Resultados 1 - 20 de 125
Filtrar
2.
Arch Dis Child Fetal Neonatal Ed ; 100(2): F121-5, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25389141

RESUMO

BACKGROUND: Delayed umbilical cord clamping (DCC) affects the cardiopulmonary transition and blood volume in neonates immediately after birth. However, little is known of blood flow in the umbilical vessels immediately after birth during DCC. The objective is to describe the duration and patterns of blood flow through the umbilical vessels during DCC. METHODS: Arterial and venous umbilical blood flow was measured during DCC using Doppler ultrasound in uncomplicated term vaginal deliveries. Immediately after birth, the probe was placed in the middle of the umbilical cord, pattern and duration of flow in vein and arteries were evaluated until cord clamping. RESULTS: Thirty infants were studied. Venous flow: In 10% no flow was present, in 57% flow stopped at 4:34 (3:03-7:31) (median (IQR) min:sec) after birth, before the cord was clamped. In 33%, flow continued until cord clamping at 5:13 (2:56-9:15) min:sec. Initially, venous flow was intermittent, increasing markedly during large breaths or stopping and reversing during crying, but then became continuous. Arterial flow: In 17% no flow was present, in 40% flow stopped at 4:22 (2:29-7:17) min:sec, while cord pulsations were still palpable. In 43% flow continued until the cord was clamped at 5:16 (3:32-10:10) min:sec. Arterial flow was pulsatile, unidirectional towards placenta or bidirectional to/from placenta. In 40% flow became continuous towards placenta later on. CONCLUSIONS: During delayed umbilical cord clamping, venous and arterial umbilical flow occurs for longer than previously described. Net placental transfusion is probably the result of several factors of which breathing could play a major role. Umbilical flow is unrelated to cessation of pulsations.


Assuntos
Parto Obstétrico/métodos , Cordão Umbilical/irrigação sanguínea , Índice de Apgar , Peso ao Nascer , Constrição , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Projetos Piloto , Circulação Placentária/fisiologia , Gravidez , Estudos Prospectivos , Fluxo Pulsátil/fisiologia , Ultrassonografia Doppler/métodos , Artérias Umbilicais/diagnóstico por imagem , Artérias Umbilicais/fisiologia , Cordão Umbilical/diagnóstico por imagem , Veias Umbilicais/diagnóstico por imagem , Veias Umbilicais/fisiologia
3.
Arch Dis Child Fetal Neonatal Ed ; 100(1): F24-30, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24942746

RESUMO

OBJECTIVE: The SiPAP flow driver (Care Fusion, Dublin, Ohio, USA) offers synchronised nasal intermittent positive pressure ventilation (sNIPPV) using an abdominal capsule. This study aims to describe the accuracy and effects of synchronised NIPPV using SiPAP in preterm infants. DESIGN: Ten infants, born <28 weeks' gestation, receiving synchronised SiPAP-generated NIPPV, in 'biphasic trigger' mode, were observed. Abdominal capsule signals, delivered pressures, respiratory pattern and oxygen saturations were recorded. Tidal volume (VT), apnoeas, proportion of breaths supported by SiPAP and time between inspiration onset and SiPAP pressure rise were analysed. RESULTS: Infants were of median 26(+0) weeks' gestational age and birth weight 776 g. Mean (SD) respiratory rate (RR) was 53 (14)/min. 82% (17) of spontaneous breaths triggered a SiPAP pressure peak. Mean time between inspiration and SiPAP pressure rise was 28 (20) ms. There was no difference in VT when breaths triggered a SiPAP pressure peak compared with breaths without a pressure peak. No VT was generated by pressure peaks delivered during apnoea. Capsule signals were not recognised following >10% of breaths, resulting in asynchronous NIPPV delivery. Movements resulted in irregular SiPAP pressures and desaturation. When the RR was faster, >55/min, breaths irregularly triggered a SiPAP pressure peak (p=0.003). Compared with times when every breath resulted in a pressure peak, lower mean pressures were achieved, 7.9 vs 8.4 cm H2O (p=0.02). CONCLUSIONS: The SiPAP synchronisation system triggered rapidly with most spontaneous breaths, but did not result in larger tidal volumes. When the RR was >55/min, the SiPAP delivered fewer pressure peaks at lower pressures.


Assuntos
Ventilação com Pressão Positiva Intermitente/métodos , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Ventilação com Pressão Positiva Intermitente/instrumentação , Volume de Ventilação Pulmonar
4.
J Perinatol ; 32(2): 111-6, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21637192

RESUMO

OBJECTIVE: The objective of this study is to compare the effects of back-up ventilation rates (BURs) on triggered inflations and patient cardiorespiratory stability during assist-control/volume guarantee ventilation (AC/VG). STUDY DESIGN: This study is a randomized crossover trial conducted in a neonatal unit in an Australian tertiary NICU. In all, 26 stable preterm infants on AC/VG ventilation were studied at BUR settings of 30, 40 and 50 min(-1). Inflation rate, triggering and cardiorespiratory measures of patient stability were compared during 20 min epochs with 10 min washout periods. RESULT: The 26 infants studied were median (inter-quartile range) gestational age 27 (26, 30) weeks, birth weight 0.84 (0.75, 1.14) kg and FiO(2) 0.24 (0.21, 0.31) and age 6 (4, 19) days. At BURs of 30, 40 and 50, the proportions of inflations, which were triggered, were mean (s.d.) 85% (11), 75% (19) and 61% (25); P<0.01 for all comparisons. Total delivered inflation rates were 56 (8), 58 (9) and 62 (8) min(-1), respectively. Cardiorespiratory parameters did not vary between the settings. CONCLUSION: Using a lower BUR allows greater triggering of ventilator inflations. Cardiorespiratory parameters including CO(2) levels were stable at all rates.


Assuntos
Recém-Nascido Prematuro , Respiração Artificial/instrumentação , Insuficiência Respiratória/terapia , Volume de Ventilação Pulmonar/fisiologia , Austrália , Peso ao Nascer , Estudos Cross-Over , Feminino , Seguimentos , Idade Gestacional , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Masculino , Troca Gasosa Pulmonar , Respiração Artificial/métodos , Insuficiência Respiratória/diagnóstico , Mecânica Respiratória , Medição de Risco , Fatores de Tempo , Resultado do Tratamento , Desmame do Respirador , Ventiladores Mecânicos/estatística & dados numéricos
5.
J Perinatol ; 31(9): 575-85, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21760587

RESUMO

A recent systematic review and meta-analysis shows that volume-targeted ventilation (VTV) compared with pressure-limited ventilation (PLV) reduce death and bronchopulmonary dysplasia, pneumothorax, hypocarbia and severe cranial ultrasound abnormalities. In this paper, we present published research and our experience with volume guarantee (VG) ventilation, a VTV mode available on the Dräger Babylog 8000plus and VN500 ventilators. The VG algorithm measures the expired tidal volume (V(T)) for each inflation and adjusts the peak inflating pressure for the next inflation to deliver a V(T) set by the clinician. The advantage of controlling expired V(T) is that this is less influenced by endotracheal tube leak than inspired V(T). VG ventilation can be used with an endotracheal tube leak up to ∼50%. Initial set V(T) for infants with respiratory distress syndrome should be 4.0 to 5.0 ml kg(-1). The set V(T) should be adjusted to maintain normocapnoea. Setting the peak inflating pressure limit well above the working pressure is important to enable the ventilator to deliver the set V(T), and to avoid frequent alarms. This paper provides a practical guide on how to use VG ventilation.


Assuntos
Respiração Artificial/métodos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Ventiladores Mecânicos , Humanos , Recém-Nascido , Guias de Prática Clínica como Assunto , Respiração Artificial/instrumentação
6.
Arch Dis Child Fetal Neonatal Ed ; 96(6): F422-8, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21335623

RESUMO

BACKGROUND: Nasal intermittent positive pressure ventilation (NIPPV) may be beneficial but the mechanisms of action are undetermined. AIM: To investigate the effects of non-synchronised NIPPV on spontaneous breathing in premature infants. METHODS: 10 infants receiving ventilator generated non-synchronised NIPPV were studied for 30 min. Delivered pressure was measured at the nose; respiration was recorded using respiratory inductance plethysmography. Oxygen saturation, carbon dioxide, heart rate, inspired oxygen and video images were recorded. RESULTS: Median gestational age, birth weight, age and study weight were 25(+3) weeks, 797 g, 24 days and 1076 g. When the NIPPV pressure peak commenced during spontaneous inspiration the inspiratory time increased by 21% (p=0.002), relative tidal volume increased by 15% (p=0.01) and expiratory time was unchanged. When the NIPPV pressure peak commenced during spontaneous expiration the expiratory time increased by 13% (p=0.04). NIPPV pressures delivered during apnoea (range 8-28 cm H(2)O) produced chest inflation 5% of the time, resulting in small tidal volumes (26.7% of spontaneous breath size) but reduced oxygen desaturation. NIPPV pressure peaks occurred throughout spontaneous respiration proportional to the inspiratory: expiratory ratio. CONCLUSION: NIPPV pressure peaks only resulted in a small increase in relative tidal volumes when delivered during spontaneous inspiration. During apnoea pressure peaks occasionally resulted in chest inflation, which ameliorated oxygen desaturations. Infants did not become entrained with the NIPPV pressure changes. Synchronising every rise in applied pressure with spontaneous inspiration may increase the effectiveness of NIPPV and warrants investigation.


Assuntos
Doenças do Prematuro/terapia , Recém-Nascido Prematuro/fisiologia , Ventilação com Pressão Positiva Intermitente/métodos , Respiração , Apneia/fisiopatologia , Apneia/terapia , Peso ao Nascer , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Prematuro/sangue , Doenças do Prematuro/fisiopatologia , Masculino , Oxigênio/sangue , Pletismografia/métodos , Volume de Ventilação Pulmonar/fisiologia
7.
Acta Paediatr ; 100(1): 67-70, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20712839

RESUMO

BACKGROUND: Ventilator frequency is one of the determinants of tidal volume delivery during high-frequency ventilation. Clinicians increasingly use data on ventilator displays to inform their decisions. AIM: To measure the frequencies delivered by the Dräger Babylog 8000plus ventilator when used in high-frequency mode. METHODS: Ventilator waveforms using a test lung were recorded at the full range of settings 5-20 Hz using Spectra software at 1000 Hz. The changes in frequency produced by a 1-Hz change in set frequency were calculated. Actual and displayed frequencies were compared. RESULTS: For settings up to 12 Hz, median (range) difference between set and delivered frequencies was 0 (-0.4 to +0.1) Hz. Above 12 Hz, delivered frequency varied by -0.3 (-1.9 to +0.3) Hz. For 1-Hz changes in frequency settings, in the range 5-12 Hz, 1-Hz changes produced a change in delivered frequency of 1.0 (0.6-1.4) Hz. Above 12 Hz, the corresponding changes were 0.7 (0-2.9) Hz. The ventilator displays the set frequency during operation rather than the delivered frequency. CONCLUSION: At 12 Hz and below, the differences between set and delivered frequencies were relatively small compared with those at 13 Hz and higher. Above 13 Hz, the difference between set and delivered frequencies was up to 2.9 Hz. Some frequency setting changes did not result in a change in delivered frequency.


Assuntos
Equipamentos e Provisões Hospitalares , Ventilação de Alta Frequência/normas , Unidades de Terapia Intensiva Neonatal , Ventiladores Mecânicos/normas , Calibragem/normas , Apresentação de Dados , Desenho de Equipamento , Humanos , Recém-Nascido , Volume de Ventilação Pulmonar
8.
Arch Dis Child Fetal Neonatal Ed ; 96(5): F371-3, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20584798

RESUMO

OBJECTIVE: Early continuous positive airway pressure (CPAP) may reduce lung injury in preterm infants. PATIENTS AND METHODS: Spontaneously breathing preterm infants were randomised immediately after birth to nasal CPAP or intubation, surfactant treatment and mechanical ventilation. Pulmonary function tests approximately 8 weeks post-term determined tidal breathing parameters, respiratory mechanics and functional residual capacity (FRC). RESULTS: Seventeen infants received CPAP and 22 mechanical ventilation. Infants with early CPAP had less mechanical ventilation (4 vs 7.5 days; p=0.004) and less total respiratory support (30 vs 47 days; p=0.017). Post-term the CPAP group had lower respiratory rate (41 vs 48/min; p=0.007), lower minute ventilation (223 vs 265 ml/min/kg; p=0.009), better respiratory compliance (0.99 vs 0.82 ml/cm H(2)O/kg; p=0.008) and improved elastic work of breathing (p=0.004). No differences in FRC were found. CONCLUSIONS: Early CPAP is feasible, shortens the duration of respiratory support and results in improved lung mechanics and decreased work of breathing.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Doenças do Prematuro/prevenção & controle , Lesão Pulmonar/prevenção & controle , Peso ao Nascer , Terapia Combinada , Estudos de Viabilidade , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Doenças do Prematuro/fisiopatologia , Recém-Nascido de muito Baixo Peso , Lesão Pulmonar/fisiopatologia , Masculino , Surfactantes Pulmonares/uso terapêutico , Respiração Artificial/métodos , Mecânica Respiratória , Taxa Respiratória , Volume de Ventilação Pulmonar
10.
Arch Dis Child Fetal Neonatal Ed ; 95(3): F177-81, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20444810

RESUMO

The normal range of heart rate (HR) in the first minutes after birth has not been defined. Objective To describe the HR changes of healthy newborn infants in the delivery room (DR) detected by pulse oximetry. Study Design All inborn infants were eligible and included if a member of the research team attended the birth. Infants were excluded if they received any form of medical intervention in the DR including supplemental oxygen, or respiratory support. HR was measured using a pulse oximeter (PO) with the sensor applied to the right hand or wrist immediately after birth. PO data (oxygen saturation, HR and signal quality) were downloaded every 2 sec and analysed only when the signal had no alarm messages (low IQ signal, low perfusion, sensor off, ambient light). Results Data from 468 infants with 61 650 data points were included. Infants had a mean (range) gestational age of 38 (25-42) weeks and birth weight 2970 (625-5135) g. At 1 min the median (IQR) HR was 96 (65-127) beats per min (bpm) rising at 2 min and 5 min to 139 (110-166) bpm and 163 (146-175) bpm respectively. In preterm infants, the HR rose more slowly than term infants. Conclusions The median HR was <100 bpm at 1 min after birth. After 2 min it was uncommon to have a HR <100 bpm. In preterm infants and those born by caesarean section the HR rose more slowly than term vaginal births.


Assuntos
Frequência Cardíaca/fisiologia , Recém-Nascido/fisiologia , Anestesia Obstétrica/métodos , Peso ao Nascer/fisiologia , Cesárea , Parto Obstétrico/métodos , Feminino , Idade Gestacional , Humanos , Recém-Nascido Prematuro/fisiologia , Oximetria/métodos , Período Pós-Operatório , Gravidez , Valores de Referência
11.
Arch Dis Child Fetal Neonatal Ed ; 95(5): F359-64, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20488862

RESUMO

BACKGROUND: Nasal intermittent positive pressure ventilation (NIPPV) is a mode of non-invasive respiratory support. Its mechanisms of action and optimal delivery techniques are unknown. AIM: This observational study aimed to investigate and quantify delivered peak pressures during non-synchronised ventilator-generated NIPPV. METHODS: Infants born below 30 weeks gestation receiving ventilator-generated NIPPV delivered via Hudson prongs were recruited. Intraprong pressure, change in tidal volume, respiratory rate, oxygen saturations, inspired oxygen and video images were recorded. RESULTS: Eleven infants (four infants were female) of median (interquartile range; IQR) gestational age 25(+/-3) (25(+/-2) 26(+/-0)) weeks and birth weight 732 (699-895) g, were studied at 24 (19-41) days of age. Six infants, with set peak pressure (peak inflation pressure; PIP) of 20 cm H(2)O, received a median pressure of 15.9 (IQR 13.6-17.9) cm H(2)O. 37% of inflations were delivered at least 5 cm H(2)O below set PIP. 12.7% of inflations were delivered above set PIP. Five infants with set PIP of 25 cm H(2)O received a median PIP of 17.2 (IQR 15.0-18.3) cm H(2)O. 83% of inflations were delivered at least 5 cm H(2)O below set PIP, with 6.1% delivered higher than set PIP. The difference in delivered PIP between the groups was 1.3 cm H(2)O. PIP was highest and most variable when the infant was moving. Delivered PIP did not vary whether it coincided with spontaneous inspiration or expiration. CONCLUSION: During ventilator-generated non-synchronised NIPPV delivered PIP was variable and frequently lower than set PIP. Delivered PIP was occasionally greater than set PIP.


Assuntos
Recém-Nascido Prematuro/fisiologia , Ventilação com Pressão Positiva Intermitente/métodos , Pressão do Ar , Peso ao Nascer , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Consumo de Oxigênio/fisiologia , Pletismografia/métodos , Taxa Respiratória/fisiologia , Volume de Ventilação Pulmonar/fisiologia
12.
Semin Fetal Neonatal Med ; 15(4): 203-7, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20435536

RESUMO

Pulse oximetry is commonly used to assist clinicians in assessment and management of newly born infants in the delivery room (DR). In many DRs, pulse oximetry is now the standard of care for managing high risk infants, enabling immediate and dynamic assessment of oxygenation and heart rate. However, there is little evidence that using pulse oximetry in the DR improves short and long term outcomes. We review the current literature on using pulse oximetry to measure oxygen saturation and heart rate and how to apply current evidence to management in the DR.


Assuntos
Frequência Cardíaca/fisiologia , Recém-Nascido/sangue , Oximetria/métodos , Oxigênio/sangue , Salas de Parto , Humanos
13.
Arch Dis Child Fetal Neonatal Ed ; 95(2): F142-3, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20231219

RESUMO

Non-invasive respiratory support is increasingly popular but is associated with complications including nasal trauma. The present report describes a novel method of oral continuous positive airway pressure (CPAP) delivery in an extremely premature infant with severe nasal septum erosion. The distal end of a cut down endotracheal tube was passed through a small hole made in the teat of a dummy (infant pacifier) and sutured in place. The dummy was secured in the infant's mouth and CPAP was delivered to the pharynx. The device was well tolerated and the infant was successfully managed using this technique for 48 days, avoiding endotracheal intubation and ventilation.


Assuntos
Septo Nasal/lesões , Respiração com Pressão Positiva/efeitos adversos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Pressão Positiva Contínua nas Vias Aéreas/métodos , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro
14.
Resuscitation ; 81(6): 737-41, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20334964

RESUMO

AIM: Clinical assessment and end-tidal CO(2) (ETCO(2)) detectors are routinely used to verify correct endotracheal tube (ETT) placement. However, ETCO(2) detectors may mislead clinicians by failing to correctly identify placement of an ETT under a variety of circumstances. A flow sensor measures and displays gas flow in and out of an ETT. We compared endotracheal flow sensor recordings with a colorimetric CO(2)-detector (Pedi-Cap) to detect endotracheal intubation in a preterm sheep model of neonatal resuscitation. METHODS: Six preterm lambs were intubated and ventilated immediately after delivery. At 5 min the oesophagus was also intubated with a similar tube. The endotracheal tube and oesophageal tubes were attached to a Pedi-Cap and flow sensor in random order. Two observers, blinded to the positions of the tubes, used a ETCO(2) detector and the flow sensor recording to determine whether the tube was in the trachea or oesophagus. The experiment was repeated 10 times for each animal. In the last three animals (30 recordings) the number of inflations required to correctly identify the tube placement was noted. RESULTS: The Pedi-Cap and the flow sensor correctly identified tube placement in all studies. Thus, the sensitivity, specificity, and positive and negative predictive values of both devices were 100%. At least three, and up to 10, inflations were required to identify tube location with the Pedi-Cap compared to one or two inflations with the flow sensor. CONCLUSION: A flow sensor correctly identifies tube placement within the first two inflations. The Pedi-Cap required more inflations to correctly identify tube placement.


Assuntos
Animais Recém-Nascidos , Gases , Idade Gestacional , Intubação Intratraqueal , Ventilação Pulmonar , Respiração , Animais , Dióxido de Carbono/análise , Colorimetria/instrumentação , Esôfago , Respiração com Pressão Positiva , Ovinos , Volume de Ventilação Pulmonar , Traqueia
16.
Arch Dis Child Fetal Neonatal Ed ; 94(5): F336-8, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19193666

RESUMO

OBJECTIVE: To measure changes in ventilator parameters in preterm infants receiving surfactant during assist control volume guarantee (AC/VG) ventilation. METHODS: 22 preterm infants (up to 32 weeks' gestation) receiving surfactant for respiratory distress syndrome were enrolled in a prospective study of ventilator parameters during AC/VG ventilation at a tertiary neonatal intensive care unit. Ventilator pressures, flow and tidal volume waveforms were recorded from the Dräger Babylog 8000 plus in real time, and compared to pre-surfactant measurements. RESULTS: Following surfactant administration, 21 of 22 babies experienced completely obstructed endotracheal gas flow. Peak inflation pressure (PIP) increased by a median (IQR) of 8 (4-10) cm H2O, and took 30-60 min to return to baseline. Inspired oxygen concentration was reduced from a median (IQR) of 39% (26%-44%) to 26% (21%-30%) in the first 5 min. The set maximum PIP (Pmax) limited the delivered PIP such that most babies received tidal volumes less than the target value (V(Ttarget)) immediately following surfactant delivery. Four infants, in a subgroup of 11 infants where Pmax was set to less than 10 cm H2O above baseline PIP, were still receiving <90% of V(Ttarget) 20 min post surfactant. CONCLUSIONS: When giving surfactant during AC/VG ventilation, complete obstruction is common. PIPs increased and remain elevated for 30-60 min. The Pmax setting may restrict tidal volume delivery.


Assuntos
Respiração com Pressão Positiva/métodos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Tensoativos/uso terapêutico , Volume de Ventilação Pulmonar/fisiologia , Austrália , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Terapia Intensiva Neonatal , Masculino , Estudos Prospectivos , Síndrome do Desconforto Respiratório do Recém-Nascido/fisiopatologia , Desmame do Respirador/métodos
18.
Arch Dis Child Fetal Neonatal Ed ; 94(2): F84-6, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18701560

RESUMO

BACKGROUND: Two unexpected observations were made during ventilation with the Dräger Babylog 8000+ in volume-guarantee mode: (a) during complete obstruction to gas flow down the endotracheal tube (ETT), positive inspiratory pressure (PIP) was reduced to half way between the maximum inflating pressure and the positive end expiratory pressure (PEEP) even though the set expired tidal volume had not been achieved; (b) an external Dräger waveform monitor may stop displaying real-time waveforms when a tube-obstructed alarm is activated. OBJECTIVE: To investigate these phenomena using a test lung. METHOD: A 50 ml Dräger test lung was attached to the ventilation circuit of a Dräger Babylog 8000+. Partial obstruction to ETT flow was induced by compressing the tubing leading to the test lung, and complete obstruction was achieved by clamping. Recordings were made from the digital output of the ventilator at 125 Hz. RESULTS: When the ETT flow was completely obstructed during VG ventilation, a constant PIP was set midway between the set maximum and PEEP. This did not happen during partial obstruction. The external waveform monitor display froze when ETT flow was completely obstructed. CONCLUSIONS: During complete ETT obstruction, the PIP is set to a pressure midway between maximum PIP and PEEP even if this is less than the PIP used before the obstruction. Further research is needed to evaluate whether this reduction in PIP is associated with prolongation of precipitating events.


Assuntos
Obstrução das Vias Respiratórias/terapia , Resistência das Vias Respiratórias/fisiologia , Ventilação com Pressão Positiva Intermitente/instrumentação , Ventiladores Mecânicos , Obstrução das Vias Respiratórias/fisiopatologia , Desenho de Equipamento , Volume de Ventilação Pulmonar/fisiologia
19.
Arch Dis Child Fetal Neonatal Ed ; 94(2): F87-91, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18703572

RESUMO

BACKGROUND: Because of concerns about harmful effects of 100% oxygen on newborn infants, air has started to be used for resuscitation in the delivery room. OBJECTIVE: To describe changes in preductal oxygen saturation (Spo(2)) and heart rate (HR) in the first 10 min after birth in very preterm infants initially resuscitated with 100% oxygen (OX(100)) or air (OX(21)). PATIENTS AND METHODS: In July 2006, policy changed from using 100% oxygen to air. Observations of Spo(2) and HR before and after the change were recorded whenever a member of the research team was available to attend the birth. RESULTS: There were 20 infants in the OX(100) group and 106 in the OX(21) group. In the OX(100) group, Spo(2) had risen to a median of 84% after 2 min and 94% by 5 min. In the OX(21) group, median Spo(2) was 31% at 2 min and 54% at 5 min. In the OX(21) group, 92% received supplemental oxygen at a median of 5 min; the Spo(2) rose to a median of 81% by 6 min. In the first 10 min after birth, 80% and 55% of infants in the OX(100) and OX(21) groups, respectively, had an Spo(2) > or =95%. Increases in HR over the first 10 min were very similar in the two groups. CONCLUSIONS: Most very preterm infants received supplemental oxygen if air was used for the initial resuscitation. In these infants, the use of backup 100% oxygen and titration against Spo(2) resulted in a similar course to "normal" term and preterm infants. Of the infants resuscitated with 100% oxygen, 80% had Spo(2) > or =95% during the first 10 min. The HR changes in the two groups were very similar.


Assuntos
Ar , Frequência Cardíaca/fisiologia , Doenças do Prematuro/terapia , Oxigênio/administração & dosagem , Insuficiência Respiratória/terapia , Ressuscitação/métodos , Protocolos Clínicos , Salas de Parto , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Doenças do Prematuro/sangue , Doenças do Prematuro/fisiopatologia , Masculino , Oximetria , Oxigênio/sangue , Oxigenoterapia/métodos , Pressão Parcial , Estudos Prospectivos , Fatores de Tempo
20.
Cochrane Database Syst Rev ; (1): CD002977, 2008 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-18254011

RESUMO

BACKGROUND: Nasal continuous positive airway pressure (NCPAP) is used to support preterm infants recently extubated, those experiencing significant apnoea of prematurity and those with respiratory distress soon after birth as an alternative to intubation and ventilation. This review focuses exclusively on identifying the most effective pressure source and interface for NCPAP delivery in preterm infants. OBJECTIVES: To determine which technique of pressure generation and which type of nasal interface for NCPAP delivery most effectively reduces the need for additional respiratory support in preterm infants extubated to NCPAP following intermittent positive pressure ventilation (IPPV) for respiratory distress syndrome (RDS) or in those treated with NCPAP soon after birth. SEARCH STRATEGY: The strategy included searches of MEDLINE (1966 - 2006), the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 4, 2006) CINAHL, abstracts from conference proceedings, cross-referencing of previous reviews and the use of expert informants. SELECTION CRITERIA: Randomised or quasi-randomised trials comparing different techniques of NCPAP pressure generation and/or nasal interfaces in preterm infants extubated to NCPAP following IPPV for RDS or treated with NCPAP soon after birth. DATA COLLECTION AND ANALYSIS: Data was extracted and analysed by the first three authors. Dichotomous results were analysed using the relative risk (RR), risk difference (RD) and number needed to treat (NNT). MAIN RESULTS: 1. Preterm infants being extubated to NCPAP following a period of IPPV for RDS:Meta-analysis of the results from Davis 2001 and Roukema 1999a demonstrated that short binasal prongs are more effective at preventing re-intubation than single nasal or nasopharyngeal prongs [typical RR 0.59 (CI: 0.41, 0.85), typical RD -0.21 (CI: -0.35, -0.07), NNT 5 (CI: 3, 14)]. In one study comparing short binasal prong devices (Sun 1999), the re-intubation rate was significantly lower with the Infant Flow Driver than with the Medicorp prong [RR 0.33 (CI: 0.17, 0.67), RD -0.32 (CI: -0.49, -0.15), NNT 3 (CI: 2, 7)]. The other study comparing short binasal prong devices (Infant Flow Driver versus INCA prongs, Stefanescu 2003) demonstrated no significant difference in the re-intubation rate but did show a significant reduction in the total days in hospital in the Infant Flow Driver group [MD -12.60 (95% CI: -22.81, -2.39) days].2. Preterm infants primarily treated with NCPAP soon after birth:In the one trial identified, Mazzella 2001 found a significantly lower oxygen requirement and respiratory rate in those randomised to short binasal prongs when compared with CPAP delivered via nasopharyngeal prong. The requirement for intubation beyond 48 hours from randomisation was not assessed.3. Studies randomising preterm infants to different NCPAP systems using broad inclusion criteriaThe studies of Rego 2002 and Buettiker 2004 did not examine the primary outcomes of this review. Of the secondary outcomes, Rego 2002 demonstrated a significantly higher incidence of nasal hyperaemia with the use of the Argyle prong compared with Hudson prongs [RR 2.39 (95% CI: 1.27, 4.50), RD 0.28 (95% CI: 0.10, 0.46)]. One study comparing different techniques of pressure generation is awaiting further assessment as it is currently available in abstract form only. AUTHORS' CONCLUSIONS: Short binasal prong devices are more effective than single prongs in reducing the rate of re-intubation. Although the Infant Flow Driver appears more effective than Medicorp prongs the most effective short binasal prong device remains to be determined. The improvement in respiratory parameters with short binasal prongs suggests they are more effective than nasopharyngeal CPAP in the treatment of early RDS. Further studies incorporating longer-term outcomes are required. Studies are also needed to determine the optimal pressure source for the delivery of NCPAP.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Insuficiência Respiratória/terapia , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Ensaios Clínicos Controlados Aleatórios como Assunto , Desmame do Respirador
SELEÇÃO DE REFERÊNCIAS