Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Int J Cardiol ; 417: 132569, 2024 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-39303924

RESUMO

BACKGROUND: Raphe-type bicuspid aortic valve (BAV) is a potential hostile scenario in trans-catheter aortic valve replacement (TAVR) due to pronounced calcium burden, possibly associated with tapered valve configuration. Trans-Catheter heart valve (THV) sizing strategy (annular vs. supra-annular) is controversial in this valve subtype. OBJECTIVES: To describe the phenotypical characteristics of severe, tapered, raphe-type, BAV stenosis undergoing TAVR and to explore safety and efficacy of modern-generation THVs, analysing the impact of annular and supra-annular sizing strategies on short- and mid-terms outcomes. METHODS: This is a retrospective, multicenter registry enrolling consecutive stenotic Sievers type 1 BAV treated with TAVR. Study population was divided into tapered and non-tapered configuration according to MSCT analysis. Matched comparison between annular and supra-annular sizing groups was performed in tapered population. RESULTS: From January 2016 to June 2023, 897 patients were enrolled. Of them, 696 patients displayed a tapered configuration. Of those, 510 received a THV according to annular sizing. After propensity score matching 186 matched pairs were selected. Technical success (96.2 % vs 94.1 %, OR 1.61 [0.61-4.24], p = 0.34), 30-day device success (83.6 % in both groups, OR 1.42 [0.78-2.57], p = 0.25) and 30-day early safety (71.8 % vs 70.5 %, OR 1.07 [0.68-1.68], p = 0.78) were similar between the annular and supra-annular sizing groups; a higher post-TAVR gradient was observed in supra-annular group, although it was only 2 mmHg mean. At mid-term follow-up, the rate of clinical efficacy was 84.7 %. CONCLUSIONS: TAVR with modern-generation devices is safe and effective for tapered raphe-type BAV, showing comparable results for annular and supra-annular sizing strategies.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Idoso , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Idoso de 80 Anos ou mais , Resultado do Tratamento , Desenho de Prótese , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Seguimentos
2.
Cardiovasc Res ; 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39189611

RESUMO

BACKGROUND: Low-dose colchicine reduces the risk of cardiovascular events after myocardial infarction (MI). The purpose of this study was to assess the effect of colchicine post-MI on coronary plaque morphology in non-culprit segments by optical coherence tomography (OCT). METHODS AND RESULTS: COCOMO-ACS was a double-blind, placebo-controlled trial that randomized 64 patients (median age 61.5 years; 9.4% female) with acute non-ST-segment elevation MI to colchicine 0.5 mg daily or placebo for a median of 17.8 months in addition to guideline-recommended therapy. Participants underwent serial OCT imaging within a matched segment of non-culprit coronary artery which contained at least one lipid-rich plaque causing ≥20% stenosis. The primary outcome was the change in minimum fibrous cap thickness (FCT) in non-culprit segments from baseline to final visit. Of those randomized, 57 (29 placebo, 28 colchicine) had evaluable imaging at baseline and follow-up. Overall, colchicine had no effect on relative (placebo +48.0±35.1% vs. colchicine +62.4±38.1%, P=0.18) or absolute changes in minimum FCT (+29.2±20.9 µm vs. +37.2±21.3 µm, P=0.18), or change in maximum lipid arc (-38.8±32.2° vs. -54.8±46.9°, P=0.18) throughout the imaged non-culprit segment. However, in patients assigned colchicine, cap rupture was less frequent (placebo 27.6% vs. colchicine 3.6%, P=0.03). In post-hoc analysis of 43 participants who had been followed for at least 16 months, minimum FCT increased to a greater extent in the colchicine group (placebo +38.7±25.4% vs. colchicine +64.7±34.1%, P=0.005). CONCLUSION: In this study, OCT failed to detect an effect of colchicine on the minimum FCT or maximum lipid arc of plaques in non-culprit segments post-MI. The post-hoc observation that minimum FCT increased to a greater extent with colchicine after more prolonged treatment suggests longer-term studies may be required to detect the effect of anti-inflammatory therapies on plaque morphology by OCT. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry Identifier, ACTRN12618000809235, registered on the 11th of May 2018.

3.
Int J Cardiol Heart Vasc ; 52: 101417, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38725440

RESUMO

Background: Although the clinical factors associated with progression of coronary artery disease have been well studied, the angiographic predictors are less defined. Objectives: Our objective was to study the clinical and angiographic factors that associate with progression of coronary artery stenoses. Methods: We conducted a retrospective analysis of consecutive patients undergoing multiple, clinically indicated invasive coronary angiograms with an interval greater than 6 months, between January 2013 and December 2016. Lesion segments were analysed using Quantitative Coronary Angiography (QCA) if a stenosis ≥ 20 % was identified on either angiogram. Stenosis progression was defined as an increase ≥ 10 % in stenosis severity, with progressor groups analysed on both patient and lesion levels. Mixed-effects regression analyses were performed to evaluate factors associated with progression of individual stenoses. Results: 199 patients were included with 881 lesions analysed. 108 (54.3 %) patients and 186 (21.1 %) stenoses were classified as progressors. The median age was 65 years (IQR 56-73) and the median interval between angiograms was 2.1 years (IQR 1.2-3.0). On a patient level, age, number of lesions and presence of multivessel disease at baseline were each associated with progressor status. On a lesion level, presence of a stenosis downstream (OR 3.07, 95 % CI 2.04-4.63, p < 0.001) and circumflex artery stenosis location (OR 1.81, 95 % CI 1.21-2.7, p = 0.004) were associated with progressor status. Other lesion characteristics did not significantly impact progressor status or change in stenosis severity. Conclusion: Coronary lesions which have a downstream stenosis may be at increased risk of stenosis progression. Further research into the mechanistic basis of this finding is required, along with its implications for plaque vulnerability and clinical outcomes.

4.
Catheter Cardiovasc Interv ; 104(1): 115-124, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38764320

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat severe aortic stenosis in younger patients. Accordingly, lifetime management regarding future reintervention and coronary access is a concern. AIMS: To assess the impact of commissural alignment on ACURATE neo2 transcatheter aortic valve (TAV) performance. METHODS: COMALIGN-neo2 was an observational, retrospective study enrolling consecutive TAVR patients treated with the ACURATE neo2 (October 2021 to October 2022). The degree of commissural (mis)-alignment (CMA) with the native aortic valve commissures was determined and transvalvular gradient, effective orifice area, patient-prosthesis mismatch (PPM), and aortic regurgitation (AR) were assessed. RESULTS: Among 825 patients, the mean age was 80.7 years and 42% were female. Commissural alignment was achieved in 60% of cases; mild (26%), moderate (9%), and severe misalignment (5%) were found less often. Severe PPM occurred more frequently in patients with severe CMA (14.7%) compared to aligned valves (p = 0.034). By multivariate analysis, severe CMA (odds ratio [OR]: 3.12, 95% confidence interval [CI] [1.09-8.90]; p = 0.033) and lack of postdilatation (OR: 3.85, [1.33-11.1]; p = 0.012) were associated with severe PPM. Higher rates of ≥mild AR (51.4%) were found in TAVs implanted with severe CMA compared to aligned (34.3%), mildly (38.1%) or moderately (36.0%) misaligned TAVs (p = 0.030). Multivariate analysis identified severe CMA (OR: 2.05, [1.05-4.02]; p = 0.037) to be an independent predictor of ≥mild AR. CONCLUSIONS: COMALIGN-neo2 is the largest study to date assessing the impact of commissural alignment on acute TAV performance. Severe CMA with the ACURATE neo2 platform was associated with worse valve hemodynamics and increased risk for mild AR.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Recuperação de Função Fisiológica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Masculino , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Idoso , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Resultado do Tratamento , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo
5.
JACC Cardiovasc Interv ; 17(14): 1652-1663, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-38749449

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: The aim of this study was to identify the incidence, predictors, and clinical outcomes of PVR after TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with Sievers type 1 BAV stenosis undergoing TAVR with current-generation transcatheter heart valves (THVs) in 24 international centers were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAEs), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%)-mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were a larger virtual raphe ring perimeter (adjusted OR: 1.07; 95% CI: 1.02-1.13), severe annular or left ventricular outflow tract calcification (adjusted OR: 5.21; 95% CI: 1.45-18.77), a self-expanding valve (adjusted OR: 9.01; 95% CI: 2.09-38.86), and intentional supra-annular THV positioning (adjusted OR: 3.31; 95% CI: 1.04-10.54). At a median follow-up of 1.3 years (Q1-Q3: 0.5-2.4 years), moderate or severe PVR was associated with an increased risk of MAEs (adjusted HR: 2.52; 95% CI: 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAEs during follow-up.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Fatores de Risco , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Resultado do Tratamento , Idoso de 80 Anos ou mais , Incidência , Fatores de Tempo , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/fisiopatologia , Europa (Continente) , Medição de Risco , Desenho de Prótese , Razão de Chances , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/diagnóstico , Estudos Retrospectivos
6.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38479968

RESUMO

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento , Sistema de Registros , Acidente Vascular Cerebral/etiologia
8.
Am J Cardiol ; 219: 60-70, 2024 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-38401656

RESUMO

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Fatores Sexuais , Idoso de 80 Anos ou mais , Idoso , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Valva Aórtica/cirurgia
9.
EuroIntervention ; 20(2): e158-e167, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38224253

RESUMO

BACKGROUND: Both surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) are Class Ia recommended therapies for specific subgroups of severe aortic stenosis (AS) patients in the latest 2021 European guidelines. AIMS: We aimed to report on the multidisciplinary Heart Team evaluation process and real-world practice of treating severe symptomatic AS in East Denmark in the context of the latest European guideline recommendations. METHODS: All consecutive patients with severe AS referred for intervention in 2021 (N=672) were discussed in a multidisciplinary Heart Team meeting. All patients (100%) had a cardiac computed tomography (CT) analysis prior to the meeting. Baseline characteristics, Heart Team decision-making, final treatment and 30-day clinical outcomes were prospectively recorded. RESULTS: The majority of severe AS patients (N=456, 68%) were referred for TAVI following discussion in the Heart Team. Ultimately, 94% of patients (N=632) received the Heart Team-recommended treatment. Patients undergoing TAVI (N=439) were significantly older (78.4±6.7 vs 67.2±8.3 years; p<0.001) and more comorbid than patients undergoing SAVR (N=189). The overall 30-day clinical outcomes were satisfactory for both treatment groups (overall 30-day mortality: 1.1%). The mean index hospitalisation length was markedly longer in the SAVR group (8.6±8.3 days) as compared to the TAVI group (1.8±3.2 days). CONCLUSIONS: TAVI was routinely performed in low surgical risk patients in 2021 with two-thirds of all severe AS patients undergoing TAVI, thereby applying the latest European guidelines. A dedicated Heart Team meeting, including CT evaluation for all AS patients, is needed to make individualised management decisions in this new era of aortic valve interventions.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Coração , Hospitalização , Pacientes , Estenose da Valva Aórtica/cirurgia
11.
EuroIntervention ; 20(6): e354-e362, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-37982158

RESUMO

BACKGROUND: Despite transcatheter aortic valve implantation (TAVI) having become a routine procedure, access site bleeding and vascular complications are still a concern which contribute to procedure-related morbidity and mortality. AIMS: The TAVI-MultiCLOSE study aimed to assess the safety and efficacy of a new vascular closure algorithm for percutaneous large-bore arterial access closure following transfemoral (TF)-TAVI. METHODS: All consecutive TF-TAVI cases in which the MultiCLOSE vascular closure algorithm was used were prospectively included in a multicentre, observational study. This stepwise algorithm entails the reinsertion of a 6-8 Fr sheath (primary access) following the initial preclosure with one or two suture-based vascular closure devices (VCDs). This provides the operator with the opportunity to perform a quick and easy angiographic control and tailor the final vascular closure with either an additional suture- or plug-based VCD, or neither of these. RESULTS: Among 630 patients who underwent TF-TAVI utilising the MultiCLOSE algorithm, complete arterial haemostasis was achieved in 616 patients (98%). VCD failure occurred in 14 patients (2%), treated with either balloon inflation (N=1), covered stent (N=12) or surgical repair (N=1). Overall, this vascular closure approach resulted in a minor and major vascular complication rate of 2.2% and 0.6%, respectively. At 30 days, only one new minor vascular complication (0.2%) was noted. In-hospital and 30-day all-cause mortality rates were 0.2% and 1.0%, respectively. CONCLUSIONS: Use of the MultiCLOSE vascular closure algorithm was demonstrated to contribute to an easy, safe, efficacious and durable vascular closure after TF-TAVI, resulting in a major vascular complication rate of less than 1%.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Hemorragia/etiologia , Hemorragia/prevenção & controle , Técnicas Hemostáticas/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Dispositivos de Oclusão Vascular/efeitos adversos
12.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982161

RESUMO

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Desenho de Prótese
15.
Eur Heart J Case Rep ; 7(7): ytad310, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37501711

RESUMO

Background: The transfemoral (TF) approach drives most of the advantages of transcatheter aortic valve implantation (TAVI) over surgical aortic valve replacement. Alternative accesses for TAVI are associated with higher complication rates, but are still considered in ∼5% of cases due to peripheral arterial disease (PAD). Percutaneous transluminal angioplasty can still allow TF-TAVI in selected cases with severe calcific PAD; however, ancillary techniques for calcium management are often needed. Case Summary: Orbital atherectomy was selected to facilitate TF-TAVI in two patients with different degrees and aspects of calcific PAD. Pre-procedural computed tomography analysis was key to choose the most appropriate technique for calcium management. We describe our experience with a step-by-step procedural approach to orbital atherectomy-assisted TF-TAVI. Discussion: PAD is not uncommon in patients affected by severe symptomatic aortic valve stenosis. Orbital atherectomy can still allow TF-TAVI in selected cases with severe calcific PAD. A meticulous patient selection and a standardized, step-wise procedural execution are mandatory to optimize outcomes.

17.
Front Cardiovasc Med ; 10: 1195397, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37229228

RESUMO

Encouraged by randomized controlled trials demonstrating non-inferiority of transfemoral transcatheter aortic valve implantation (TAVI) compared to surgical aortic valve replacement (SAVR) across all surgical risk categories, there has been a dramatic increase in the use of TAVI in a younger patient cohort with severe aortic stenosis, endorsed by both European and American Cardiac Societies. However, the standard use of TAVI in younger, less co-morbid patients with a longer life expectancy can only be supported if there is sound data demonstrating long-term durability of transcatheter aortic valves (TAVs). In this article, we have reviewed available randomized and observational registry clinical data pertaining to TAV long-term durability, placing emphasis on trials and registries using the new standardized definitions of bioprosthetic valve dysfunction (BVD) and bioprosthetic valve failure (BVF). Despite inherent difficulties in interpreting the available data, the determination reached is that the risk of structural valve deterioration (SVD) is potentially lower after TAVI than SAVR at 5 to 10 years, and that the two treatment modalities have a similar risk of BVF. This supports the adoption of TAVI in younger patients evident in current practice. However, the routine use of TAVI in younger patients with bicuspid aortic valve stenosis should be cautioned due to insufficient long-term TAV durability data in this particular patient population. Finally, we highlight the importance of future research into the unique potential mechanisms that can potentially contribute to TAV degeneration.

18.
Int J Cardiovasc Imaging ; 39(8): 1557-1559, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37149839

RESUMO

A higher incidence of conduction disturbances and permanent pacemaker implantation (PPI) has been observed after transcatheter aortic valve implantation (TAVI) in patients with bicuspid aortic valves (BAVs) as compared to those with tricuspid aortic valves (TAVs). This study aimed to provide an anatomical explanation for this observation, supported by an in-depth anatomical mapping of the membranous septum (MS) in a large cohort of BAVs and TAVs using cardiac computed tomography (CT). A total of 300 cardiac CT scans were analysed, revealing a significantly shorter sub-annular length of the MS in BAVs at all measuring points compared to TAVs (p < 0.001). In the current BAV cohort, the MS was found to be at its shortest at the RCC site, measuring less than 1 mm in depth. In addition, the MS was located more anteriorly towards the RCC in BAVs, where the transcatheter aortic valve tends to be implanted deeper, and we observed a trend towards a higher PPI rate in BAVs. Future studies should investigate whether anatomical mapping of the MS in patients undergoing TAVI could be a useful tool for decision-making and potentially mitigate the risk of conduction disturbances.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Carcinoma de Células Renais , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Neoplasias Renais , Substituição da Valva Aórtica Transcateter , Humanos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Valor Preditivo dos Testes , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
19.
J Clin Med ; 12(6)2023 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-36983139

RESUMO

Transcatheter aortic valve implantation (TAVR) is the first therapeutic option for elderly patients with severe symptomatic aortic stenosis, and indications are steadily expanding to younger patients and subjects with lower surgical risk and longer life expectancy. Commissural alignment between native and transcatheter valves facilitates coronary access after TAVR and is thus considered a procedural goal, allowing long-term management of coronary artery disease. Moreover, commissural alignment may potentially have a positive impact on transvalvular hemodynamic and valve durability. This review focus on technical hints to achieve commissural alignment and current evidence for different transcatheter aortic valves.

20.
Catheter Cardiovasc Interv ; 101(3): 655-659, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36651342

RESUMO

Valve-in-valve transcatheter aortic valve replacement (VIV-TAVR) for a degenerated surgical aortic bioprosthesis is a well-established treatment modality but carries an increased risk of coronary artery obstruction (CAO) with potentially catastrophic consequences. Both chimney stenting and leaflet modification by BASILICA (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Obstruction) are increasingly employed and can be highly effective means of preventing CAO. Using a case report, in which both strategies were utilized, as a platform for detailed discussion, we address the indications, contraindications, and relative merits of each technique in the prevention of CAO.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Oclusão Coronária , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Vasos Coronários/cirurgia , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Oclusão Coronária/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA