Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Public Health Res Pract ; 31(5)2021 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-34873611

RESUMO

OBJECTIVE: A high prevalence of hearing loss in older adults contrasts with a small proportion of people who seek help. Emerging developments in hearing healthcare (HHC) could reduce costs but may not increase access. This study evaluated older adults' perceptions of current and future HHC services in Australia, England, US and Canada to explore potential levers and system improvements. METHODS: Semi-structured focus groups (n = 47) were conducted, and data were analysed using a directed content analysis. Participants were adults 60 years and older with a) no hearing problems; b) hearing problems and hearing aid use; and c) hearing problems and no hearing aid use. RESULTS: Perceived barriers, facilitators and preferences were largely consistent across countries, with stigma and trust in HHC being the barriers most often discussed. CONCLUSION: Although cost and access were consistently deemed important, there may be limited change in help-seeking and HHC uptake unless the key barriers of trust and stigma are addressed. When seeking to undertake transformative change to healthcare it is important to engage recipients of care to understand existing barriers and coproduce a user-centered solution.


Assuntos
Auxiliares de Audição , Audição , Idoso , Austrália , Inglaterra , Acessibilidade aos Serviços de Saúde , Humanos
2.
J Am Acad Audiol ; 30(3): 208-216, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30461396

RESUMO

BACKGROUND: The projected increase in the aging population raises concerns about how to manage the health-care needs in a cost-effective way. Within hearing health care, there are presently too few audiologists to meet the expected demand, and training more professionals may not be a feasible way of addressing this problem. For this reason, there is a need to develop different ways of assessing hearing sensitivity that can be conducted accurately and inexpensively when a certified audiologist and/or sound-attenuated booth is unavailable. More specifically, there is a need to determine if the Etymotic Home Hearing Test (HHT) can yield accurate and reliable data from older adults with varying degrees of hearing loss. PURPOSE: To compare audiometric thresholds obtained using the HHT, an automated pure-tone air-conduction test, to those obtained using manual audiometry (MA), among older adults with varying degrees of hearing loss. STUDY SAMPLE: Participants were 112 English-speaking adults (58% Female), aged 60 yr and older. Participants were excluded from this study if otoscopy revealed cerumen impaction and/or suspected ear pathology. INTERVENTION: All participants completed the HHT on tablet computers in a carpeted classroom and MA in a double-walled sound-attenuated booth using insert earphones for both measures. Both measures were completed in the same test session, and the order of testing (MA versus HHT) was counterbalanced. DATA COLLECTION AND ANALYSIS: Absolute differences in threshold measurements (in dB HL) were calculated across all ears (n = 224 ears) and for all frequencies (octave frequencies from 0.5 to 8 kHz). Correlation and multiple linear regression analyses were conducted to determine if thresholds obtained using the HHT significantly correlated with thresholds using MA. Mean thresholds for each method (HHT and MA) were compared using correlation analyses for each test frequency. Multiple linear regression analysis was used to examine the relationship between the four-frequency pure-tone average (PTA) (average threshold at 0.5, 1, 2, and 4 kHz) in the better-hearing ear measured using the HHT and a set of seven independent factors: four-frequency PTA in the better-hearing ear measured via MA, treatment group (HHT versus MA), age, gender, and degree of hearing loss (mild, moderate, and >moderate). RESULTS: Correlation analyses revealed significant frequency-specific correlations, ranging from 0.91 to 0.97 (p < 0.001), for air-conduction thresholds obtained using the HHT and MA. Mean HHT thresholds were significantly correlated with mean MA thresholds in both ears across the frequency range. This relationship held true across different degrees of hearing loss. The regression model accounted for a significant amount of variance in the HHT better-ear PTA, with MA better-ear PTA being the only significant predictor in our final model, with no effect of degree of loss, age, or gender. CONCLUSIONS: The HHT is an accurate and cost-effective method of establishing pure-tone air-conduction thresholds, when compared with MA. Therefore, the HHT can be used as a tool to acquire accurate air-conduction hearing thresholds from older adults, in-group settings, without the use of a sound-attenuated booth or a certified audiologist.


Assuntos
Audiometria de Tons Puros/métodos , Limiar Auditivo/fisiologia , Perda Auditiva/diagnóstico , Saúde Pública , Feminino , Perda Auditiva/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA