Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Anal Chem ; 96(28): 11181-11188, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38967089

RESUMO

The COVID-19 pandemic has highlighted the need for rapid and reliable diagnostics that are accessible in resource-limited settings. To address this pressing issue, we have developed a rapid, portable, and electricity-free method for extracting nucleic acids from respiratory swabs (i.e. nasal, nasopharyngeal and buccal swabs), successfully demonstrating its effectiveness for the detection of SARS-CoV-2 in residual clinical specimens. Unlike traditional approaches, our solution eliminates the need for micropipettes or electrical equipment, making it user-friendly and requiring little to no training. Our method builds upon the principles of magnetic bead extraction and revolves around a low-cost plastic magnetic lid, called SmartLid, in combination with a simple disposable kit containing all required reagents conveniently prealiquoted. Here, we clinically validated the SmartLid sample preparation method in comparison to the gold standard QIAamp Viral RNA Mini Kit from QIAGEN, using 406 clinical isolates, including 161 SARS-CoV-2 positives, using the SARS-CoV-2 RT-qPCR assays developed by the US Centers for Disease Control and Prevention (CDC). The SmartLid method showed an overall sensitivity of 95.03% (95% CI: 90.44-97.83%) and a specificity of 99.59% (95% CI: 97.76-99.99%), with a positive agreement of 97.79% (95% CI: 95.84-98.98%) when compared to QIAGEN's column-based extraction method. There are clear benefits to using the SmartLid sample preparation kit: it enables swift extraction of viral nucleic acids, taking less than 5 min, without sacrificing significant accuracy when compared to more expensive and time-consuming alternatives currently available on the market. Moreover, its simplicity makes it particularly well-suited for the point-of-care where rapid results and portability are crucial. By providing an efficient and accessible means of nucleic acid extraction, our approach aims to introduce a step-change in diagnostic capabilities for resource-limited settings.


Assuntos
COVID-19 , RNA Viral , SARS-CoV-2 , Humanos , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/virologia , RNA Viral/isolamento & purificação , RNA Viral/análise , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Manejo de Espécimes/métodos , Teste para COVID-19/métodos , Teste para COVID-19/instrumentação , Técnicas de Diagnóstico Molecular/métodos , Região de Recursos Limitados
2.
Biosens Bioelectron ; 262: 116513, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38941688

RESUMO

Lab-on-Chip electrochemical sensors, such as Ion-Sensitive Field-Effect Transistors (ISFETs), are being developed for use in point-of-care diagnostics, such as pH detection of tumour microenvironments, due to their integration with standard Complementary Metal Oxide Semiconductor (CMOS) technology. With this approach, the passivation of the CMOS process is used as a sensing layer to minimise post-processing, and Silicon Nitride (Si3N4) is the most common material at the microchip surface. ISFETs have the potential to be used for cell-based assays however, there is a poor understanding of the biocompatibility of microchip surfaces. Here, we quantitatively evaluated cell adhesion, morphogenesis, proliferation and mechano-responsiveness of both normal and cancer cells cultured on a Si3N4, sensor surface. We demonstrate that both normal and cancer cell adhesion decreased on Si3N4. Activation of the mechano-responsive transcription regulators, YAP/TAZ, are significantly decreased in cancer cells on Si3N4 in comparison to standard cell culture plastic, whilst proliferation marker, Ki67, expression markedly increased. Non-tumorigenic cells on chip showed less sensitivity to culture on Si3N4 than cancer cells. Treatment with extracellular matrix components increased cell adhesion in normal and cancer cell cultures, surpassing the adhesiveness of plastic alone. Moreover, poly-l-ornithine and laminin treatment restored YAP/TAZ levels in both non-tumorigenic and cancer cells to levels comparable to those observed on plastic. Thus, engineering the electrochemical sensor surface with treatments will provide a more physiologically relevant environment for future cell-based assay development on chip.

3.
IEEE Sens Lett ; 7(8): 1-4, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37529707

RESUMO

Ion-sensitive field-effect transistors (ISFETs) in combination with unmodified complementary metal oxide semiconductors present a point-of-care platform for clinical diagnostics and prognostics. This work illustrates the sensitive and specific detection of two circulating mRNA markers for prostate cancer, the androgen receptor and the TMPRSS2-ERG fusion using a target-specific loop-mediated isothermal amplification method. TMPRSS2-ERG and androgen receptor RNA were detected down to 3x101 and 5x101 copies respectively in under 30 minutes. Administration of these assays onto the ISFET Lab-on-chip device was successful and the specificity of each marker was corroborated with mRNA extracted from prostate cancer cell lines.

4.
IEEE Trans Biomed Circuits Syst ; 17(6): 1293-1304, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37399150

RESUMO

A polymer-assisted graphene transfer method is used to transfer sheets of monolayer and multilayer graphene onto the passivation layer of ion-sensitive field effect transistor arrays. The arrays are fabricated using commercial 0.35 µm complementary metal-oxide-semiconductor (CMOS) technology and contain 3874 pixels sensitive to pH changes on the top silicon nitride surface. By inhibiting dispersive ion transport and hydration of this underlying nitride layer, the transferred graphene sheets help address non-idealities in the sensor response while retaining some pH sensitivity due to the presence of ion adsorption sites. Improvements in hydrophilicity and electrical conductivity of the sensing surface after graphene transfer, as well as in-plane molecular diffusion along the graphene-nitride interface, also greatly improve spatial consistency across an array, allowing for ∼20% more pixels to remain within operating range and enhancing sensor reliability. Multilayer graphene offers a better performance trade-off than monolayer graphene, reducing drift rate by ∼25% and drift amplitude by ∼59% with minimal reduction in pH sensitivity. Monolayer graphene offers slightly better temporal and spatial uniformity in performance of a sensing array, which is associated with the consistency in layer thickness and a lower defect density.


Assuntos
Técnicas Biossensoriais , Grafite , Grafite/química , Reprodutibilidade dos Testes , Técnicas Biossensoriais/métodos , Semicondutores , Óxidos/química , Metais
5.
Comput Biol Med ; 161: 107027, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37211003

RESUMO

The COVID-19 pandemic has highlighted a significant research gap in the field of molecular diagnostics. This has brought forth the need for AI-based edge solutions that can provide quick diagnostic results whilst maintaining data privacy, security and high standards of sensitivity and specificity. This paper presents a novel proof-of-concept method to detect nucleic acid amplification using ISFET sensors and deep learning. This enables the detection of DNA and RNA on a low-cost and portable lab-on-chip platform for identifying infectious diseases and cancer biomarkers. We show that by using spectrograms to transform the signal to the time-frequency domain, image processing techniques can be applied to achieve the reliable classification of the detected chemical signals. Transformation to spectrograms is beneficial as it makes the data compatible with 2D convolutional neural networks and helps gain significant performance improvement over neural networks trained on the time domain data. The trained network achieves an accuracy of 84% with a size of 30kB making it suitable for deployment on edge devices. This facilitates a new wave of intelligent lab-on-chip platforms that combine microfluidics, CMOS-based chemical sensing arrays and AI-based edge solutions for more intelligent and rapid molecular diagnostics.


Assuntos
COVID-19 , Pandemias , Humanos , COVID-19/diagnóstico , Redes Neurais de Computação , DNA , Técnicas de Amplificação de Ácido Nucleico
6.
Microbiol Spectr ; 11(3): e0522222, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37158750

RESUMO

Human malaria is a life-threatening parasitic disease with high impact in the sub-Saharan Africa region, where 95% of global cases occurred in 2021. While most malaria diagnostic tools are focused on Plasmodium falciparum, there is a current lack of testing non-P. falciparum cases, which may be underreported and, if undiagnosed or untreated, may lead to severe consequences. In this work, seven species-specific loop-mediated isothermal amplification (LAMP) assays were designed and evaluated against TaqMan quantitative PCR (qPCR), microscopy, and enzyme-linked immunosorbent assays (ELISAs). Their clinical performance was assessed with a cohort of 164 samples of symptomatic and asymptomatic patients from Ghana. All asymptomatic samples with a parasite load above 80 genomic DNA (gDNA) copies per µL of extracted sample were detected with the Plasmodium falciparum LAMP assay, reporting 95.6% (95% confidence interval [95% CI] of 89.9 to 98.5) sensitivity and 100% (95% CI of 87.2 to 100) specificity. This assay showed higher sensitivity than microscopy and ELISA, which were 52.7% (95% CI of 39.7 to 67%) and 67.3% (95% CI of 53.3 to 79.3%), respectively. Nine samples were positive for P. malariae, indicating coinfections with P. falciparum, which represented 5.5% of the tested population. No samples were detected as positive for P. vivax, P. ovale, P. knowlesi, or P. cynomolgi by any method. Furthermore, translation to the point-of-care was demonstrated with a subcohort of 18 samples tested locally in Ghana using our handheld lab-on-chip platform, Lacewing, showing comparable results to a conventional fluorescence-based instrument. The developed molecular diagnostic test could detect asymptomatic malaria cases, including submicroscopic parasitemia, and it has the potential to be used for point-of-care applications. IMPORTANCE The spread of Plasmodium falciparum parasites with Pfhrp2/3 gene deletions presents a major threat to reliable point-of-care diagnosis with current rapid diagnostic tests (RDTs). Novel molecular diagnostics based on nucleic acid amplification are needed to address this liability. In this work, we overcome this challenge by developing sensitive tools for the detection of Plasmodium falciparum and non-P. falciparum species. Furthermore, we evaluate these tools with a cohort of symptomatic and asymptomatic malaria patients and test a subcohort locally in Ghana. The findings of this work could lead to the implementation of DNA-based diagnostics to fight against the spread of malaria and provide reliable, sensitive, and specific diagnostics at the point of care.


Assuntos
Malária Falciparum , Malária Vivax , Malária , Parasitos , Humanos , Animais , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Malária/diagnóstico , Malária/parasitologia , Malária Vivax/diagnóstico , Malária Vivax/parasitologia , Malária Falciparum/diagnóstico , Malária Falciparum/parasitologia , Plasmodium falciparum/genética
7.
IEEE J Biomed Health Inform ; 27(6): 3093-3103, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37028376

RESUMO

Data-driven approaches for molecular diagnostics are emerging as an alternative to perform an accurate and inexpensive multi-pathogen detection. A novel technique called Amplification Curve Analysis (ACA) has been recently developed by coupling machine learning and real-time Polymerase Chain Reaction (qPCR) to enable the simultaneous detection of multiple targets in a single reaction well. However, target classification purely relying on the amplification curve shapes faces several challenges, such as distribution discrepancies between different data sources (i.e., training vs testing). Optimisation of computational models is required to achieve higher performance of ACA classification in multiplex qPCR through the reduction of those discrepancies. Here, we proposed a novel transformer-based conditional domain adversarial network (T-CDAN) to eliminate data distribution differences between the source domain (synthetic DNA data) and the target domain (clinical isolate data). The labelled training data from the source domain and unlabelled testing data from the target domain are fed into the T-CDAN, which learns both domains' information simultaneously. After mapping the inputs into a domain-irrelevant space, T-CDAN removes the feature distribution differences and provides a clearer decision boundary for the classifier, resulting in a more accurate pathogen identification. Evaluation of 198 clinical isolates containing three types of carbapenem-resistant genes (blaNDM, blaIMP and blaOXA-48) illustrates a curve-level accuracy of 93.1% and a sample-level accuracy of 97.0% using T-CDAN, showing an accuracy improvement of 20.9% and 4.9% respectively. This research emphasises the importance of deep domain adaptation to enable high-level multiplexing in a single qPCR reaction, providing a solid approach to extend qPCR instruments' capabilities in real-world clinical applications.


Assuntos
Reação em Cadeia da Polimerase em Tempo Real , Simulação por Computador , Aprendizado de Máquina , Técnicas de Amplificação de Ácido Nucleico
8.
ACS Sens ; 7(11): 3389-3398, 2022 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-36368032

RESUMO

Prostate cancer (PCa) is the second most common cause of male cancer-related death worldwide. The gold standard of treatment for advanced PCa is androgen deprivation therapy (ADT). However, eventual failure of ADT is common and leads to lethal metastatic castration-resistant PCa. As such, the detection of relevant biomarkers in the blood for drug resistance in metastatic castration-resistant PCa patients could lead to personalized treatment options. mRNA detection is often limited by the low specificity of qPCR assays which are restricted to specialized laboratories. Here, we present a novel reverse-transcription loop-mediated isothermal amplification assay and have demonstrated its capability for sensitive detection of AR-V7 and YAP1 RNA (3 × 101 RNA copies per reaction). This work presents a foundation for the detection of circulating mRNA in PCa on a non-invasive lab-on-chip device for use at the point-of-care. This technique was implemented onto a lab-on-chip platform integrating an array of chemical sensors (ion-sensitive field-effect transistors) for real-time detection of RNA. Detection of RNA presence was achieved through the translation of chemical signals into electrical readouts. Validation of this technique was conducted with rapid detection (<15 min) of extracted RNA from prostate cancer cell lines 22Rv1s and DU145s.


Assuntos
Neoplasias de Próstata Resistentes à Castração , Humanos , Masculino , Neoplasias de Próstata Resistentes à Castração/diagnóstico , Neoplasias de Próstata Resistentes à Castração/genética , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Receptores Androgênicos/genética , Receptores Androgênicos/metabolismo , RNA Mensageiro/genética , Antagonistas de Androgênios/uso terapêutico , Laboratórios , Prognóstico , RNA
9.
Front Bioeng Biotechnol ; 10: 892853, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36185458

RESUMO

Dengue is one of the most prevalent infectious diseases in the world. Rapid, accurate and scalable diagnostics are key to patient management and epidemiological surveillance of the dengue virus (DENV), however current technologies do not match required clinical sensitivity and specificity or rely on large laboratory equipment. In this work, we report the translation of our smartphone-connected handheld Lab-on-Chip (LoC) platform for the quantitative detection of two dengue serotypes. At its core, the approach relies on the combination of Complementary Metal-Oxide-Semiconductor (CMOS) microchip technology to integrate an array of 78 × 56 potentiometric sensors, and a label-free reverse-transcriptase loop mediated isothermal amplification (RT-LAMP) assay. The platform communicates to a smartphone app which synchronises results in real time with a secure cloud server hosted by Amazon Web Services (AWS) for epidemiological surveillance. The assay on our LoC platform (RT-eLAMP) was shown to match performance on a gold-standard fluorescence-based real-time instrument (RT-qLAMP) with synthetic DENV-1 and DENV-2 RNA and extracted RNA from 9 DENV-2 clinical isolates, achieving quantitative detection in under 15 min. To validate the portability of the platform and the geo-tagging capabilities, we led our study in the laboratories at Imperial College London, UK, and Kaohsiung Medical Hospital, Taiwan. This approach carries high potential for application in low resource settings at the point of care (PoC).

10.
Biosens Bioelectron ; 216: 114633, 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36081245

RESUMO

The unmet clinical need for accurate point-of-care (POC) diagnostic tests able to discriminate bacterial from viral infection demands a solution that can be used both within healthcare settings and in the field, and that can also stem the tide of antimicrobial resistance. Our approach to solve this problem combine the use of host gene signatures with our Lab-on-a-Chip (LoC) technology enabling low-cost POC expression analysis to detect Infectious Disease. Transcriptomics have been extensively investigated as a potential tool to be implemented in the diagnosis of infectious disease. On the other hand, LoC technologies using ion-sensitive field-effect transistor (ISFET), in conjunction with isothermal chemistries, are offering a promising alternative to conventional amplification instruments, owing to their portable and affordable nature. Currently, the data analysis of ISFET arrays are restricted to established methods by averaging the output of every sensor to give a single time-series. This simple approach makes unrealistic assumptions, leading to insufficient performance for applications that require accurate quantification such as Host-Transcriptomics. In order to reliably quantify transcripts on our LoC platform enabling the classification of infectious disease on-chip, we propose a novel data-driven algorithm for extracting time-to-positive values from ISFET arrays. The algorithm proposed correctly outputs a time-to-positive for all the reactions, with a high correlation to RT-qLAMP (0.85, R2 = 0.98, p < 0.01), resulting in a classification accuracy of 100% (CI, 95-100%). This work aims to bridge the gap between translating assays from microarray analysis to ISFET arrays providing benefits on tackling infectious disease and diagnostic testing in hard-to-reach areas of the world.


Assuntos
Anti-Infecciosos , Técnicas Biossensoriais , Doenças Transmissíveis , Viroses , Bactérias/genética , Humanos , Dispositivos Lab-On-A-Chip , Técnicas de Amplificação de Ácido Nucleico/métodos , Sistemas Automatizados de Assistência Junto ao Leito , RNA
11.
Sci Data ; 9(1): 395, 2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35817775

RESUMO

When used in combination with hormone treatment, Palbociclib prolongs progression-free survival of patients with hormone receptor positive breast cancer. Mechanistically, Palbociclib inhibits CDK4/6 activity but the basis for differing sensitivity of cancer to Palbociclib is poorly understood. A common observation in a subset of Triple Negative Breast Cancers (TNBCs) is that prolonged CDK4/6 inhibition can engage a senescence-like state where cells exit the cell cycle, whilst, remaining metabolically active. To better understand the senescence-like cell state which arises after Palbociclib treatment we used mass spectrometry to quantify the proteome, phosphoproteome, and secretome of Palbociclib-treated MDA-MB-231 TNBC cells. We observed altered levels of cell cycle regulators, immune response, and key senescence markers upon Palbociclib treatment. These datasets provide a starting point for the derivation of biomarkers which could inform the future use CDK4/6 inhibitors in TNBC subtypes and guide the development of potential combination therapies.


Assuntos
Neoplasias de Mama Triplo Negativas , Quinase 4 Dependente de Ciclina/antagonistas & inibidores , Quinase 6 Dependente de Ciclina/antagonistas & inibidores , Feminino , Humanos , Proteoma , Proteômica , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Neoplasias de Mama Triplo Negativas/metabolismo
12.
IEEE Trans Biomed Circuits Syst ; 16(4): 545-556, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35763475

RESUMO

In this paper, a complete Lab-on-Chip (LoC) ion imaging platform for analysing Ion-Selective Membranes (ISM) using CMOS ISFET arrays is presented. An array of 128 × 128 ISFET pixels is employed with each pixel featuring 4 transistors to bias the ISFET to a common drain amplifier. Column-level 2-step readout circuits are designed to compensate for array offset variations in a range of up to ±1 V. The chemical signal associated with a change in ionic concentration is stored and fed back to a programmable gain instrumentation amplifier for compensation and signal amplification through a global system feedback loop. This column-parallel signal pipeline also integrates an 8-bit single slope ADC and an 8-bit R-2R DAC to quantise the processed pixel output. Designed and fabricated in the TSMC 180 nm BCD process, the System-on-Chip (SoC) operates in real time with a maximum frame rate of 1000 fps, whilst occupying a silicon area of 2.3 mm × 4.5 mm. The readout platform features a high-speed digital system to perform system-level feedback compensation with a USB 3.0 interface for data streaming. With this platform we show the first reported analysis and characterisation of ISMs using an ISFETs array through capturing real-time high-speed spatio-temporal information at a resolution of 16 µm in 1000 fps, extracting time-response and sensitivity. This work paves the way of understanding the electrochemical response of ISMs, which are widely used in various biomedical applications.


Assuntos
Silício , Desenho de Equipamento , Concentração de Íons de Hidrogênio , Íons , Análise de Sequência com Séries de Oligonucleotídeos
13.
Sci Rep ; 12(1): 8750, 2022 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-35610285

RESUMO

Cervical cancer affects over half a million people worldwide each year, the majority of whom are in resource-limited settings where cytology screening is not available. As persistent human papilloma virus (HPV) infections are a key causative factor, detection of HPV strains now complements cytology where screening services exist. This work demonstrates the efficacy of a handheld Lab-on-Chip (LoC) device, with an external sample extraction process, in detecting cervical cancer from biopsy samples. The device is based on Ion-Sensitive Field-Effect Transistor (ISFET) sensors used in combination with loop-mediated isothermal amplification (LAMP) assays, to amplify HPV DNA and human telomerase reverse transcriptase (hTERT) mRNA. These markers were selected because of their high levels of expression in cervical cancer cells, but low to nil expression in normal cervical tissue. The achieved analytical sensitivity for the molecular targets resolved down to a single copy per reaction for the mRNA markers, achieving a limit of detection of 102 for hTERT. In the tissue samples, HPV-16 DNA was present in 4/5 malignant and 2/5 benign tissues, with HPV-18 DNA being present in 1/5 malignant and 1/5 benign tissues. hTERT mRNA was detected in all malignant and no benign tissues, with the demonstrated pilot data to indicate the potential for using the LoC in cervical cancer screening in resource-limited settings on a large scale.


Assuntos
Alphapapillomavirus , Infecções por Papillomavirus , Telomerase , Neoplasias do Colo do Útero , Alphapapillomavirus/genética , Biomarcadores Tumorais/genética , Detecção Precoce de Câncer , Feminino , Humanos , Papillomaviridae/genética , Papillomaviridae/metabolismo , Sistemas Automatizados de Assistência Junto ao Leito , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Telomerase/genética , Telomerase/metabolismo , Neoplasias do Colo do Útero/patologia
14.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 7385-7389, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34892804

RESUMO

The growing cancer burden necessitates the development of cost-effective solutions that provide rapid, precise and personalised information to improve patient outcome. The aim of this study was to develop a novel, Lab-on-Chip compatible method for the detection and quantification of DNA methylation for MGMT, a well-established molecular biomarker for glioblastoma, with direct clinical translation as a predictive target. A Lab-on-Chip compatible isothermal amplification method (LAMP) was used to test its efficacy for detection of sequence-specific methylated regions of MGMT, with the method's specificity and sensitivity to have been compared against gold-standards (MethyLight, JumpStart). Our LAMP primer combinations were shown to be specific to the MGMT methylated region, while sensitivity assays determined that the amplification methods were capable of running at clinically relevant DNA concentrations of 0.2 - 20 ng/µL. For the first time, the ability to detect the presence of DNA methylation on bisulfite converted DNA was demonstrated on a Lab-on-Chip setup, laying the foundation for future applications of this platform to other epigenetic biomarkers in a point-of-care setting.


Assuntos
Glioblastoma , Metilação de DNA , Metilases de Modificação do DNA/genética , Metilases de Modificação do DNA/metabolismo , Enzimas Reparadoras do DNA/genética , Enzimas Reparadoras do DNA/metabolismo , Epigenômica , Humanos , Análise de Sequência com Séries de Oligonucleotídeos , Regiões Promotoras Genéticas , Proteínas Supressoras de Tumor/genética , Proteínas Supressoras de Tumor/metabolismo
15.
Front Oncol ; 11: 747614, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34790573

RESUMO

OBJECTIVE: To establish the sensitivity and specificity of a human papillomavirus (HPV) and tumor marker DNA/mRNA assay for detecting cervical cancer that is transferrable to a Lab-on-a-chip platform and determine its diagnostic benefit in early stage disease when used in conjunction with high-resolution endovaginal magnetic resonance imaging (MRI). METHODS: Forty-one patients (27 with Stage1 cervical cancer [Group1] and 14 non-cancer HPV negative controls [Group2]) had DNA and RNA extracted from cervical cytology swab samples. HPV16, HPV18, hTERT, TERC/GAPDH and MYC/GAPDH concentration was established using a loop mediated isothermal amplification (LAMP) assay. Thresholds for tumor marker detection for Group1 were set from Group2 analysis (any hTERT, TERC/GAPDH 3.12, MYC/GAPDH 0.155). Group 1 participants underwent endovaginal MRI. Sensitivity and specificity for cancer detection by LAMP and MRI individually and combined was documented by comparison to pathology. RESULTS: Sensitivity and specificity for cancer detection was 68.8% and 77.8% if any tumor marker was positive regardless of HPV status (scenario1), and 93.8% and 55.8% if tumor marker or HPV were positive (scenario 2). Adding endovaginal MRI improved specificity to 88.9% in scenario 1 (sensitivity 68.8%) and to 77.8%% in scenario2 (sensitivity 93.8%). CONCLUSION: Specificity for cervical cancer detection using a LAMP assay is superior with tumor markers; low sensitivity is improved by HPV detection. Accuracy for early stage cervical cancer detection is optimal using a spatially multiplexed tumor marker/HPV LAMP assay together with endovaginal MRI.

16.
IEEE Trans Biomed Circuits Syst ; 15(3): 380-389, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34214044

RESUMO

ESR1 mutations are important biomarkers in metastatic breast cancer. Specifically, p.E380Q and p.Y537S mutations arise in response to hormonal therapies given to patients with hormone receptor positive (HR+) breast cancer (BC). This paper demonstrates the efficacy of an ISFET based CMOS integrated Lab-on-Chip (LoC) system, coupled with variant-specific isothermal amplification chemistries, for detection and discrimination of wild type (WT) from mutant (MT) copies of the ESR1 gene. Hormonal resistant cancers often lead to increased chances of metastatic disease which leads to high mortality rates, especially in low-income regions and areas with low healthcare coverage. Design and optimization of bespoke primers was carried out and tested on a qPCR instrument and then benchmarked versus the LoC platform. Assays for detection of p.Y537S and p.E380Q were developed and tested on the LoC platform, achieving amplification in under 25 minutes and sensitivity of down to 1000 copies of DNA per reaction for both target assays. The LoC system hereby presented, is cheaper and smaller than other standard industry equivalent technologies such as qPCR and sequencing. The LoC platform proposed, has the potential to be used at a breast cancer point-of-care testing setting, offering mutational tracking of circulating tumour DNA in liquid biopsies to assist patient stratification and metastatic monitoring.


Assuntos
Neoplasias da Mama , Neoplasias da Mama/genética , Receptor alfa de Estrogênio/genética , Feminino , Humanos , Mutação
17.
ACS Cent Sci ; 7(2): 307-317, 2021 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-33649735

RESUMO

The COVID-19 pandemic is a global health emergency characterized by the high rate of transmission and ongoing increase of cases globally. Rapid point-of-care (PoC) diagnostics to detect the causative virus, SARS-CoV-2, are urgently needed to identify and isolate patients, contain its spread and guide clinical management. In this work, we report the development of a rapid PoC diagnostic test (<20 min) based on reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) and semiconductor technology for the detection of SARS-CoV-2 from extracted RNA samples. The developed LAMP assay was tested on a real-time benchtop instrument (RT-qLAMP) showing a lower limit of detection of 10 RNA copies per reaction. It was validated against extracted RNA from 183 clinical samples including 127 positive samples (screened by the CDC RT-qPCR assay). Results showed 91% sensitivity and 100% specificity when compared to RT-qPCR and average positive detection times of 15.45 ± 4.43 min. For validating the incorporation of the RT-LAMP assay onto our PoC platform (RT-eLAMP), a subset of samples was tested (n = 52), showing average detection times of 12.68 ± 2.56 min for positive samples (n = 34), demonstrating a comparable performance to a benchtop commercial instrument. Paired with a smartphone for results visualization and geolocalization, this portable diagnostic platform with secure cloud connectivity will enable real-time case identification and epidemiological surveillance.

18.
J Clin Microbiol ; 58(11)2020 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-32907990

RESUMO

Aspergillus fumigatus has widely evolved resistance to the most commonly used class of antifungal chemicals, the azoles. Current methods for identifying azole resistance are time-consuming and depend on specialized laboratories. There is an urgent need for rapid detection of these emerging pathogens at point-of-care to provide the appropriate treatment in the clinic and to improve management of environmental reservoirs to mitigate the spread of antifungal resistance. Our study demonstrates the rapid and portable detection of the two most relevant genetic markers linked to azole resistance, the mutations TR34 and TR46, found in the promoter region of the gene encoding the azole target cyp51A. We developed a lab-on-a-chip platform consisting of: (i) tandem-repeat loop-mediated isothermal amplification; (ii) state-of-the-art complementary metal-oxide-semiconductor microchip technology for nucleic acid amplification detection; and (iii) a smartphone application for data acquisition, visualization, and cloud connectivity. Specific and sensitive detection was validated with isolates from clinical and environmental samples from 6 countries across 5 continents, showing a lower limit of detection of 10 genomic copies per reaction in less than 30 min. When fully integrated with a sample preparation module, this diagnostic system will enable the detection of this ubiquitous fungus at the point-of-care, and could help to improve clinical decision making, infection control, and epidemiological surveillance.


Assuntos
Aspergilose , Aspergillus fumigatus , Antifúngicos/farmacologia , Aspergillus fumigatus/genética , Azóis/farmacologia , Farmacorresistência Fúngica , Proteínas Fúngicas/genética , Humanos , Dispositivos Lab-On-A-Chip , Testes de Sensibilidade Microbiana , Técnicas de Diagnóstico Molecular , Mutação , Técnicas de Amplificação de Ácido Nucleico
19.
Anal Chem ; 92(19): 13134-13143, 2020 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-32946688

RESUMO

Information about the kinetics of PCR reactions is encoded in the amplification curve. However, in digital PCR (dPCR), this information is typically neglected by collapsing each amplification curve into a binary output (positive/negative). Here, we demonstrate that the large volume of raw data obtained from real-time dPCR instruments can be exploited to perform data-driven multiplexing in a single fluorescent channel using machine learning methods, by virtue of the information in the amplification curve. This new approach, referred to as amplification curve analysis (ACA), was shown using an intercalating dye (EvaGreen), reducing the cost and complexity of the assay and enabling the use of melting curve analysis for validation. As a case study, we multiplexed 3 carbapenem-resistant genes to show the impact of this approach on global challenges such as antimicrobial resistance. In the presence of single targets, we report a classification accuracy of 99.1% (N = 16188), which represents a 19.7% increase compared to multiplexing based on the final fluorescent intensity. Considering all combinations of amplification events (including coamplifications), the accuracy was shown to be 92.9% (N = 10383). To support the analysis, we derived a formula to estimate the occurrence of coamplification in dPCR based on multivariate Poisson statistics and suggest reducing the digital occupancy in the case of multiple targets in the same digital panel. The ACA approach takes a step toward maximizing the capabilities of existing real-time dPCR instruments and chemistries, by extracting more information from data to enable data-driven multiplexing with high accuracy. Furthermore, we expect that combining this method with existing probe-based assays will increase multiplexing capabilities significantly. We envision that once emerging point-of-care technologies can reliably capture real-time data from isothermal chemistries, the ACA method will facilitate the implementation of dPCR outside of the lab.


Assuntos
Aprendizado de Máquina , Reação em Cadeia da Polimerase em Tempo Real , beta-Lactamases/genética , Carbapenêmicos/química , Carbapenêmicos/metabolismo , beta-Lactamases/metabolismo
20.
Sci Rep ; 10(1): 8448, 2020 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-32439986

RESUMO

The increasing prevalence of antimicrobial resistance is a serious threat to global public health. One of the most concerning trends is the rapid spread of Carbapenemase-Producing Organisms (CPO), where colistin has become the last-resort antibiotic treatment. The emergence of colistin resistance, including the spread of mobilized colistin resistance (mcr) genes, raises the possibility of untreatable bacterial infections and motivates the development of improved diagnostics for the detection of colistin-resistant organisms. This work demonstrates a rapid response for detecting the most recently reported mcr gene, mcr-9, using a portable and affordable lab-on-a-chip (LoC) platform, offering a promising alternative to conventional laboratory-based instruments such as real-time PCR (qPCR). The platform combines semiconductor technology, for non-optical real-time DNA sensing, with a smartphone application for data acquisition, visualization and cloud connectivity. This technology is enabled by using loop-mediated isothermal amplification (LAMP) as the chemistry for targeted DNA detection, by virtue of its high sensitivity, specificity, yield, and manageable temperature requirements. Here, we have developed the first LAMP assay for mcr-9 - showing high sensitivity (down to 100 genomic copies/reaction) and high specificity (no cross-reactivity with other mcr variants). This assay is demonstrated through supporting a hospital investigation where we analyzed nucleic acids extracted from 128 carbapenemase-producing bacteria isolated from clinical and screening samples and found that 41 carried mcr-9 (validated using whole genome sequencing). Average positive detection times were 6.58 ± 0.42 min when performing the experiments on a conventional qPCR instrument (n = 41). For validating the translation of the LAMP assay onto a LoC platform, a subset of the samples were tested (n = 20), showing average detection times of 6.83 ± 0.92 min for positive isolates (n = 14). All experiments detected mcr-9 in under 10 min, and both platforms showed no statistically significant difference (p-value > 0.05). When sample preparation and throughput capabilities are integrated within this LoC platform, the adoption of this technology for the rapid detection and surveillance of antimicrobial resistance genes will decrease the turnaround time for DNA detection and resistotyping, improving diagnostic capabilities, patient outcomes, and the management of infectious diseases.


Assuntos
Bactérias/genética , Infecções Bacterianas/diagnóstico , Proteínas de Bactérias/genética , Colistina/farmacologia , Farmacorresistência Bacteriana , Dispositivos Lab-On-A-Chip , Ácidos Nucleicos/análise , Antibacterianos/farmacologia , Bactérias/efeitos dos fármacos , Bactérias/isolamento & purificação , Infecções Bacterianas/tratamento farmacológico , Infecções Bacterianas/genética , Infecções Bacterianas/microbiologia , Proteínas de Bactérias/metabolismo , Humanos , Ácidos Nucleicos/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA