement of Emotions for an EEG-based system is proposed. Emotional Valence detection is the suggested use case. Valence detection occurs along the interval scale theorized by the Circumplex Model of emotions. The binary choice, positive valence vs negative valence, represents a first step towards the adoption of a metric scale with a finer resolution. EEG signals were acquired through a 8-channel dry electrode cap. An implicit-more controlled EEG paradigm was employed to elicit emotional valence through the passive view of standardized visual stimuli (i.e., Oasis dataset) in 25 volunteers without depressive disorders. Results from the Self Assessment Manikin questionnaire confirmed the compatibility of the experimental sample with that of Oasis. Two different strategies for feature extraction were compared: (i) based on a-priory knowledge (i.e., Hemispheric Asymmetry Theories), and (ii) automated (i.e., a pipeline of a custom 12-band Filter Bank and Common Spatial Pattern). An average within-subject accuracy of 96.1 %, was obtained by a shallow Artificial Neural Network, while k-Nearest Neighbors allowed to obtain a cross-subject accuracy equal to 80.2%.


Assuntos
Algoritmos , Eletroencefalografia/métodos , Emoções/fisiologia , Modelos Psicológicos , Redes Neurais de Computação , Processamento de Sinais Assistido por Computador , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
8.
Sci Rep ; 11(1): 5297, 2021 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-33674657

RESUMO

A method for EEG-based distraction detection during motor-rehabilitation tasks is proposed. A wireless cap guarantees very high wearability with dry electrodes and a low number of channels. Experimental validation is performed on a dataset from 17 volunteers. Different feature extractions from spatial, temporal, and frequency domain and classification strategies were evaluated. The performances of five supervised classifiers in discriminating between attention on pure movement and with distractors were compared. A k-Nearest Neighbors classifier achieved an accuracy of 92.8 ± 1.6%. In this last case, the feature extraction is based on a custom 12 pass-band Filter-Bank (FB) and the Common Spatial Pattern (CSP) algorithm. In particular, the mean Recall of classification (percentage of true positive in distraction detection) is higher than 92% and allows the therapist or an automated system to know when to stimulate the patient's attention for enhancing the therapy effectiveness.


Assuntos
Atenção/fisiologia , Eletroencefalografia/instrumentação , Atividade Motora/fisiologia , Reabilitação Neurológica/instrumentação , Reabilitação Neurológica/métodos , Dispositivos Eletrônicos Vestíveis , Tecnologia sem Fio/instrumentação , Adulto , Interfaces Cérebro-Computador , Confiabilidade dos Dados , Eletrodos , Feminino , Voluntários Saudáveis , Humanos , Imaginação/fisiologia , Masculino , Processamento de Sinais Assistido por Computador , Máquina de Vetores de Suporte , Adulto Jovem
9.
Sci Rep ; 10(1): 13656, 2020 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-32788632

RESUMO

An on-chip transducer, for monitoring noninvasively the insulin bio-availability in real time after administration in clinical diabetology, is proposed. The bioavailability is assessed as insulin decrease in situ after administration by means of local impedance measurement. Inter-and-intra individual reproducibility is enhanced by a personalized model, specific for the subject, identified and validated during each insulin administration. Such a real-time noninvasive bioavailability measurement allows to increase the accuracy of insulin bolus administration, by attenuating drawbacks of glycemic swings significantly. In the first part of this paper, the concept, the architecture, and the operation of the transducer, as well as details about its prototype, are illustrated. Then, the metrological characterization and validation are reported in laboratory, in vitro on eggplants, ex vivo on pig abdominal non-perfused muscle, and in vivo on a human subject, using injection as a reference subcutaneous delivery of insulin. Results of significant intra-individual reproducibility in vitro and ex vivo point out noteworthy scenarios for assessing insulin bioavailability in clinical diabetology.


Assuntos
Automonitorização da Glicemia/métodos , Glicemia/análise , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Animais , Disponibilidade Biológica , Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 1/patologia , Humanos , Hipoglicemiantes/metabolismo , Injeções Subcutâneas , Insulina/metabolismo , Suínos
10.
Sci Rep ; 7: 44647, 2017 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-28338008

RESUMO

The effectiveness in transdermal delivery of skin permeation strategies (e.g., chemical enhancers, vesicular carrier systems, sonophoresis, iontophoresis, and electroporation) is poorly investigated outside of laboratory. In therapeutic application, the lack of recognized techniques for measuring the actually-released drug affects the scientific concept itself of dosage for topically- and transdermally-delivered drugs. Here we prove the suitability of impedance measurement for assessing the amount of drug penetrated into the skin after transdermal delivery. In particular, the measured amount of drug depends linearly on the impedance magnitude variation normalized to the pre-treated value. Three experimental campaigns, based on the electrical analysis of the biological tissue behavior due to the drug delivery, are reported: (i) laboratory emulation on eggplants, (ii) ex-vivo tests on pig ears, and finally (iii) in-vivo tests on human volunteers. Results point out that the amount of delivered drug can be assessed by reasonable metrological performance through a unique measurement of the impedance magnitude at one single frequency. In particular, in-vivo results point out sensitivity of 23 ml-1, repeatability of 0.3%, non-linearity of 3.3%, and accuracy of 5.7%. Finally, the measurement resolution of 0.20 ml is compatible with clinical administration standards.


Assuntos
Espectroscopia Dielétrica/métodos , Ácido Hialurônico/farmacocinética , Polieletrólitos/farmacocinética , Absorção Cutânea/fisiologia , Pele/metabolismo , Administração Cutânea , Adulto , Animais , Orelha , Eletrodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Solanum melongena/metabolismo , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA