Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 85(15): 7139-45, 2013 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-23799655

RESUMO

Expression microdissection (xMD) is a high-throughput, operator-independent technology that enables the procurement of specific cell populations from tissue specimens. In this method, histological sections are first stained for cellular markers via either chemical or immuno-guided methods, placed in close contact with an ethylene vinyl acetate (EVA) film, and exposed to a light source. The focal, transient heating of the stained cells or subcellular structures melts the EVA film selectively to the targets for procurement. In this report, we introduce a custom-designed flashcube system that permits consistent and reproducible microdissection of nuclei across an FFPE rat brain tissue section in milliseconds. In addition, we present a method to efficiently recover and combine captured proteins from multiple xMD films. Both light and scanning electron microscopy demonstrated captured nuclear structures. Shotgun proteomic analysis of the samples showed a significant enrichment in nuclear localized proteins, with an average 25% of recovered proteins localized to the nucleus, versus 15% for whole tissue controls (p < 0.001). Targeted mass spectrometry using multiple reaction monitoring (MRM) showed more impressive data, with a 3-fold enrichment in histones, and a concurrent depletion of proteins localized to the cytoplasm, cytoskeleton, and mitochondria. These data demonstrate that the flashcube-xMD technology is applicable to the proteomic study of a broad range of targets in molecular pathology.


Assuntos
Encéfalo/citologia , Núcleo Celular/metabolismo , Microdissecção/métodos , Proteômica/métodos , Sequência de Aminoácidos , Animais , Precipitação Química , Formaldeído/metabolismo , Espectrometria de Massas , Dados de Sequência Molecular , Inclusão em Parafina , Proteólise , Ratos , Fixação de Tecidos
2.
J Micromech Microeng ; 22(10): 105007, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23066175

RESUMO

We describe the design and fabrication trials of x-ray absorption gratings of 200 nm period and up to 100:1 depth-to-period ratios for full-field hard x-ray imaging applications. Hard x-ray phase-contrast imaging relies on gratings of ultra-small periods and sufficient depth to achieve high sensitivity. Current grating designs utilize lithographic processes to produce periodic vertical structures, where grating periods below 2.0 µm are difficult due to the extreme aspect ratios of the structures. In our design, multiple bilayers of x-ray transparent and opaque materials are deposited on a staircase substrate, and mostly on the floor surfaces of the steps only. When illuminated by an x-ray beam horizontally, the multilayer stack on each step functions as a micro-grating whose grating period is the thickness of a bilayer. The array of micro-gratings over the length of the staircase works as a single grating over a large area when continuity conditions are met. Since the layers can be nanometers thick and many microns wide, this design allows sub-micron grating periods and sufficient grating depth to modulate hard x-rays. We present the details of the fabrication process and diffraction profiles and contact radiography images showing successful intensity modulation of a 25 keV x-ray beam.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA