OBJECTIVE: To conduct a multicenter case series characterizing the clinical characteristics at presentation and pancreatic volume changes of patients with checkpoint inhibitor-associated autoimmune diabetes (CIADM). RESEARCH DESIGN AND METHODS: Electronic medical records were reviewed with 36 consecutive patients identified with CIADM, as defined by (1) previous immune checkpoint inhibitor (ICI) therapy, (2) new-onset hyperglycemia (blood glucose level ≥ 11.1 mmol/L and/or glycosylated hemoglobin ≥ 6.5%), and (3) insulin deficiency [C-peptide <0.4 nmol/L or diabetic ketoacidosis (DKA)] within 1 month of presentation. Pancreatic volume was available and measured using computed tomography volumetry for 17 patients with CIADM and 3 sets of control patients: 7 with ICI-related pancreatitis, 13 with asymptomatic ICI-related lipase elevation, and 11 ICI-treated controls for comparison. RESULTS: All patients had either anti-programmed cell death protein 1 or anti-programmed cell death ligand 1 therapy. Median time from ICI commencement to CIADM diagnosis was 15 weeks. At presentation, 25 (69%) had DKA, 27 (84%) had low C-peptide, and, by 1 month, 100% had low C-peptide. Traditional type 1 diabetes autoantibodies were positive in 15/35 (43%). Lipase was elevated in 13/27 (48%) at presentation. In 4 patients with longitudinal lipase testing, elevated levels peaked 1 month prior to CIADM diagnosis. Pancreatic volume was lower pre-ICI in CIADM patients compared with controls and demonstrated a mean decline of 41% from pretreatment to 6 months post-CIADM diagnosis. CONCLUSION: Pronounced biochemical and radiologic changes occur during CIADM pathogenesis. Rapid loss of C-peptide is a distinct characteristic that can be used to aid diagnosis as autoantibodies are often negative.

2.
Phys Med Biol ; 68(16)2023 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-37327792

RESUMO

Objective. Cerebral CT perfusion (CTP) imaging is most commonly used to diagnose acute ischaemic stroke and support treatment decisions. Shortening CTP scan duration is desirable to reduce the accumulated radiation dose and the risk of patient head movement. In this study, we present a novel application of a stochastic adversarial video prediction approach to reduce CTP imaging acquisition time.Approach. A variational autoencoder and generative adversarial network (VAE-GAN) were implemented in a recurrent framework in three scenarios: to predict the last 8 (24 s), 13 (31.5 s) and 18 (39 s) image frames of the CTP acquisition from the first 25 (36 s), 20 (28.5 s) and 15 (21 s) acquired frames, respectively. The model was trained using 65 stroke cases and tested on 10 unseen cases. Predicted frames were assessed against ground-truth in terms of image quality and haemodynamic maps, bolus shape characteristics and volumetric analysis of lesions.Main results. In all three prediction scenarios, the mean percentage error between the area, full-width-at-half-maximum and maximum enhancement of the predicted and ground-truth bolus curve was less than 4 ± 4%. The best peak signal-to-noise ratio and structural similarity of predicted haemodynamic maps was obtained for cerebral blood volume followed (in order) by cerebral blood flow, mean transit time and time to peak. For the 3 prediction scenarios, average volumetric error of the lesion was overestimated by 7%-15%, 11%-28% and 7%-22% for the infarct, penumbra and hypo-perfused regions, respectively, and the corresponding spatial agreement for these regions was 67%-76%, 76%-86% and 83%-92%.Significance. This study suggests that a recurrent VAE-GAN could potentially be used to predict a portion of CTP frames from truncated acquisitions, preserving the majority of clinical content in the images, and potentially reducing the scan duration and radiation dose simultaneously by 65% and 54.5%, respectively.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Redes Neurais de Computação , Imagem de Perfusão/métodos , Circulação Cerebrovascular/fisiologia , Doses de Radiação
3.
Eur J Radiol ; 144: 109979, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34678666

RESUMO

PURPOSE: To quantitatively characterise head motion prevalence and severity and to identify patient-based risk factors for motion during cerebral CT perfusion (CTP) imaging of acute ischaemic stroke. METHODS: The head motion of 80 stroke patients undergoing CTP imaging was classified retrospectively into four categories of severity. Each motion category was then characterised quantitatively based on the average head movement with respect to the first frame for all studies. Statistical testing and principal component analysis (PCA) were then used to identify and analyse the relationship between motion severity and patient baseline features. RESULTS: 46/80 (58%) of patients showed negligible motion, 19/80 (24%) mild-to-moderate motion, and 15/80 (19%) considerable-to-extreme motion sufficient to affect diagnostic/therapeutic accuracy even with correction. The most prevalent movement was "nodding" with maximal translation/rotation in the sagittal/axial planes. There was a tendency for motion to worsen as scan proceeded and for faster motion to occur in the first 15 s. Statistical analyses showed that greater stroke severity (National Institutes of Health Stroke Scale (NIHSS)), older patient age and shorter time from stroke onset were predictive of increased head movement (p < 0.05 Kruskal-Wallis). Using PCA, the combination of NIHSS and patient age was found to be highly predictive of head movement (p < 0.001). CONCLUSIONS: Quantitative methods were developed to characterise CTP studies impacted by motion and to anticipate patients at-risk of motion. NIHSS, age, and time from stroke onset function as good predictors of motion likelihood and could potentially be used pre-emptively in CTP scanning of acute stroke.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Isquemia Encefálica/diagnóstico por imagem , Movimentos da Cabeça , Humanos , Imagem de Perfusão , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
4.
Phys Med Biol ; 66(7)2021 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-33621965

RESUMO

Dose reduction in cerebral CT perfusion (CTP) imaging is desirable but is accompanied by an increase in noise that can compromise the image quality and the accuracy of image-based haemodynamic modelling used for clinical decision support in acute ischaemic stroke. The few reported methods aimed at denoising low-dose CTP images lack practicality by considering only small sections of the brain or being computationally expensive. Moreover, the prediction of infarct and penumbra size and location-the chief means of decision support for treatment options-from denoised data has not been explored using these approaches. In this work, we present the first application of a 3D generative adversarial network (3D GAN) for predicting normal-dose CTP data from low-dose CTP data. Feasibility of the approach was tested using real data from 30 acute ischaemic stroke patients in conjunction with low dose simulation. The 3D GAN model was applied to 643voxel patches extracted from two different configurations of the CTP data-frame-based and stacked. The method led to whole-brain denoised data being generated for haemodynamic modelling within 90 s. Accuracy of the method was evaluated using standard image quality metrics and the extent to which the clinical content and lesion characteristics of the denoised CTP data were preserved. Results showed an average improvement of 5.15-5.32 dB PSNR and 0.025-0.033 structural similarity index (SSIM) for CTP images and 2.66-3.95 dB PSNR and 0.036-0.067 SSIM for functional maps at 50% and 25% of normal dose using GAN model in conjunction with a stacked data regime for image synthesis. Consequently, the average lesion volumetric error reduced significantly (p-value <0.05) by 18%-29% and dice coefficient improved significantly by 15%-22%. We conclude that GAN-based denoising is a promising practical approach for reducing radiation dose in CTP studies and improving lesion characterisation.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Encéfalo/diagnóstico por imagem , Isquemia Encefálica/diagnóstico por imagem , Redução da Medicação , Estudos de Viabilidade , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagem de Perfusão , Tomografia Computadorizada por Raios X/métodos