Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
3.
Ultrasound Obstet Gynecol ; 56(6): 921-927, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-31975450

RESUMO

OBJECTIVES: To evaluate the association between pelvic floor dimensions in nulliparous women at term and fetal head engagement, as assessed by transperineal ultrasound. METHODS: This was a prospective observational study of nulliparous women at term. Before the onset of labor, transperineal ultrasound was used to measure the anteroposterior diameter (APD) of the levator hiatus and the angle of progression (AoP) at rest, on maximum pelvic floor muscle contraction and on maximum Valsalva maneuver (before and after visual feedback). We assessed the correlation between pelvic floor static and dynamic dimensions (levator hiatal APD and levator ani muscle coactivation) and AoP, which is an objective index of fetal head engagement. RESULTS: In total, 282 women were included in the analysis. Among these, 211 (74.8%) women had a vaginal delivery while 71 (25.2%) had a Cesarean delivery. AoP was narrower in the Cesarean-delivery group at rest, on maximum pelvic floor muscle contraction and on maximum Valsalva, whereas no differences in levator hiatal APD were found between the two groups. We found a negative correlation between levator hiatal APD at rest, on maximum pelvic floor muscle contraction and on maximum Valsalva and the duration of the second stage of labor. There was a positive correlation between AoP and levator hiatal APD on maximum Valsalva maneuver after visual feedback (r = 0.15, P = 0.01). Women with levator ani muscle contraction on Valsalva maneuver (i.e. coactivation), both pre and post visual feedback, had a narrower AoP at rest and on maximum Valsalva. After visual feedback, women with levator ani muscle coactivation had a longer second stage of labor than did those without (80.8 ± 61.4 min vs 62.9 ± 43.4 min (P = 0.04)). CONCLUSIONS: Smaller pelvic floor dimensions and levator ani muscle coactivation are associated with higher fetal head station and with a longer second stage of labor in nulliparous women at term. Copyright © 2020 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Feto/diagnóstico por imagem , Cabeça/embriologia , Trabalho de Parto/fisiologia , Diafragma da Pelve/fisiologia , Ultrassonografia Pré-Natal/métodos , Adulto , Cesárea/estatística & dados numéricos , Parto Obstétrico/estatística & dados numéricos , Feminino , Humanos , Segunda Fase do Trabalho de Parto/fisiologia , Contração Muscular/fisiologia , Paridade , Diafragma da Pelve/diagnóstico por imagem , Períneo/diagnóstico por imagem , Gravidez , Estudos Prospectivos , Manobra de Valsalva/fisiologia , Adulto Jovem
4.
Ultrasound Obstet Gynecol ; 53(1): 95-100, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29749657

RESUMO

OBJECTIVE: To investigate the association between application of fundal pressure during the second stage of labor (Kristeller maneuver) and the risk of levator ani muscle (LAM) injury. METHODS: This was a prospective case-control study of women recruited immediately after their first vaginal delivery in our university hospital between March 2014 and September 2016. Women who underwent the Kristeller maneuver were recruited as cases. For each case, a control (no Kristeller) was recruited matched for body mass index, use of epidural analgesia, duration of second stage of labor and birth weight. All women were invited to undergo four-dimensional (4D) transperineal ultrasound (TPU) 3-6 months postpartum. The main outcome measure was the presence of LAM avulsion on 4D-TPU. TPU results were compared between cases and controls. Multivariate logistic regression analysis was performed to identify independent risk factors for LAM avulsion. RESULTS: During the study period, 134 women in the Kristeller maneuver group and 128 women in the control group underwent TPU assessment. Women who underwent the Kristeller maneuver had a higher prevalence of LAM avulsion than did controls (38/134 (28.4%) vs 18/128 (14.1%); P = 0.005). In addition, women in the Kristeller-maneuver group had a larger hiatal area on maximum Valsalva maneuver and a greater increase in hiatal area from rest to maximum Valsalva. On multivariate logistic regression analysis, use of the Kristeller maneuver was the only independent factor associated with LAM avulsion (odds ratio, 2.5 (95% CI, 1.29-4.51)). CONCLUSION: The Kristeller maneuver is associated with an increased risk of LAM avulsion when applied in women during their first vaginal delivery. This should be taken into account when deciding to use fundal pressure to accelerate the second stage of labor and when counseling women following childbirth. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Canal Anal/lesões , Segunda Fase do Trabalho de Parto , Distúrbios do Assoalho Pélvico/epidemiologia , Pressão/efeitos adversos , Adulto , Canal Anal/diagnóstico por imagem , Estudos de Casos e Controles , Parto Obstétrico/métodos , Feminino , Humanos , Itália/epidemiologia , Complicações do Trabalho de Parto/epidemiologia , Complicações do Trabalho de Parto/etiologia , Distúrbios do Assoalho Pélvico/etiologia , Gravidez , Resultado da Gravidez , Estudos Prospectivos , Fatores de Risco
5.
Ultrasound Obstet Gynecol ; 53(5): 686-692, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30353589

RESUMO

OBJECTIVE: To assess the effect of levator ani muscle (LAM) coactivation at term on outcome of labor in nulliparous women. METHODS: This was a prospective study of 284 low-risk nulliparous women with a singleton pregnancy at term recruited before the onset of labor. The anteroposterior diameter of the levator hiatus was measured in each woman on transperineal ultrasound at rest, on maximum pelvic floor muscle contraction and on maximum Valsalva maneuver before and after visual feedback. LAM coactivation was defined as a reduction in the anteroposterior diameter of the levator hiatus on maximum Valsalva maneuver in comparison with that at rest. The association of pelvic hiatal diameter values and LAM coactivation with mode of delivery and duration of labor was assessed. RESULTS: No significant difference was found between women who underwent Cesarean delivery and those who had a vaginal delivery with regard to the anteroposterior diameter of the levator hiatus at rest, on pelvic floor muscle contraction and on Valsalva maneuver. Longer second stage of labor was associated with shorter anteroposterior diameter of the levator hiatus on all assessments, but in particular at rest and on Valsalva both before and after visual feedback. LAM coactivation was found in 89 (31.3%) and 75 (26.4%) women before and after visual feedback, respectively. Post visual feedback, women with LAM coactivation had a significantly longer second stage of labor than did those without LAM coactivation (83 ± 63 vs 63 ± 42 min; P = 0.006). On Cox regression analysis, LAM coactivation post visual feedback was an independent predictor of longer second stage of labor (adjusted hazard ratio, 1.499 (95% CI, 1.076-2.087); P = 0.017). CONCLUSION: LAM coactivation in nulliparous women at term is associated with a longer second stage of labor. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Segunda Fase do Trabalho de Parto/fisiologia , Contração Muscular/fisiologia , Músculo Esquelético/fisiopatologia , Diafragma da Pelve/fisiopatologia , Manobra de Valsalva/fisiologia , Adulto , Parto Obstétrico/métodos , Parto Obstétrico/estatística & dados numéricos , Feminino , Humanos , Músculo Esquelético/diagnóstico por imagem , Complicações do Trabalho de Parto/etiologia , Complicações do Trabalho de Parto/fisiopatologia , Paridade , Diafragma da Pelve/diagnóstico por imagem , Gravidez , Modelos de Riscos Proporcionais , Estudos Prospectivos , Análise de Regressão , Nascimento a Termo/fisiologia , Fatores de Tempo , Ultrassonografia Pré-Natal/métodos , Adulto Jovem
6.
Ultrasound Obstet Gynecol ; 50(3): 388-394, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27642724

RESUMO

OBJECTIVES: Caudal distension of the female pelvic floor is common and results in perineal descent and a caudally curved levator hiatus (warping). Image reconstruction of the pelvic floor using currently available ultrasound techniques involves a linear approach (flat-plane reconstruction). We aimed to evaluate the feasibility, reproducibility and potential usefulness of a new three-dimensional (3D) technique capable of reconstructing a curved plane of the levator hiatus. METHODS: Primiparous women were recruited to undergo a 3D/four-dimensional transperineal ultrasound examination 3-6 months after delivery. Levator ani muscle warping was evaluated on Valsalva maneuver by measuring the distance between the plane extending from the pubic rami to the anorectal angle and the plane of minimal hiatal dimensions on the coronal plane. Warping distance was used to reconstruct a curved plane of the levator hiatus using the curved OmniView volume contrast imaging (VCI) technique (C-OV). Intra- and interobserver reproducibility of the C-OV technique were assessed, as was intermethod agreement between the C-OV technique and the linear OmniView-VCI (L-OV) technique, for the measurement of levator hiatal area on Valsalva maneuver. RESULTS: Measurement of the levator hiatal area using C-OV was feasible in all 84 women recruited. The warping distance ranged from -3.5 to 9.7 mm, confirming that the 1-2-cm slice thickness traditionally used for linear reconstruction was adequate for proper assessment of levator hiatal area in our population. C-OV showed excellent intra- and interobserver reproducibility, as well as excellent agreement with the L-OV technique for measuring levator hiatal area. No systematic difference was demonstrated in any of the reproducibility studies performed. CONCLUSIONS: 3D reconstruction of the warped levator hiatal plane is feasible and highly reproducible. In our population, reconstruction of a curved plane to correct for levator hiatal warping did not offer any benefit over the traditionally performed linear reconstruction. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Diafragma da Pelve/diagnóstico por imagem , Prolapso de Órgão Pélvico/diagnóstico por imagem , Ultrassonografia Pré-Natal , Adulto , Feminino , Humanos , Imageamento Tridimensional , Paridade , Prolapso de Órgão Pélvico/fisiopatologia , Valor Preditivo dos Testes , Gravidez , Estudos Prospectivos , Manobra de Valsalva
7.
Ultrasound Obstet Gynecol ; 47(5): 629-35, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26105710

RESUMO

OBJECTIVE: To assess the reproducibility of a new technique for three-/four-dimensional (3D/4D) ultrasound imaging of the pelvic floor: OmniView™ volume contrast imaging (VCI) for measurement of the pelvic hiatal area on maximum contraction and Valsalva maneuver. In addition, we aimed to study the intermethod agreement between the new technique and the 3D/4D render method. METHODS: We acquired one static 3D and two dynamic 4D transperineal volumes (one obtained during contraction and one during Valsalva maneuver) from 35 nulliparous asymptomatic healthy volunteers and 35 women with symptoms of pelvic floor dysfunction. Each 3D dataset was analyzed using the OmniView-VCI technique to measure the pelvic hiatal area at rest, on maximum contraction and on maximum Valsalva. Analysis was performed twice by the same operator and once by another operator in order to assess intra- and interobserver reproducibility. All measurements were repeated by one operator using the 3D/4D render method to evaluate the intermethod agreement. Reproducibility and intermethod agreement were studied by means of intraclass correlation coefficients (ICC) and the Bland-Altman method. RESULTS: Measurement of hiatal area using the OmniView-VCI technique showed excellent intraobserver and interobserver reproducibility in both asymptomatic and symptomatic women at rest, on contraction and on Valsalva maneuver. In addition, excellent agreement was demonstrated between OmniView-VCI and 3D/4D render in both groups (ICCs on Valsalva in asymptomatic and symptomatic women were 0.894 and 0.975, respectively). No systematic difference was noted in any of the reliability studies performed. CONCLUSIONS: OmniView-VCI is a reliable method for pelvic hiatal area measurement. Both rendering mode and OmniView-VCI can be used interchangeably for assessing pelvic hiatal area. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Imageamento Tridimensional/instrumentação , Diafragma da Pelve/diagnóstico por imagem , Ultrassonografia/instrumentação , Feminino , Humanos , Imageamento Tridimensional/métodos , Variações Dependentes do Observador , Gravidez , Reprodutibilidade dos Testes , Ultrassonografia/métodos
8.
Ultrasound Obstet Gynecol ; 44(1): 82-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24496823

RESUMO

OBJECTIVES: The objectives of this study were firstly to assess the longitudinal changes of various sonographic parameters of fetal head progression in relation to length of active second stage of labor, and secondly to compare ultrasound findings obtained longitudinally among fetuses with persistent occiput posterior (OP) vs those with persistent occiput anterior (OA) position. METHODS: From a series of nulliparous low-risk women at term attending the labor ward of our university hospital, transperineal ultrasound volumes were prospectively acquired at the beginning of the active second stage (T1) and at 40-min intervals thereafter until delivery (T2, T3). Sonographic parameters were derived from offline analysis of each volume, including the angle of progression (AoP), progression distance (PD), head-symphysis distance (HSD), head direction (HD) and midline angle. These parameters were compared between patients who delivered within 60 min from the beginning of the active second stage of labor (early delivery) and those who remained undelivered by that time (late delivery). Fetal head position was determined from stored digital images of transabdominal examinations performed at the beginning of the active second stage. Comparison was performed between fetuses with OA and those with persistent OP position at delivery. RESULTS: Spontaneous vaginal delivery was achieved in 58 (81.7%) cases, whereas vacuum extraction and Cesarean section were performed in eight (11.3%) and five (7.0%) cases, respectively. Delivery was achieved within 60 min from the beginning of the active second stage in 44 (62.0%) patients. In the early vs late delivery groups, measurements of AoP, HSD and PD at T1 were significantly different (AoP, 143.9 ± 20.5° vs 125.3 ± 15.0°, P < 0.001; HSD, 14.8 ± 4.5 mm vs 20.9 ± 5.8 mm, P < 0.001; PD, 44.0 ± 14.1 vs 35.0 ± 13.1 mm, P = 0.008). On logistic regression analysis of data obtained at T1, maternal body mass index, oxytocin administration, neonatal birth weight and HSD appeared to predict independently duration of the active second stage. Among fetuses delivering in the OP position (n = 10, 13.5%), Cesarean delivery was significantly more common than in those delivering in the OA position (n = 5 (50.0%) vs n = 2 (3.1%), P = 0.001). Women with persistent OP position compared with OA showed a significantly different AoP at T1 (122 ± 17° vs 138 ± 20°, P = 0.016), HD and HSD at T1 (HD, 112 ± 17 mm vs 86 ± 19 mm, P < 0.001; HSD, 16.5 ± 5.4 mm vs 22.8 ± 6.6 mm, P = 0.008) and at T2 (HD, 120 ± 16 vs 82 ± 27 mm, P = 0.008; HSD, 12.6 ± 3.4 mm vs 18.5 ± 5.4 mm, P = 0.038). CONCLUSIONS: AoP, PD and HSD are significantly different between patients undergoing delivery before or after 60 min from the beginning of the active second stage of labor. Ultrasound parameters are among the significant predictors of duration of the active second stage. Moreover, in fetuses persisting in the OP position vs those delivering in the OA position, fetal head progression seems to differ at early phases of the active second stage.


Assuntos
Cabeça/diagnóstico por imagem , Apresentação no Trabalho de Parto , Segunda Fase do Trabalho de Parto/fisiologia , Ultrassonografia Pré-Natal , Adulto , Cesárea/estatística & dados numéricos , Feminino , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Gravidez , Estudos Prospectivos , Fatores de Tempo , Ultrassonografia Pré-Natal/métodos , Vácuo-Extração/estatística & dados numéricos
9.
Ultrasound Obstet Gynecol ; 43(2): 183-8, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24006290

RESUMO

OBJECTIVES: To assess the intermethod agreement between two-dimensional (2D) and three-dimensional (3D) transperineal ultrasound methods in measuring a new index of fetal head station (the fetal head-symphysis distance (HSD)) in active labor, and to assess potential factors that may affect their agreement. METHODS: HSD was measured by transperineal ultrasound in 86 women in active labor, once using a 2D and once using a 3D technique. 2D images were acquired first in 43 cases and 3D images were acquired first in the other 43 women. Intermethod agreement between 2D and 3D methods was analyzed by means of intraclass correlation coefficient (ICC) and Bland-Altman analysis. In addition, potential factors affecting the intermethod reproducibility were investigated including fetal occiput position, order of acquisition, fetal head station, stage of labor, maternal body mass index and use of epidural analgesia, using the ANOVA test to check for systematic bias and Levene's test for homoscedasticity. RESULTS: Good agreement was demonstrated between 2D and 3D measurements of HSD (ICC, 0.949 (95% CI, 0.914-0.984)). No evidence of systematic difference was shown between the two methods (average difference ± SD = 0.03 ± 2.29 mm; P = 0.888). The only factor that had a significant effect on systematic difference between 2D and 3D methods was order of acquisition (P = 0.042); the first observation was higher regardless of the method used. Fetal head station had a significant effect on the homogeneity between the two methods (P = 0.004) with a better 2D-3D agreement obtained at lower head stations (SD of differences: 1.63 vs 2.59 mm). CONCLUSIONS: There is very good agreement between 2D and 3D methods of assessing HSD. Agreement is better in lower fetal head stations.


Assuntos
Cabeça/diagnóstico por imagem , Trabalho de Parto/fisiologia , Períneo/diagnóstico por imagem , Sínfise Pubiana/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Adulto , Feminino , Humanos , Imageamento Tridimensional , Apresentação no Trabalho de Parto , Pessoa de Meia-Idade , Gravidez , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA