Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Haemophilia ; 30(1): 161-168, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38013388

RESUMO

INTRODUCTION: VWD diagnosis is challenging requiring multiple VWF activity tests using many individual assays. We have developed an ELISA-based VWF Multiplex Activity Assay (VWF-MAA) to address this concern; however, the ability of the VWF-MAA to discriminate between type 1 VWD, variant VWD, and normal subjects has not been evaluated. AIM: To evaluate the VWF-MAA and its ability to differentiate between type 1 VWD, variant VWD and normal subjects in individuals undergoing an initial laboratory evaluation for bleeding. METHODS: A total of 177 plasma samples from the Zimmerman Program: Comparative Effectiveness in the Diagnosis of VWD were evaluated from 11 centres across the US and Canada. The VWF-MAA was compared to Versiti Blood Research Institute (VBRI) and Local Center (LC) assigned VWD diagnosis. RESULTS: Overall, 129/177 (72.9%) were correctly assigned as normal (non-VWD), type 1, or variant VWD compared to the VBRI assigned diagnosis. VWF-MAA assigned non-VWD accurately in 29/57 (50.9%) samples, and type 1 VWD accurately in 93/110 (84.6%) samples. Considering LC diagnosis where there was agreement with VWF-MAA and not VBRI diagnosis, type 1 VWD was accurate in 105/110 (95.5%) samples. Bland-Altman analysis demonstrated good correlation between laboratory methods. VWD, types 2A, 2B, 1C VWD were also assigned by the VWF-MAA. CONCLUSIONS: We demonstrate that the VWF-MAA has utility in differentiating type 1 VWD, variant VWD and normal subjects in individuals undergoing an initial laboratory evaluation for bleeding.


Assuntos
Doença de von Willebrand Tipo 1 , Doença de von Willebrand Tipo 2 , Doenças de von Willebrand , Humanos , Fator de von Willebrand/análise , Doença de von Willebrand Tipo 1/diagnóstico , Doenças de von Willebrand/diagnóstico , Hemorragia , Canadá , Doença de von Willebrand Tipo 2/diagnóstico
2.
Blood ; 127(20): 2472-80, 2016 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-26917779

RESUMO

Approximately 20% to 25% of patients with von Willebrand disease (VWD) have a qualitative defect of the von Willebrand factor (VWF) protein activities. Variant VWD typically is classified as type 1C, 2A, 2B, 2M, or 2N depending on the VWF activity defect. Traditionally, diagnosis has relied on multiple clinical laboratory assays to assign VWD phenotype. We developed an enzyme-linked immunosorbent assay (ELISA) to measure the various activities of VWF on a single plate and evaluated 160 patient samples enrolled in the Zimmerman Program for the Molecular and Clinical Biology of von Willebrand Disease with type 2 VWD. Using linear discriminate analysis (LDA), this assay was able to identify type 1C, 2A, 2B, 2M, or 2N VWD with an overall accuracy of 92.5% in the patient study cohort. LDA jackknife analysis, a statistical resampling technique, identified variant VWD with an overall accuracy of 88.1%, which predicts the assay's performance in the general population. In addition, this assay demonstrated correlation with traditional clinical laboratory VWF assays. The VWF multiplex activity assay may be useful as a same-day screening assay when considering the diagnosis of variant VWD in an individual patient.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Doenças de von Willebrand/classificação , Fator de von Willebrand/análise , Confiabilidade dos Dados , Análise Discriminante , Testes Genéticos , Genótipo , Hemofilia A/sangue , Humanos , Fenótipo , Probabilidade , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo , Doenças de von Willebrand/sangue , Doenças de von Willebrand/diagnóstico , Doenças de von Willebrand/genética , Fator de von Willebrand/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA