Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Diabetes Complications ; 37(5): 108470, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37043984

RESUMO

AIMS/HYPOTHESIS: We investigated associations among glucose time in range (TIR, 70-180 mg/dL), glycemic markers and prevalence of diabetic microangiopathy in people with diabetes undergoing hemodialysis (HD). METHODS: A total of 107 people with type 2 diabetes undergoing HD (HbA1c 6.4 %; glycated albumin [GA] 20.6 %) using continuous glucose monitoring were analyzed in this observational and cross-sectional study. RESULTS: HbA1c and GA levels significantly negatively correlated with TIR, and positively correlated with time rate of hyperglycemia, but not with time rate of hypoglycemia. TIR of 70 % corresponded to HbA1c of 6.5 % and GA of 21.2 %. The estimated HbA1c level corresponding to TIR of 70 % in this study was lower than that previously reported in people with diabetes without HD. The prevalence of diabetic neuropathy was not significantly different between people with TIR ≥ 70 % and those with TIR < 70 % (P = 0.1925), but the prevalence of diabetic retinopathy in people with TIR ≥ 70 % was significantly lower than in those with TIR < 70 % (P = 0.0071). CONCLUSION/INTERPRETATION: TIR correlated with HbA1c and GA levels in people with type 2 diabetes on HD. Additionally, a higher TIR resulted in a lower rate of diabetic retinopathy. RESEARCH IN CONTEXT: What is already known about this subject? What is the key question? What are the new findings? How might this impact on clinical practice in the foreseeable future?


Assuntos
Diabetes Mellitus Tipo 2 , Retinopatia Diabética , Doenças Vasculares , Humanos , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/epidemiologia , Glicemia , Albumina Sérica Glicada , Automonitorização da Glicemia , Hemoglobinas Glicadas , Retinopatia Diabética/epidemiologia , Estudos Transversais , Produtos Finais de Glicação Avançada , Diálise Renal/efeitos adversos , Albumina Sérica
2.
Hypertens Res ; 45(12): 1977-1985, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35689092

RESUMO

Although the renin-angiotensin-aldosterone system plays a crucial role in fluid homeostasis and cardiovascular disease pathophysiology, measurements of plasma prorenin levels are still unavailable in clinical practice. We previously found that prorenin molecules in human blood underwent significant posttranslational modifications and were undetectable using immunological assays that utilized antibodies specifically recognizing unmodified recombinant prorenin. Using a sandwich enzyme-linked immunosorbent assay that captures posttranslationally modified prorenins with their prosegment antibodies, we measured plasma and serum prorenin concentrations in 219 patients with diabetes mellitus, hypertension and/or renal disease and compared them with those of 40 healthy controls. The measured values were not significantly different from those of the healthy controls and were 1,000- to 100,000-fold higher than previously reported levels determined using conventional assay kits. Multiple regression analyses showed that body weight, serum albumin levels, and serum creatinine levels negatively correlated with plasma prorenin levels, while the use of loop diuretics was associated with elevated plasma prorenin levels. Blood pressure, HbA1c, and plasma renin activity were not independent variables affecting plasma prorenin levels. In contrast, serum prorenin levels were unaffected by any of the above clinical parameters. The association of the plasma prorenin concentration with indices reflecting body fluid status suggests the need to scrutinize its role as a biomarker, while serum prorenins are less likely to have immediate diagnostic value.


Assuntos
Diabetes Mellitus , Hipertensão , Nefropatias , Humanos , Renina , Precursores Enzimáticos/metabolismo , Sistema Renina-Angiotensina/fisiologia
3.
Diabetes Care ; 44(7): 1647-1656, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34045240

RESUMO

OBJECTIVE: There is a high risk of asymptomatic hypoglycemia associated with hemodialysis (HD) using glucose-free dialysate; therefore, the inclusion of glucose in the dialysate is believed to prevent intradialytic hypoglycemia. However, the exact glycemic fluctuation profiles and frequency of asymptomatic hypoglycemia using dialysates containing >100 mg/dL glucose have not been determined. RESEARCH DESIGN AND METHODS: We evaluated the glycemic profiles of 98 patients, 68 of whom were men, with type 2 diabetes undergoing HD (HbA1c 6.4 ± 1.2%; glycated albumin 20.8 ± 6.8%) with a dialysate containing 100, 125, or 150 mg/dL glucose using continuous glucose monitoring. RESULTS: Sensor glucose level (SGL) showed a sustained decrease during HD, irrespective of the dialysate glucose concentration, and reached a nadir that was lower than the dialysate glucose concentration in 49 participants (50%). Twenty-one participants (21%) presented with HD-related hypoglycemia, defined by an SGL <70 mg/dL during HD and/or between the end of HD and their next meal. All these hypoglycemic episodes were asymptomatic. Measures of glycemic variability calculated using the SGL data (SD, coefficient of variation, and range of SGL) were higher and time below range (<70 mg/dL) was lower in participants who experienced HD-related hypoglycemia than in those who did not, whereas time in range between 70 and 180 mg/dL, time above range (>180 mg/dL), HbA1c, and glycated albumin of the two groups were similar. CONCLUSIONS: Despite the use of dialysate containing 100-150 mg/dL glucose, patients with diabetes undergoing HD experienced HD-related hypoglycemia unawareness frequently. SGL may fall well below the dialysate glucose concentration toward the end of HD.


Assuntos
Diabetes Mellitus Tipo 2 , Hipoglicemia , Glicemia , Automonitorização da Glicemia , Glucose , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/etiologia , Hipoglicemiantes , Masculino , Diálise Renal/efeitos adversos
4.
Ther Apher Dial ; 25(5): 586-594, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33403763

RESUMO

FreeStyle Libre has been approved for use in patients undergoing hemodialysis (HD) in Japan, unlike Europe and the United States; however, evidence regarding its accuracy in such patients is sparse. Forty-one participants with type 2 diabetes undergoing HD were recruited. The overall mean absolute relative difference and mean absolute difference were 23.4% and 33.9 mg/dL, respectively. Sensor glucose levels and capillary glucose levels were significantly correlated (r = 0.858, P < .01), although the sensor glucose levels were significantly lower than the capillary glucose levels. The accuracy of FreeStyle Libre in patients undergoing HD became deteriorated with the days of usage. The percentage of sensor results in Zones A and B in the consensus error grid analysis and in the Clarke error grid analysis were 99.7% and 99.0%, respectively. Its insufficient accuracy necessitates adjunct usage of FreeStyle Libre with self-monitoring of blood glucose in patients undergoing HD.


Assuntos
Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 2/sangue , Diálise Renal , Idoso , Feminino , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes
5.
J Diabetes Complications ; 34(11): 107680, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32736927

RESUMO

INTRODUCTION: We evaluated the accuracy and clinical utility of flash glucose monitoring (FGM) in comparison with continuous glucose monitoring (CGM) and self-monitoring blood glucose (SMBG) in patients with type 2 diabetes (T2D) undergoing hemodialysis (HD). METHODS: Simultaneous FGM (FreeStyle LibrePro), CGM (iPro2) and SMBG were performed on 13 T2D research subjects. RESULTS: There were good overall correlations between SMBG and FGM (64.7% and 30.8% within the A and B of Parkes Error Grid, respectively) and between SMBG and CGM (87.9% and 11.0% within the A and B, respectively). However, during HD, correlations between SMBG and FGM were only 49.7% and 37.2% within the A and B, respectively, while correlations of SMBG and CGM were 72.8% and 22.2% within the A and B, respectively. The percentage of FGM not in Zone A + B was more than 4 times higher than for CGM. The overall mean absolute relative difference (MARD) for FGM was 18.2%, this significantly higher than 11.2% for CGM. During HD, MARD for FGM was 22.8%, significantly higher than 15.0% for CGM. CONCLUSION: FGM has good clinical agreement in T2D patients undergoing HD. However, the accuracy of FGM relative to SMBG was worse than that of CGM.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 2 , Diálise Renal , Glicemia/análise , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 2/complicações , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA