Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Nat Commun ; 15(1): 3864, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38740802

RESUMO

Despite its great scientific and technological importance, wall-bounded turbulence is an unresolved problem in classical physics that requires new perspectives to be tackled. One of the key strategies has been to study interactions among the energy-containing coherent structures in the flow. Such interactions are explored in this study using an explainable deep-learning method. The instantaneous velocity field obtained from a turbulent channel flow simulation is used to predict the velocity field in time through a U-net architecture. Based on the predicted flow, we assess the importance of each structure for this prediction using the game-theoretic algorithm of SHapley Additive exPlanations (SHAP). This work provides results in agreement with previous observations in the literature and extends them by revealing that the most important structures in the flow are not necessarily the ones with the highest contribution to the Reynolds shear stress. We also apply the method to an experimental database, where we can identify structures based on their importance score. This framework has the potential to shed light on numerous fundamental phenomena of wall-bounded turbulence, including novel strategies for flow control.

4.
Infect Control Hosp Epidemiol ; 43(8): 987-992, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34266516

RESUMO

OBJECTIVE: To study the airflow, transmission, and clearance of aerosols in the clinical spaces of a hospital ward that had been used to care for patients with coronavirus disease 2019 (COVID-19) and to examine the impact of portable air cleaners on aerosol clearance. DESIGN: Observational study. SETTING: A single ward of a tertiary-care public hospital in Melbourne, Australia. INTERVENTION: Glycerin-based aerosol was used as a surrogate for respiratory aerosols. The transmission of aerosols from a single patient room into corridors and a nurses' station in the ward was measured. The rate of clearance of aerosols was measured over time from the patient room, nurses' station and ward corridors with and without air cleaners [ie, portable high-efficiency particulate air (HEPA) filters]. RESULTS: Aerosols rapidly travelled from the patient room into other parts of the ward. Air cleaners were effective in increasing the clearance of aerosols from the air in clinical spaces and reducing their spread to other areas. With 2 small domestic air cleaners in a single patient room of a hospital ward, 99% of aerosols could be cleared within 5.5 minutes. CONCLUSIONS: Air cleaners may be useful in clinical spaces to help reduce the risk of acquisition of respiratory viruses that are transmitted via aerosols. They are easy to deploy and are likely to be cost-effective in a variety of healthcare settings.


Assuntos
Filtros de Ar , COVID-19 , Ar Condicionado , COVID-19/prevenção & controle , Hospitais , Humanos , Aerossóis e Gotículas Respiratórios
5.
Aust Crit Care ; 35(1): 28-33, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34144863

RESUMO

BACKGROUND: Healthcare workers (HCWs) have frequently become infected with severe acute respiratory syndrome coronavirus 2 whilst treating patients with coronavirus disease 2019 (COVID-19). A variety of novel devices have been proposed to reduce COVID-19 cross-contamination. OBJECTIVES: The aim of the study was (i) to test whether patients and HCWs thought that a novel patient isolation hood was safe and comfortable and (ii) to obtain COVID-19 infection data of hospital HCWs. METHODS: This is a prospective cohort study of 20 patients, entailing HCW/patient questionnaires and safety aspects of prototype isolation hoods. COVID-19 data of HCWs were prospectively collected. Assessment of the hood's safety and practicality and adverse event reporting was carried out. OUTCOME MEASURES: The outcome measures are as follows: questionnaire responses, adverse event reporting, rates of infections in HCWs during the study period (20/6/2020 to 21/7/2020), and COVID-19 infections in HCWs reported until the last recorded diagnosis of COVID-19 in HCWs (20/6/2020 to 27/9/2020). RESULTS: Of the 64 eligible individual HCW surveys, 60 surveys were overall favourable (>75% questions answered in favour of the isolation hood). HCWs were unanimous in perceiving the hood as safe (60/60), preferring its use (56/56), and understanding its potential COVID-19 cross-contamination minimisation (60/60). All eight patients who completed the questionnaire thought the isolation hood helped prevent COVID-19 cross infection and was safe and comfortable. There were no reported patient safety adverse events. The COVID-19 attack rate from 20/6/2020 to 27/9/2020 among registered nurses was as follows: intensive care units (ICUs), 2.2% (3/138); geriatric wards, 13.2% (26/197); and COVID-19 wards, 18.3% (32/175). The COVID-19 attack rate among medical staff was as follows: junior staff, 2.1% (24/932); senior staff, 0.7% (4/607); aged care/rehabilitation, 6.7% (2/30); and all ICU medical staff, 8.6% (3/35). CONCLUSIONS: The isolation hood was preferred to standard care by HCWs and well tolerated by patients, and after the study, isolation hoods became part of standard ICU therapy. There was an association between being an ICU nurse and a low COVID-19 infection rate (no causality implied). ICU HCWs feel safer when treating patients with COVID-19 using an isolation hood.


Assuntos
COVID-19 , Idoso , Humanos , Pandemias , Isolamento de Pacientes , Estudos Prospectivos , SARS-CoV-2
6.
Crit Care Resusc ; 22(3): 212-220, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32900327

RESUMO

OBJECTIVE: To quantify aerosol generation from respiratory interventions and the effectiveness of their removal by a personal ventilation hood. DESIGN AND SETTING: Determination of the aerosol particle generation (in a single, healthy volunteer in a clean room) associated with breathing, speaking, wet coughing, oxygen (O2) 15 L/min via face mask, O2 60 L/min via nasal prongs, bilevel non-invasive positive-pressure ventilation (BiPAP) and nebulisation with O2 10 L/min. INTERVENTIONS: Aerosol generation was measured with two particle sizer and counter devices, focusing on aerosols 0.5-5 µm (human-generated aerosols), with and without the hood. An increase from baseline of less than 0.3 particles per mL was considered a low level of generation. MAIN OUTCOME MEASURES: Comparisons of aerosol generation between different respiratory interventions. Effectiveness of aerosol reduction by a personal ventilation hood. RESULTS: Results for the 0.5-5 µm aerosol range. Quiet breathing and talking demonstrated very low increase in aerosols (< 0.1 particles/mL). Aerosol generation was low for wet coughing (0.1 particles/mL), O2 15 L/min via face mask (0.18 particles/mL), and high flow nasal O2 60 L/min (0.24 particles/mL). Non-invasive ventilation generated moderate aerosols (29.7 particles/mL) and nebulisation very high aerosols (1086 particles/mL); the personal ventilation hood reduced the aerosol counts by 98% to 0.5 particles/mL and 8.9 particles/mL respectively. CONCLUSIONS: In this human volunteer study, the administration of O2 15 L/min by face mask and 60 L/min nasal therapy did not increase aerosol generation beyond low levels. Non-invasive ventilation caused moderate aerosol generation and nebulisation therapy very high aerosol generation. The personal ventilation hood reduced the aerosol counts by at least 98%.


Assuntos
Aerossóis , Pulmão/metabolismo , Máscaras , Oxigênio , Respiração , Administração por Inalação , Humanos , Pulmão/diagnóstico por imagem , Resultado do Tratamento
7.
Int J Cardiovasc Imaging ; 33(7): 1083-1088, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28220273

RESUMO

Virtual fractional flow reserve (vFFR) has been evaluated as an adjunct to invasive fractional flow reserve (FFR) in the light of its operational and economic benefits. The accuracy of vFFR and the complexity of hyperemic flow simulation are still not clearly understood. This study investigates the flow-pressure relation in an idealised multiple sequential stenoses coronary artery model via numerical and experimental approaches. Pressure drop is linearly correlated with flow rate irrespective of the number of stenosis. Computational fluid dynamics results are in good agreement with the experimental data, demonstrating reasonable accuracy of vFFR. It was also found that the difference between data obtained with steady and pulsatile flows is negligible, indicating the steady flow may be used instead of pulsatile flow conditions in vFFR computation. This study adds to the current understanding of vFFR and may improve its clinical applicability as an adjunct to invasively determined FFR.


Assuntos
Pressão Arterial , Simulação por Computador , Estenose Coronária/diagnóstico , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Modelos Anatômicos , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo , Estenose Coronária/fisiopatologia , Humanos , Hidrodinâmica , Hiperemia/fisiopatologia , Modelos Lineares , Análise Numérica Assistida por Computador , Valor Preditivo dos Testes , Prognóstico , Fluxo Pulsátil , Índice de Gravidade de Doença
8.
Coron Artery Dis ; 26 Suppl 1: e43-54, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26247271

RESUMO

Percutaneous coronary intervention (PCI) has shown a high success rate in the treatment of coronary artery disease. The decision to perform PCI often relies on the cardiologist's visual interpretation of coronary lesions during angiography. This has inherent limitations, particularly due to the low resolution and two-dimensional nature of angiography. State-of-the-art modalities such as three-dimensional quantitative coronary angiography, optical coherence tomography and invasive fractional flow reserve (FFR) may improve clinicians' understanding of both the anatomical and physiological importance of coronary lesions. While invasive FFR is the gold standard technique for assessment of the haemodynamic significance of coronary lesions, recent studies have explored a surrogate for FFR derived solely from three-dimensional reconstruction of the invasive angiogram, and therefore eliminating need for a pressure wire. Utilizing advanced computational fluid dynamics research, this virtual fractional flow reserve (vFFR) has demonstrated reasonable correlation with invasive measurements and remains an intense area of ongoing study. However, at present, several limitations and computational fluid dynamic assumptions may preclude vFFR from widespread clinical use. This review demonstrates the tight integration of advanced three-dimensional imaging techniques and vFFR in assessing coronary artery disease, reviews the advantages and disadvantages of such techniques and attempts to provide a glimpse of how such advances may benefit future clinical decision-making during PCI.


Assuntos
Cateterismo Cardíaco/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/fisiopatologia , Diagnóstico por Imagem/métodos , Reserva Fracionada de Fluxo Miocárdico , Imageamento Tridimensional , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Humanos , Modelos Cardiovasculares , Intervenção Coronária Percutânea , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia de Coerência Óptica , Resultado do Tratamento
9.
Rev Sci Instrum ; 83(10): 103705, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126772

RESUMO

The spring constant of an atomic force microscope cantilever is often needed for quantitative measurements. The calibration method of Sader et al. [Rev. Sci. Instrum. 70, 3967 (1999)] for a rectangular cantilever requires measurement of the resonant frequency and quality factor in fluid (typically air), and knowledge of its plan view dimensions. This intrinsically uses the hydrodynamic function for a cantilever of rectangular plan view geometry. Here, we present hydrodynamic functions for a series of irregular and non-rectangular atomic force microscope cantilevers that are commonly used in practice. Cantilever geometries of arrow shape, small aspect ratio rectangular, quasi-rectangular, irregular rectangular, non-ideal trapezoidal cross sections, and V-shape are all studied. This enables the spring constants of all these cantilevers to be accurately and routinely determined through measurement of their resonant frequency and quality factor in fluid (such as air). An approximate formulation of the hydrodynamic function for microcantilevers of arbitrary geometry is also proposed. Implementation of the method and its performance in the presence of uncertainties and non-idealities is discussed, together with conversion factors for the static and dynamic spring constants of these cantilevers. These results are expected to be of particular value to the design and application of micro- and nanomechanical systems in general.


Assuntos
Fenômenos Mecânicos , Microscopia de Força Atômica/instrumentação , Calibragem , Elasticidade , Hidrodinâmica , Incerteza
10.
Biofouling ; 28(4): 381-93, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22509778

RESUMO

Whole cell, strength of adhesion assays of three different isolates of the fouling diatom Amphora coffeaeformis were compared using a hydrophilic surface viz. acid washed glass (AWG), and a hydrophobic surface viz. a self assembled monolayer (SAM) of undecanethiol (UDT). Assays were performed using a newly designed turbulent flow channel that permits direct observation and recording of cell populations on a test surface. Exposure to continuous shear stress over 3 h revealed that the more motile isolate, WIL2, adhered much more strongly to both test surfaces compared to the other two strains. When the response of the isolates to shear stress after 3 h was compared, there was no significant difference in the percentage of cells removed, irrespective of surface wettability. Cells of the three isolates of A. coffeaeformis varied significantly in their response to different surfaces during initial adhesion, indicating the presence of a wide range of 'physiological races' within this species.


Assuntos
Incrustação Biológica , Adesão Celular/fisiologia , Diatomáceas/citologia , Adaptação Fisiológica , Propriedades de Superfície , Movimentos da Água , Molhabilidade
11.
Rev Sci Instrum ; 82(9): 095104, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21974616

RESUMO

The thermal noise spectrum of nanomechanical devices is commonly used to characterize their mechanical properties and energy dissipation. This spectrum is measured from finite time series of Brownian motion of the device, which is windowed and Fourier transformed. Here, we present a theoretical and experimental investigation of the effect of such finite sampling on the measured device quality factor. We prove that if no spectral window is used, the thermal noise spectrum retains its original Lorentzian distribution but with a reduced quality factor, indicating an apparent enhancement in energy dissipation. A simple analytical formula is derived connecting the true and measured quality factors - this enables extraction of the true device quality factor from measured data. Common windows used to reduce spectral leakage are found to distort the (true) Lorentzian shape, potentially making fitting problematic. These findings are expected to be of particular importance for devices with high quality factors, where spectral resolution can be limited in practice. Comparison and validation using measurements on atomic force microscope cantilevers are presented.

SELEÇÃO DE REFERÊNCIAS