J Environ Manage ; 90(11): 3629-34, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19643526

RESUMO

When an explosive detonates or a propellant or flare burns, consumption of the energetic filler should be complete but rarely is, especially in the presence of large amounts of non-combustible materials. Herein we examine three types of perchlorate-containing devices to estimate their potential as sources of contamination in their normal mode of functioning. Road flares, rocket propellants and ammonium nitrate (AN) emulsion explosives are potentially significant anthropogenic sources of perchlorate contamination. This laboratory evaluated perchlorate residue from burning of flares and propellants as well as detonations of ammonium nitrate emulsion explosives. Residual perchlorate in commercial products ranged from 0.094mg perchlorate per gram material (flares) to 0.012mg perchlorate per gram material (AN emulsion explosives). The rocket propellant formulations, prepared in this laboratory, generated 0.014mg of perchlorate residue per gram of material.


Assuntos
Propelentes de Aerossol/química , Substâncias Explosivas/química , Percloratos/química , Meios de Transporte , Monitoramento Ambiental