Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
PeerJ ; 12: e17293, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38770099

RESUMO

Background: Aniseikonia is a binocular vision disorder that has been associated with asthenopic symptoms. However, asthenopia has been evaluated with subjective tests that make difficult to determine the level of aniseikonia. This study aims to objectively evaluate the impact of induced aniseikonia at different levels on visual fatigue by measuring the orbicularis oculi muscle activity in the dominant and non-dominant eyes while performing a reading task. Methods: Twenty-four collegiate students (24.00 ± 3.86 years) participated in this study. Participants read a passage for 7 minutes under four degrees of aniseikonia (0%, 3%, 5% and 10%) at 50 cm. Orbicularis oculi muscle activity of the dominant and non-dominant eye was recorded by surface electromyography. In addition, visual discomfort was assessed after each task by completing a questionnaire. Results: Orbicularis oculi muscle activity increased under induced aniseikonia (i.e., greater values for the 10% condition in comparison to 0%, and 3% conditions (p = 0.034 and p = 0.023, respectively)). No statistically significant differences were observed in orbicularis oculi muscle activity for the time on task and between the dominant and non-dominant eyes. Additionally, higher levels of subjective visual discomfort were observed for lower degrees of induced aniseikonia. Conclusion: Induced aniseikonia increases visual fatigue at high aniseikonia degrees as measured by the orbicularis oculi muscle activity, and at low degrees as measured with subjective questionnaires. These findings may be of relevance to better understand the visual symptomatology of aniseikonia.


Assuntos
Aniseiconia , Eletromiografia , Leitura , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Aniseiconia/fisiopatologia , Músculos Oculomotores/fisiologia , Astenopia/fisiopatologia , Astenopia/etiologia , Computadores , Músculos Faciais/fisiologia
2.
Clin Exp Optom ; : 1-12, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561016

RESUMO

CLINICAL RELEVANCE: The results of this study present novel insights into the impact of spherical and astigmatic refractive errors on overall, corneal and internal aberrations and may provide a clear understanding of the emmetropisation process and the development of visual function. BACKGROUND: This study aimed to assess the association between overall, corneal and internal higher-order aberrations and the spherical and astigmatic components (magnitude and angle) of refractive error in a large sample of children. METHODS: A total of 311 children aged 7 - 8 years old were classified based on spherical equivalent refraction (myopic, emmetropic and hyperopic); magnitude of astigmatism (none, low and moderate); and angle of astigmatism (with-the-rule, against-the-rule and oblique). Refractive error and overall, corneal and internal higher-order aberrations were measured using the OPD-Scan III workstation. RESULTS: Regarding spherical equivalent refraction, myopic eyes had greater root mean square (RMS) overall higher-order values, total spherical, tetrafoil and secondary astigmatism aberrations, and internal higher-order, total spherical and tetrafoil aberrations in comparison to emmetropic eyes. The magnitude of astigmatism was positively associated with all overall RMS aberrations and with internal higher order, coma, total coma, total spherical and tetrafoil aberrations. Eyes with with-the-rule astigmatism showed higher RMS values of coma and total coma compared to eyes with against-the-rule and oblique astigmatism. CONCLUSIONS: Higher-order aberrations are dependent on the spherical as well as astigmatic components of refractive error. These findings enhance the current understanding of the emmetropisation process and visual function development.

3.
Ophthalmic Physiol Opt ; 44(1): 23-31, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37641939

RESUMO

INTRODUCTION: Despite the critical importance of binocular vision integrity in daily activities, there exists limited understanding of how alterations in binocular vision integrity impact gaze behaviour during dynamic, complex psychomotor skills. This study aimed to measure how alterations in binocular vision integrity, created by Bangerter filters (BF), affect gaze behaviour during multiple object tracking (MOT). METHODS: During the experiment, 22 volunteers completed the MOT task under three different visual conditions. The first condition involved natural binocular viewing, while the second and third conditions used 0.4 and 0.2 neutral density BF, respectively, resulting in monocular blur in the sensorially dominant eye. During the MOT task, participants were instructed to track three of eight balls for 10 s, and the speed was adjusted using a staircase procedure. Throughout the task, the following gaze parameters were recorded: fixation duration, saccade duration, amplitude and frequency as well as blink rate. RESULTS: During MOT execution, participants employed three gaze strategies regardless of viewing conditions: saccadic movements were predominant, followed by maintaining fixation on a central location throughout the trial and to a lesser extent, smooth pursuit eye movements. There was a significant effect of manipulating viewing conditions on the MOT scores (p = 0.046, η2 = 0.09). As the viewing conditions became more difficult, we observed a decrease in fixation duration (p = 0.004, η2 = 0.16) and blink rate (p < 0.001, η2 = 0.20) and an increase in saccadic amplitude (p < 0.001, η2 = 0.29). CONCLUSIONS: The results support the notion that perceptual-cognitive skills depend on the integrity of binocular vision, underscoring the sensitivity of gaze behaviours to any impairment of binocular function.


Assuntos
Transtornos da Visão , Visão Binocular , Humanos , Visão Monocular
4.
Optom Vis Sci ; 100(12): 847-854, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38019970

RESUMO

SIGNIFICANCE: Our results show significant diurnal variations in accommodative function and the magnitude of the phoria. Therefore, when comparing visual measures in clinical or laboratory settings, performing the visual examination at the same time of day (±1 hour) is encouraged. PURPOSE: The aim of this study was to evaluate the accommodation, binocular vergence, and pupil behavior on three different times during the day. METHODS: Twenty collegiate students (22.8 ± 2.1 years) participated in this study. Participants visited the laboratory on three different days at 2-hourly intervals (morning, 9:00 to 11:00 am ; afternoon, 2:00 to 4:00 pm ; evening, 7:00 to 9:00 pm ). The binocular vergence and accommodative function were measured using clinical optometric procedures, and the accommodative response and pupil function were evaluated in binocular conditions using the WAM-5500 autorefractometer. RESULTS: The accommodative amplitude for the right and left eyes showed statistically significant differences for the time interval ( P = .001 and P = .02, respectively), revealing higher accommodative amplitude in the morning and afternoon in comparison with the evening. Participants were more esophoric when assessed in the morning in comparison with the evening at far and near ( P = .02 and P = .01, respectively) and when assessed in the afternoon in comparison with the evening at far distance ( P = .02). The magnitude of accommodative response was higher in the morning, and it decreased throughout the day at 500 ( P < .001), 40 ( P = .05), and 20 cm ( P < .001). No statistically significant differences were obtained for any other variable. CONCLUSIONS: This study shows small diurnal variations in some accommodative and binocular vergence parameters, but no effects were observed for the pupil response. These outcomes are of special relevance for eye care specialists when performing repeated accommodative or binocular vergence measures. However, the diurnal variations were modest and may not influence a routine orthoptic examination.


Assuntos
Pupila , Estrabismo , Humanos , Convergência Ocular , Visão Binocular/fisiologia , Acomodação Ocular , Estrabismo/diagnóstico
5.
Ophthalmic Physiol Opt ; 43(4): 660-667, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37002939

RESUMO

PURPOSE: The ±2.00 D accommodative facility test presents several limitations, including the lack of objective information and inherent characteristics such as vergence/accommodative conflict, change in apparent size of the image, subjective criteria for judging blur and motor reaction time. By using free-space viewing conditions and an open-field autorefractor to monitor the refractive state, we examined the impact of manipulating these factors on the qualitative and quantitative assessment of accommodative facility. METHODS: Twenty-five healthy young adults (24.5 ± 4.5 years) took part in this study. Participants performed three accommodative facility tests (adapted flipper, 4D free-space viewing and 2.5D free-space viewing) under both monocular and binocular conditions in random order. A binocular open-field autorefractor was used to assess the accommodative response continuously, and these data were used to characterise accommodative facility quantitatively and qualitatively. RESULTS: There were statistically significant differences between the three testing methods both quantitatively (p < 0.001) and qualitatively (p = 0.02). For the same accommodative demand, a lower number of cycles was obtained for the adapted flipper condition in comparison with the 4D free-space viewing test (corrected p-value < 0.001, Cohen's d = 0.78). However, this comparison did not reach statistical significance for qualitative measures of accommodative facility (corrected p-value = 0.82, Cohen's d 0.05). CONCLUSIONS: These data provide evidence that the qualitative assessment of accommodative facility is not influenced by the inherent limitations of the ±2.00 D flipper test. The use of qualitative outcomes by incorporating an open-field autorefractor allows examiners to increase the validity of the accommodative facility test in both clinical and research settings.


Assuntos
Convergência Ocular , Visão Binocular , Adulto Jovem , Humanos , Visão Binocular/fisiologia , Acomodação Ocular , Testes Visuais , Refração Ocular
6.
Glob Chang Biol ; 29(9): 2536-2556, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36802091

RESUMO

The terrestrial water cycle links the soil and atmosphere moisture reservoirs through four fluxes: precipitation, evaporation, runoff, and atmospheric moisture convergence (net import of water vapor to balance runoff). Each of these processes is essential for sustaining human and ecosystem well-being. Predicting how the water cycle responds to changes in vegetation cover remains a challenge. Recently, changes in plant transpiration across the Amazon basin were shown to be associated disproportionately with changes in rainfall, suggesting that even small declines in transpiration (e.g., from deforestation) would lead to much larger declines in rainfall. Here, constraining these findings by the law of mass conservation, we show that in a sufficiently wet atmosphere, forest transpiration can control atmospheric moisture convergence such that increased transpiration enhances atmospheric moisture import and results in water yield. Conversely, in a sufficiently dry atmosphere increased transpiration reduces atmospheric moisture convergence and water yield. This previously unrecognized dichotomy can explain the otherwise mixed observations of how water yield responds to re-greening, as we illustrate with examples from China's Loess Plateau. Our analysis indicates that any additional precipitation recycling due to additional vegetation increases precipitation but decreases local water yield and steady-state runoff. Therefore, in the drier regions/periods and early stages of ecological restoration, the role of vegetation can be confined to precipitation recycling, while once a wetter stage is achieved, additional vegetation enhances atmospheric moisture convergence and water yield. Recent analyses indicate that the latter regime dominates the global response of the terrestrial water cycle to re-greening. Evaluating the transition between regimes, and recognizing the potential of vegetation for enhancing moisture convergence, are crucial for characterizing the consequences of deforestation as well as for motivating and guiding ecological restoration.


Assuntos
Ecossistema , Florestas , Humanos , Solo , Atmosfera , Transpiração Vegetal
7.
Clin Exp Optom ; 106(1): 20-28, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-34839788

RESUMO

Clinical Relevance Background: Steady-state accommodation is frequently evaluated with open-field autorefractors; however there is no consensus regarding the optimal test duration. Our results allow us to standardise the procedure followed for the assessment of the steady-state accommodative response in clinical and laboratory settings and may be of great relevance in time-constrained situations. BACKGROUND: The present study aims to determine the optimal recording time to assess the magnitude and variability of the accommodative response with a binocular open-field autorefractor. METHODS: The steady-state accommodative response of 84 healthy undergraduate students was dynamically measured using the Grand Seiko WAM-5500 autorefractor at 500 cm, 40 cm and 20 cm for 90 s while participants maintained focus on a stationary target. We examined the reliability and level of agreement between four time intervals (the first 10-s, 30-s, 60-s and 90-s) at three accommodative demands (0.2D, 2.5D and 5D). RESULTS: The magnitude of accommodation showed an excellent level of reliability (intraclass correlation coefficient [ICC]> 0.90) for the comparisons between the 90-s, 60-s and 30-s time intervals at the three viewing distances tested. However, when including the 10-s interval, there was a moderate reduction of the reliability indices and an increase of the mean difference between two time intervals (intra-class correlation [ICC] ranging from 0.89 to 0.97; and ESs ranging from 0.16 to 0.42). For the variability of accommodation, we observed an excellent reliability for the comparisons of the 90-s and 60-s measures at the three accommodative demands (ICC: 0.95-0.96), whereas for the rest of comparisons we observed from moderate to good levels of reliability. CONCLUSION: Our data indicate that of 30-s and 60-s are enough to accurately assess the magnitude and variability of the accommodative response with the WAM-5500 autorefractor, respectively.


Assuntos
Acomodação Ocular , Optometria , Humanos , Reprodutibilidade dos Testes , Estudantes
8.
Cont Lens Anterior Eye ; 46(1): 101526, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-34674953

RESUMO

OBJECTIVE: To assess the impact of using dual-focus soft contact lenses for myopia control on the dynamics of the accommodative response and facility. METHODS: 24 young adult myopes were fitted with dual-focus soft contact lenses for myopia control (MiSight®) and single-vision soft contact lenses (Proclear®). The WAM-5500 open-field autorefractor was used to measure the dynamics of the accommodative response (magnitude and variability) in binocular conditions, with accommodative data being gathered from the dominant eye, at three viewing distances (500 cm, 40 cm, and 20 cm) during 90 s. Also, the binocular accommodative facility was assessed with the WAM-5500 autorefractor. All participants performed the same experimental protocol with the dual-focus (MiSight) and single-vision (Proclear) soft contact lenses, with both experimental sessions being carried in two different days and following a counterbalanced order. RESULTS: This study showed greater lags of accommodation with the MiSight than the Proclear lenses at near distances (40 cm: 1.27 ± 0.77 vs. 0.68 ± 0.37 D, corrected p-value = 0.002, Cohen-d = 0.90; and 20 cm: 1.47 ± 0.84 vs. 1.01 ± 0.52 D, corrected p-value = 0.007, Cohen-d = 0.75), whereas a higher variability of accommodation was observed with the dual-focus than the single-vision lenses at 500 cm (0.53 ± 0.11 vs. 0.23 ± 0.10 D), 40 cm (0.82 ± 0.31 vs. 0.68 ± 0.37 D), and 20 cm (1.50 ± 0.56 vs. 1.15 ± 0.39 D) (corrected p-value < 0.001 in all cases, and Cohen-ds = 0.67-2.33). Also, a worse quantitative (27.75 ± 8.79 vs. 34.29 ± 10.08 cycles per minute, p = 0.029, Cohen-d = 0.48) and qualitative (23.68 ± 7.12 vs. 28.43 ± 7.97 score, p = 0.039, Cohen-d = 0.45) performance was observed with the MiSight when compared to the Proclear lenses. CONCLUSIONS: The use of dual-focus soft contact lenses for myopia control alters the dynamics of accommodative response and facility in the short-term. Although this optical design has demonstrated its effectiveness for myopia control, eye care specialists should be aware of the acute effects of these lenses on accommodation performance.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Optometria , Adulto Jovem , Humanos , Miopia/terapia , Acomodação Ocular , Óculos , Refração Ocular
9.
Clin Exp Optom ; 106(1): 85-90, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35057697

RESUMO

CLINICAL RELEVANCE: There is some controversy about the utility of prescribing blue-blocking filters to mitigate digital eye strain. We found that using commercially available blue-blocking filters was ineffective in reducing orbicularis oculi muscle activity and visual symptomatology during a 30-min reading task from a computer screen. BACKGROUND: There are some claims that blue-blocking (B-B) filters may be effective in reducing symptoms and signs of digital eye strain. However, recent studies have suggested that there is no sufficient evidence to support their use. This study assessed the short-term effects of a commercially available, B-B filter on orbicularis oculi (OO) muscle activity and symptoms of digital eye strain during the execution of a 30-min reading tas. METHODS: Twenty-three healthy young adults (22.9 ± 3.2 years of age) performed two reading tasks from a computer screen with or without a B-B filter on two different days. OO muscle activity was recorded by surface electromyography 4-5, 9-10, 14-15, 19-20, 24-25 and 29-30 min into the trial. Participants reported their perceived levels of visual discomfort and activation before and after completing the reading task. RESULTS: A Bayesian analysis favoured the null hypothesis that there was no change in OO muscle activity with or without using the B-B filter (Bayes Factor01 [BF01] = 7.08). Regarding symptomatology, the analysis favoured the time model that reading increased visual fatigue and discomfort but reduced activation levels (BF01 < 0.33 in all cases). However, our data did not support the alternative model that using B-B filter affected these visual symptoms. CONCLUSIONS: The B-B filter did not alter OO muscle activity or visual symptomatology significantly during the execution of a 30-min reading task in asymptomatic subjects. These findings support the idea that B-B filters do not attenuate signs and symptoms of digital eye strain.


Assuntos
Astenopia , Humanos , Adulto Jovem , Astenopia/diagnóstico , Teorema de Bayes , Computadores , Pálpebras , Transtornos da Visão
10.
Clin Exp Optom ; 106(3): 296-302, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35073496

RESUMO

CLINICAL RELEVANCE: Dual-focus soft contact lenses are effective in slowing myopia progression; however, their influence on near work-induced transient myopia (NITM) remains unknown. When performing a 5-min near task at 20 cm, we observed that dual-focus soft contact lens wear induced greater lags of accommodation and a lower initial NITM than single-vision soft contact lenses, which provides relevant information for better understanding the impact of using this optical design on the accommodative function. BACKGROUND: NITM has been proposed as a myogenic factor, although it is a matter of debate by the scientific community. The main objective of this study was to assess the short-term effect of wearing dual-focus soft contact lenses for myopia control on the steady-state accommodative response and NITM. METHODS: Twenty-four young myope adults wore, on two different days, dual-focus and single-vision soft contact lenses, while the accommodative response was dynamically measured with an open-field autorefractor during the execution of the NITM task. The shift and the time required to recover baseline levels in the refractive state after performing the 5-min near task (20 cm) were the main dependent variables. RESULTS: We found a lower magnitude of accommodation during the execution of the near task with the dual-focus in comparison to the single-vision soft contact lenses (p < 0.001). There was a lower initial NITM with the dual-focus when compared to the single-vision lenses (corrected p-value = 0.003, Cohen's d = 0.68), but no statistically significant differences were observed for decay duration (p = 0.984). CONCLUSIONS: Dual-focus soft contact lens wear causes a reduced accommodative response during a near task, and an initial small myopic shift at distance after a 5-min period of near viewing. The current findings may help to understand the mechanisms involved in myopia control with this optical strategy.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Adulto , Humanos , Refração Ocular , Lentes de Contato Hidrofílicas/efeitos adversos , Testes Visuais , Acomodação Ocular
11.
Rev. méd. (La Paz) ; 29(1): 52-58, 2023. Fig
Artigo em Espanhol | LILACS | ID: biblio-1450164

RESUMO

La encarcelación de genital masculino es considerada una urgencia urológica absoluta desafiante, la cual debe de ser tratada oportunamente así poder evitar lesiones irreversibles. El objetivo del presente artículo es exponer un caso de encarcelación de genital masculino por rodamiento diagnosticado y tratado en el Servicio de Urología del Hospital Obrero N°1 Tercer Nivel La Paz, Bolivia; en un paciente masculino de 80 años, que tras acudir al servicio de emergencias y realizar la revisión semiológica dirigida se llega al diagnóstico mencionado. En la literatura nacional, tras la revisión sistemática, no se encontró escritos sobre esta entidad siendo esta una manera de iniciar el levantamiento casuístico de esta variedad poco frecuente de patología urológica; a su vez, ampliar conocimientos no solo teórico - prácticos, sino medios diagnósticos y terapéutica clínico - quirúrgica experimental empleada basada en la evidencia; así evaluando los resultados mediatos, y repercusiones a largo plazo.


Male genital incarceration is considered an absolute challenging urological urgency, which must be treated in a timely manner to avoid irreversible injury. The objective of this article is to present a case of incarceration of male genital (penis) by bearing diagnosed and treated in the Urology Service of the Hospital Obrero No.1 Third Level La Paz, Bolivia; in an 80-year-old male patient, who after going to the emergency department and performing the targeted semiological review is reached at the aforementioned diagnosis. In the national literature, after the systematic review, no writings were found on this entity being this a way to initiate the casuistic uprising of this rare variety of urological pathology; in turn, expand not only theoretical knowledge - practical, but diagnostic and clinical therapeutic means - experimental surgical employed based on evidence; assessing mediated results, and long-term repercussions.

12.
Ophthalmic Physiol Opt ; 42(6): 1390-1398, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35959593

RESUMO

INTRODUCTION: There is scientific evidence that an individual's beliefs and/or expectations play a role in the behavioural and physiological response to a given treatment. This study aimed to assess whether the dynamics of the accommodative response and stereoacuity are sensitive to experimentally induced placebo and nocebo effects. METHODS: Nineteen healthy university students performed three experimental sessions (placebo, nocebo and control) in randomised order, with the dynamics of the accommodative response (magnitude and variability), stereoacuity and subjective measures being assessed in all sessions. For the experimental manipulation, participants ingested an inert capsule that was alleged to have positive (white capsule, placebo condition) or negative (yellow capsule, nocebo conditions) effects on the human physiology. In the control condition, participants did not ingest a capsule. RESULTS: The data revealed that the variability of accommodation was sensitive to experimentally induced placebo and nocebo effects, showing a more stable accommodative response for the placebo compared with the nocebo condition (corrected p-value = 0.04, Cohen's d = 0.60). In addition, better stereoacuity was found with the placebo, compared with the nocebo (corrected p-value = 0.01, Cohen's d = 0.69) and control (corrected p-value = 0.03, Cohen's d = 0.59) conditions. Successful experimental manipulation was confirmed by the analysis of subjective perceptions. CONCLUSIONS: These findings provide evidence that manipulating expectations about the efficacy of an inert treatment affect the dynamics of the accommodative response (variability of accommodation) and stereoacuity. The results have important applications in both clinical and research outcomes, where individuals´ beliefs/expectations could modulate the visual function.


Assuntos
Efeito Nocebo , Optometria , Acomodação Ocular , Humanos , Acuidade Visual
13.
Perception ; 51(8): 539-548, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35668637

RESUMO

We assessed the association between measures of dynamic visual acuity and a multiple object tracking task in physically active young adults. Ninety-four young adults performed the dynamic visual acuity and multiple object tracking tasks. Dynamic visual acuity was measured for horizontal and random walk motion paths at four target speeds (5, 10, 20, and 30°/s). For the multiple object tracking task, participants had to track three out of eight balls for 10 s, and the object speed was adjusted by a staircase procedure. We found that multiple object tracking performance was associated with better identification of horizontally and randomly moving targets in the dynamic visual acuity test (p < .001, r = -.35 [-.52, -.16]; and p < .001, r = -.52 [-.65, -.35]; respectively). This effect was consistent across all target speeds (all p-values<0.05). However, static visual acuity did not correlate with any measure of dynamic visual acuity or multiple object tracking (p > 0.170 in all cases). This study provides novel insights into the association between the ability to identify horizontally and randomly moving targets and track multiple objects. Future studies are needed to determine the potential utility of dynamic visual acuity for talent identification and predicting sports performance in real-game situations.


Assuntos
Percepção de Movimento , Humanos , Movimento (Física) , Acuidade Visual , Adulto Jovem
14.
Restor Ecol ; : e13646, 2022 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-35603134

RESUMO

Coral restoration initiatives are gaining significant momentum in a global effort to enhance the recovery of degraded coral reefs. However, the implementation and upkeep of coral nurseries are particularly demanding, so that unforeseen breaks in maintenance operations might jeopardize well-established projects. In the last 2 years, the COVID-19 pandemic has resulted in a temporary yet prolonged abandonment of several coral gardening infrastructures worldwide, including remote localities. Here we provide a first assessment of the potential impacts of monitoring and maintenance breakdown in a suite of coral restoration projects (based on floating rope nurseries) in Colombia, Seychelles, and Maldives. Our study comprises nine nurseries from six locations, hosting a total of 3,554 fragments belonging to three coral genera, that were left unsupervised for a period spanning from 29 to 61 weeks. Floating nursery structures experienced various levels of damage, and total fragment survival spanned from 40 to 95% among projects, with Pocillopora showing the highest survival rate in all locations present. Overall, our study shows that, under certain conditions, abandoned coral nurseries can remain functional for several months without suffering critical failure from biofouling and hydrodynamism. Still, even where gardening infrastructures were only marginally affected, the unavoidable interruptions in data collection have slowed down ongoing project progress, diminishing previous investments and reducing future funding opportunities. These results highlight the need to increase the resilience and self-sufficiency of coral restoration projects, so that the next global lockdown will not further shrink the increasing efforts to prevent coral reefs from disappearing.

15.
Int Ophthalmol ; 42(9): 2773-2784, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35378638

RESUMO

PURPOSE: This study aimed to assess the impact of wearing swimming goggles (SG) on corneal biomechanics. METHODS: Corneal deformation response, central corneal thickness (CCT), intraocular pressure (IOP) and biomechanically corrected intraocular pressure (bIOP) were measured with the Corvis system (Oculus Optikgeräte GmbH, Wetzlar, Germany) in thirty-one healthy young adults while wearing a drilled SG. All measurements were obtained before, at 30 s, 2 min, 3.5 min and 5 min of wearing SG, just after SG removal and after 2 min of SG removal. RESULTS: The corneal biomechanics is sensitive to SG wear, observing lower corneal deformability during SG use. Specifically, wearing SG caused an increase in the time and length of the first applanation and radius curvature at the highest concavity, as well as a decrease and in the velocity of the first applanation and time and deformation amplitude of the second applanation (p < 0.001 in all cases). After SG removal, corneal biomechanical parameters showed a rebound-effect, obtaining a higher corneal deformability in comparison with baseline reading (p-corrected < 0.05 in all cases). Additionally, IOP and bIOP significantly increased while wearing SG (p < 0.001 in both cases), whereas CCT remained stable (p = 0.850). CONCLUSIONS: Wearing SG modifies the biomechanical properties of the cornea, with reduced corneal deformability during SG wear. The outcomes of this study should be taken into consideration when making clinical decisions in subjects at high risk of developing corneal ectasias or glaucoma, as well as in the post-surgical management of these ocular conditions.


Assuntos
Dispositivos de Proteção dos Olhos , Natação , Fenômenos Biomecânicos , Córnea , Paquimetria Corneana , Humanos , Pressão Intraocular , Tonometria Ocular , Adulto Jovem
16.
Indian J Ophthalmol ; 70(4): 1222-1228, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35326020

RESUMO

Purpose: We aimed to assess the impact of drinking water (500 and 1000 mL) on corneal biomechanics and determine the level of association between changes in intraocular pressure and variations in the different biomechanical properties of the cornea. Methods: A total of 39 healthy young adults ingested either 1000 mL (n = 21) or 500 mL (n = 18) of tap water in 5 min. The CorVis ST system was used to assess corneal biomechanics at baseline and at 15, 30, and 45 min after water ingestion. Results: Water drinking induced statistically significant changes in the deformation amplitude (P < 0.001, η2 = 0.166), highest concavity time (P = 0.012, η2 = 0.093), peak distance (P < 0.001, η2 = 0.171), time and velocity of the first applanation (P < 0.001, η2 = 0.288 and P = 0.016, η2 = 0.087, respectively), and time and velocity of the second applanation (P = 0.030, η2 = 0.074 and P = 0.001, η2 = 0.132, respectively), being independent of the amount of water ingested (P > 0.05 in all cases). There were significant associations between changes in intraocular pressure and some parameters of corneal biomechanics. Conclusion: Small variations in whole-body hydration status alter different biomechanical properties of the cornea, with these changes being associated with intraocular pressure levels. These findings indicate that whole-body hydration status can be considered for the diagnosis and management of different ocular conditions.


Assuntos
Oftalmopatias , Pressão Intraocular , Fenômenos Biomecânicos , Córnea , Humanos , Tonometria Ocular , Água , Adulto Jovem
17.
PeerJ ; 10: e13160, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35341047

RESUMO

Objectives: The execution of isometric resistance training has demonstrated to cause changes in the ocular physiology. The morphology of the cornea and anterior chamber is of paramount importance in the prevention and management of several ocular diseases, and thus, understating the impact of performing isometric exercise on the eye physiology may allow a better management of these ocular conditions. We aimed to determine the short-term effects of 2-minutes upper-body isometric effort at two different intensities on corneal and anterior eye morphology. Methods: Eighteen healthy young adults performed a 2-minutes isometric biceps-curl exercise against two loads relative to their maximum strength capacity (high-intensity and low-intensity) in a randomized manner. An Oculus Pentacam was used to measure the corneal morphology and anterior chamber parameters in both experimental conditions at baseline, during the isometric effort (after 30, 60, 90 and 120 seconds), and after 30 and 120 seconds of passive recovery. Results: We found that isometric effort causes an increase in pupil size (P < 0.001), and a decrease in the iridocorneal angle (P = 0.005), anterior chamber volume (P < 0.001) and K-flat (P < 0.001) during isometric effort, with these effects being more accentuated in high-intensity condition (P < 0.005 in all cases).Performing 2-minutes upper-body isometric effort did not alter anterior chamber depth, central corneal thickness, corneal volume, and K-steep (P > 0.05 in all cases). Conclusions: Our data exhibit that performing 2-minutes of upper-body isometric exercise modifies several parameters of the corneal morphology and anterior eye biometrics, with these changes being greater for the high-intensity exercise condition. The findings of this study may be of relevance for the prevention and management of corneal ectasias and glaucoma.


Assuntos
Doenças da Córnea , Glaucoma , Adulto Jovem , Humanos , Córnea , Câmara Anterior/fisiologia
18.
Ophthalmic Physiol Opt ; 42(4): 753-761, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35305040

RESUMO

INTRODUCTION: Dual-focus soft contact lenses for myopia management have demonstrated to be an effective strategy to reduce myopia progression. However, this optical design has been shown to alter visual quality and accommodative function. The aim of this study was to examine the accommodative and behavioural performance during the execution of a psychomotor vigilance task (PVT) while wearing dual-focus and single-vision soft contact lenses. METHODS: The steady-state accommodative response was recorded with the WAM-5500 binocular open-field autorefractor during the execution of a 10-min PVT at 50 cm either with the dual-focus (MiSight 1-day) or single-vision (Proclear 1-day) soft contact lenses, using a sample of 23 healthy young adults. Each experimental session was performed on two different days in a counterbalanced order. RESULTS: A greater lag of accommodation, variability of accommodation and reaction time was found while wearing dual-focus in comparison with single-vision soft contact lenses (mean differences during the 10-min PVT were 0.58 ± 0.81 D, p < 0.001; 0.31 ± 0.17 D, p < 0.001 and 15.22 ± 20.93 ms, p = 0.002, respectively). Also, a time-on-task effect was found for the variability of accommodation and reaction time (p = 0.001 and p < 0.001, respectively), observing higher values over time. However, the lag of accommodation did not change significantly as a function of time-on-task (p = 0.33). CONCLUSION: Dual-focus soft contact lens wear influences the steady-state accommodative response and behavioural performance during the execution of a visual vigilance task in the short-term. Eye care practitioners should be aware of these effects when prescribing these lenses for myopia management, and provide specific recommendations according to the individual visual needs.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Acomodação Ocular , Óculos , Humanos , Miopia/terapia , Refração Ocular , Adulto Jovem
19.
Curr Eye Res ; 47(1): 62-68, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34612106

RESUMO

PURPOSE: Recent technological advances have permitted to objectively record the accommodative response while shifting between two different levels of accommodation. This study is aimed at examining the concurrent validity of a new objective method for the qualitative and quantitative assessment of binocular accommodative facility, which is named 2Q-AF test, in comparison to the ±2.00 DS lens flippers. METHODS: Fifty-six individuals took part in this study (36 healthy young adults [24.4 ± 3.2 years] and 20 children [12.2 ± 0.4 years]). Participants randomly performed the 2Q-AF and the ±2.00 DS lens flipper tests. For the 2Q-AF test, a binocular open-field autorefractor was used to record the magnitude of accommodative response during a 60-sec period, while participants repeatedly changed fixation from a 5 m to a 40 cm chart when clarity of vision was achieved at each level. Due to the advantages of the proposed method, we have determined the number of cycles and the 2Q-AF score, with the latter also considering the accuracy of changes in accommodation. A standard procedure was followed for the ±2.00 DS flipper test. RESULTS: Our data exhibited a moderate association between the number of cycles with the ±2.00 DS lens flippers and the number of cycles in the 2Q-AF test in the group of young adults (p = .005, r = 0.46 [0.15-0.68]) and children (p = .007, r = 0.58 [0.19-0.81]), whereas a stronger relationship was observed when considering the number of cycles with the ±2.00 DS lens flippers and the 2Q-AF score (young adults: p < .001, r = 0.83 [0.69-0.91]; and children: p < .001, r = 0.78 [0.52-0.91]). CONCLUSIONS: The current findings show that the 2Q-AF test is a valid method for accommodative facility assessment, as suggested by its good levels of reliability and validity. This method allows to examine the accommodative facility in qualitative terms and solve most of the limitations associated with the ±2.00 DS lens flipper test.


Assuntos
Acomodação Ocular/fisiologia , Cristalino/fisiopatologia , Miopia/cirurgia , Visão Binocular/fisiologia , Adolescente , Adulto , Criança , Feminino , Humanos , Cristalino/cirurgia , Masculino , Miopia/fisiopatologia , Reprodutibilidade dos Testes , Testes Visuais , Adulto Jovem
20.
J Optom ; 15(2): 154-159, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33478924

RESUMO

PURPOSE: The use of swimming goggles (SG) has demonstrated to alter different ocular parameters, however, the impact of wearing SG on the tear film stability remain unknown. The main objective of this study was to determine the short-term effects of wearing SG on tear film surface quality break-up time (TFSQ-BUT). METHODS: Twenty-eight young healthy adults (14 men and 14 women) wore a drilled SG, and TFSQ-BUT was measured before, during and after SG use. Dynamic-area high-speed videokeratoscopy was used for the non-invasive assessment of TFSQ-BUT. RESULTS: TFSQ-BUT was significantly reduced while SG wear in comparison to the baseline measurement (4.8 ±â€¯4.5 s vs. 8.8 ±â€¯6.9 s; corrected p-value = 0.017, d = 0.57, mean difference = 4.0 [0.6, 7.3]; 45% reduction). Immediately after SG removal, TFSQ-BUT rapidly recovered baseline levels (8.2 ±â€¯5.9 s vs. 8.8 ±â€¯6.9 s; corrected p-value = 0.744). The impact of wearing SG on TFSQ-BUT were independent of the gender of the participants (p = 0.934). CONCLUSION: The use of SG induces a TFSQ-BUT reduction, with these changes returning to baseline levels immediately after SG removal. These data may be of relevance for the management of dry eye patients, who need to avoid circumstances that exacerbate tear film instability. Nevertheless, these results must be interpreted with caution since the experiment did not entirely mimic real-life conditions (e.g., eye cup piece drilled, time of exposure, environmental conditions). Future studies should consider the inclusion of dry eye patients and older individual in order to explore the generalizability of these findings.


Assuntos
Síndromes do Olho Seco , Dispositivos de Proteção dos Olhos , Adulto , Síndromes do Olho Seco/etiologia , Feminino , Humanos , Masculino , Natação , Lágrimas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA