Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 141
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39011511

RESUMO

Objectives: To evaluate the results of inside stent therapy for unresectable malignant hilar biliary obstruction and identify factors related to stent patency duration. Methods: Of 44 patients who underwent initial inside-stent placement above the sphincter of Oddi from April 2017 to December 2022, 42 with the resolution of jaundice (clinical success rate, 95.5%) were retrospectively analyzed. Univariate and multivariate logistic regression analysis identified factors associated with stent patency duration. Results: Univariate analysis revealed significant differences in the drainage method (406 days for unilateral drainage vs. 305 days for bilateral drainage of the right and left liver lobes, p = 0.022) with or without chemotherapy (406 days with vs. 154 days without, p = 0.038). Multivariate analysis (Cox proportional hazards analysis) revealed similar results, with unilateral drainage (p = 0.031) and chemotherapy (p = 0.048) identified as independent factors associated with prolonged stent patency. Early adverse events were observed in two patients (4.8%; one cholangitis, one pancreatitis). Conclusions: Inside-stent therapy was safely performed in patients with malignant hilar biliary obstruction. Simple unilateral drainage and chemotherapy may prolong stent patency.

2.
Acute Med Surg ; 11(1): e980, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39005501

RESUMO

Background: The use of venovenous extracorporeal membrane oxygenation (VV-ECMO), particularly during radiotherapy, for severe malignant central airway obstruction has rarely been reported. Case Presentation: A 47-year-old female presented to our emergency department with severe respiratory distress. Given her medical history, she was initially diagnosed with asthma. Despite initial treatment, which included intubation, her condition deteriorated, necessitating VV-ECMO. Computed tomography performed following the initiation of VV-ECMO revealed extensive lung cancer involving both bronchial types. Radiotherapy while on VV-ECMO led to a significant reduction in tumor size, allowing for the weaning of ECMO support and successful extubation. Conclusion: Malignant central airway obstruction is life-threatening. Our case demonstrates the efficacy of combining VV-ECMO with radiotherapy when conventional therapies fail. Further research is necessary to validate and explore this novel approach's implications.

3.
Gastrointest Endosc ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38964479

RESUMO

BACKGROUND AND AIMS: There is a high incidence of stricture after endoscopic submucosal dissection (ESD) for cervical esophageal cancer. We aimed to elucidate the risk factors for stricture and evaluate the efficacy of steroid injection for stricture prevention in the cervical esophagus. METHODS: We retrospectively analyzed 100 patients who underwent ESD for cervical esophageal cancer to: (1) identify the factors associated with stricture among patients who did not receive steroid injection; (2) compare the incidence of stricture between patients with and without steroid injection. RESULTS: Among 48 patients who did not receive steroid injection, there were significant differences in tumor size (P = .026), resection time (P = .028), and circumferential extent of the mucosal defect (P = .005) between patients with stricture (n = 5) and without stricture (n = 43). Compared with patients without steroid injection, patients with steroid injection had a significantly lower incidence of stricture when the post-ESD mucosal defect was < 3/4 and ≥ 1/2 (40% versus 8%, P = .039). As for the patients with a post-ESD mucosal defect of ≥ 3/4 (n = 13), local steroid injection was performed for all the patients, and 6 patients (46%) developed stricture. CONCLUSIONS: Patients who underwent ≥ 1/2 circumferential resection were at high risk of cervical esophageal stricture. Steroid injection had a stricture-prevention effect in patients with < 3/4 and ≥ 1/2 circumferential resection, but seemed to be insufficient in preventing stricture in patients with ≥ 3/4 circumferential resection.

4.
J Arrhythm ; 40(3): 552-559, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38939776

RESUMO

Background: Atrioventricular nodal reentrant tachycardia (AVNRT) sometimes recurs even after anatomical slow pathway (SP) ablation targeting the rightward inferior extension (RIE). This multicenter study aimed to determine the reasons for AVNRT recurrence. Methods and Results: Forty-six patients were treated successfully for recurrent AVNRT. Initial treatment was for 38 slow-fast AVNRTs, 3 fast-slow AVNRTs, 2 slow-slow AVNRTs, 2 slow-fast and fast-slow AVNRTs, and 1 noninducible AVNRT. All initial treatments were of RF application to the RIE; SP elimination was achieved in 11, dual AVN physiology was seen in 29, and AVNRT remained inducible in 5. The recurrent AVNRTs included 34 slow-fast AVNRTs, 6 fast-slow AVNRTs, 3 slow-slow AVNRTs, 2 slow-fast and fast-slow AVNRTs, and 1 slow-fast and slow-slow AVNRTs. Successful ablation site was within the RIE in 39 and left inferior extension in 7. In 30 of 39, the successful RIE site was in the same area or higher than that of the initial procedure. Conclusion: For a high majority (around 85%) of patients in whom AVNRT recurs after initial ablation success, the site of a second successful procedure will be within the RIE even though the RIE was originally targeted. Furthermore, a high majority (around 86%) of sites of successful ablation will be higher than those originally targeted.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38845191

RESUMO

INTRODUCTION: Transvenous lead extractions (TLEs) for cardiac implantable electronic device complications often encounter difficulties with strong adhesions to the myocardium or vessels. In this report, we introduce a novel "Four-Stage Rocket" technique for effective TLE in cases where conventional methods fail. METHODS AND RESULTS: Two challenging cases where conventional TLE methods failed were treated using a combination of four devices: Needle's Eye Snare, Agilis NxT Steerable Introducer, GlideLight Laser sheath, and GORE® DrySeal Flex Introducer sheath, employed via the inferior vena cava. The "Four-Stage Rocket" technique successfully detached firmly adhered leads near the tricuspid valve annulus, where the traditional superior vena cava approach was inadequate. CONCLUSION: The "Four-Stage Rocket" technique offers a potential alternative in complex TLE cases, aligning the laser direction with the adhesion detachment and reducing the tissue damage risk.

6.
Heart Rhythm ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38759918

RESUMO

BACKGROUND: Novel diamond-embedded catheter enables precise temperature-controlled ablation. However, the effects of contact angle on lesion formation of this catheter are poorly understood. OBJECTIVE: The purpose of this study was to evaluate lesion formation using the temperature-controlled ablation catheter embedded with diamond at different angles in a porcine experimental model. METHODS: Freshly sacrificed porcine hearts were used. Radiofrequency catheter ablation was performed at 50 W for 15 seconds at an upper temperature setting of 60°C. The contact force (5g, 10g, 30g) and catheter contact angles (30°, 45°, 90°) were changed in each set (n = 13 each). Surface width, maximum lesion width, lesion depth, surface area, distance from the distal edge to the widest area, and impedance drop were evaluated. RESULTS: Surface width and maximum lesion width were longer at 30° than at 90° (P <.05). There were no significant differences in the lesion depth by catheter angle except at 30g. Surface area was larger at 30° than at 90° (P <.05). Distance from the distal edge to the widest area was longer at 30° than at 90° (P <.05). There were no significant differences in impedance drop according to catheter angle. CONCLUSION: With diamond-embedded temperature-controlled ablation catheters, lesion width increased at a shallower contact angle, whereas lesion depth did not. Surface area also increased at a shallower contact angle. This catheter created a large ablation lesion on the proximal side of the catheter, which looked like a "honey pot."

7.
J Arrhythm ; 40(2): 349-355, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38586843

RESUMO

Objective: Postoperative pain is a major issue with subcutaneous implantable cardioverter defibrillators (S-ICD). In 2020, we introduced intravenous patient-controlled analgesia (IV-PCA) in addition to the conventional, request-based analgesia for postoperative pain control in S-ICD. To determine the effect and safety, we quantitatively assessed the effect of IV-PCA after S-ICD surgery over conventional methods. Methods: During the study period, a total of 113 consecutive patients (age, 50.1 ± 15.5 years: males, 101) underwent a de novo S-ICD implantation under general anesthesia. While the postoperative pain was addressed with either request-based analgesia (by nonsteroid anti-inflammatory drugs, N = 68, dubbed as "PCA absent") or fentanyl-based IV-PCA in addition to the standard care (N = 45, dubbed as "PCA present"). The degree of postoperative pain from immediately after surgery to 1 week were retrospectively investigated by the numerical rating scale (NRS) divided into four groups at rest and during activity (0: no pain, 1-3: mild pain, 4-6: moderate pain, 7-10: severe pain). Results: Although IV-PCA was removed on Day 1, it was associated with continued better pain control compared to PCA absent group. At rest, the proportion of patients expressing pain (mild or more) was significantly lower in the PCA present group from Day 0 to Day 4. In contrast to at rest, a better pain control continued through the entire study period of 7 days. No serious adverse events were observed. A few patients experienced nausea in both groups and the inter-group difference was not found significant. Conclusion: IV-PCA suppresses postoperative pain in S-ICD without major safety concerns.

9.
J Arrhythm ; 40(1): 83-89, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333410

RESUMO

Background: The role of the pulmonary veins (PVs) as triggers in atrial fibrillation (AF) is well-known; however, their detailed electrophysiological properties have not been thoroughly examined. Objective: This study aimed to investigate the electrophysiological properties of the PVs between paroxysmal AF (pAF) and persistent AF (perAF). Methods: Prior to catheter ablation in patients with pAF (n = 51) and perAF (n = 41), a voltage map of the left atrium and PVs was created under sinus rhythm, and the area of the myocardial sleeves in the PVs and their electrophysiological characteristics, including the pacing threshold and effective refractory period (ERP), were compared between the two groups. Results: Compared with perAF, the myocardial sleeves of PVs for pAF were significantly larger for all PVs. The ERP for perAF was significantly shorter than that for pAF for all PVs. The pacing threshold for perAF was significantly higher than that for pAF for the right and left superior PVs. Conclusion: In patients with perAF, a decrease in the normal myocardial sleeves and a shortening of the ERP were observed for all PVs. Those changes in the electrophysiological properties of the PVs might be related to the persistence of AF.

10.
J Arrhythm ; 40(1): 131-142, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333409

RESUMO

Background: This study aimed to establish a systematic method for diagnosing atrioventricular nodal reentrant tachycardia (AVNRT) with a bystander concealed nodoventricular pathway (cNVP). Methods: We analyzed 13 cases of AVNRT with a bystander cNVP, 11 connected to the slow pathway (cNVP-SP) and two to the fast pathway (cNVP-FP), along with two cases of cNVP-related orthodromic reciprocating tachycardia (ORT). Results: The diagnostic process was summarized in three steps. Step 1 was identification of the presence of an accessory pathway by resetting the tachycardia with delay (n = 9) and termination without atrial capture (n = 4) immediately after delivery of a His-refractory premature ventricular contraction (PVC). Step 2 was exclusion of ORT by atrio-His block during the tachycardia (n = 4), disappearance of the reset phenomenon after the early PVC (n = 7), or dissociation of His from the tachycardia during ventricular overdrive pacing (n = 1). Moreover, tachycardia reset/termination without the atrial capture (n = 2/2) 1 cycle after the His-refractory PVC was specifically diagnostic. Exceptionally, the disappearance of the reset phenomenon was also observed in the two cNVP-ORTs. Step 3 was verification of the AVN as the cNVP insertion site, evidenced by an atrial reset/block preceding the His reset/block in fast-slow AVNRT with a cNVP-SP and slow-fast AVNRT with a cNVP-FP or His reset preceding the atrial reset in slow-fast AVNRT with a cNVP-SP. Conclusion: AVNRT with a bystander cNVP can be diagnosed in the three steps with few exceptions. Notably, tachycardia reset/termination without atrial capture one cycle after delivery of a His-refractory PVC is specifically diagnostic.

12.
J Interv Card Electrophysiol ; 67(1): 147-155, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37311981

RESUMO

BACKGROUND: The lesion index (LSI) helps predict the lesion size and is widely used in ablation of various types of arrhythmias. However, the influence of the ablation settings on the lesion formation and incidence of steam pops under the same LSI value remains unclear. METHODS: Using a contact force (CF) sensing catheter (TactiCath™) in an ex vivo swine left ventricle model, RF lesions were created with a combination of various power steps (30 W, 40 W, 50 W) and CFs (10 g, 20 g, 30 g, 40 g, 50 g) under the same LSI values (5.2 and 7.0). The correlation between the lesion formation and ablation parameters was evaluated. RESULTS: Ninety RF lesions were created under a target LSI value of 5.2, and eighty-four were developed under a target LSI value of 7.0. In the LSI 5.2 group, the resultant lesion size widely varied according to the ablation power, and a multiple regression analysis indicated that the ablation energy delivered was the best predictor of the lesion formation. To create a lesion depth > 4 mm, an ablation energy of 393 J is the best cutoff value, suggesting a possibility that ablation energy may be used as a supplemental marker that better monitors the progress of the lesion formation in an LSI 5.2 ablation. In contrast, such inconsistency was not obvious in the LSI 7.0 group. Compared with 30 W, the 50-W ablation exhibited a higher incidence of steam pops in both the LSI 5.2 and 7.0 groups. CONCLUSIONS: The LSI-lesion size relationship was not necessarily consistent, especially for an LSI of 5.2. To avoid any unintentional, weak ablation, the ablation energy may be a useful supportive parameter (393 J as a cutoff value for a 4-mm depth) during ablation with an LSI around 5.2. Thanks to a prolonged ablation time, the LSI-lesion size relationship is consistent for an LSI of 7.0. However, it is accompanied by a high incidence of steam pops. Care should be given to the ablation settings even when the same LSI value is used.


Assuntos
Ablação por Cateter , Suínos , Animais , Vapor , Ventrículos do Coração/cirurgia , Arritmias Cardíacas/cirurgia
13.
J Interv Card Electrophysiol ; 67(3): 589-597, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37691083

RESUMO

BACKGROUND: Lesion formation during catheter ablation is influenced by the power, contact force (CF), time, and catheter stability. However, the influence of the irrigation effects on lesion formation remains unknown. METHODS: An ex vivo experiment using conductive gel was performed. Using three different catheter designs (TactiFlex ™ SE [TF], IntellaNav MiFi ™ OI [MiFi], QDOT MICRO™ [QDOT]), a cross-sectional analysis of the lesion size and surface lesion type of 10g/40W lesions with a combination of various ablation times was performed in protocol 1. A longitudinal analysis (combination of various powers [30, 40, and 50W] and various ablation times with a 10g setting) was performed to investigate the influence of the auto-regulated irrigation system (QDOT) on lesion formation in protocol 2. RESULTS: The lesion formation with the QDOT catheter tended to create larger ablation lesions, while that with the TF catheter created smaller lesions than the other catheters. The lesion surface characteristics were divided into two patterns: ring (MiFi catheter and QDOT) and crescent (TF) patterns. The auto-regulated irrigation system did not influence the lesion formation, and the relationship between the lesion formation and RF energy exhibited similar changes regardless of the ablation power setting. CONCLUSION: The lesion formation and lesion surface characteristics differed among the different irrigation tip designs. An auto-regulated irrigation system did not affect the lesion creation or surface lesion characteristics. Care should be given to the inter-product differences in the lesion characteristics during RF catheter ablation, partly due to the irrigation flow control and tip design.


Assuntos
Ablação por Cateter , Irrigação Terapêutica , Humanos , Estudos Transversais , Irrigação Terapêutica/métodos , Catéteres , Ablação por Cateter/métodos , Impedância Elétrica , Desenho de Equipamento
14.
Sci Rep ; 13(1): 18875, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37914708

RESUMO

Average beat interval (BI) and beat interval variability (BIV) are primarily determined by mutual entrainment between the autonomic-nervous system (ANS) and intrinsic mechanisms that govern sinoatrial node (SAN) cell function. While basal heart rate is not affected by age in humans, age-dependent reductions in intrinsic heart rate have been documented even in so-called healthy individuals. The relative contributions of the ANS and intrinsic mechanisms to age-dependent deterioration of SAN function in humans are not clear. We recorded ECG on patients (n = 16 < 21 years and n = 23 41-78 years) in the basal state and after ANS blockade (propranolol and atropine) in the presence of propofol and dexmedetomidine anesthesia. Average BI and BIV were analyzed. A set of BIV features were tested to designated the "signatures" of the ANS and intrinsic mechanisms and also the anesthesia "signature". In young patients, the intrinsic mechanisms and ANS mainly contributed to long- and short-term BIV, respectively. In adults, both ANS and intrinsic mechanisms contributed to short-term BIV, while the latter also contributed to long-term BIV. Furthermore, anesthesia affected ANS function in young patients and both mechanisms in adult. The work also showed that intrinsic mechanism features can be calculated from BIs, without intervention.


Assuntos
Atropina , Nó Sinoatrial , Adulto , Humanos , Propranolol , Frequência Cardíaca/fisiologia , Sistema Nervoso Autônomo/fisiologia , Eletrocardiografia
16.
J Cardiovasc Electrophysiol ; 34(9): 2002-2005, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37526239

RESUMO

BACKGROUND: A 70-year-old man revealed a rare type of atrioventricular nodal re-entrant tachycardia (AVNRT) involving distinct retrograde pathways, superior slow pathway, and inferolateral left atrial slow pathway. RESULT: Radiofrequency ablation was successfully performed on the noncoronary cusp and in the left atrium, respectively, to eliminate the tachycardias. DISCUSSION AND CONCLUSION: Due to the anomalous electrical conduction patterns, careful diagnosis and ablation strategies were necessary to avoid the risk of atrioventricular block. These findings underscore the diversity and complexity of AVNRT and highlight the importance of tailored therapeutic approaches.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Masculino , Humanos , Idoso , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Fibrilação Atrial/cirurgia , Eletrocardiografia , Fascículo Atrioventricular , Átrios do Coração
17.
J Gastroenterol ; 58(12): 1178-1187, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37572136

RESUMO

BACKGROUND: Functional dyspepsia (FD) and irritable bowel syndrome (IBS) are caused and exacerbated by consumption of fatty foods. However, no study has evaluated brain activity in response to food images in patients with disorders of gut-brain interaction (DGBI). This study aimed to compare food preference and brain activity when viewing food images between patients with DGBI and healthy controls. METHODS: FD and IBS were diagnosed using the ROME IV criteria. Food preference was assessed using a visual analog scale (VAS). Brain activity in the prefrontal cortex (PFC) in response to food images was investigated using functional near-infrared spectroscopy (fNIRS). RESULTS: Forty-one patients were enrolled, including 25 with DGBI. The mean VAS scores for all foods (controls vs. FD vs. IBS: 69.1 ± 3.3 vs. 54.8 ± 3.8 vs. 62.8 ± 3.7, p = 0.02), including fatty foods (78.1 ± 5.4 vs. 43.4 ± 6.3 vs. 64.7 ± 6.1, p < 0.01), were the lowest in patients with FD among all groups. Patients with FD had significantly higher brain activity in the left PFC than those with IBS and healthy controls (mean z-scores in controls vs. FD vs. IBS: - 0.077 ± 0.03 vs. 0.125 ± 0.04 vs. - 0.002 ± 0.03, p < 0.001). CONCLUSIONS: Patients with DGBI, particularly those with FD, disliked fatty foods. The brain activity in patients with DGBI differed from that in healthy controls. Increased activity in the PFC of patients with FD was confirmed.


Assuntos
Dispepsia , Síndrome do Intestino Irritável , Humanos , Dispepsia/diagnóstico por imagem , Síndrome do Intestino Irritável/diagnóstico por imagem , Alimentos , Medição da Dor , Encéfalo/diagnóstico por imagem
18.
Artigo em Inglês | MEDLINE | ID: mdl-37561371

RESUMO

The subclavian vein is typically used in cardiovascular implantable electronic device (CIED) implantations. External stress on the subclavian vein can lead to lead-related complications. There are several causes of this stress, such as frequent upper extremity movements or external injury. Venous thoracic outlet syndrome (TOS) can also become the cause of external lead stress. However, the diagnosis of venous TOS can be challenging because subclavian venography can appear normal at first glance. We present a unique case of a device infection in a patient with venous TOS. A careful observation of the imaging studies is vital for diagnosing venous TOS and a leadless pacemaker implantation could be an alternative therapeutic option.

19.
Plant Cell Physiol ; 64(10): 1167-1177, 2023 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-37498972

RESUMO

Plant seedlings adjust the growth of the hypocotyl in response to surrounding environmental changes. Genetic studies have revealed key players and pathways in hypocotyl growth, such as phytohormones and light signaling. However, because of genetic redundancy in the genome, it is expected that not-yet-revealed mechanisms can be elucidated through approaches different from genetic ones. Here, we identified a small compound, HYGIC (HG), that simultaneously induces hypocotyl elongation and thickening, accompanied by increased nuclear size and enlargement of cortex cells. HG-induced hypocotyl growth required the ethylene signaling pathway activated by endogenous ethylene, involving CONSTITUTIVE PHOTOMORPHOGENIC 1, ETHYLENE INSENSITIVE 2 (EIN2) and redundant transcription factors for ethylene responses, ETHYLENE INSENSITIVE 3 (EIN3) and EIN3 LIKE 1. By using EBS:GUS, a transcriptional reporter of ethylene responses based on an EIN3-binding-cis-element, we found that HG treatment ectopically activates ethylene responses at the epidermis and cortex of the hypocotyl. RNA-seq and subsequent gene ontology analysis revealed that a significant number of HG-induced genes are related to responses to hypoxia. Indeed, submergence, a representative environment where the hypoxia response is induced in nature, promoted ethylene-signaling-dependent hypocotyl elongation and thickening accompanied by ethylene responses at the epidermis and cortex, which resembled the HG treatment. Collectively, the identification and analysis of HG revealed that ectopic responsiveness to ethylene promotes hypocotyl growth, and this mechanism is activated under submergence.


Assuntos
Proteínas de Arabidopsis , Arabidopsis , Hipocótilo/metabolismo , Proteínas de Ligação a DNA/metabolismo , Proteínas de Arabidopsis/genética , Proteínas de Arabidopsis/metabolismo , Arabidopsis/metabolismo , Transdução de Sinais/fisiologia , Etilenos/farmacologia , Etilenos/metabolismo , Hipóxia , Regulação da Expressão Gênica de Plantas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA