RESUMO
OBJECTIVES: This study aims to assess the effectiveness of super-resolution deep-learning-based reconstruction (SR-DLR), which leverages k-space data, on the image quality of lumbar spine magnetic resonance (MR) bone imaging using a 3D multi-echo in-phase sequence. MATERIALS AND METHODS: In this retrospective study, 29 patients who underwent lumbar spine MRI, including an MR bone imaging sequence between January and April 2023, were analyzed. Images were reconstructed with and without SR-DLR (Matrix sizes: 960 × 960 and 320 × 320, respectively). The signal-to-noise ratio (SNR) of the vertebral body and spinal canal and the contrast and contrast-to-noise ratio (CNR) between the vertebral body and spinal canal were quantitatively evaluated. Furthermore, the slope at half-peak points of the profile curve drawn across the posterior border of the vertebral body was calculated. Two radiologists independently assessed image noise, contrast, artifacts, sharpness, and overall image quality of both image types using a 4-point scale. Interobserver agreement was evaluated using weighted kappa coefficients, and quantitative and qualitative scores were compared via the Wilcoxon signed-rank test. RESULTS: SNRs of the vertebral body and spinal canal were notably improved in images with SR-DLR (p < 0.001). Contrast and CNR were significantly enhanced with SR-DLR compared to those without SR-DLR (p = 0.023 and p = 0.022, respectively). The slope of the profile curve at half-peak points across the posterior border of the vertebral body and spinal canal was markedly higher with SR-DLR (p < 0.001). Qualitative scores (noise: p < 0.001, contrast: p < 0.001, artifact p = 0.042, sharpness: p < 0.001, overall image quality: p < 0.001) were superior in images with SR-DLR compared to those without. Kappa analysis indicated moderate to good agreement (noise: κ = 0.56, contrast: κ = 0.51, artifact: κ = 0.46, sharpness: κ = 0.76, overall image quality: κ = 0.44). CONCLUSION: SR-DLR, which is based on k-space data, has the potential to enhance the image quality of lumbar spine MR bone imaging utilizing a 3D gradient echo in-phase sequence. CLINICAL RELEVANCE STATEMENT: The application of SR-DLR can lead to improvements in lumbar spine MR bone imaging quality.
Assuntos
Aprendizado Profundo , Vértebras Lombares , Imageamento por Ressonância Magnética , Humanos , Feminino , Vértebras Lombares/diagnóstico por imagem , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Idoso , Adulto , Razão Sinal-Ruído , Imageamento Tridimensional/métodos , Idoso de 80 Anos ou mais , Doenças da Coluna Vertebral/diagnóstico por imagemRESUMO
To assess the diagnostic performance of unenhanced electrocardiogram (ECG)-gated cardiac computed tomography (CT) for detecting myocardial edema, using MRI T2 mapping as the reference standard. This retrospective study protocol was approved by our institutional review board, which waived the requirement for written informed consent. Between December 2017 to February 2019, consecutive patients who had undergone T2 mapping for myocardial tissue characterization were identified. We excluded patients who did not undergo unenhanced ECG-gated cardiac CT within 3 months from MRI T2 mapping or who had poor CT image quality. All patients underwent unenhanced ECG-gated cardiac CT with an axial scan using a third-generation, 320â ×â 0.5 mm detector-row CT unit. Two radiologists together drew regions of interest (ROIs) in the interventricular septum on the unenhanced ECG-gated cardiac CT images. Using T2 mapping as the reference standard, the diagnostic performance of unenhanced cardiac CT for detecting myocardial edema was evaluated by using the area under the receiver operating characteristic curve with sensitivity and specificity. Youden index was used to find an optimal sensitivity-specificity cutoff point. A cardiovascular radiologist independently performed the measurements, and interobserver reliability was assessed using intraclass correlation coefficients for CT value measurements. A P value of <.05 was considered statistically significant. We included 257 patients who had undergone MRI T2 mapping. Of the 257 patients, 35 patients underwent unenhanced ECG-gated cardiac CT. One patient was excluded from the study because of poor CT image quality. Finally, 34 patients (23 men; age 64.7â ±â 14.6 years) comprised our study group. Using T2 mapping, we identified myocardial edema in 19 patients. Mean CT and T2 values for 34 patients were 46.3â ±â 2.7 Hounsfield unit and 49.0â ±â 4.9 ms, respectively. Mean CT values moderately correlated with mean T2 values (Rhoâ =â -0.41; Pâ <â .05). Mean CT values provided a sensitivity of 63.2% and a specificity of 93.3% for detecting myocardial edema, with a cutoff value of ≤45.0 Hounsfield unit (area under the receiver operating characteristic curveâ =â 0.77; Pâ <â .01). Inter-observer reproducibility in measuring mean CT values was excellent (intraclass correlation coefficientâ =â 0.93; [95% confidence interval: 0.86, 0.96]). Myocardial edema could be detected by CT value of myocardium in unenhanced ECG-gated cardiac CT.
Assuntos
Eletrocardiografia , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Eletrocardiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Edema/diagnóstico por imagem , Edema Cardíaco/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca/métodos , Curva ROC , AdultoRESUMO
PURPOSE: We aimed to evaluate the effect of deep learning-based reconstruction (DLR) on high-spatial-resolution three-dimensional T2-weighted fast asymmetric spin-echo (HR-3D T2-FASE) imaging in the preoperative evaluation of cerebellopontine angle (CPA) tumors. METHODS: This study included 13 consecutive patients who underwent preoperative HR-3D T2-FASE imaging using a 3 T MRI scanner. The reconstruction voxel size of HR-3D T2-FASE imaging was 0.23 × 0.23 × 0.5 mm. The contrast-to-noise ratios (CNRs) of the structures were compared between HR-3D T2-FASE images with and without DLR. The observers' preferences based on four categories on the tumor side on HR-3D T2-FASE images were evaluated. The facial nerve in relation to the tumor on HR-3D T2-FASE images was assessed with reference to intraoperative findings. RESULTS: The mean CNR between the tumor and trigeminal nerve and between the cerebrospinal fluid and trigeminal nerve was significantly higher for DLR images than non-DLR-based images (14.3 ± 8.9 vs. 12.0 ± 7.6, and 66.4 ± 12.0 vs. 53.9 ± 8.5, P < 0.001, respectively). The observer's preference for the depiction and delineation of the tumor, cranial nerves, vessels, and location relation on DLR HR-3D T2FASE images was superior to that on non-DLR HR-3D T2FASE images in 7 (54%), 6 (46%), 6 (46%), and 6 (46%) of 13 cases, respectively. The facial nerves around the tumor on HR-3D T2-FASE images were visualized accurately in five (38%) cases with DLR and in four (31%) without DLR. CONCLUSION: DLR HR-3D T2-FASE imaging is useful for the preoperative assessment of CPA tumors.
Assuntos
Aprendizado Profundo , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Cuidados Pré-Operatórios , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Cuidados Pré-Operatórios/métodos , Idoso , Ângulo Cerebelopontino/diagnóstico por imagem , Ângulo Cerebelopontino/cirurgia , Neoplasias Cerebelares/diagnóstico por imagem , Neoplasias Cerebelares/cirurgia , Interpretação de Imagem Assistida por Computador/métodos , Estudos Retrospectivos , Neuroma Acústico/diagnóstico por imagem , Neuroma Acústico/cirurgiaRESUMO
OBJECTIVE: The aim of this study was to assess the utility of the combined use of 3D wheel sampling and deep learning-based reconstruction (DLR) for intracranial high-resolution (HR)-time-of-flight (TOF)-magnetic resonance angiography (MRA) at 3 T. METHODS: This prospective study enrolled 20 patients who underwent head MRI at 3 T, including TOF-MRA. We used 3D wheel sampling called "fast 3D" and DLR for HR-TOF-MRA (spatial resolution, 0.39 × 0.59 × 0.5 mm 3 ) in addition to conventional MRA (spatial resolution, 0.39 × 0.89 × 1 mm 3 ). We compared contrast and contrast-to-noise ratio between the blood vessels (basilar artery and anterior cerebral artery) and brain parenchyma, full width at half maximum in the P3 segment of the posterior cerebral artery among 3 protocols. Two board-certified radiologists evaluated noise, contrast, sharpness, artifact, and overall image quality of 3 protocols. RESULTS: The contrast and contrast-to-noise ratio of fast 3D-HR-MRA with DLR are comparable or higher than those of conventional MRA and fast 3D-HR-MRA without DLR. The full width at half maximum was significantly lower in fast 3D-MRA with and without DLR than in conventional MRA ( P = 0.006, P < 0.001). In qualitative evaluation, fast 3D-MRA with DLR had significantly higher sharpness and overall image quality than conventional MRA and fast 3D-MRA without DLR (sharpness: P = 0.021, P = 0.001; overall image quality: P = 0.029, P < 0.001). CONCLUSIONS: The combination of 3D wheel sampling and DLR can improve visualization of arteries in intracranial TOF-MRA.
Assuntos
Aprendizado Profundo , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Feminino , Estudos Prospectivos , Imageamento Tridimensional/métodos , Pessoa de Meia-Idade , Adulto , Idoso , Processamento de Imagem Assistida por Computador/métodosRESUMO
PURPOSE: The aim of this study is to assess the effect of super-resolution deep learning-based reconstruction (SR-DLR), which uses k-space properties, on image quality of intracranial time-of-flight (TOF) magnetic resonance angiography (MRA) at 3 T. METHODS: This retrospective study involved 35 patients who underwent intracranial TOF-MRA using a 3-T MRI system with SR-DLR based on k-space properties in October and November 2022. We reconstructed MRA with SR-DLR (matrix = 1008 × 1008) and MRA without SR-DLR (matrix = 336 × 336). We measured the signal-to-noise ratio (SNR), contrast, and contrast-to-noise ratio (CNR) in the basilar artery (BA) and the anterior cerebral artery (ACA) and the sharpness of the posterior cerebral artery (PCA) using the slope of the signal intensity profile curve at the half-peak points. Two radiologists evaluated image noise, artifacts, contrast, sharpness, and overall image quality of the two image types using a 4-point scale. We compared quantitative and qualitative scores between images with and without SR-DLR using the Wilcoxon signed-rank test. RESULTS: The SNRs, contrasts, and CNRs were all significantly higher in images with SR-DLR than those without SR-DLR (p < 0.001). The slope was significantly greater in images with SR-DLR than those without SR-DLR (p < 0.001). The qualitative scores in MRAs with SR-DLR were all significantly higher than MRAs without SR-DLR (p < 0.001). CONCLUSION: SR-DLR with k-space properties can offer the benefits of increased spatial resolution without the associated drawbacks of longer scan times and reduced SNR and CNR in intracranial MRA.
Assuntos
Aprendizado Profundo , Angiografia por Ressonância Magnética , Humanos , Angiografia por Ressonância Magnética/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador/métodosRESUMO
PURPOSE: The purpose of this study is to evaluate the influence of super-resolution deep learning-based reconstruction (SR-DLR), which utilizes k-space data, on the quality of images and the quantitation of the apparent diffusion coefficient (ADC) for diffusion-weighted images (DWI) in brain magnetic resonance imaging (MRI). METHODS: A retrospective analysis was performed on 34 patients who had undergone DWI using a 3 T MRI system with SR-DLR reconstruction based on k-space data in August 2022. DWI was reconstructed with SR-DLR (Matrix = 684 × 684) and without SR-DLR (Matrix = 228 × 228). Measurements were made of the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) in white matter (WM) and grey matter (GM), and the full width at half maximum (FWHM) of the septum pellucidum. Two radiologists assessed image noise, contrast, artifacts, blur, and the overall quality of three image types using a four-point scale. Quantitative and qualitative scores between images with and without SR-DLR were compared using the Wilcoxon signed-rank test. RESULTS: Images with SR-DLR showed significantly higher SNRs and CNRs than those without SR-DLR (p < 0.001). No statistically significant variances were found in the apparent diffusion coefficients (ADCs) in WM and GM between images with and without SR-DLR (ADC in WM, p = 0.945; ADC in GM, p = 0.235). Moreover, the FWHM without SR-DLR was notably lower compared to that with SR-DLR (p < 0.001). CONCLUSION: SR-DLR has the potential to augment the quality of DWI in DL MRI scans without significantly impacting ADC quantitation.
RESUMO
PURPOSE: To evaluate the image quality of the combined technique of compressed sensitivity encoding (CS) and spiral imaging in time-of-flight magnetic resonance angiography (TOF-MRA), which is approximately 2.5 times faster than conventional methods. METHODS: Twenty volunteers underwent four TOF-MRA sequences: sensitivity encoding (SENSE) with acceleration factor of 4 (acquisition time: 4:55 min), CS with acceleration factor of 10.9, and spiral and CS-spiral (both 1:55 min). A quantitative image analysis (signal-to-noise ratio [SNR], contrast, and full width at half maximum [FWHM] edge criterion measurements) was performed on four TOF sequences. For qualitative image analysis, two board-certified radiologists evaluated the overall depiction of the proximal, intermediate, and distal branches in CS, spiral, and CS-spiral images using SENSE as a reference. RESULTS: The SNR of BA in spiral and CS-spiral imaging was significantly lower than that in SENSE (p = 0.009). The contrasts of ACA and BA in CS-spiral were significantly higher and those in spiral were significantly lower than those in SENSE (p < 0.001). The FWHM in the CS image was significantly higher than that of SENSE; however, no significant differences were observed between the spiral or CS-spiral and SENSE. In qualitative analysis, the depiction of proximal vascular branches was significantly impaired in spiral than in others and that of distal vascular branches was significantly impaired in CS than in others (p < 0.001). CONCLUSIONS: In TOF-MRA, which is approximately 2.5 times faster than conventional methods, the combined use of CS and spiral imaging demonstrated an improvement in image quality compared to either CS or spiral imaging alone. SUMMARY STATEMENT: The image quality of Compressed SENSE and spiral imaging is particularly poor in the proximal and distal vascular branches, respectively at an extremely high acceleration factor; however, CS-spiral provided stable image quality in all regions as compared with the SENSE technique.
Assuntos
Imageamento Tridimensional , Angiografia por Ressonância Magnética , Humanos , Angiografia por Ressonância Magnética/métodos , Razão Sinal-Ruído , Imageamento Tridimensional/métodos , Imageamento por Ressonância MagnéticaRESUMO
OBJECTIVES: As a novel follow-up method for intracranial aneurysms treated with stent-assisted coil embolization (SACE), we developed four-dimensional magnetic resonance angiography (MRA) with minimized acoustic noise utilizing ultrashort-echo time (4D mUTE-MRA). We aimed to assess whether 4D mUTE-MRA is useful for the evaluation of intracranial aneurysms treated with SACE. METHODS: This study included 31 consecutive patients with intracranial aneurysm treated with SACE who underwent 4D mUTE-MRA at 3 T and digital subtraction angiography (DSA). For 4D mUTE-MRA, five dynamic MRA images with a spatial resolution of 0.5 × 0.5 × 0.5 mm3 were obtained every 200 ms. Two readers independently reviewed the 4D mUTE-MRA images to evaluate the aneurysm occlusion status (total occlusion, residual neck, and residual aneurysm) and the flow in the stent using a 4-point scale (from 1 [not visible] to 4 [excellent]). The interobserver and intermodality agreement was assessed using κ statistics. RESULTS: On DSA images, 10 aneurysms were classified as total occlusion, 14 as residual neck, and 7 as residual aneurysm. In terms of aneurysm occlusion status, the intermodality and interobserver agreement was excellent (κ = 0.92 and κ = 0.96, respectively). For the flow in the stents on 4D mUTE-MRA, the mean score was significantly higher for single stents than multiple stents (p < .001) and for open-cell type stents than closed-cell type (p < .01). CONCLUSIONS: 4D mUTE-MRA is a useful tool with a high spatial and temporal resolution for the evaluation of intracranial aneurysms treated with SACE. KEY POINTS: ⢠In the evaluation of intracranial aneurysms treated with SACE on 4D mUTE-MRA and DSA, the intermodality and interobserver agreement in aneurysm occlusion status was excellent. ⢠4D mUTE-MRA shows good to excellent visualization of flow in the stents, especially for cases treated with a single or open-cell stent. ⢠4D mUTE-MRA can provide hemodynamic information related to embolized aneurysms and the distal arteries to stented parent arteries.
Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Seguimentos , Embolização Terapêutica/métodos , Angiografia por Ressonância Magnética/métodos , Stents , Angiografia Digital/métodos , Resultado do TratamentoRESUMO
Purpose: To evaluate the diagnostic performance of myocardium-to-lumen R1 (1/T1) ratio on postcontrast T1 maps for the detection of cardiac amyloidosis in a large patient sample. Materials and Methods: This retrospective study included consecutive patients who underwent MRI-derived extracellular volume fraction (MRI ECV) analysis between March 2017 and July 2021 because of known or suspected heart failure or cardiomyopathy. Pre- and postcontrast T1 maps were generated using the modified Look-Locker inversion recovery sequence. Diagnostic performances of MRI ECV and myocardium-to-lumen R1 ratio on postcontrast T1 maps (a simplified index not requiring a native T1 map and hematocrit level data) for detecting cardiac amyloidosis were evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. Results: Of 352 patients (mean age, 63 years ± 16 [SD]; 235 men), 136 had cardiac amyloidosis. MRI ECV showed 89.0% (121 of 136; 95% CI: 82%, 94%) sensitivity and 98.6% (213 of 216; 95% CI: 96%, 100%) specificity for helping detect cardiac amyloidosis (cutoff value of 40% [AUC, 0.99 {95% CI: 0.97, 1.00}; P < .001]). Postcontrast myocardium-to-lumen R1 ratio showed 92.6% (126 of 136; 95% CI: 89%, 96%) sensitivity and 93.1% (201 of 216; 95% CI: 89%, 96%) specificity (cutoff value of 0.84 [AUC, 0.98 {95% CI: 0.95, 0.99}; P < .001]). There was no evidence of a difference in AUCs for each parameter (P = .10). Conclusion: Postcontrast myocardium-to-lumen R1 ratio showed excellent diagnostic performance comparable to that of MRI ECV in the detection of cardiac amyloidosis.Keywords: MR Imaging, Cardiac, Heart, Cardiomyopathies Supplemental material is available for this article. © RSNA, 2023.
RESUMO
OBJECTIVES: To evaluate the image quality of the 3D hybrid profile order technique and deep-learning-based reconstruction (DLR) for 3D magnetic resonance cholangiopancreatography (MRCP) within a single breath-hold (BH) at 3 T magnetic resonance imaging (MRI). METHODS: This retrospective study included 32 patients with biliary and pancreatic disorders. BH images were reconstructed with and without DLR. The signal-to-noise ratio (SNR), contrast, contrast-to-noise ratio (CNR) between the common bile duct (CBD) and periductal tissues, and full width at half maximum (FWHM) of CBD on 3D-MRCP were evaluated quantitatively. Two radiologists scored image noise, contrast, artifacts, blur, and overall image quality of the three image types using a 4-point scale. Quantitative and qualitative scores were compared using the Friedman test and post hoc Nemenyi test. RESULTS: The SNR and CNR were not significantly different when under respiratory gating- and BH-MRCP without DLR. However, they were significantly higher under BH with DLR than under respiratory gating (SNR, p = 0.013; CNR, p = 0.027). The contrast and FWHM of MRCP under BH with and without DLR were lower than those under respiratory gating (contrast, p < 0.001; FWHM, p = 0.015). Qualitative scores for noise, blur, and overall image quality were higher under BH with DLR than those under respiratory gating (blur, p = 0.003; overall, p = 0.008). CONCLUSIONS: The combination of the 3D hybrid profile order technique and DLR is useful for MRCP within a single BH and does not lead to the deterioration of image quality and space resolution at 3 T MRI. CLINICAL RELEVANCE STATEMENT: Considering its advantages, this sequence might become the standard protocol for MRCP in clinical practice, at least at 3.0 T. KEY POINTS: ⢠The 3D hybrid profile order can achieve MRCP within a single breath-hold without a decrease in spatial resolution. ⢠The DLR significantly improved the CNR and SNR of BH-MRCP. ⢠The 3D hybrid profile order technique with DLR reduces the deterioration of image quality in MRCP within a single breath-hold.
Assuntos
Colangiopancreatografia por Ressonância Magnética , Aprendizado Profundo , Humanos , Colangiopancreatografia por Ressonância Magnética/métodos , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodosRESUMO
The purpose of this study was to clarify the appropriate use of a combination of pulse sequences and acoustic noise reduction technology in general-purpose brain magnetic resonance imaging. Five pulse sequences commonly used in brain magnetic resonance imaging examinations-turbo spin-echo T2-weighted imaging, T1-weighted fluid-attenuated inversion recovery, T2-weighted fluid-attenuated inversion recovery, diffusion-weighted imaging, and magnetic resonance angiography-were performed on healthy participants at three vendors where acoustic noise reduction technology was available. The results showed that acoustic noise reduction technology reduced sound pressure levels and altered image quality in all pulse sequences across all vendors' magnetic resonance imaging scanners. Although T2-weighted imaging and T1-weighted fluid-attenuated inversion recovery resulted in little image quality degradation, T2-weighted fluid-attenuated inversion recovery, diffusion-weighted imaging, and magnetic resonance angiography had significant image degradation. Therefore, acoustic noise reduction technology should be used with caution.
Assuntos
Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/patologia , Angiografia por Ressonância Magnética , AcústicaRESUMO
OBJECTIVE: For compressed sensing (CS) to become widely used in routine magnetic resonance imaging (MRI), it is essential to improve image quality. This study aimed to evaluate the usefulness of combining CS and deep learning-based reconstruction (DLR) for various sequences in shoulder MRI. METHODS: This retrospective study included 37 consecutive patients who underwent undersampled shoulder MRIs, including T1-weighted (T1WI), T2-weighted (T2WI), and fat-saturation T2-weighted (FS-T2WI) images. Images were reconstructed using the conventional wavelet-based denoising method (wavelet method) and a combination of wavelet and DLR-based denoising methods (hybrid-DLR method) for each sequence. The signal-to-noise ratio and contrast-to-noise ratio of the bone, muscle, and fat and the full width at half maximum of the shoulder joint were compared between the 2 image types. In addition, 2 board-certified radiologists scored the image noise, contrast, sharpness, artifacts, and overall image quality of the 2 image types on a 4-point scale. RESULTS: The signal-to-noise ratios and contrast-to-noise ratios of the bone, muscle, and fat in T1WI, T2WI, and FS-T2WI obtained from the hybrid-DLR method were significantly higher than those of the conventional wavelet method ( P < 0.001). However, there were no significant differences in the full width at half maximum of the shoulder joint in any of the sequences ( P > 0.05). Furthermore, in all sequences, the mean scores of the image noise, sharpness, artifacts, and overall image quality were significantly higher in the hybrid-DLR method than in the wavelet method ( P < 0.001), but there were no significant differences in contrast among the sequences ( P > 0.05). CONCLUSIONS: The DLR denoising method can improve the image quality of CS in T1-weighted images, T2-weighted images, and fat-saturation T2-weighted images of the shoulder compared with the wavelet denoising method alone.
Assuntos
Aprendizado Profundo , Articulação do Ombro , Humanos , Ombro/diagnóstico por imagem , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Articulação do Ombro/diagnóstico por imagemRESUMO
Cigarette smoking is a major risk factor for atherosclerosis. We previously reported that DNA damage was accumulated in atherosclerotic plaque, and was increased in human mononuclear cells by smoking. As vascular endothelial cells are known to modulate inflammation, we investigated the mechanism by which smoking activates innate immunity in endothelial cells focusing on DNA damage. Furthermore, we sought to characterize the plasma level of cell-free DNA (cfDNA), a result of mitochondrial and/or genomic DNA damage, as a biomarker for atherosclerosis. Cigarette smoke extract (CSE) increased DNA damage in the nucleus and mitochondria in human endothelial cells. Mitochondrial damage induced minority mitochondrial outer membrane permeabilization, which was insufficient for cell death but instead led to nuclear DNA damage. DNA fragments, derived from the nucleus and mitochondria, were accumulated in the cytosol, and caused a persistent increase in IL-6 mRNA expression via the cyclic GMP-AMP synthase (cGAS)-stimulator of interferon genes (STING) pathway. cfDNA, quantified with quantitative PCR in culture medium was increased by CSE. Consistent with in vitro results, plasma mitochondrial cfDNA (mt-cfDNA) and nuclear cfDNA (n-cfDNA) were increased in young healthy smokers compared with age-matched nonsmokers. Additionally, both mt-cfDNA and n-cfDNA were significantly increased in patients with atherosclerosis compared with the normal controls. Our multivariate analysis revealed that only mt-cfDNA predicted the risk of atherosclerosis. In conclusion, accumulated cytosolic DNA caused by cigarette smoke and the resultant activation of the cGAS-STING pathway may be a mechanism of atherosclerosis development. The plasma level of mt-cfDNA, possibly as a result of DNA damage, may be a useful biomarker for atherosclerosis.
Assuntos
Aterosclerose , Ácidos Nucleicos Livres , Fumar Cigarros , Humanos , Aterosclerose/metabolismo , Ácidos Nucleicos Livres/metabolismo , DNA Mitocondrial/metabolismo , Células Endoteliais/metabolismo , Mitocôndrias/metabolismo , Nucleotidiltransferases/genética , Dano ao DNARESUMO
PURPOSE: To evaluate diffusion-weighted imaging (DWI) using echo planar imaging (EPI) with compressed SENSE (EPICS) of the head and neck magnetic resonance imaging (MRI). METHOD: We retrospectively observed 32 patients who underwent head and neck DWI according to either the conventional method (SENSE, reduction factor = 2), fast scanning method (SENSE, reduction factor = 4), or fast scanning method with EPICS (EPICS, reduction factor = 4). For quantitative analysis, contrast-to-noise-ratio (CNR), apparent diffusion coefficient (ADC) values, geometric distortion, and coefficient of variations (CV) were measured and compared. For qualitative analysis, all images were independently and blindly evaluated by two board-certified radiologists. RESULTS: EPICS revealed the higher CNR between all location compared to those of SENSE with reduction factor = 4. Distortion in the anterior-posterior direction was significantly lower on EPICS than on the conventional scan (p = 0.02). A comparison between the ADC values of the EPICS and conventional scan revealed no significant differences. The CV was significantly lower for EPICS than the conventional scan [DWI: 0.22 (IQR: 0.15-0.30) vs 0.32 (IQR: 0.24-0.40), p = 0.02]. CONCLUSIONS: Compressed SENSE combined with the high acceleration factor can improve image quality, homogeneity, and distortion in the head and neck DWI maintaining ADC values and the scan time duration.
Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Cabeça/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Estudos RetrospectivosRESUMO
OBJECTIVE: To assess the image quality of diffusion-weighted imaging (DWI) using multiband (MB) imaging with variable-rate selective excitation (VERSE) and compare it to conventional DWI. METHODS: We retrospectively evaluated hepatic DWI images of patients (n = 76) according to either the conventional method (SENSE, acceleration factor = 2) (n = 38) or fast scanning method (MB imaging with VERSE, acceleration factor = 2 × 2) (n = 38). We also conducted a volunteer study (n = 15) for those scanning methods. During quantitative analysis, the signal-to-noise ratio (SNR), apparent diffusion coefficient values, and contrast in the liver, spleen, and spinal cord were compared between the 2 groups. During qualitative analysis, all images were independently and blindly evaluated by 2 board-certified radiologists. The image contrast, noise, artifacts, and sharpness were assessed, and the performance of classification was measured using receiver operating characteristic curve analysis. RESULTS: In the retrospective study, the SNRs of the hepatic parenchyma and spinal cord between the 2 protocols were significantly different (liver, 8.9 [interquartile range {IQR}, 7.6-12.2] vs 13.0 [IQR, 10.0-16.7]; P < 0.001 and spinal cord, 6.0 [IQR, 4.7-9.4] vs 4.3 [IQR, 3.8-6.8]; P < 0.02). No significant differences between the 2 protocols in the other retrospective analyses were noted. In the receiver operating characteristic curve analysis, area under the curve was 0.49 (95% confidence intervals, 0.40-0.58). CONCLUSION: Multiband VERSE reduced scan time and SNR of hepatic DWI; however, subjective image quality parameters were not significantly impacted.
Assuntos
Imagem de Difusão por Ressonância Magnética , Fígado , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Humanos , Fígado/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-RuídoRESUMO
OBJECTIVES: This study aimed to evaluate the efficacy of a combined wavelet and deep-learning reconstruction (DLR) method for under-sampled pituitary MRI. METHODS: This retrospective study included 28 consecutive patients who underwent under-sampled pituitary T2-weighted images (T2WI). Images were reconstructed using either the conventional wavelet denoising method (wavelet method) or the wavelet and DLR methods combined (hybrid DLR method) at five denoising levels. The signal-to-noise ratio (SNR) of the CSF, hypothalamic, and pituitary images and the contrast between structures were compared between the two image types. Noise quality, contrast, sharpness, artifacts, and overall image quality were evaluated by two board-certified radiologists. The quantitative and the qualitative analyses were performed with robust two-way repeated analyses of variance. RESULTS: Using the hybrid DLR method, the SNR of the CSF progressively increased as denoising levels increased. By contrast, with the wavelet method, the SNR of the CSF, hypothalamus, and pituitary did not increase at higher denoising levels. There was a significant main effect of denoising methods (p < 0.001) and denoising levels (p < 0.001), and an interaction between denoising methods and denoising levels (p < 0.001). For all five qualitative scores, there was a significant main effect of denoising methods (p < 0.001) and an interaction between denoising methods and denoising levels (p < 0.001). CONCLUSIONS: The hybrid DLR method can provide higher image quality for T2WI of the pituitary with compressed sensing (CS) than the wavelet method alone, especially at higher denoising levels. KEY POINTS: ⢠The signal-to-noise ratios of cerebrospinal fluid progressively increased with the hybrid DLR method, with an increase in the denoising level for cerebrospinal fluid in pituitary T2WI with CS. ⢠The signal-to-noise ratios of cerebrospinal fluid using the conventional wavelet method did not increase at higher denoising levels. ⢠All qualitative scores of hybrid deep-learning reconstructions at all denoising levels were higher than those for the wavelet denoising method.
Assuntos
Aprendizado Profundo , Algoritmos , Humanos , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Razão Sinal-RuídoRESUMO
PURPOSE: This study aimed to evaluate whether quantification of myocardial susceptibility by cardiac magnetic resonance imaging (CMR) can be an imaging biomarker for cardiac amyloidosis (CA). MATERIALS AND METHODS: Twenty-six patients with CA underwent CMR, including magnetic phase imaging with a 3.0-T magnetic resonance imaging scanner. Myocardial susceptibility was quantified as a phase shift slope value by magnetic phase analysis. Those values from patients with CA were compared with corresponding values from 18 controls and 15 healthy volunteers. A univariate logistic regression analysis was conducted to identify significant parameters related to CA. RESULTS: The phase shift slope, a quantitative parameter of myocardial susceptibility, was significantly lower in the CA group compared with the control group and compared with healthy volunteers (p < 0.01). From a total of 17 tested variables, 6 were considered to be significant predictors of CA (p ≤ 0.05) during the univariate analysis. The phase shift slope yielded the best AUC of 0.89 (95% CI = 0.79-0.98) for the prediction of CA (p < 0.01). The phase shift slope was significantly correlated with the end-diastolic thickness of the interventricular septum (r = - 0.39, p < 0.01) and posterior wall of the left ventricle (r = - 0.35, p = 0.02). CONCLUSION: Myocardial susceptibility analysis by CMR helps in the diagnosis of patients with CA and can be a new quantitative imaging biomarker for CA.